Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690586_1Bid Award Id
ViewTender No
GE/WS/Token-46 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed
23.48
-
-
... More
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-2 (with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface complete all as specified and directed.
2
-
-
... More
Taking up Cast Iron/Ductile Iron/ MS Pipes water mains (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead all as specified and directed by Engr-in-charge of the following sizes :-
(Note:- (a) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of CI/DI/MS pipe in 'RM' and lead in 'KG'shall be taken into account and attach with RAR/F Bill)
(b) Excavation and earth work shall be measured and paid seprately under respective items.
-
-
-
... More
100 mm bore
150
-
-
... More
150 mm bore
100
-
-
... More
200 mm bore
150
-
-
... More
Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ.
Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.
Note3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site.
Note4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.
Note5:- Layout plan for laying of DI pipe shall be given by EIC in writing.
Note6 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates.)
-
-
-
... More
100 mm bore
150
-
-
... More
150 mm bore
100
-
-
... More
200 mm bore
150
-
-
... More
Material and labour for Cast iron bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (both all sockets or socket and spigot or flanged) collars, cast Iron connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in 'RM' shall be taken into account and attach with RAR/F Bill)
160
-
-
... More
M&L for DI specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of 150mm bore confirming to IS: 1538-1993 complete all as specified and directed by Engr-in-Charge of following sizes:- (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of fittings in weight (KG) shall be taken into account and attach with RAR/F Bill)
100
-
-
... More
Taking down old unsv LT XLPE Cable PVC insulated armoured aluminium conductor of any size after taking down from trenches including brick protection & sand cushioning etc complete all as specified and directed by EIC.
(Note:- Old U/s aluminium conductor material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill).
400
-
-
... More
S&F in replacement of LT XLPE PVC insulated armoured aluminium conductor cable 1100 Volts grade of following sizes :-
(Note:- (a) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of CI/DI/MS pipe in 'RM' and lead in 'KG'shall be taken into account and attach with RAR/F Bill)
(b) Excavation and earth work shall be measured and paid seprately under respective items.
-
-
-
... More
35 sqmm, 3.5 Core
150
-
-
... More
50 sqmm, 3.5 Core
150
-
-
... More
70 Sqmm, 3.5 Core
100
-
-
... More
Supply & laying of bricks Sub Class 'B' old size laid across the cable above the sand cushioning for protection of cable complete all as specified and directed.
3200
-
-
... More
Supply & filling of sand cushioning, vegetation free, laid across length width equal to length including watering and consolidation complete all as specified and directed.
(Note: Punned down thickness of sand shall only be taken for measurement & payment.)
10
-
-
... More
M & L for Construction of valves pit chamber having internal dismention 2.20 m x 1.80 m x1.50 m (internal height) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm thick MS top sheet cover in 2 pieces with locking arrangement including 50 mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs including dismentling of existing valve pit complete all as specified and as directed.
(Note:- Old U/s brick & MS work obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of volume in (CUM) and weight in (KG) shall be taken into account and attach with RAR/F Bill)
2
-
-
... More
M&L construction of valves pit chamber having internal dimension 120cmx120cmx120cm (internal height) with PCC sub base in PCC (1:4:8) using 40mm graded crushed stone aggregate for foundation 15cm thick, 23 cm brick wall in cement mortar (1:4) 15mm thick plastering / rendering all around the brick work in cement mortar 1:6 and included PCC (1:2:4) type B1 as in coping with 20mm graded crushed stone aggregate for grouting MS frame incl 3mm thick MS top sheet cover with locking arrangement incl 50mm pad lock with double key arrangement. MS frame made out of 40x40x6mm thick angle iron incl painting of steel surface with two coats of syenthetic enamel paint over a coat of red oxide primer as finishing coat incl necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50 mtrs all as specified and shown on drg No CWE (U)/D-1/86 sheet No 1/1 and includung demolition/ dismentling of existing valve chamber as directed by the Engineer-in-Charge.
