Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 58,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
500 to 1000 KVA

6

-

-

... More
Dehydration and filtration of the existing transformer/servo voltage stablizer oil by dehydration plant in running condition to achieve di-electric strength of 40 KV at the gap of 2.5 mm complete all as specified and directed by Engineer-in-charge.(Dehydration plant shall be provided/brought at site by the contractor) and shall also include the following provisions :- (a) Testing of transformer /servo voltage stablizer oil before & after dehydration shall be carried out as directed. (b) Contractor will maintain a register of dehydration and filtration of each and every equipment as per format given by Engr-in-charge and submit the same to Engr-in-charge.

19500

-

-

... More
Supply and filling transformer oil for topping up of min BDV 50 KV or replacement in different existing transformers outdoor/indoors type of any capacity located and installed at different places and different height complete all as specified and as directed by the Engineer-In-Charge. Note: - The entire quantity of transformer oil shall be procured in sealed container.

1420

-

-

... More
Supply and replacement of dehydrating agents (Silica gel) in transformers of capacity upto 1000 KVA, outdoor/indoor type complete all as specified and directed by the Engineer-In-Charge.

12

-

-

... More
Disconnecting of HT/LT connection including earthing strips from 11/0.433 KV indoor/outdoor transformer of following capacity after taking shut down from Engr-in-charge and follow all safety precaution and taking down ( if mounted on four pole structure ) or taking out ( installed in indoor substation ) at different locations in the area of CAMERO or WAC under GE (AF) Subroto Park with help of suitable crane and transporting to approved workshop and back after repair/ rewinding and installing at original location and reconnecting HT/LT connection including earthing and testing, commissioning complete all as specified and directed. Note- (i) Rewinding of HT/LT coil any type/ material, dehydration of transformer oil, re-assembling after repair etc.will be measured and paid separately under relevant item of the schedule. (ii) Spare part shall be measured and paid separately as supply only and cost of fixing and connection of spare shall be deemed to be included in the quoted rate of the above items.

-

-

-

... More
Transformer upto 400 KVA capacity

4

-

-

... More
Transformer 500 to 1000 KVA capacity

2

-

-

... More
M&L for dismantling of transformer 11/0.433 KV at approved workshop and taking out defective core and replacement of HT/LT copper winding with super enamelled copper wire of original size and including necessary cotton insulating tape, separator,nut, bolts of suitable size and dehydration of transformer oil and topping up of deficient transformer oil and replacement of defective parts like bushing, tap changers, gaskets etc.(copper wire, transformer oil and other accessories will be measured and paid separately in respective items) but cost of separator, insulating cotton tape and nut, bolt are included in item rate.

-

-

-

... More
Transformer upto 400 KVA capacity

3

-

-

... More
Transformer 500 to 1000 KVA capacity

2

-

-

... More
M&L for re-winding of burnt defective HT/LT copper coil of different capacity transformer with superior quality enamelled copper winding wire/ strips of approved of suitable size/ gauge and No.s of turns matching with the existing impedance and insulated including all allied materials such as cork sheets, fibre glass insulation/paper insulation cotton, empire tape and wooden, bolts, nuts and washer (Brass) soldering and other packing material etc required for entire winding of coils all as specified and directed by Engineer- in-Charge.

910

-

-

... More
Supply and replacement of LT bushing (Brass stud and bolts with porcelain insulator) suitable size to fixed the transformer capacity range 63 to 400 KVA including replacement of gasket , cable glands, etc. to make the transformer leak proof complete all as specified and directed by Engr-in-charge

16

-

-

... More
All as per item ser No 9 above but suitable for 500 KVA to 1000 KVA transformer complete all as specified and directed

8

-

-

... More
Supply and fix in replacement ceramic bushing and Gasket on LT side of transformer of following capacities :-

-

-

-

... More
63 KVA to 400 KVA

7

-

-

... More
500 to 1000 KVA

6

-

-

... More
All as per item No 11 above, but on HT side of transformer of following capacites :-

-

-

-

... More
63 KVA to 400 KVA

4

-

-

... More
500 to 1000 KVA

5

-

-

... More
M&L for replacement of worn out off load tap changer set and connecting with existing winding to match the ratio of tap position all as per existing sample suitable for transformers of capacity 63 to 500 KVA all as specified and directed by Engineer-in-Charge.

