Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date16 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 48,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Notes for Item No 1.01 & 1.02 :- (i) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate No of helpers as directed by Engineer-in-charge. (ii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 200/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iii) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (iv) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' BOQ. However , no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch as supply only vide item No 2 to 9, 10.01 to 10.10, 12.01 to 12.04, 13, 14, 15, 44 to 51.02). (vi) All T&P required for attending the Complaints shall be provided by the contractor. (vii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site.

-

-

-

... More
(viii) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (ix) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. (x) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record. (xi) Old U/s material iron scarp obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Supply only GI socket Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

80

-

-

... More
20mm bore

80

-

-

... More
25mm bore

60

-

-

... More
40mm bore

20

-

-

... More
50mm bore

15

-

-

... More
Supply only GI Elbow Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

80

-

-

... More
20mm bore

80

-

-

... More
25mm bore

60

-

-

... More
40mm bore

20

-

-

... More
50mm bore

10

-

-

... More
Supply only GI Union Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

80

-

-

... More
20mm bore

80

-

-

... More
25mm bore

60

-

-

... More
40mm bore

20

-

-

... More
50mm bore

10

-

-

... More
Supply only GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-

-

-

-

... More
15 mm bore

60

-

-

... More
20mm bore

60

-

-

... More
25mm bore

60

-

-

... More
40mm bore

20

-

-

... More
50mm bore

10

-

-

... More
Supply only PVC 'L' type Holder, Aluminium rod, Float Ball etc complete all as required at site and all as directed of following Size:-

-

-

-

... More
15 mm bore

20

-

-

... More
20mm bore

20

-

-

... More
25mm bore

15

-

-

... More
40mm bore

10

-

-

... More
50mm bore

5

-

-

... More
Supply only GI Reducing socket Med grade ISI marked of following sizes :

-

-

-

... More
20mm x 15 mm bore

10

-

-

... More
25mm x 15mm bore

15

-

-

... More
25mm x 20mm bore

15

-

-

... More
50mm x 40 mm bore

10

-

-

... More
Supply only GI solid plug heavy duty ISI marked of following sizes :

-

-

-

... More
15 mm bore

8

-

-

... More
20mm bore

8

-

-

... More
25mm bore

8

-

-

... More
40mm bore

4

-

-

... More
50mm bore

4

-

-

... More
Supply only GI Tee of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-

-

-

-

... More
15mm x 15mm x15 mm bore

60

-

-

... More
20mm x 20mm x 20 mm bore

60

-

-

... More
25mm x 25mm x 25 mm bore

60

-

-

... More
40mm x 40mm x 40mm bore

20

-

-

... More
50mm x 50mm x 50 mm bore

10

-

-

... More
Supply only GI reducing TEE of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-

-

-

-

... More
20mm x 20mm x15 mm bore

60

-

-

... More
25mm x 25mm x 15 mm bore

60

-

-

... More
25mm x 25mm x 20 mm bore

60

-

-

... More
40mm x 40mm x 15mm bore

20

-

-

... More
40mm x 40mm x 20mm bore

20

-

-

... More
40mm x 40mm x 25mm bore

10

-

-

... More
50mm x 50mm x 15mm bore

10

-

-

... More
50mm x 50mm x 20mm bore

10

-

-

... More
50mm x 50mm x 25mm bore

10

-

-

... More
50mm x 50mm x 40mm bore

8

-

-

... More
Supply, fixing & Laying of tubing GI pipe 'medium grade' ISI mark including all fittings in old/new positions in trenches/wall/floor complet and making good the distributed surfaces as per existing including taking down of existing GI Pipe any type/rusted etc complete all as specified and directed of following sizes. (Note:- (i) Excavation and earth work will be measured and paid separately. (ii) Old U/s material GI tubing obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
15 mm bore

180

-

-

... More
20 mm bore

320

-

-

... More
25 mm bore

200

-

-

... More
40 mm bore

150

-

-

... More
50 mm bore

100

-

-

... More
Supply only of following items in closed containers:-

-

-

-

... More
Supply only of Lead Pig bar

200

-

-

... More
Supply only of Spun yarn

30

-

-

... More
Supply only of Lead wool

20

-

-

... More
Supply only Nuts, Bolts and Washers of size 25 to 150 mm long of 6 to 20 mm dia complete all as specified and directed.

100

-

-

... More
Supply only PTMT Float valve with epoxy coated aluminium rod and high density HDPE ball (As per manufacturers instructions) of following sizes complete of following sizes :

-

-

-

... More
15 mm bore

80

-

-

... More
20 mm bore

250

-

-

... More
25 mm bore

100

-

-

... More
40 mm bore

40

-

-

... More
50 mm bore

20

-

-

... More
Supply only Gun metal gate valve with iron wheel head screwed both ends for iron pipe as per IS-778 complete 'ISI marked' of following sizes :-

-

-

-

... More
15 mm bore

30

-

-

... More
20 mm bore

50

-

-

... More
25 mm bore

40

-

-

... More
40 mm bore

20

-

-

... More
50mm bore

15

-

-

... More
Supply only Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms). complete all as specified and as directed.

