Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date6 Dec 2019
Closing Date26 Dec 2019
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair maintenance to HT LT cable MCCB ACB GO DO jumpher pole box pole painting panel painting earthing and connected items at Cariappa vihar EME workshop 105 TA BD Coy RR colony 5 RMC Uri enclave 1 WEC DAS EETSU Polo ground Todapur Kan
Repair maintenance to HT LT cable MCCB ACB GO DO jumpher pole box pole painting panel painting earthing and connected items at Cariappa vihar EME workshop 105 TA BD Coy RR colony 5 RMC Uri enclave 1 WEC DAS EETSU Polo ground Todapur Kan
Repair maintenance to HT LT cable MCCB ACB GO DO jumpher pole box pole painting panel painting earthing and connected items at Cariappa vihar EME workshop 105 TA BD Coy RR colony 5 RMC Uri enclave 1 WEC DAS EETSU Polo ground Todapur Kan
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of ACSR conductor from LT overhead lines complete all as directed by Engr-in-charge

1.5

-

-

... More
M & L taking down of existing street light from item No 1 above and fixing on new poles complete all as directed by Engr-in-charge

15

-

-

... More
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.

756

-

-

... More
Returning filling Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.

482

-

-

... More
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.

274

-

-

... More
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.

226

-

-

... More
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.

20000

-

-

... More
All as per srl item No 10 here-in-before but using old bricks obtained under srl item No 6 here in before.

3000

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.

500

-

-

... More
All as per srl item No 12 here-in-before but using old cable cove obtained under srl item No 6 here in before.

300

-

-

... More
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for HT 1100 V system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.

-

-

-

... More
16 Sqmm 4 core

1000

-

-

... More
25 Sqmm 4 core

500

-

-

... More
35 Sq mm 3.5 core.

200

-

-

... More
50 Sq mm 3.5 core.

500

-

-

... More
70 Sqmm 3.5 core

120

-

-

... More
95 Sqmm 3.5 core

400

-

-

... More
120 Sqmm 3.5 core

400

-

-

... More
185 Sqmm 3.5 core

400

-

-

... More
240 Sqmm 3.5 core

80

-

-

... More
400 Sqmm single core

160

-

-

... More
630 sqmm single core

160

-

-

... More
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes

-

-

-

... More
95 sqmm 3 core.

60

-

-

... More
120 sqmm 3 core.

100

-

-

... More
185 sqmm 3 core

20

-

-

... More
240 sqmm 3 core

20

-

-

... More
300 sqmm 3 core

80

-

-

... More
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed

40

-

-

... More
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes

-

-

-

... More
100mm

10

-

-

... More
80 mm .

12

-

-

... More
50 mm .

20

-

-

... More
40 mm .

24

-

-

... More
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-

-

-

-

... More
25-50 Sqmm x 3.5 core/ 4 core

5

-

-

... More
70-150 Sqmm x 3.5 core

5

-

-

... More
185 -240 Sqmm x 3.5 core

4

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-

-

-

-

... More
95 Sqmm 3 core.

4

-

-

... More
120 Sqmm to 185 Sqmm, 3 core.

5

-

-

... More
240 Sqmm to 300 Sqmm 3 core

3

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-

-

-

-

... More
95 Sqmm 3 core.

6

-

-

... More
120 Sqmm to 185 Sqmm, 3 core.

5

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-

-

-

-

... More
95 Sqmm 3 core.

2

-

-

... More
120 Sqmm to 185 Sqmm, 3 core.

6

-

-

... More
240 Sqmm to 300 Sqmm 3 core

6

-

-

... More
S&F in replacement of UNSV MCCBs of capacity 630 Amps, TP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed

2

-

-

... More
Description all as per ser item No 22 above, but rating of MCCB 400 Amp, 36 KA

2

-

-

... More
Description all as per ser item No 22 above, but rating of MCCB 250 Amp, 36 KA

4

-

-

... More
Description all as per ser item No 22 above, but rating of MCCB 200 Amp, 25 KA

5

-

-

... More
Description all as per ser item No 22 above, but rating of MCCB 160 Amp, 25 KA

5

-

-

... More
Description all as per ser item No 22 above, but rating of MCCB 125 Amp, 25 KA

10

-

-

... More
Description all as per ser item No 22 above but rating of MCCB 100 Amp,25KA

6

-

-

... More
Description all as per ser item No 22 above but rating of MCCB 63 Amp, 25 KA

10

-

-

... More
S&F in replacement of UNSV MCCBs of capacity 630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed

1

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 400 Amp, 36 KA

2

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 320 Amp, 36 KA

1

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 250 Amp, 36 KA

4

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 200 Amp, 25 KA

4

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 160 Amp, 25 KA

3

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 125 Amp, 25 KA

6

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 100 Amp, 25 KA

6

-

-

... More
Description all as per ser item No 30 above but rating of MCCB 63 Amp, 25 KA

6

-

-

... More
S&F in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable changeover from panels etc complete all as directed

2

-

-

... More
All as per item No 39 above but 250 Amps 4 pole

1

-

-

... More
All as per item No 39 above but 200 Amps 4 pole

1

-

-

... More
S&F on load change over switch with SS enclosure of capacity 125 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU complete all as directed.

