Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Jan 2025
Closing DateCancelled
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per ser items No. 1.00 here-in-before but model VXF 31.5+ SKD 62 size 50 mm bore complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per ser items No. 1.00 here-in-before but model VXF 31.65+ SKD 62 size 65 mm bore complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per ser items No. 1.00 here-in-before but model VXF 31.80+ SKD 62 size 80 mm bore complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and lay MS pipe pipe in replacement 20 mm bore heavy grade with all fittings laid in floors or fixed to walls and ceiling includig Tee/ Bend/ reducer/Union/ Elbow/socket/Plug and cutting/welding / brazing /drilling of wall /grouting /finishing disturbed surface and taking down old unserrviceable MS Pipe from existing position etc complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 25 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 32 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 40 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 50 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 65 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 80 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 100 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 125 mm bore complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 7.00 here-in-before but 150 mm bore complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
All as per ser items No. 7.00 here-in-before but 200 mm bore complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
M&L in replacement of Insulation for M S pipe with PUF slab 30 mm thick with and including applying bituminous compound and GI cladding with 26 guage GI sheet complete of size 20 mm dia including taking down unserviceable insulation in any description from original position and throwing it to salvage area complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but 25 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but 32 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but 40 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but 50 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but 65 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but PUF slab 40 mm thick 80 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but PUF slab 40 mm thick 100 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but PUF slab 40 mm thick 125 mm dia complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per ser items No. 18.00 here-in-before but PUF slab 40 mm thick 150 mm dia complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
All as per ser items No. 18.00 here-in-before but PUF slab 40 mm thick 200 mm dia complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply, and fixing in replacement of cast Iron butterfly valve, ISI marked, PN - 1.6 pressure grade, having Nitrile/EPDM rubber lining, SS stem,CS/SS disc. Lever operated type, of size 50 mm dia bore including all jointing material i.e, nut, bolt, washer, packing , flanges material etc, duly insulated and taking out of old unserviceable valve complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser items No. 29.00 here-in-before but 65 mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser items No. 29.00 here-in-before but 80 mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser items No. 29.00 here-in-before but 100 mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser items No. 29.00 here-in-before but 125 mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser items No. 29.00 here-in-before but 150 mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per ser items No. 29.00 here-in-before but 200 mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Removing old unserviceable port Y strainer and material and labour for Y strainer 150mm size of both end flanged including supply and welding flange of size 150mm two nos complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Removing old unserviceable port Y strainer and material and labour for Y strainer 100 mm size of both end flanged including supply and welding flange of size 100 mm two nos complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Taking down carefully existing false ceiling of any type / make / size including all electric fitting/fixture, fire alarm and any other accessories etc for repair/replacement of AC duct and refixing the same in its original position with out any damage complete all as specified and directed by Engr-in-Charge. Note : If, any kind of damage occured to false ceiling and other services like elcetric supply cable / fitting / fixture, fire alarm, water supply line or any other services, due to negligance or poor workmenship of contractor, the same will be repaired/replaced by the contractor free of cost and no extra payment will be made in this effect to the contractor.

120

-

-

... More
M&L in replacement for seamless calcium silicate 12mm made out of 1800 X 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long sel drilling and tapping screws having philips headwidth under head cutter at 200mm centre to centre including finishing the joint of face board with specially formulated jointing compound and 48mm wide fiber tape to provide seamless finish complete all as specified and directed by Engr-in-Charge.

110

-

-

... More
S&F of thermal insulation on new / existing ducts and plenum chamber, comprise of preparation of surface and fixing of new cross linked closed cell polythene, plane, fire retardant insulation of 20 mm thick nitrile insulation with aluminium foil of the duct having a tow stable K value of 0.027-0.029 Kcal/hr/m at 0-23°C with minimum density of 33 Kg/cum, fire retardant self extinguishing on dripping, good ozone resistance, including fixing the insulation to the duct surface with help of adhesive paste and closing the gap with self adhesive tape of 3mm thick, complete all as specified and directed by Engr-in-Charge.