9

-

-

... More
M&L in replacement for oil temperature gauge suitable for any size of transformers all as per existing shape and size for any make and model transformers all as specified and directed including taking out old gauge all as specified and directed by Engineer-in-Charge.

9

-

-

... More
Supply & fixing in repair mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E-250) quality-A complete all as specified and directed by Engr-in-charge

400

-

-

... More
M&L preparation of old painted steel surfaces or wire mesh fencing around the outdoor transformer over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engr-in-charge

325

-

-

... More
M&L for maintenance to existing HT /LT panels, indoor/outdoor type installed at various location, installation using suitable welding machine for LT panel, replacement of door hinges, nuts & bolts, door beaders/ gaskets, panel locks including with one coat of super enameled paint of approved colour on exposed surface including preparation of surfaces all as specified and directed by Engineer-in-charge

20

-

-

... More
M&L for HT cable XLPE insulated screened, galvanized steel wire armored, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of following sizes :-

-

-

-

... More
300 sqmm 3 core

100

-

-

... More
185 sqmm 3 core

120

-

-

... More
120 sqmm 3 core

250

-

-

... More
95 sqmm 3 core

270

-

-

... More
Supply and Laying of LT cable XLPE insulated screened, galavanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following size :-

-

-

-

... More
400sqmm 3.5 core.

120

-

-

... More
300 sqmm 3.5 core.

70

-

-

... More
240sqmm 3.5 core.

150

-

-

... More
185 sqmm 3.5 core.

260

-

-

... More
120 sqmm 3.5 core.

190

-

-

... More
Supply and fixing in replacement cable jointing kit and testing complete for 11 KV grade cable for Indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm to 185 sqmm all as specified and directed.

8

-

-

... More
All as per item No 20 above but of size 240 sqmm to 300 sqmm complete all as specified and directed.

7

-

-

... More
All as per item No 20 above but of size 50 sqmm to 95 sqmm complete all as specified and directed.

7

-

-

... More
Supply and jointing in replacement heat shrinkable straight through joint with jointing material suitable for HT 11KV XLPE cable of size 120 to 185 Sq mm 3 core complete all as specified and as directed by Engineer-in-Charge.

6

-

-

... More
Supply and jointing in replacement heat shrinkable straight through joint with jointing material suitable for HT 11 KV XLPE cable of size 240-300 sqmm 3 core complete all as specified and as directed by Engineer-in-Charge.

6

-

-

... More
Supply and jointing in replacement cold shrinkable straight through joint with jointing material suitable for HT 11 KV XLPE cable of size 50 to 95 sqmm 3 core complete all as specified and as directed by Engineer-in-Charge.

6

-

-

... More
S & F in replacement heat shrinkable straight through Jointing Kit suitable for LT Cable of size 185 sq mm to 400 sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.

8

-

-

... More
Disconnecting the ends of the HT/LT underground/duct cable and taking out the unserviceable cable of any size all as specified and as directed by the Engineer-In-Charge.

1530

-

-

... More
Excavation in trenches in soft/ loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and directed. Note :- Mechanical excavation is not allowed in this Stn only manual excavation allowed.

460.89

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.

292.67

-

-

... More
Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.

168.22

-

-

... More
Material and labour for sand cushioning by using fine sand (Jamuna dry and clean sand ) in two layers, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable complete all as specified and directed. Note : For payment purpose punned thickness of sand shall be measured.

111.7

-

-

... More
M&L in replacement for brick, subclass 'B' well burnt, of size 230x115x75 mm laid dry flat in trenches for protection of cable over LT cable, complete all as specified and directed by the Engineer-In-Charge

6.28

-

-

... More
Supply and laying in replacement un-reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete all as specified and directed.

3645

-

-

... More
Supply & Laying in replacement GI pipe light grade 80mm bore for cable protection with all fittings for passing the underground HT cable under road crossing along poles walls and floors complete all as specified and directed.

32

-

-

... More
Supply & Laying in replacement GI pipe light grade 100mm bore for cable protection with all fittings for passing the underground HT cable under road crossing along poles walls and floors complete all as specified and directed.

32

-

-

... More
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
S&F in replacement of MCCB 400 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
Supply only suitable for 11KV HV Hand gloves complete with ISI marked complete all as specified and as directed.

8

-

-

... More
M&L for cutting of Hardstanding/ road by manual method upto 200mm deep for inserting GI pipe for cable protection complete and making good disturbed surfaces with ready mix concrete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Cutting removing the vegetation growth and surface dressing all around the installation yard including two pole structure areas, around power house, substation (external only) to keep always installation clean and tidy complete all as specified and as directed.

300

-

-

... More
S&F in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S.clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.

10

-

-

... More
Supply and fix in replacement of route indicator of HT and LT cable with capacity and location of plate size 20cmx20cmx3mm made of GI plate with angle iron 20mmx20mm and 60cm long complete all as specified and as directed. Note PCC work shall be measured and paid separately.

30

-

-

... More
M & L in replacement for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 25x4mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with MS bar 8mm C/C 100mm MS handle made of 10mm MS bar and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia light grade pipe and watering pipe shall be 20mm bore light grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.

19

-

-

... More
M & L for excavation by trenchless boring technology for holes under road pavement, hardstanding using ultra sound technique and engaging necessary machine including HDPE pipe ISI marked of dia 100 mm suitable for 0.4 Mpa working pressure complete all as specified and directed by Eng-in-charge. Note: HDPE pipe and marking good the disturbed surface is deemed to be included in rate quoted by the contractor).

25

-

-

... More
M&L cement concrete type B-1, 1:2:4 using 20mm grade aggregate in mass concrete complete all as specified and directed.

5

-

-

... More
Disconnecting worn out HT cable connections any size from HT RMUs/ VCBs/ compact sub station cutting worn out leads (near lugs ), re-fixing new aluminium lugs, cleaning the insulator and post of cable connector with 2-26 CRC solution , insulating with HT tape , connecting the cables with post top and testing for smooth functioning complete all as specified and directed.

42

-

-

... More
Repair/ servicing of 400 to 1250 A , 11 KV mechanism/ calibration of HT VCB with highly skilled mechanic specialist in electric HT breakers line, by taking out trolley, decarbonizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/ OFF operation with setting of buffer gap adjustment, inspecting the wiring of IDMT relays contact travel contact alignments, roller gap, hard or light setting of breaker greasing of all moving mechanism complete all as specified and directed. Note ; Calibration will be carried out by authorised contractor/ Technician and test certificate will be kept on record.

35

-

-

... More
Repair/ servicing of 400/ 630 A . 11 KV mechanism/ calibration of HT RMU with highly skilled mechanic specialist in electric HT breakers line,by taking out breaker mechanism, decarborizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections and ON/OFF operation with setting of buffer gap adjustment complete all as specified and directed.

5

-

-

... More
Repair/ servicing of compact sub-station including dry type transformer of various capacity with air blower and necessary insulation and 11 KV breaker with highly skilled mechanic specialist in electric HT breakers line, decarborizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/ smooth contact, tightening of all connections, checking of all electric connection and ON/OFF operation with setting of buffer gap adjustment, complete all as specified and directed.

2

-

-

... More
Supply and refilling of SF6 gas in existing RMUs by the trained technician at various locations of GE (AF) Subroto Park including opening of valve connected in RMU upper chamber and testing pressure after refilling the gas SF6 complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
S & F in replacement of Gum boot of RMU of various capacity fixed in existing RMU complete all as specified and directed

8

-

-

... More
S & F in replacement of spring charging geared motor 230V AC/DC complete all as specified and directed

9

-

-

... More
S & F in replacement of epoxy resin spouts bushing for VCB complete all as specified and directed

11

-

-

... More
S & F in replacement of trip coil/ close coil for VCB complete all as specified and as directed

14

-

-

... More
S & F in replacement of male female finger Contact( Jaw cluster) upto 1250A as per existing VCB complete all as specified and directed

15

-

-

... More
S & F in replacement of heater as per existing type in VCB complete all as specified and directed

10

-

-

... More
S & F in replacement Indicator lamp with and including holder & cover to show all the three phase i.e RYB to be mounted on 11 KV HT switch gear complete all as specified and directed.

24

-

-

... More
S & F in replacement of Push button for trip and hold of 11 KV 400 A RMU/ VCB complete all as specified and as directed.

