If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Oct 2024
Closing Date31 Oct 2024
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per srl item No. 2 here-in-before but One 3 Pin socket outlet 5 Amps on same board.

10

-

-

... More
All as per srl item No. 2 here-in-before but One light point controlled by two, two way switch

2

-

-

... More
All as per srl item No. 2 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.

60

-

-

... More
M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in existing conduit, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light/fan/bell/exhaust fan point controlled by one switch. :- Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.

50

-

-

... More
All as per srl item No. 7 here-in-before but One 3 Pin socket outlet 5 Amps on Independent board.

50

-

-

... More
All as per srl item No. 7 here-in-before but One 3 Pin socket outlet 5 Amps on same board.

10

-

-

... More
All as per srl item No. 7 here-in-before but One light point controlled by two, two way switch

2

-

-

... More
All as per srl item No. 7 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.

50

-

-

... More
S & F Modular Switch 16 Amp, 1 Module with red indication, single pole one way, ISI marked complete all as specified

110

-

-

... More
S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module complete all as specified and directed

110

-

-

... More
S & F Modular Switch 1 way 6 /10 A, 1 Module complete all as specified and directed.

210

-

-

... More
S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module complete all as specified and directed.

100

-

-

... More
S & F Modular Switch 2 way 6 / 10 A, 1 Module complete all as specified and directed.

8

-

-

... More
S & F Modular fan regulator step type, 120W 2 Module complete all as specified and directed.

20

-

-

... More
S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed.

110

-

-

... More
S & F of Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, 240 Volts, complete all as specified and directed.

4

-

-

... More
Supply and modular AC box with top pin and earth plug and socket complete with one Single pole MCB 25 Amp, 240 Volts, complete all as specified and directed.

45

-

-

... More
S & F in repair LED light fitting wall / roof mounted, 20 watt, able to change colour from warm white to natural white to cool white with a toggle switch, with driver complete suitable body robust, corrosion resistant, superior finish and the system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.

300

-

-

... More
S & F in repair LED light fitting wall / roof mounted, 20 watt, Inverter LED batten with square profile, Lithium Ion battery with charging time 8 hrs-10 hrs and back up time upto 4 hrs, with driver complete suitable body robust, corrosion resistant, superior finish and the system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.

270

-

-

... More
S & F in repair LED light fitting wall / roof mounted, 25 watt, with driver complete suitable body robust, corrosion resistant, superior finish and the system wattage of fitting should not be more than 25 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed

360

-

-

... More
S & F in repair LED light fitting wall / roof mounted, 36 watt, with driver complete suitable body robust, corrosion resistant, superior finish and the system wattage of fitting should not be more than 36 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.

150

-

-

... More
S & F in replacement ceiling recessed mounting LED luminaire 600 mm x 600 mm, (2' x2') 35/36 watt, 220 VAC with high efficiency PMMA diffuser soft glare free light complete with driver, surge protection & LED lamp, including connecting up with driver three core flexible copper conductor wire of 0.5sqmm size. The system wattage of fitting should not be more than 10 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90 cool white colour, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.

247

-

-

... More
S & F in replacement Surface mounted LED Round light fitting 18 watt, round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips (CCT- 6500K), PF0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.

45

-

-

... More
S & F in replacement Surface Spotlight with aluminium structure, with adjustable light engine to achieve the desired illumination angle of 7 watt, with high efficient LEDs and glare free including fixing accessories (CCT- 3000K), PF0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.

30

-

-

... More
S & F in replacement Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base including fixing accessories complete all as specified and directed.

15

-

-

... More
Supply and fix in replacement of energy efficient wall mounted LED bulk head light fitting 10 / 12 watt, Outdoor IP65 Motion Sensor LED Bulkhead Light, CW 6500K , PF0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.

27

-

-

... More
Supply and fix in replacement Building security light 18 / 20 W, Motion Sensor Street Light, energy efficient, should stays on as long as motion is detected, then dims to 20% if no movement is detected for 90 seconds, inbuilt Microwave sensor, suitable for indoors / outdoors with high efficient high power LED enclosed with toughened glass and Voltage rated 220V to 240V etc complete all as specified and directed.

45

-

-

... More
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.50 sqmm size complete all as specified and directed

180

-

-

... More
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.75 sqmm size complete all as specified and directed

180

-

-

... More
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 1.00 sqmm size complete all as specified and directed

270

-

-

... More
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 2.50 sqmm size complete all as specified and directed

540

-

-

... More
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, 3 core, 4.00 sqmm size complete all as specified and directed

540

-

-

... More
Supply and fix in repair Electric bell, Ding-Dong type, AC 230 Volts, Single Phase.complete all as specified and directed

30

-

-

... More
Supply and fix in repair electronic tamper proof meter of cap 5 to 30 Amp, connection of incoming wire and outgoing connection with wire of proper colour code of 6 sqmm upto DB and sealing the meter with sealing wire & sealing lead and depositing the same into MES Storeyard complete all as specified & directed

15

-

-

... More
Supply & fixing in replacement tamper proof, 3-phase, 4-wire, 230/240 V (L-N), 400/415 V (L-L), 100 A, Accuracy class 1.0, 50 Hz ± 5%, direct-connected energy meter with advanced revenue protection features, interoperable communications protocol, and support for reading in the absence of mains supply, with LCD display and poly carbonate body, extended terminal block made of high grade non hydroscopic fire retardant, low tracking, fire resistance re-inforced poly carbonate or equivalent high grade engineering plastic with brass terminal complete conform to IS 13779, IEC 62052-11, IEC 62053-21 standard and suitable electrical connection with lugs INCLUDING TRANSPARENT METER BOX duly fixed on the walls with locking arrangements and making the existing lines including dismantling of old unserviceable electric meter any type and depositing the same into MES Store yard complete all as specified and directed.

3

-

-

... More
Supply and fix in replacement Plug Top 15 Amps complte all as specified and directed

50

-

-

... More
Supply and fix in replacement Automatic Changeover & Current Limiter (ACCL) 30 A, DIN mounted, Single Phase, 240 V, for EB & UPS complete all as specified and directed.

12

-

-

... More
Supply and fix in replacement Dual Power Automatic Transfer Switch, 4P, 100A, 220V, DIN Rail Mount, Changeover Switch Automatic Transfer Switch, Dual Power Toggle Controller Dual Electronic Power Circuit Breaker of Flylin complete all as specified and directed.

12

-

-

... More
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed.

1100

-

-

... More
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit 20 mm dia or higher, medium grade complete with all PVC accessories and 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as directed. Note : 1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit. 2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.

450

-

-

... More
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit 20 mm dia or higher, medium grade complete with all PVC accessories and 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as directed. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit. 2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.

650

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.