(Note:- Old U/s brick & MS work obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of volume in (CUM) and weight in (KG) shall be taken into account and attach with RAR/F Bill)
4
-
-
... More
M&L for painting on steel and iron surfaces with two coat of synthetic enamel paint as per existing colour scheme or pattern after preparation of old painted surface of any description over 10cm in width or girth complete all as specified and as directed by Engr-in-charge
100
-
-
... More
Supply and fixed in replacement neck 11 to 15 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n. exc 10 cm long complete all as specified and directed.
(Note :- Old U/s steel obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
40
-
-
... More
Supply and fixed in replacement for MS joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-W (Gde-E-250) quality B, including applying two coat of synthetic enamel paint over a coat of red oxide primer after preporation of steel surfaces complete all as specified and directed.
(Note :- Old U/s iron scrap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
400
-
-
... More
Fixing only chain link fencing including line wires any mesh, size and type, any standards, rails, straining bolts etc including provision of inding wire including taking down of existing fencing complete all as specified and directed. (Note :- (i) Old U/s fencing obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill.
(ii) Chain link fencing and mild steel round bar shall be measured and paid seperately under respectve items.)
1050
-
-
... More
Supply only 6mm dia mild steel round bar used as line wires for chain link fencing any size complete all as specified and directed.
(Note :- Fixing cost of line wires shall be deemed included in quoted unit rate of item No (15) above i.e. cost of fixing of chain link fencing.)
460
-
-
... More
Supply only GI coated chain link fencing (wire dia not less than 10 BWG) ISI marked of size mesh not less than 75 x75mm complete all as specified and directed.
(Note:- Fixing only charges of chain link fencing shall be deemed included in quoted unit rate under ser item No (15) above.
1740
-
-
... More
Excavation in post holes in hard/dense soil each not exceeding 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50 metre and making good surface complete all as specified and directed.
30
-
-
... More
M&L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
5
-
-
... More
Supply and fix in repair pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed fixed with self taping screws roofing including taking down old unserviceable material complete all as specified.
(Note :- Old U/s galvalume sheet obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
450
-
-
... More
Supply and fix in repair pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed fixed with self taping screws roofing including ridges including taking down old unserviceable material complete all as specified and directed.
(Note :- Old U/s galvalume sheet obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
3
-
-
... More
Supply and fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 including taking down old unserviceable material complete all as specified and directed.
(Note :- Old U/s steel tubular obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
250
-
-
... More
Supply, Laying, Jointing, Welding, Testing and Commisioning of MS Pipe (Heavy Class 'C') as per IS:1239 of following size laid in trenches or in Horizontal/Vertical/Inclined position or laying in floors for connection of suction/delivery line including taking out the old unserviceable pipes complete all as specified and as directed. Notes : (a) MS Flanges and Fabrication work shall be measured and paid separately. (b) Earth work and Joints shall be measured and paid separetely (c) Layout plan for laying of MS pipe shall be given by EIC in writing.
(d) MS pipe whole quantity of tender shall be procured by contractor in one time and the same will be paid in 1st RAR as material laying at site.
(e) Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the MS pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.
(f) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.
-
-
-
... More
80 mm bore
12
-
-
... More
100 mm bore
12
-
-
... More
150mm bore
18
-
-
... More
200 mm bore
12
-
-
... More
300 mm bore
12
-
-
... More
Supplying and fixing, MS flanges of following sizes not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed by Engr-in-Charge. (Note:- Old U/s flange material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
-
-
-
... More
80 mm bore
4
-
-
... More
100 mm bore
4
-
-
... More
150 mm bore
6
-
-
... More
200 mm bore
4
-
-
... More
300 mm bore
4
-
-
... More
M&L for making hole of size 200/150/100 mm with the help of gas cutter and electric driver cutter in MS pipe of size 200 to 450 mm for connection the Pipe line of size 200/150/100 mm bore complete all as specified and directed.
10
-
-
... More
Taking down cement plaster or cement lime plaster on PCC/Stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed .
200
-
-
... More
M&L rendering 15 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed by Engr-in-Charge.
200
-
-
... More
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc complete all as specified and directed.
(Note:- Old U/s brick / brick bats stone / boulder obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of volume in (CUM) shall be taken into account and attach with RAR/F Bill)
30
-
-
... More
M&L Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:6) as in brick pillar of required size and shape to support the post/pillars all as specified and as directed at site by the Engr-in-Charge.
30
-
-
... More
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed.
10
-
-
... More
M&L PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of brick pillar to support the pipe line complete all as specified and as directed at site by the Engr-in-Charge.
10
-
-
... More
Hacking out old broken glass any thickness, size, quality or description from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads including S&F 3 mm thick plain sheet glass ordinary quality in square not exceeding 0.5 complete all as specified and as directed at site by the Engr-in-Charge.
4
-
-
... More
M&L coloured Glazed ceramic tiles in vertical surfaces of size 400mm x 400mm x 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in cm (1:3) including dismentling of existing tiles with screed bed complete all as specified and directed.
130
-
-
... More
Supply and fixing & installation in replacement of perforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging system and other accessories including painting of cable tray of complete all as specified and directed.
(Note:- Old U/s MS cable tray material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
60
-
-
... More
M&L for fabrication (welding work ) of MS Header/ any size upto 300mm MS pipe at various pump house site for connection of pipe , arresting leakges on header complete all as specified and directed.
5
-
-
... More
M&L Machine pressed precast concrete coloured paver block rubberised moulded interlocking paverblocks any shape and size in replacement confirming to IS 15658-2006 of 60 mm thick, M-35 Grade with grey cement and pigments, over 40 mm & including thick sand cushioning complete all as specified and as directed. (Note:- Old U/s material through at low laying area being worthless).
450
-
-
... More
Supply and fixing of rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, triple layered hoisted and fixed in position alongwith lid cover after taking down as existing at site (of any capacity) and removing to store yard at his own arrangement complete all as specified and as directed.
4
-
-
... More
Supply and fixing of rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 1000 ltrs capacity, triple layered hoisted and fixed in position alongwith lid cover after taking down as existing at site (of any capacity) and removing to store yard at his own arrangement complete all as specified and as directed.
4
-
-
... More
Supply and fixing of rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 2000 ltrs capacity, triple layered hoisted and fixed in position alongwith lid cover after taking down as existing at site (of any capacity) and removing to store yard at his own arrangement complete all as specified and as directed. (Note for Item No 37 to 39: (i) For Pump Priming purpose in pump house.
(ii) Old U/s material PVC tank obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of PVC scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.
(iii) Tank shall be provided on PCC (1:2:4) type B-I using 20mm graded crushed stone aggregate ramp of 150mm thick round shape over roof slab or in ground floor over sub base of PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate and top surface of ramp finished even and smooth using extra cement complete the cost of ramp will be deemed included in quoted unit rate.)
2
-
-
... More
M & L in replacement of providing and fixing of post/frame work of stainless steel, grade 304 pipes including braces of stainless steel, plates, angle, flats, tubular sections etc including cutting, hoisting fixing with argon welding, bright finish, buffing polishing etc complete with necessary holes, nuts, bolts, caps and anchor plates of stainless steel as per design provided by Engineer-in-Charge.
(Note:- Old U/s stainless steel obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
1800
-
-
... More
Supplying, fixing and installation in replacement of full cube poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminum composite panel having 0.50mm thick skin of aluminum both side. The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter, message (bi-lingual), symbol and borders etc as per IRC 67-2001. The aluminum composite panel shall be suitably fixed on top, bottom and sides of stainless steel frame work as per directions of Engineer-in Charge. Retro reflective tape shall be of brand : 3M, Avery Denni & the contractor would be required to submit tax paid vouchers of retro reflective tapes used in the work of approved makes complete all as specified and directed.
(Note:- (a) Design/pattern shall be approved by GE.