2

-

-

... More
Supply and fixing in renewal of 3 pole power contactor ML-6 Cat No SS90921 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as directed.

2

-

-

... More
Supply and fixing in renewal of 3 pole power contactor MNX-110 Cat No CS94137 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as directed.

4

-

-

... More
Supply and fixing in renewal of Analog Time switch Cat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as directed.

7

-

-

... More
Supply and fixing in replacement LT current transformer having ratio 400/5 Amp , 15 VA, Class 0.5. Complete all as specified and directed by Engr-in-Charge

9

-

-

... More
All as per Srl item No.46 herein before but CT ratio 250/5 Amp

9

-

-

... More
All as per Srl item No.46 herein before but CT ratio 200/5 Amp

9

-

-

... More
Supply and fix MCCB 100 Amp, 4 pole , 25 KA, 50 Hz with MCCB sheet metal enclosure mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU complete all as directed .

4

-

-

... More
S&F in replacement of item No 1 Steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of aluminium red oxide complete all as specified and directed.

15

-

-

... More
Earthing complete in replacement with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.25 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.

15

-

-

... More
Supply & Fixing in replacement bracket for street light fitting complete with 2.2 mtr long 40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed.

10

-

-

... More
S&F in replacement ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type , front operated with Micro processor based protection release for adjustable over current, short circuit and earth fault protection

2

-

-

... More
S&F in replacement of UNSV MCCBs of capacity 250 Amps, TP, 35 KA, 415 Volts 50 Hz, AC, with microprocessor release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed

2

-

-

... More
Description all as per ser item No 54 above, but rating of MCCB 200 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 54 above, but rating of MCCB 160 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 54 above, but rating of MCCB 125 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 54 above, but rating of MCCB 100 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 54 above, but rating of MCCB 63 Amp, 35 KA

2

-

-

... More
S&F in replacement of UNSV MCCBs of capacity 400 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with microprocessor release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed

2

-

-

... More
Description all as per ser item No 60 above but rating of MCCB 250 Amp, 35 KA

3

-

-

... More
Description all as per ser item No 60, above but rating of MCCB 200 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 60, above but rating of MCCB 125 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 60, above but rating of MCCB 100 Amp, 35 KA

2

-

-

... More
Description all as per ser item No 60, above but rating of MCCB 40 Amp, 35 KA

2

-

-

... More
Material and labour disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.

35

-

-

... More
Supply and fixing in replacement of cable gland for LT panel/feeder pilar up to 50 Sqmm cable complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 70 sqmm cable to 240 Sqmm cable complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified and directed.

6

-

-

... More
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed.

10

-

-

... More
Material and labour in replacement of Ammeter 0-400/800 Amp digital type per existing size complete all as per specified and directed

10

-

-

... More
Supply and fixing in replacement of 3 way rotary selector switch

1

-

-

... More
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed.

20

-

-

... More
Supplying and fixing in replacement kit kat rewireable porcelain fuse carrier & base 63 Amps , 415 Volt complete all as directed .

20

-

-

... More
Supplying and fixing in replacement kit kat rewireable porcelain fuse carrier & base 100 Amps , 415 Volt complete all as directed .

15

-

-

... More
Supplying and fixing in replacement MCB 4 pole , 63 Amps, 10 KA ,50 Hz,415 Volts

2

-

-

... More
Supplying and fixing in replacement MCB 4 pole , 32 Amps,10 KA,50 Hz,415 Volts

2

-

-

... More
Supplying and fixing in replacement MCB DP , 63 Amps,50 Hz,10 KA,240 Volts

3

-

-

... More
Supplying and fixing in replacement MCB DP , 6 to 32 Amps,50 Hz,10 KA,240 Volts

3

-

-

... More
Supplying and fixing in replacement MCB SP , 6 to 32 Amps,50 Hz,10 KA,240 Volts

2

-

-

... More
Supplying and fixing in replacement Mild steel sliding door bolts 200 mm long ,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate

5

-

-

... More
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 15 Amps fuse grip with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.

200

-

-

... More
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.

25

-

-

... More
All as per item No 83 above but of approx size upto 1.90 Sqm

30

-

-

... More
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.

300

-

-

... More
Supply and fix in replacement air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulator and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements worked from ground level for current rating 400 Amps, HT 11 KV grade including drop out fuses and necessary silver coper coating jumpers and making all electrical connections complete.

5

-

-

... More
Earthing complete in replacement with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized Iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.