Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Jun 2024
Closing Date8 Jul 2024
Tender Amount₹ 49,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engg- in- Charge. Note : Measurement shall be taken after punning down.

142.84

-

-

... More
Supply and laying of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engg- in- Charge.

4507

-

-

... More
All as per srl item No 05 here-in-before but using old bricks complete all as specified and directed by Engg- in- Charge.

3005

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm as protection for electric cables complete all as specified and directed by Engg- in- Charge.

1333

-

-

... More
All as per srl item No 07 here-in-before but using old un-reinforced precast concrete cable cove complete all as specified and directed by Engg- in- Charge.

889

-

-

... More
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engg- in- Charge of the following sizes:- Note - Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.

-

-

-

... More
16 Sqmm 4 core

1200

-

-

... More
25 Sqmm 4 core

200

-

-

... More
35 Sqmm 4 core

500

-

-

... More
50 Sqmm 4 core

400

-

-

... More
70 Sqmm 4 core

700

-

-

... More
95 Sqmm 4 core

800

-

-

... More
120 Sqmm 4 core

400

-

-

... More
185 Sqmm 4 core

250

-

-

... More
240 Sqmm 4 core

200

-

-

... More
300 Sqmm 4 core

200

-

-

... More
400 Sqmm 4 core

150

-

-

... More
630 Sqmm 4 core

50

-

-

... More
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engg- in- Charge of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.

-

-

-

... More
95 Sqmm 3 core

50

-

-

... More
120 Sqmm 3 core

80

-

-

... More
185 Sqmm 3 core

120

-

-

... More
240 Sqmm 3 core

150

-

-

... More
300 Sqmm 3 core

100

-

-

... More
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engg- in- Charge. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.

25

-

-

... More
All as per item Ser No 11 above but 1100 Volt LT cables acomplete all as specified and directed by Engg- in- Charge.

35

-

-

... More
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by Engg- in- Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.

100

-

-

... More
All as per item Ser No 13 above but 11000 Volt HT cables complete all as specified and directed by Engg- in- Charge.

70

-

-

... More
M&L for disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by Engg- in- Charge.

20

-

-

... More
Supply, fixing and testing Straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-

-

-

-

... More
25-50 Sqmm x 3.5 core/ 4 core

30

-

-

... More
70-120 Sqmm x 3.5 core

35

-

-

... More
185 -240 Sqmm x 3.5 core

25

-

-

... More
300 -400 Sqmm x 3.5 core

15

-

-

... More
Supply, fixing and testing Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engg- in- Charge of following size :-

-

-

-

... More
95 Sqmm 3 core.

2

-

-

... More
120 Sqmm to 185 Sqmm, 3 core.

2

-

-

... More
240 Sqmm to 300 Sqmm 3 core

2

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engg- in- Charge of following size

-

-

-

... More
95 Sqmm 3 core.

2

-

-

... More
120 Sqmm to 185 Sqmm, 3 core.

2

-

-

... More
240 Sqmm to 300 Sqmm, 3 core.

2

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engg- in- Charge of following size

-

-

-

... More
95 Sqmm 3 core.

6

-

-

... More
120 Sqmm to 185 Sqmm, 3 core.

6

-

-

... More
240 Sqmm to 300 Sqmm 3 core

6

-

-

... More
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 80 to 100mm bore and making good both ends all specified and directed.

79.5

-

-

... More
S&F in replacement GI pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engg- in- Charge of following bore sizes:-

-

-

-

... More
40 mm

12

-

-

... More
50 mm

12

-

-

... More
80 mm

24

-

-

... More
100 mm

18

-

-

... More
S&F cable route indicator made of RCC (Nominal Mix) type B-O, 1:2:4 (Using 12.5mm graded stone aggregate) with 8mm TMT Bar placed 150mm c/c of overall size 1m height x 60cm wide x 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint, with description of HT cable 11kv complete all as specified and directed by Engg- in- Charge Note : Rate for PCC 1:3:6 for foundation (min size 0.8m X 0.3m X 0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the quoted rates.