19

-

-

... More
S & F in replacement Bakelite kitkat with 10 A HRC fuse type NS complete all as specified and directed.

21

-

-

... More
Supply & Fixing in replacement of digital voltmeter, flush mounted, class - 1.0, size 96 X 96 Sq mm complete all as specified and directed.

8

-

-

... More
S&F in replacement of digital Ammeter, flush mounted, class - 1.0, size 96 X 96 Sq mm complete all as specified and directed.

9

-

-

... More
Taking down IDMT relay, testing/ calibration of IDMT relay (Set of two) over current and one earth fault for healthy tripping of over current and earth fault, adjust tripping time flag setting, ratio setting, instantaneous time setting etc. as per installed capacity of transformer to be saved on maximum Short circuit current with considering of percentage impedance of transformers with artificial current injunction on primary side with current injunction machine and setting of relays to make as per the CT ratio complete all as specified and directed.

33

-

-

... More
S & F in replacement digital type single pole non directional relay for one earth fault & two over current, type CDG-31,3D Horz 2 No S/R 3 element O/C & EF comprising over current operator with DC current connecting setting as per ratio including complete wiring complete all as specified and directed.

8

-

-

... More
S & F in replacement of dry type air cooled potential transformer of 11 KV single phase indoor resin cast CT of ratio 11 KV /v3/110V/v3/110V/v3 class 0.5-3, Bus bar 50 VA-50 VA, insulation level 28/75 KV voltage factor 1.2 Cont and 1.9 for 30 Sec conforming to IS-3156 complete all as specified and directed.

3

-

-

... More
S & F in replacement Primary copper wound type HT resin cast CTs, air cooled , dual current 15 VA burden of ratio 100/50/05 A., class 5P1O accuracy S T C 18.4 KA for 3 section protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete all as specified and directed.

3

-

-

... More
All as per srl item No 65 here-in-before but burden of ratio 200/100/5 A complete all as specified and directed.

3

-

-

... More
All as per srl item No 65 here-in-before but burden of ratio 400/200/5 A complete all as specified and directed.

3

-

-

... More
M&L in replacement of maintenance free battery 12 Volt, 120AH including replacement of battery lead clips complete all as specified and directed.

2

-

-

... More
Supply, laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 Kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.

8

-

-

... More
Towing trolly of transformer/ DG set to nearest workshop with towing vehicle or crane , dismantling the following burnout parts and re-fixing to its original position after replacement with new:- (a) Bearing, (b) tubes or tube less tyre of existing size (c) suspension assy minor part if required including 4 wheel hub greasing . Scraping the existing paint, preparing surfaces by rubbing properly with zero number sand paper and then painting two coat of synthetic enamel paint with spray gun over a coat of red oxide primer including welding work if required complete all as specified and as directed by engineer in charge.

1

-

-

... More
S & F in replacement of power pack unit input 110 / 230 Volt AC and out put 24/110 V DC for maintenance free batteries charging for smooth tripping complete all as specified and as directed.

1

-

-

... More
S&F in repair automatic street light controller/ timer switches 415 V three Phase with infrared sensor based nature switch and voltage monitoring system (VMS) three phase load of 5KW rating with contactor fitted inside steel enclosure for automation of street light complete all as specified and directed.

2

-

-

... More
Supply and fixing in repair LED post top lantern made in die-cast aluminium bottom housing and spin aluminium top reflector with decorative clear acrylic and IP65 protection. opeal diffuser of 45W LED type complete all as specified and directed.

8

-

-

... More
Supply & fixing in repair of Chain Link Fencing 50x50mm mesh size for covered the 11 KV substation of 12m length and 2.1m high Chain link fencing, 50x50mm of mesh size made with 4mm dia GI wire including 04 Nos of 10mm dia tie round bars, securing with 12mm dia 100mm long botls @ 04 Nos at each post along with 50x6mm FI with 5 Nos of 65x65x6mm angle iron post embedded in PCC 1:3:6 of foundation size of 1.2x0.50x0.60m including excavation in post holes and removal of surplus soil to a distance 50m away from the site and provision of MS steel gate of size 2.0 x 2.0m, bottom portion covered with 1.60mm thick MS black sheet and painting work for fencing and gate with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
S&F in replacement of MCCB 500 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of breaking capacity 36 KA complete all as specified and directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.