700

-

-

... More
S & F in repair of motorised fire damper of various capacity , fabrication with 22 gauge GI Sheet of any dimension including all fixing arrangment like nut/ bolt/ washer or any modification at site requirment incl all necessary electrical control wiring and power point for operation of same, and taking down old unserviceable damper complete all as specified and directed by Engr-in-Charge.

25

-

-

... More
Supply, installation, testing & commissioning in replacement LT panel board In door type, wall mounted of suitable size for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of CRCA sheet outer box thickness 2.0 mm, side covers with hinged doors & proper locking arrangement, rubber gasket on front and back door to make it dust and vermin proof, powder coated , The cubicle shall have control wiring with minimum size: 1.5 SQmm of copper cable including M&L for fixing / grouting the panel to wall and required cable connection with necessary double compression brass gland and cable end sockets, complete comprising of following accessories all as specified and any other items required for smooth functioning of VFD starter Panel is deemed to be included in the rate quoted for the items and as directed by the Engr-in-charge.( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job.) also having built in single phase preventer for 5 HP capacity fan motor complete with following specifications:- INCOMING (i) MCB 25A 10kA (incoming)-01 No. (ii) Ammeter, Voltmeter and CTs- 01 set (iii) RYB indicating lamps LED type- 03 Nos (iv) MCB SP 6A -03 Nos

2

-

-

... More
OUTGOING (i) FASD Starter 5 HP -01 No. (ii) Contactor 3P 12 A -03 No. (iii) O/L relay 6-10A -01 No. (iv) ON-TRIP indicator - 02 No. (v) Start/stop push button - 02 No. (vi) MCB SP 6A,10kA- 01 No (vii) Add on Aux Block 1 NO + 1 NC - 02 set (viii) Single Phase Preventer - 01 No (ix) Auto manual selector switch - 01 No. (x) Star Delta Timer - 01 No. (xi) Variable Frequency Drive suitable for 5 HP motor -01 No.Make:- Danfoss (xii) Glass relay 5 A, 11 PIN -01 No. (xiii) Control Wiring, busbar,nut, bolts, washers , auxillary contacts etc alongwith all misc connected items are deemed to be included in quoted rate. Note:- Contractor need to submit drawing of panel alongwith bill of quantities for approval before starting execution of work

-

-

-

... More
Supply, installation, testing & commissioning in replacement LT panel board In door type, wall mounted of suitable size for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of CRCA sheet outer box thickness 2.0 mm, side covers with hinged doors & proper locking arrangement, rubber gasket on front and back door to make it dust and vermin proof, powder coated , The cubicle shall have control wiring with minimum size: 1.5 SQmm of copper cable including M&L for fixing / grouting the panel to wall and required cable connection with necessary double compression brass gland and cable end sockets, complete comprising of following accessories all as specified and any other items required for smooth functioning of VFD starter Panel is deemed to be included in the rate quoted for the items and as directed by the Engr-in-charge.( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job.) also having built in single phase preventer for 10 HP capacity fan motor complete with following specifications:- INCOMING (i) MCB 32A 10kA (incoming)-01 No. (ii) Ammeter, Voltmeter and CTs- 01 set (iii) RYB indicating lamps LED type- 03 Nos (iv) MCB SP 6A -03 Nos

3

-

-

... More
OUTGOING (i) FASD Starter 10 HP -01 No. (ii) Contactor 3P 22 A -03 No. (iii) O/L relay 9-15A -01 No. (iv) ON-TRIP indicator - 02 No. (v) Start/stop push button - 02 No. (vi) MCB SP 6A,10kA- 01 No (vii) Add on Aux Block 1 NO + 1 NC - 02 set (viii) Single Phase Preventer - 01 No (ix) Auto manual selector switch - 01 No. (x) Star Delta Timer - 01 No. (xi) Variable Frequency Drive suitable for 10 HP motor -01 No. Make - Danfoss (xii) Glass relay 5 A, 11 PIN -01 No. (xiii) Control Wiring, busbar, nut, bolts, washers , auxiliary contacts etc alongwith all misc connected items are deemed to be included in quoted rate. Note:- Contractor need to submit drawing of panel alongwith bill of quantities for approval before starting execution of work