(b) Old U/s steel / pvc scrap material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
180
-
-
... More
Supplying and fixing in replacement water meter level indicator of approved make electronic type, for over head water tank , reservoir, comprising of twenty stage magnetic sensor concealed in stainless steel tube of required length, multicore cable & features of alarm on low and high levels with indications to make it fully serviceable/ functional at site complete all as specified and as directed.
(Note:- Old U/s steel material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
3
-
-
... More
Supplying and fixing in replacement water meter level indicator of approved make electronic type, for over head water tank , reservoir, comprising of ten stage magnetic sensor concealed in stainless steel tube of required length, multicore cable & features of alarm on low and high levels with indications to make it fully serviceable/ functional at site complete all as specified and as directed.
(Note:- Old U/s steel material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
4
-
-
... More
Supply and fixing in replacement mild steel work for manhole cover, stair case steps, pit chamber cover , doors/gate, fencing on boundary etc made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, including drilling holes, notching for wire etc flat iron fillets including weling work all necessary drilling, bolting or rivetting , PCC work etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed.
(Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
450
-
-
... More
Supply installation, commissioning and testing LT panel outdoor type made out of 3.15 mm thick CRCA sheet (manufactured through CPRI approved manufacturers), floor mounted duly Powder Coated, dust and vermin proof with front opening arrangement with and incl foundation with PCC 1:2:4 type B1, MS channel base frame etc complete comprising of aluminium bus bar of capacity 400 Amps 4 Nos of strip 415 volts and cabinet for housing MCCBs, metering equipments, all accessories prewire with copper cable of suitable capacity including providing danger notice board with boon & skull in florescent paint etc complete all as specified and directed. All MCCBs should be connected with aluminium busbar as per there capacities and comprising of following accessories:-
(i) MCCB 4 pole 160 Amp, rupturing capacity of 50 KA (As In-coming) -01 No.
(ii) MCCB 4 pole100 Amps, rupturing capacity of 36 KA (As Outgoing)-02 Nos
(iii) MCB TP 32 Amps,10 KA-02 Nos
(iv) MCB DP 32 Amps,10 KA-02 Nos
(v) Set of Indicating lamp (one set) set of three.
(vi) Digital type volt meter (0-500 volts) with selector switch - 01 No.
(vii) Digital type Amp meter 0-100 Amps with CT’s & selector switch - 01 No.
(viii) Fully automatic star-delta starter in sheet enclosure type ML-1.5, FASD, relay max range 13-21 Amp including timer relay for automatic start and stop, single phase preventer, phase sequence corrector, over load protection, earth fault protection.
(ix) Drgs of LT Panel shall be approved by GE.
(x) Make of accessories such MCCB, FASD, DOL & MCB shall be of same make as per CA.
2
-
-
... More
Taking down SVL / MVL/ MH/CFL/LED llight fittings 30/48/60/70 /100/120/150 /250 /400 watts from existing pole/buildings/plant of any height/type complete all as specified and directed.
(Note:- Old U/s steel obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
38
-
-
... More
S&F Energy saving LED Flood light 30 Watt environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site.
6
-
-
... More
S&F LED Flood light fitting 100 watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting etc complete fixed bracket & suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from flood light to fittings connector all as specified and directed.
4
-
-
... More
S&F LED Flood light fitting 120 watt energy saving environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site.
4
-
-
... More
S&F LED Flood light fitting 150 watt energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site.
4
-
-
... More
S&F street light fitting 45/48 watt LED, energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement 60 watt LED street light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. (Note:- Old U/s GI pipe brackets demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
10
-
-
... More
Supply and fixing in replacement 100 watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. (Note:- Old U/s GI pipe brackets demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
4
-
-
... More
Supply and fix in replacement of MS clamp (suitable for holding street light bracket on steel pole) made out of 40 mm wide 6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps complete all as specified and directed.
10
-
-
... More
Removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge.
2800
-
-
... More
Supply and fix in replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI light bolt nuts, check nuts and washers of including providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed.
(Note:- Old U/s steel plate material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements