Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 92,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Special Repair Replacement Of Lt Xlpe Cable Lt Panel Bus Bar Chamber Street Light Poles And Connected Em Items In Rr Colony Under Ge U Elect Supply Delhi Cantt10
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684473_1Tender No
GE ELECT/D-68/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge.
Note : Measurement shall be taken after punning down.
1100.96
-
-
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
28.36
-
-
All as per srl item No 5 here-in-before but using old bricks complete all as specified and directed by Engineer- in- Charge.
7.09
-
-
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed. Cables of the following sizes:-
Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
-
-
-
16 Sqmm 4 core
1780
-
-
35 Sq mm 3.5 core.
300
-
-
95 Sq mm 3.5 core.
950
-
-
120 Sq mm 3.5 core.
300
-
-
185 Sq mm 3.5 core.
850
-
-
300 Sq mm 3.5 core.
350
-
-
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr- in- Charge.
30
-
-
M&L in replacement of GI tubes of size 80 mm dia (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engr- in- Charge.
12
-
-
M&L in replacement of GI tubes of size 50 mm dia (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engr- in- Charge.
18
-
-
S&F in replacement for MCCB 160 Amp, 4 pole , 25 KA, 50 Hz with MCCB sheet metal enclosure mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU complete all as specified and directed by Engr- in- Charge.
12
-
-
M&L for earthing complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer- in- Charge.
8
-
-
S&F in replacement of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified and directed by Engineer- in- Charge.
25
-
-
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer complete all as specified and directed by Engineer- in- Charge.
25
-
-
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck type pole 9 mtr long complete with mild steel base plate, finial taper plug, bolts, nuts and screws including two coats of aluminium painting over a coat of primer for exposed surfaces and two coats of bituminous black paint over a coat of primer to the surfaces in contact with concrete inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as specified and directed.
Note:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint complete with cast iron base plate complete all as specified and directed by Engr- in- Charge.
15
-
-
Supply, drawing, connecting & testing of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 on steel tubular pole/PCC Pole from KIOSK box to light fittings including PVC conduit and providing suitable copper lugs complete all as specified and directed by Engineer- in- Charge.
110
-
-
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The fixing of double doors shall be on MS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following complete all as specified and directed by Engr- in- Charge. :- (a) Incoming:-
(i) ACB 4 pole , 800 Amps,50 Hz,415 Volts, 50 KA, with microprocessor release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 1600 Amps- set of four
1
-
-
(b) Outgoing:-
(i) MCCB 4 pole, 400 Amps,50 Hz,415 Volts, 36 KA with thermal magnetic release - 01 Nos
(ii) MCCB 4 pole, 320 Amps,50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos
(iii) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos (c) Platform of Panel:- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-
(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
-
-
-
All as in item No 17 here-in-before but comprising of the following (a) Incoming:-
(i) MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA, with microprocessor release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTs ratio 630/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 1200 A- set of four (b) Outgoing:-
(i) MCCB 4 pole, 250 Amps, 50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos
(ii) MCCB 4 pole, 200 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos
1
-
-
Supplying and installation in replacement factory made and tested (including CPRI type tested certified panel) Timer Panel board ,cubical , out door type , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system . The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and minimum 32x32x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, closing locking arrangement including power wiring with 10 Sqmm PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade and internal wiring with 1.5 Sqmm copper conductor and comprising of the following :-
(i) MCCB 3 pole , 32 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 Pole power contractor, type MNX 110 having 2 NO +2 NC contacts -01 (iii) Digital Astronomical Time switch , 240 Volt AC , 50 Hz -01 No
(iv) Auto /manual selector switch -10 No
(v) Aluminium bus bar 100 Amps, 4 strip 3 phase and neutral 415 volts, 50 Hz, duly insulated with heat shrinkable PVC sleeves- 01 Set
Platform for the timer panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by Engr- in- Charge.
2
-
-
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%