Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date11 Jul 2020
Closing Date8 Aug 2020
Tender Amount₹ 28,99,313 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only in replacement tripping coil assembly 24 Volts DC as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement fixed contact block complete suitable for 630/800 Amps, 11 KV HT VCB as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement LED indicator lamp suitable for operating at 110 V AC for RYB as per existing make and model complete all as specified and as directed. (Make-ABB)

6

-

-

... More
Supply only in replacement HT 11 KV PT HRC fuse AVT type 0.5 to 6 Amp and 2.5 KV to 36 KV as per existing make and model complete all as specified and as directed. (Make-ABB)

3

-

-

... More
Supply only in replacement moving contact block complete as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement vacuum interrupter type (4 inch dia) suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement maintenance free battery 2Volt, 26 AH complete all as specified and as directed. Make- Exide model No UPST 100 or equivalent model of Amaron/ Amco

14

-

-

... More
Supply only in replacement tripping push button suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement limit switch suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement charging motor button suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model complete all as specified and as directed. (Make-ABB)

2

-

-

... More
Supply only in replacement pole assembly suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model complete all as specified and as directed. (Make-ABB)

1

-

-

... More
Supply only in renewal of current transformer resin cast copper wound double tapping/dual correct 400/200/5 Amp HT 11 KV having connectors for internal wiring with 15VA burden class complete all as specified and as directed. (Make-ABB)

1

-

-

... More
M&L for servicing and renewal/replacement of defective parts of Dry type/oil type Transformer 1500 KVA 11/0.433 KV indoor type/out door type of Volt amp/CGL make by disconnecting of HT/LT bus bar connection, opening of doors etc complete cleaning of the inside compartment, core and coils by vacuum cleaner incl lead supports, tap changer terminal boards, bushings and other insulated surfaces be wiped clean lead supports, tap changer terminal boards, bushings and other insulated surfaces be wiped clean with a dry cloth and all connections must be checked for tightness after cleaning up to the satisfaction of Engr-in-Charge complete all as specified and as directed.

5

-

-

... More
Note-I (a) Transformer must be meggred and connecting all connection and necessary testing complete with including under mentioned scope of work:- (b) Cleaning of transformer from inside. (c) Testing the Transformer for IR Values (d) Checking/servicing/calibration of WTI for healthiness. (e) Magnetic Balance Test (f) IR Value check before and after the work. (g) Voltage Ratio Test at 440 V. (h) DC Logic test (j) Commissioning of transformer after completion of work.

-

-

-

... More
Note-II (i) Maintenance/repair shall be carried out by authorised dealer of OEM i,e Volt Amp Transformers Ltd. (ii) Counter guarantee certificate for servicing/maintenance of dry type transformers from OEM as mentioned above shall be submitted by the tendered before quoting his competitive rates. (iii) Test results obtained shall be recorded and produced to the Engr-in-Charge. (iv) All Measuring equipments and T&P required shall be arranged by the contractor. (v) Any item/activity not listed/covered here above and required during /completing the overhauling work will have to be arranged by Contractor himself and for this purpose no extra cost will be paid. (vi) The rate quoted shall be deemed to include for Disconnection of Transformer HV/LV terminations for testing work and re-connections after completion of repair work. (vii) Defective part measured and paid under respective item as supply only. However fixing charges shall deemed to be included in this item.

-

-

-

... More
Supply only in replacement LV bushing with studs and closing the tank top cover by fixing of suitable size of nut, bolts and washers gasket etc for the Transformer of capacity 1500 KVA complete all as specified and as directed.

1

-

-

... More
Supply only in replacement HV Bushing suitable for Transformer 1500 KVA dry type. Make- Volt Amp

1

-

-

... More
Supply only in replacement Door limit switch suitable for Transformer 1500 KVA dry type complete all as specified and as directed.

2

-

-

... More
Supply only in replacement WTI suitable for Transformer 1500 KVA dry type complete all as specified and as directed. Make- Volt Amp

1

-

-

... More
Supply only heat sensor in dry type/oil type transformer 1500 KVA Volt amp/CGL make after de energised incl making connection complete all as specified and as directed. Make- Volt Amp/ CGL

1

-

-

... More
Supply only in replacement of winding temp indicating (marshalling box) including 03 Nos PT-100 Sensors for the distribution transformer 11/0.433 KV indoor dry type of capacity 1500 KVA complete testing complete all as specified and as directed. Note for item 17.00 to 22:- All spares shall be accompanied by purchase voucher from OEM before payment. Original purchase voucher of consignor to be produced for verification to the Engineer-in- Charge before claiming his payment.

1

-

-

... More
M&L for spray painting of transformer installed at Cab Sectt preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner outside of transformer indoor type 1500 KVA to match with existing colour complete all as specified and as directed.

3

-

-

... More
All as per item No 23 here-in-before but out door oil immersed type transformers complete all as specified and as directed.

2

-

-

... More
M&L for dehydration/centrifuging of transformer oil with centrifuging machine at site and testing of transformer oil before and after de-hydration complete all as specified and as directed.

2500

-

-

... More
Supply and filling new transformer oil low viscosity type confirming to IS-335 for topping up/replacement for stabilizer required complete all as specified and as directed.

800

-

-

... More
Disconnecting HT supply and taking out defective LT ACB of any make EDO/MOD type and rating 800 to 3000 Amp and servicing by cleaning the fix and moving parts, removing dust particles by using high speed blower applying grease / jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB and replacement of all unserviceable spares as required, testing commissioning and putting on the supply on load and testing with VI injecting instrument for full load test/calibration for work efficiently in the tripping circuit complete all as specified and directed. Note:- (i) Servicing/repairs shall be carried out by OEM's authorised dealer only. (ii) Spares as required for replacement shall be of the same company as of existing make or as recommended by the OEM. (iii) Cost of spares shall be measured and paid separately under relevant items as "Supply only".

36

-

-

... More
Supply only in replacement Arc Chutes for 400/800/1000/3000A breaker suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement Jaw Contacts type MIC12D suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement CT's of suitable ratio for LT ACB of capacity 1200 to 3000 Amps as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement Upper terminals suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement lower terminals suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement circuit draw out terminals suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement pole unit suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement Motor gear box assembly suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

5

-

-

... More
Supply only in replacement Shunt trip closing coil suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

5

-

-

... More
Supply only in replacement manual charging handle suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

5

-

-

... More
Supply only in replacement UVR under voltage release coil assy CS-AUH-V-116 MA operate at 240 AC Complete suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement shutter assembly suitable for 800A/1000A /1250/3000A suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement earth fault release type EF1(10%.20% IR) suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement earth fault release type EF2(30%.40%.50%)IR) suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement Racking inter lock complete suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement fixed/moving arching contacts for 1250 A to 3000 A breaker suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement indicator lamp assembly for RYB phase suitable for 220 V/240 V as per existing make and model complete all as specified and as directed.

30

-

-

... More
Supply only in replacement Amp meter 0 to 1500 Amps suitable for LT 3 phase analog type of size 96 mm x 96 mm complete all as specified and as directed. Make- AE/ L&T/ Siemens

6

-

-

... More
Supply only in replacement selector switch for Amps/volt meter for RYB and off position as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement lockable trip push button type A suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement auxiliary contact block 2NO+2NC MNX 45 suitable for EDO/MOD 800 Amps to 3000 Amps as per existing make and model complete all as specified and as directed.

6

-

-

... More
M&L for calibration of IDMT relay non direction 2O/C + 1 E/F suitable for 440 V LT ACB with calibrating machine with respect to time and fault level and alignment of disc spring complete including replacing of auxiliary coil / contacts/bridge rectifier/Electro magnet/spacer if required complete all as specified and as directed.

15

-

-

... More
Supply, laying, jointing, testing and commissioning of XLPE (E) insulated, armoured, heavy duty PVC sheathed, HT 11 KV grade, aluminium conductor, 185 Sqmm, 3 core cable including taking out old cable etc complete all as specified and as directed.

80

-

-

... More
Supply and fixing in replacement cable termination end joint heat shrinkable in door type suitable for HT 11 KV cable XLPE (E) aluminium conductor of size 120 to 185 Sqmm x 3 core and including taking out/down cable from VCB's/Transformers after taking proper electric shut down complete all as specified and as directed.

1

-

-

... More
Supply and fixing in replacement cable termination end joint heat shrinkable in door type suitable for HT 11 KV cable XLPE (E) aluminium conductor of size 240 to 300 Sqmm x 3 core and including taking out/down cable from VCB's/Transformers after taking proper electric shut down complete all as specified and as directed.

1

-

-

... More
Supply and fixing in replacement cable termination end joint heat shrinkable out door type suitable for HT 11 KV cable XLPE (E) aluminium conductor of size 120 to 185 Sqmm x 3 core and including taking out/down cable from VCB's/Transformers after taking proper electric shut down complete all as specified and as directed.

1

-

-

... More
Taking down old U/S cable from wall/trench/roof any height and Supply, laying (laying in ducts/trenches/on walls/ fixing on existing cable tray with new saddles & clamps etc as per site requirement), jointing, testing and commissioning with new XLPE insulated, armoured, heavy duty, PVC sheathed electric cable with aluminium conductor, 1100 volts grade connecting to existing system with new cable aluminium lug and cable glands after disconnecting of old u/s PVC cable of cross sectional area 50 sqmm, 3.5 core complete all as specified and as directed.