-

-

-

... More
Supply, installation, testing & commissioning in replacement LT panel board In door type, wall mounted of suitable size for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of CRCA sheet outer box thickness 2.0 mm, side covers with hinged doors & proper locking arrangement, rubber gasket on front and back door to make it dust and vermin proof, powder coated , The cubicle shall have control wiring with minimum size: 1.5 SQmm of copper cable including M&L for fixing / grouting the panel to wall and required cable connection with necessary double compression brass gland and cable end sockets, complete comprising of following accessories all as specified and any other items required for smooth functioning of VFD starter Panel is deemed to be included in the rate quoted for the items and as directed by the Engr-in-charge.( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job.) also having built in single phase preventer for 15 HP capacity fan motor complete with following specifications:- INCOMING (i) MCB 32A 10kA (incoming)-01 No. (ii) Ammeter, Voltmeter and CTs- 01 set (iii) RYB indicating lamps LED type- 03 Nos (iv) MCB SP 6A -03 Nos

4

-

-

... More
OUTGOING (i) FASD Starter 15 HP -01 No. (ii) Contactor 3P 25 A -03 No. (iii) O/L relay 14-23A -01 No. (iv) ON-TRIP indicator - 02 No. (v) Start/stop push button - 02 No. (vi) MCB SP 6A,10kA- 01 No (vii) Add on Aux Block 1 NO + 1 NC - 02 set (viii) Single Phase Preventer - 01 No (ix) Auto manual selector switch - 01 No. (x) Star Delta Timer - 01 No. (xi) Variable Frequency Drive suitable for 15 HP motor -01 No.Make- Danfoss (xii) Glass relay 5 A, 11 PIN -01 No. (xiii) Control Wiring, busbar,nut, bolts, washers , auxillary contacts etc alongwith all misc connected items are deemed to be included in quoted rate. Note:- Contractor need to submit drawing of panel alongwith bill of quantities for approval before starting execution of work

-

-

-

... More
Supply, installation, testing & commissioning in replacement LT panel board In door type, wall mounted of suitable size for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of CRCA sheet outer box thickness 2.0 mm, side covers with hinged doors & proper locking arrangement, rubber gasket on front and back door to make it dust and vermin proof, powder coated , The cubicle shall have control wiring with minimum size: 1.5 SQmm of copper cable including M&L for fixing / grouting the panel to wall and required cable connection with necessary double compression brass gland and cable end sockets, complete comprising of following accessories all as specified and any other items required for smooth functioning of VFD starter Panel is deemed to be included in the rate quoted for the items and as directed by the Engr-in-charge.( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job.) also having built in single phase preventer for 7.5 HP capacity fan motor complete with following specifications:- INCOMING (i) MCB 32A 10kA (incoming)-01 No. (ii) Ammeter, Voltmeter and CTs- 01 set (iii) RYB indicating lamps LED type- 03 Nos (iv) MCB SP 6A -03 Nos

2

-

-

... More
OUTGOING (i) FASD Starter 7.5 HP -01 No. (ii) Contactor 3P 18 A -03 No. (iii) O/L relay 9-15A -01 No. (iv) ON-TRIP indicator - 02 No. (v) Start/stop push button - 02 No. (vi) MCB SP 6A,10kA- 01 No (vii) Add on Aux Block 1 NO + 1 NC - 02 set (viii) Single Phase Preventer - 01 No (ix) Auto manual selector switch - 01 No. (x) Star Delta Timer - 01 No. (xi) Variable Frequency Drive suitable for 7.5 HP motor -01 No.Make:- Danfoss (xii) Glass relay 5 A, 11 PIN -01 No. (xiii) Control Wiring, busbar,nut, bolts, washers , auxillary contacts etc alongwith all misc connected items are deemed to be included in quoted rate. Note:- Contractor need to submit drawing of panel alongwith bill of quantities for approval before starting execution of work Note for Ser Item No. 42 .00 to 45.00:- Panel to be manufactured by OEM only mentioned in list of Makes in PS, no authorized dealers will be entertained. Contractor need to submit the drawing for approval of GE.

