Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Sep 2024
Closing Date28 Oct 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per ser item No. 2 but comprising the following.(Loc- MNS Mess) (i) 600 A aluminium bus bar TPN system. (ii) Digital and programmable multifunction meter for all parameter with 03 Nos CT's of suitable capacity - 01 No (iii) LED indication lamp RYB with toggle switch for phase indication- 01 Set of three (iv) Change over switch ON load 400 Amps, 4 Pole, AC, 50 Hz, 415 Volt -01 (Incomer) (v) MCCB 4 Pole 415 volts AC 50 Hz 400 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Incomer) (vi) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Outgoing) (vii) MCCB 4 Pole 415 volts AC 50 Hz 160 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release - 05 No (Outgoing) (viii) MCCB 4 Pole 415 volts AC 50 Hz 100 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release - 04 No (Outgoing)

1

-

-

... More
All as per ser item No 2 but comprising the following.(Loc- Sainik Niwas) (i) 400 A aluminium bus bar TPN system. (ii) Digital and programmable multifunction meter for all parameter with 03 Nos CT's of suitable capacity - 01 No (iii) LED indication lamp RYB with toggle switch for phase indication- 01 Set of three (iv) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Incomer) (v) MCCB 4 Pole 415 volts AC 50 Hz 100 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release - 06 No (Outgoing)

1

-

-

... More
All as per ser item No. 2 but comprising the following.(Loc- X block substn for Medical store) (i) 600 A aluminium bus bar TPN system. (ii) Digital and programmable multifunction meter for all parameter with 03 Nos CT's of suitable capacity - 01 No (iii) LED indication lamp RYB with toggle switch for phase indication- 01 Set of three (iv) Change over switch ON load 400 Amps, 4 Pole, AC, 50 Hz, 415 Volt -01 (Incomer) (v) MCCB 4 Pole 415 volts AC 50 Hz 400 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Incomer) (vi) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 02 No (Outgoing) (vii) MCCB 4 Pole 415 volts AC 50 Hz 200 Amps 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Outgoing) (viii) MCCB 4 Pole 415 volts AC 50 Hz 100 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Outgoing)

1

-

-

... More
All as per ser item No. 2 but only front side openable and comprising the following.(Loc- Bldg No P- 21, P- 22 & P- 49) (i) 400 A aluminium bus bar TPN system. (ii) Digital and programmable multifunction meter for all parameter with 03 Nos CT's of suitable capacity - 01 No (iii) LED indication lamp RYB with toggle switch for phase indication- 01 Set of three (iv) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Incomer) (v) Space and fixing arrangement for 1ph meter with double pole MCB 63 Amp, B Curve, 10 KA - 15 No (Outgoing)

3

-

-

... More
All as per ser item No. 2 but comprising the following.(Loc- Medical Store) (i) 600 A aluminium bus bar TPN system. (ii) Digital and programmable multifunction meter for all parameter with 03 Nos CT's of suitable capacity - 01 No (iii) LED indication lamp RYB with toggle switch for phase indication- 01 Set of three (iv) Change over switch ON load 400 Amps, 4 Pole, AC, 50 Hz, 415 Volt -01 (Incomer) (v) MCCB 4 Pole 415 volts AC 50 Hz 400 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Incomer) (vi) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 03 No (Outgoing) (vii) MCCB 4 Pole 415 volts AC 50 Hz 100 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Outgoing)

1

-

-

... More
All as per ser item No 2 but indoor type, made out of 2.00 mm thick CRCA MS sheet, front openable and comprising the following.(Loc- ADC Near stair case Panel-1 & 2) (i) 600 A aluminium bus bar TPN system. (ii) Digital and programmable multifunction meter for all parameter with 03 Nos CT's of suitable capacity - 01 No (iii) LED indication lamp RYB with toggle switch for phase indication- 01 Set of three (iv) MCCB 4 Pole 415 volts AC 50 Hz 400 Amps, 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 01 No (Incomer) (v) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps 36 kA, Ics= 100% Icu, adjustable thermal magnetic release - 03 No (Outgoing) (vi) MCCB 4 Pole 415 volts AC 50 Hz 100 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release - 03 No (Outgoing) (vii) MCCB 4 Pole 415 volts AC 50 Hz 63 Amps 16 kA, Ics= 100% Icu, adjustable thermal magnetic release- 02 No (Outgoing)

2

-

-

... More
M&L in replacement of plate earthing complete with galvanized mild steel plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically (in earth pit not less than 2.25m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5m below norm al ground level, the earth electrode surrounded by adequate quantity of clear coal dust and salt to a packed thickness of 15cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and revetted to earth plate at one end and connected to metallic bodies of equipments etc, GI earth strip encased in and including 40 mm bore GI medium grade pipe with all fittings from upper edges of earth plate to body of equipment fixed with and including 32 x 6 mm flat iron clamps,bolts, nuts and washer and also including providing 20 mm bore GI pipe medium grade from bottom of earth plate to ground level for watering complete with earth pit in PCC 1:2:4 type B-O using 12mm graded crushed stone aggregate and RCC cover, funnel, wire mesh including necessary excavation & earth work, etc as shown on electrical plate No 3 of SSR Part I complete all as specified and directed. Note: (i) Rate included for Adequate quantity of charcoal dust, common salt and Testing commissioning including checking of earth continuity and earth result complete all as specified and as directed. (ii) Rates for Main earthing lead from earth electrode to test point upto 7.5 metre will deemed to be included in quoted rates. (iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.

22

-

-

... More
M & L for 32x6mm galvanised iron strip as Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required & complete as specified and directed.

30

-

-

... More
M&L for taking down old U/S cable from wall/trench/roof any height and Supply, laying (laying in ducts/trenches/on walls/ fixing on existing cable tray with new saddles & clamps etc as per site requirement), jointing, testing and commissioning with new XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm x 3.5 Core in trench/ on pole/ in duct complete all as specified and directed. Note:-1. The cost of AI thimbles / lugs/clamps/fastner and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning, cable cover and Cable joints will be measured and paid separately under respective items of this sch.

100

-

-

... More
All as per srl item No 12 here-in-before but 95 sqmm x 3.5 Core.

100

-

-

... More
All as per srl item No 12 here-in-before but 150 sqmm x 3.5 Core.

100

-

-

... More
All as per srl item No 12 here-in-before but 240 sqmm x 3.5 Core.

100

-

-

... More
All as per srl item No 12 here-in-before but 400 sqmm x 3.5 Core.

100

-

-

... More
Bringing fault detector machine with skilled tradesmen to detecting the fault by inducing the high potential in any sizes of LT cables and marked the place where fault detected and testing after rectifying the fault all as directed.

5

-

-

... More
Material and labour for Heat shrinkable LT 1.1 KV straight through joint suitable for aluminium cable of Size 300 Sqmm to 400 Sqmm x 3.5 core all as specified .

3

-

-

... More
Ditto all as per item No 18 but for 185 Sqmm to 240 sqmm x 3.5 core .

3

-

-

... More
Ditto all as per item No 18 but for 70 Sqmm to 150 sqmm x 3.5 core .

3

-

-

... More
Ditto all as per item No 18 but for 25 Sqmm to 50 sqmm x 3.5 core .

2

-

-

... More
Excavating in trenches in soft / loose soil, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out complete all as specified and directed.

72

-

-

... More
Material and labour for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches complete all as directeld and sand cover to under ground cable complete all as directed. Note : The penned thickness of sand shall be considered for measurement purpose.

24

-

-

... More
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all specified and directed.

2.61

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.

38

-

-

... More
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.

34

-

-

... More
Material & Labour for road cutting, including excavation, returning filling in, spreading, leveling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work to match with the existing road, complete all as directed.

12

-

-

... More
S&F in replacement of GI pipe of 100 mm nominal dia light grade with all fittings laid in trenches or under road crossing or fixed to walls/poles with clamps nuts, bolts and washers complete all as specified and directed.

6

-

-

... More
All as per srl item No 28 here-in-before but for GI pipe of 80 mm dia size.

6

-

-

... More
Supply and fixing in replacement of MCCB, four pole, 415 volts, adjustable type of capacity 100 Amps, 16 KA, Ics= 100% Icu, adjustable type thermal- magnetic release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections in LT panel / Tap off box including taking down old unserviceable MCCB, complete all as directed.

2

-

-

... More
All as per items No. 30 here-in-before but 125 Amp, 16 KA capacity

4

-

-

... More
All as per items No. 30 here-in-before but 160 Amp, 36 KA capacity

2

-

-

... More
All as per items No. 30 here-in-before but 200 Amp, 36 KA capacity

2

-

-

... More
All as per items No. 30 here-in-before but 250 Amp, 36 KA capacity

2

-

-

... More
All as per items No. 30 here-in-before but 400 Amp, 36 KA capacity

1

-

-

... More
All as per items No. 30 here-in-before but 630 Amp, 50 KA capacity

1

-

-

... More
Attending breakdown / inspection of LT ACB of any make EDO / MDO type and rating 630 Amps to 2500 Amps as per existing make and model by authorised service engineer to check and replace any spares related breakdown & making the ACB serviceable complete all as specified and as directed. (i) All Measuring equipments, T&P and Any other minor or major items required for smooth functiong of ACB will have to be arranged by Contractor himself and for this purpose no extra cost will be paid.

3

-

-

... More
M&L for painting of old painted surface of LT panels/ busbar chamber/ MS support structure by cleaning internally & externally, brushing / scraping rusted surface cleaning stains & grease spots with thinner & sand paper and preparing the surface for painting the cleaned surface with two (02) coat of synthetic enamel paint to achieve good finish by spray painting machine carefully and covering the meters, indicators, relays and switches to prevent from fall of paint drops on the panels including writing, number, letter etc if req on newly painted surfaces complete all as specified and as directed. Note:- The shade of paint will be decided by Engr-in-Charge & no extra payment will be paid on this account.

100

-

-

... More
S&F in replacemnet of tap off box enclosure metal body type with provision of interlock to prevent removal when outgoing device is in ‘ON’ position and with provision of interlock to prevent turned 'ON' MCCB When the tap-off unit cover is ‘OPEN’, suitable for aluminium busbar trunking upto capacity 800 Amps, 3 phase, 4 wire including suitable neutral link & glands and MCCBs of ratings from 400 Amps, 4 pole, 36 kA, Ics=Icu Thermal magnetic release type complete of existing make, cat part number and must be compatible with existing BBT system complete all as per site requirement & as directed by Engr In Charge.

4

-

-

... More
Taking LT supply shut down & disconnecting cable from input / out put terminal and Servicing & overhauling by dismantling the complete unit of Automatic Voltage stabilizer of capacity 200 KVA to 300 KVA oil cooled type three phase 415 Volt 50 Hz. Servicing by cleaning and segregating of mechanical mechanism of operation, taking out oil from Pan, Cleaning of inner surface of tank & taking out sludge, carrying out repair for making voltage stabilizer serviceable including replacement of all minor & major worn out parts , checking all check points/ terminal points, tunning of circuit, repair of control card, servicing of synchronous motor, replacement of nut bolt of required Nos, refilling & top up of transformer oil after dehydration etc, assembling, connecting to electric supply and testing on full load up to entire satisfaction complete all as specified and as directed. Note:- Any other activity, all minor or major items not listed / covered here above and required during / completing the work for smooth functiong of system will have to be arranged by Contractor himself and for this purpose no extra cost will be paid.

1

-

-

... More
S&F in replacemnet of on load changeover switch 400 Amp, 415 V AC, 4 Pole with all accessories and to be fix in existing panel / enclosoure complete all as specified and directed.

1

-

-

... More
S&F in replacemnet of on load changeover switch 400 Amp, 415 V AC, 4 Pole with all accessories including sheet steel enclosure complete all as specified and directed.

1

-

-

... More
S&F in replacemnet of on load changeover switch 200 Amp, 415 V AC, 4 Pole with all accessories including sheet steel enclosure complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of automatic transfer switch (ATS) of 200 Amps capacity, 04 pole, 415 volt, 50 Hz having automatic/manual control with inbuilt time delay, protection against single phasing, over voltage, under voltage and inbuilt phase correction, with steel enclosure complete with all accessories, complete all as directed.

1

-

-

... More
Attending breakdown /inspection of automatic transfer switch (ATS) / on load changeover switch of capacity upto 630 Amps, 04 pole, 415 volt, 50 Hz to check, repair and replace any spares related breakdown to make them serviceable complete all as specified and as directed.

2

-

-

... More
M&L for servicing of Automatic Power Factor Control (APFC) Panel of any capacity & make for making serviceable and smooth functioning of automatic switching of capacitor banks. servicing by cleaning of complete panel with electric blower, checking all check points/terminal points, checking complete control wiring & power cable connecting to main incoming also with capacitor to heavy duty contactor and including cable tray for carrying the wires, din rail for melamine complete to the operation of APFC relay, ammeter, voltmeter, LED indicator etc, carrying out repair for making APFC panel serviceable including replacement of all minor & major worn out parts, rewiring wherever required with using 2.5 sqmm, FRLS, multistranded PVC insulated unsheathed copper cable, tunning of circuit, repair of APFC relay, duty contactor & capacitor banks, servicing of ventilating fan, replacement of nut bolt / door hinges as required and any other spare which is required to make panel fully automatic switching of capacitor banks including taking out of old wiring/worn out spare parts & testing up to entire satisfaction complete all as specified and as directed. Note:- 1. The cost of control cable, minor spare parts required for making serviceable and smooth functioning of APFC panel deemed to be included in quoted rate and no extra payment will be made for it. 2. Major spare parts shall be measured and paid seperately under respective items as supply only. 3. Any other activity / minor items not listed/covered here above and required during /completing the work for smooth functiong of system will have to be arranged by Contractor himself and for this purpose no extra cost will be paid. 4. Sevicing of APFC panels shall be carried out by OEM or their authorised dealer only

15

-

-

... More
Supply only in replacement of micro controller automatic power factor control relay, 415 volts, 50Hz, suitable for APFC Panel upto 8 stage off different capacities and making all connection in existing panel complete all as specified & directed.

2

-

-

... More
Supply only in replacement of micro controller automatic power factor control relay, 415 volts, 50Hz, suitable for APFC Panel 12 stage off different capacities and making all connection in existing panel complete all as specified & directed.

2

-

-

... More
Supply only in replacement of capacitor duty contactor suitable for capacitor of capacity upto 25 kVAR, 415V, AC, 3ph, 50Hz, with built-in-auxiliary contacts and making all connection in existing panel complete all as specified & directed.

4

-

-

... More
All as per ser item No. 49 here-in-before but 50 kVAR, 415V, AC, 3ph, 50Hz.

3

-

-

... More
Supply only in replacement of MPP heavy duty box / cylindrical type (resin filled) capacitor of upto 25 kVAr Capacity, 415 Volt, 50Hz, 3 phase and making all connection in existing panel complete all as specified & directed.

5

-

-

... More
All as per srl item No. 51 here-in-before but 50 KVAr capacity.

4

-

-

... More
Supply only in replacement of 7% detuned copper wound reactor of capacity upto 25 KVAr Capacity and making all connection in existing panel complete all as specified & directed.

2

-

-

... More
All as per srl item No. 53 here-in-before but up to 50 KVAr capacity.

2

-

-

... More
Supply only in replacement of fan of 150 mm sweep size, 230 v, 50 Hz AC, alongwith filter & thermostate switch to disipate the heat librated by the capacitor bank installed in APFC panel complete with automatic switching ON / OFF of fan depending upon the temperature alongwith control wiring for the ventilating fan in the panel including all necessary arrangement for proper fixing & functioning of fan and system complete all as specified and directed.

1

-

-

... More
Attending breakdown / inspection of automatic power factor control (APFC) panel of any capacity and make to check, repair and replace any spares related breakdown to make the system serviceable complete all as specified and as directed. Note for item No 1 to 56 :- (i) It is not mandatory to hand over the work site/ bldg to the Cotractor in one stretch. (ii) It may be handed over in peace-meal as and when the site/ bldg are vacated or shut down given by the user including Sunday/ Holiday/ Night hours Contractor shall make/ changes the execution plan accordingly. Any claim what so ever on this account shall not be admissible. (iii) Rate quoted by the Contractor shall be deemed to include on this account.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.