150

-

-

... More
All as per item No 54 here-in-before but of cross sectional area 95 Sqmm 3.5 Core complete all as specified and as directed.

200

-

-

... More
All as per item No 54 here-in-before but of cross sectional area 150 Sqmm 3.5 Core complete all as specified and as directed.

150

-

-

... More
All as per item No 54 here-in-before but of cross sectional area 300 Sqmm 3.5 Core complete all as specified and as directed.

250

-

-

... More
Taking down old Broken Bricks any type from the trenches etc and M&L for burnt brick sub class ‘B’ laid in trenches abutting each other width equal to length of bricks complete all as directed.

500

-

-

... More
M&L for painting on old painted surface of HT/LT panels by brushing/cleaning stains & grease spots with thinner and sand paper and painting the cleaned surface with synthetic enamel paint (Light gray) Shade No 631 or as approved by the Engr-in-charge to achieve good finish by applying two coats of paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators relays and switches to prevent from fall of paint drops on the panels including writing, number, letter etc with white paint on newly painted surfaces complete all as specified and as directed.

45

-

-

... More
Supply & fixing in replacement and fabricating tray holding cross arms FI clamps support U clamps strips and back plates fabrication from structural steel section incl nut bolts washer bars etc of required size and thickness for supporting of cable tray by welding incl bending or welding cold or hot, drilling holes for bolt in any shape or size indicated or included of one coat primer coat under one finishing coat of black paint complete to support the cables complete all as specified and as directed.

80

-

-

... More
Servicing and overhauling by dismantling the complete unit of Automatic Voltage stabilizer100KVA installed at Machine room oil cooled type three phase 440 Volt 50 Hz including disconnecting electrical connection taking out oil from Pan. Servicing by cleaning and segregating of mechanical mechanism of operation as per direction of Engr- in–charge. Cleaning of inner surface of tank carrying out repair including replacement of worn out parts (measured and paid separately against U/M items ) replacement of nut bolt of required Nos, refilling of transformer oil after dehydration up to 60 KV for 04 mm air gap assembling and connecting to electric supply load on site testing on full load for manual automatic corrected output voltage at variable input voltage and cut off action on low voltage up to entire satisfaction complete all as specified and as directed. Note:- Spare parts shall be measured and paid for seprately as "supply only" under respective item of this schedule.

10

-

-

... More
Supply only in replacement Synchronous motor single phase, 10 Kg torque motor Make sinetrac or of the same make as already existing complete all as specified and as directed.

6

-

-

... More
Supply only in replacement High/Low Voltage cut off PCB Card as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement RC Network for motor 10 Kg torque as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement Sensing trigger transformer as per existing make and model complete all as specified and as directed.

5

-

-

... More
Supply only in replacement Micro switch as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement Carbon brush as per existing make and model complete all as specified and as directed.

30

-

-

... More
Supply only in replacement Selector switch as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement Gear/Dimmer Arm as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement Neon Indicator as per existing make and model complete all as specified and as directed.

4

-

-

... More
Supply only in replacement Rotatory switch for Voltmeter RY-YB-BR as per existing make and model complete all as specified and as directed.

6

-

-

... More
Supply only in replacement Voltmeter analogue type as per existing make and model complete all as specified and as directed.

2

-

-

... More
Supply only in replacement Ammeter with suitable CT as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply only in replacement Control Switch as per existing make and model complete all as specified and as directed.

4

-

-

... More
S&F in replacement MCCB 125 Amps, 25 KA, 3 pole, 415 Volts, 50 Hz, with thermal magnetic settings electrical connections with suitable size aluminium lugs, including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. Note:- (i) Cost of copper/aluminium thimbles (as required at site or as directed by the concerned JE E/M) or any modification work required for fixing of MCCB (drilling holes/welding work etc) will deemed to be included in quoted rates. (ii) MCCBs shall be thermal magnetic type DPX3 and of the same make of existing.

2

-

-

... More
All as per item No 75 here in before but 160 Amps, 36 KA, 3 pole complete all as specified and as directed.

1

-

-

... More
All as per item No 75 here in before but 250 Amps, 36 KA, 3 pole complete all as specified and as directed.

1

-

-

... More
All as per item No 75 here in before but 250 Amps, 36 KA, 4 pole complete all as specified and as directed.

1

-

-

... More
All as per item No 75 here in before but 630 Amps, 50 KA, 4 Pole complete all as specified and as directed.

1

-

-

... More
All as per item No 75 here in before but 800 Amps, 36 KA, 4 Pole complete all as specified and as directed.

2

-

-

... More
S&F in replacement factory made, sheet steel metal enclosure for MCCB frame size DPX 630 incl all fixing material/accessories such as mounting nuts etc complete all as specified and as directed. Make:- Legrand/Havells/L&T.

1

-

-

... More
S&F in replacement factory made, sheet steel metal enclosure for MCCB frame size DPX 800 incl all fixing material/accessories such as mounting nuts etc complete all as specified and as directed. Make :- Legrand/Havells/L&T.

1

-

-

... More
S&F in replacement Automatic control unit (for automatic transfer switch) communication unit enabling data transmission complete all as specified and as directed. Make- Legrand Cat part No- 0261 94 or equivalent model of L&T/ Seimens

2

-

-

... More
Supply and laying in replacement GI pipe 80 mm bore, medium grade (for cable protection) ISI marked complete all as specified and as directed.

20

-

-

... More
Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connections one twin core cable flat of size 4.0 sqmm, aluminium stranded conductors complete all as specified and as directed.

50

-

-

... More
All as per item No 84 here-in-before but of size 6.0 sqmm complete all as specified and as directed.

50

-

-

... More
Disconnecting electrically switch boards/ electric panels/ distribution boards of any size in switch rooms by taking proper electric shut down, opening cables from MCCBs/DBs/main switches/panels, cutting of unserviceable/overheated cable ends/ thimbles etc, M&L for fixing of new aluminium thimbles of any size up to 630 sqmm as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing complete all as specified and as directed.

36

-

-

... More
Excavation in trenches not exc. 1.5 m wide and not exec 1.5 mtr deep for foundation etc or for shafts, wells, cesspits, mainholes, pierholes etc in any type of soil for foundation and getting out and levelling of bottom surface to required level complete all as specified and as directed.

10

-

-

... More
Returning filling including levelling, watering and well ramming soil in layers not exceeding complete all as specified and as directed.

7

-

-

... More
Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level complete all as specified and as directed.

1

-

-

... More
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and as directed.

2

-

-

... More
Cutting of existing road/PCC/RCC/Hard standing for laying of pipe including making good the disturbed surface to match with the adjoining surfaces with PCC 1:3:6 C2 complete all as specified and as directed.

2

-

-

... More
Attending breakdown /inspection of dry type 1500KVA transformer by OEM service engineer to check and replace any spars related breakdown complete all as specified and as directed.

2

-

-

... More
Attending breakdown /inspection of oil type 1500KVA transformer by OEM service engineer to check and replace any spars related breakdown complete all as specified and as directed.

3

-

-

... More
Attending breakdown /inspection of EDO/MOD type 1250 to 3000 Amps ACB by OEM service engineer to check and replace any spars related breakdown complete all as specified and as directed.

15

-

-

... More
Attending breakdown /inspection of EDO type HT 11KV/12KV VCB by OEM service engineer to check and replace any spars related breakdown complete all as specified and as directed. Note for 93 to 96:- (a) Spars shall be paid separately under relative items. (b) A sum of Rs 4000.00/day shall be recovered in case of not attend break down by service Engineer and not rectified defect with in 24 Hrs.

5

-

-

... More
Supply only in replacement rubber mat size 1 Mtr x2 Mtr x 19 mm thick suitable for 11 KV complete all as specified and as directed.

15

-

-

... More
Supply only in replacement electric rubber hand gloves suitable for 33 KVcomplete all as specified and as directed.

6

-

-

... More
Supply only in replacement electric rubber shoes suitable for 33 KV complete all as specified and as directed.

6

-

-

... More
S&F in replacement lead -Acid battery type EP42-12, 12V, capacity 42 Ah Make- Exide Power Safe or equivalent model of Amaron/ STANDARD FURKKAVA

16

-

-

... More
S&F in replacement lead- Acid battery type EP 120 -12, 12V, capacity 120 Ah Make- Exide Power Safe or equivalent model of Amaron/ STANDARD FURKKAVA

10

-

-

... More
Supply only in replacement heavy duty electric Air blower heavy duty 620W to 700W, for cleaning of dust partical inside VCB/ACB complete all as specified and as directed. Make- CHESTON/ BOSCH/ STANELY

2

-

-

... More
Note for item No 1.00 to 102.00:- (i) It is not mandatory to hand over the work site/ bldg to the Cotractor in one stretch. (ii) It may be handed over in peace-meal as and when the site/ bldg are vacated by the user including Sunday/ Holiday/ Night Hrs. Contractor shall make/ changes the execution plan accordingly. Any claim what so ever on this account shall not be admissible. (iii) Rate quoted by the Contractor shall be deemed to include on this account.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.