70

-

-

... More
M&L for cutting and removing grass, vegetation bushes etc from surrounding of transformer,4 pole/6 pole, Lt panels, sub stn surrounding area, in and outside area of HT/LT Sub stn and removing all rubbish to a distance not exceeding 50m complete all as specified and directed by Engg- in- Charge

1000

-

-

... More
Removing the waste building materials at our substation, such as rock, sand, bricks, tiles and mud need to be loaded onto a vehicle and disposed of at a location outside.Its the contractor responsibility to arrange for the disposal site complete all as specified and directed by Engg- in- Charge.

7

-

-

... More
S&F in replacement Air circuit breaker 4pole 1000Amps 65KA with Microprocessor release, manual drawout Adjustable type including dismantling and taking out old unserviceable ACB from panels and fabrication works to BUS bar for proper fitting complete all as specified and directed by Engg- in- Charge.

1

-

-

... More
M&L in replacement of Retro Reflective installation sign boards of size 5 feet x 4 feet fabricated out of 16 guage MS sheet, framed with stainless steel heavy duty pipe of size 50mm bore duly welded/riveted with MS square pipe of size 25mm x 25mm at height 2.00 meter above ground level on stainless steel heavy duty pipe of size 50mm bore embaded 60CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx60cm including necessary excavation and earth work. the steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. the writing matter i.e. details of Substation , location , tele No etc. will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by Engg- in- Charge.

9

-

-

... More
Boring of hole under road , pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine suitable for HDPE pipe of 150mm dia complete all as specified and directed by Engg- in- Charge.

180

-

-

... More
Supply and laying High density polyethene pipes of size of 150mm dia (HDPE) of pressure rating 10kg/cm2 laid in trenches /ducts/bore holes of road crossing /hard standing etc for laying HT cables complete all as specified and directed by Engg- in- Charge.

180

-

-

... More
M&L for Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6mm thick , buried directly in ground (earth pit not less than 2.19m below normal ground level ) with top edge of earth plate not less than 1.5m below normal ground level , connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galavanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized iron sides complete all as specified , including testing and commissioning complete all as specified and directed by Engg- in- Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers , PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcements as in cover & frame for pit, funnel, watering pipe 20mm bore GI pipe light grade, protection pipe 40mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.

10

-

-

... More
S&F in replacement of Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour fixed with MS flat clamps 25x3mm - 2 Nos, nuts, bolts for LT 440 volt of size 20x15cm complete all as specified and directed by Engg- in- Charge.

100

-

-

... More
All as per Srl Item No.30 above but for HT 11000 Volt of size 25x20cm complete all as specified and directed by Engg- in- Charge.

100

-

-

... More
M&L for applying two coats of synthetic enamel paint over steel, wire mesh and iron surfaces or old painted surfaces of any description and clamps, bolts above GL exceeding 10cm width or girth incl preperation of surfaces complete all as specified and directed by Engg- in- Charge.

400

-

-

... More
M&L for Framed work of steel structure GDE Fe410-0 or Fe 310-O as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled or weilded for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engg- in- Charge.

350

-

-

... More
S&F chainlink fencing PVC coated green colored 4mm dia galvanised steel wire with 150x100mm mesh size, made up into mattresses or cages, lapped, wired and laid in position, including closing after fixing complete all as specified and directed by engr-in-chareg.

100

-

-

... More
S&F service connection with PVC insulated and PVC sheathed flat twin core cable 1100V grade heavy duty electric cable served all PVC sheathed in service connections suspendedsuspension wire and loop insulators and as directed of size 10 Sqmm cross sectional area stranded aluminium conductor.

1270

-

-

... More
M&L for spreading of stone aggregate of normal size not more than 25mm under 4/6 pole HT structure/surrounding area of outdoor RMU manually without damaging any equipments, cable or parts, spreading & levelling of finished gravel uniformly in layers not exceeding 15cm thick watered and rammed to true surface complete all as specified and directed by Engg- in- Charge.

11.9

-

-

... More
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.