-

-

-

... More
M&L for control wiring with 3 core X 4sqmm copper Sheilded wire, twisted pair & Sheilded 3 Core Sheathed Wire, Sheilding user Earthing Connection, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
M&L for applying two coats of synthetic enamel paint on any kind of metal surface with and incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer complete all as specified and directed by Engr-in-Charge.

60

-

-

... More
M&L in replacement, for PVC fins Box suitable for cooling tower of 350 TR capacity, FRP induced draft type (Model : CM-12) complete all as specified and directed by Engr-in-Charge.

312

-

-

... More
M&L for wire netting of galvanised steel wire alongwith suitable frame 1.40mm dia with size of mesh 20mm complete all as specified and directed by Engr-in-Charge.

17

-

-

... More
Design, supply, installation, and commissioning of SEMI -HYBRID HEPA class ( polarization based ) central air purification system using Filterless Magnetic Air Purification Process of different capacities inside AHU to improve the air quality by removing microbial, pollution inside the air. The air purification system must be IS 17570:2021 : ISO16890:2016 certified in accordance to ASHRAE 52.2 2017 with valid test data by ASHRAE validated lab having in USA only. It should be a monobloc-structured unit specifically designed for integration in the Return Air path of units of all sizes, to centrally capture and kill germs. It shall be in grids of sizes 610x370x150mm (1000 CFM), and 610x680x150 mm (2000 CFM) to cover the full capacity (CFM) of the units. The central air cleaner unit should have no consumable parts and the minimum life of central air cleaner unit should be more than 10 years. The central air cleaner shall be capable of removing particulates as small as 0.01 microns including particulate matter PM 2.5 & PM 1.0, allergens, pollen, bacteria, pathogens and various VOC.

-

-

-

... More
• It must be a monobolic-structured unit specifically designed for integration in return air path of air delivery systems to provide a single indoor air quality (IAQ) solution meeting global safety and performance standards set forth by ISHRAE, GRIHA, IGBC, CDC , ASHRAE & CPCB Notification No B-29016/20/90/PCI-L Manufacturer must comply with DIPP guidelines for public procurement policy notification No REGD No. DL-33004/99 dated 21 July2006 & Micro and Small Enterprises (MSEs) Order, 2012 inline with make in India initiative. For ease of supply and spares the OEM must have manufacturing facilities in India/Delhi NCR and support MAKE In India initiative. The OEM must strictly follow DIPP guidelines, Green Pro for more than 50 % Indian components and OEM registered under MSME will be given preference. Supplier must have experience of more than six years 'executing projects with the same technology products and have successful installation in CPWD / PWD hospitals/governments project. List of project need to be submitted for approval.

-

-

-

... More
• The central air cleaner must be designed to trap and kill microbes with high efficiency duly tested on E. coli (ATCC 15597), H1N1, as per ASTM E2149 with no less than 99% killing in less than 15 minutes. • The unit shall be UL2998 (that does not produces ozone, ozone generation shall be less than 50 ppb from an International Lab) & Intertek ETL, UL 867, CSA C22 No. 187, and CE certified for safety and quality and with EMC (Electromagnetic compatibility), LVD (Low Voltage directive) and RoHS compliant for complete modules The failure to submittal the certifications along with the submital shall lead to rejection of the product. • For safety & security no arching, popping noise should occur during dust test. Also there should be no residual charge to avoid any shock risks. • The system should have a UL certified inbuilt pneumatic sensor allowing it to work as a controller (optional). It must automatically detect airflow and the capability to interface with the building management system. If the HVAC system is turned ON and the airflow is detected, then the output power should be available to the system, otherwise the system shall automatically turn off for the protection of service personnel. AHU 6000 CFM Note:- Contractor need to submit the drawing for approval of GE.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.