-

-

-

... More
15 mm bore

15

-

-

... More
20 mm bore

15

-

-

... More
(Note for ser item No 2 to 15 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV old u/s scrap material in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Opening the existing Sluice Valve including opening of gland cover taking out with stem nut of brass or of stainless steel & refixing the same after repair with & including replacement of rubber packing, nut & bolts, glands dori, etc complete all as specified and directed of following sizes:- (Note :- Spare parts under relevant items shall be measured and paid separately under repsiective items)

-

-

-

... More
80 mm bore

5

-

-

... More
100 mm bore

6

-

-

... More
150 mm bore

4

-

-

... More
250 mm bore

5

-

-

... More
Supply only 'stem' made out from stainless steel of sluice valve of following sizes, complete all as specified :-

-

-

-

... More
80 mm bore

5

-

-

... More
100 mm bore

10

-

-

... More
150 mm bore

15

-

-

... More
250 mm bore

5

-

-

... More
Supply only 'Stem Nut' made out from stainless steel suitable to match with existing sluice valve of following sizes complete all as specified :-

-

-

-

... More
80 mm bore

5

-

-

... More
100 mm bore

10

-

-

... More
150 mm bore

15

-

-

... More
250 mm bore

10

-

-

... More
Supply only 'Gland Plate' made out from Cast Iron of suitable match with existing sluice valve of following sizes complete all as specified :-

-

-

-

... More
80 mm bore

5

-

-

... More
100 mm bore

10

-

-

... More
150 mm bore

15

-

-

... More
250 mm bore

5

-

-

... More
(Note for ser item No 17 to 19 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Taking up or down CI/DI/MS Pipe of following sizes including all fittings with spigot and socketed ends and lead tyton joints including burning out of lead joints and recovering lead and including cleaning for refixing or removal complete all as specified and as directed. (Note:- (i) Excavation & earth work shall be measured & paid separetely. (ii) Old lead shall be taken on charge. (iii) Old U/s CI/DI/MS Pipe scrap material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
100 mm bore

100

-

-

... More
150 mm bore

120

-

-

... More
200 mm bore

100

-

-

... More
Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ. Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates. Note 3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site. Note 4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly. Note 5:- Layout plan for laying of DI pipe shall be given by EIC in writing. Note 6 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates.)

-

-

-

... More
100 mm bore

100

-

-

... More
150 mm bore

120

-

-

... More
200 mm bore

100

-

-

... More
Labour for cutting of existing CI / DI pipe for insertion of CI specials etc. all as required including dewatering of lekage water all as required of the following size complete all as specified and as directed .

-

-

-

... More
100 mm bore

4

-

-

... More
150 mm bore

4

-

-

... More
200 mm bore

4

-

-

... More
Supply and fixing DI / CI in replacement MJ Collar fittings all as per IS: 9523 (2000) of following sizes all as specified and directed by Engr-in-Charge. (Note:- Old U/s DI/CI/MS Collar fitting material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
100 mm dia

3

-

-

... More
150 mm dia

3

-

-

... More
200 mm dia

2

-

-

... More
250 mm dia

2

-

-

... More
300 mm dia

2

-

-

... More
400 mm dia

1

-

-

... More
S&F in replacement three Pole Power Contactor 25 Amp 415/440 volts 50 HZ type ML 1.5 or MNX Type range 25 Amps complete all as specified and directed

3

-

-

... More
S&F in replacement three Pole Power Contactor 32 Amp 415/440 volts 50 HZ type ML 3 or MNX Type range 40 Amps complete all as specified and directed

3

-

-

... More
S&F in replacement Bimetal Over load relay for ML 1.5 or MNX Type with range 9-14 Amp complete all as specified and directed

6

-

-

... More
S&F in replacement Bimetal Over load relay for ML 2 or MNX Type with range 13-21 Amp complete all as specified and directed

4

-

-

... More
S&F in replacement Bimetal Over load relay for ML 3 or MNX Type with range 20-32 Amp complete all as specified and directed

3

-

-

... More
S&F in replacement of FASD ML-1.5/MN 16 Type with relay range 9-15 Amps complete all as specified and directed

3

-

-

... More
S&F in replacement of FASD ML-2.0/MN 25 Type with relay range 14-23 Amps complete all as specified and directed

2

-

-

... More
(Note for ser item No 24 to 30 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Supply and fix in replacement of 3 Pole MCCB, 63 Amp, 50 Hz, 415 V with rupturing capacity 10 KA 'C' Curve complete all as specified and directed

4

-

-

... More
Supply and fix in replacement of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA 'C' Curve complete all as specified and directed

6

-

-

... More
Supply and fix in replacement of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA 'C' Curve complete all as specified and directed

4

-

-

... More
S&F in replacement moulded case circuit breakers 4 pole 400 Amps 415 volts having breaking / rupturing capcity 36 KA 'C' Curve complete all as specified and directed

2

-

-

... More
Supply and fixing in replacement of GM ball valve of sizes 12 mm dia bore including coolling pipe with check nuts, suitable length of GI nipples etc complete for Centrifugal Pump Sets complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement Pressure gauge of suitable pressure upto 14 Kgs/cum all as existing including necessary fitting, complete all as specified and directed.

8

-

-

... More
(Note for ser item No 31 to 36 :- Old U/s fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
M&L for testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) one test in one month for one source in the area under AGE (U) W/S No-III as directed by EIC and submission of detailed test report to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle and testing in Govt Approved laboratory as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission to this office with specific recommendation regarding suitability of water for drinking purpose. Note :- Rate quoted shall deemed to be included for : - (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source(sump/bore well/shallow wells) (iii) Contractor will required to visit the site of AGE (U) W/S-III area for working out number of sources i.e borewells/shallow wells/under ground sumps etc. Approximately 40 Number of tests will be carried out in eleven months period. (iv) Period of testing of water sources is of 11 (Eleven) months from the commencement of work. (v) Mode of payment: - Payment will be made after completion of work as one JOB for 11 (Eleven) months for number of tests. Part payment will be allowed after dividing number of months in quoted unit rate.

1

-

-

... More
S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed

40

-

-

... More
S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete all as specified & directed

10

-

-

... More
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed

10

-

-

... More
S&F modular socket outlet 2 in 1, 5 pin, 16 Amps, flush type, 230 volts with socket frame complete all as specified & directed

10

-

-

... More
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 120 watts including connection complete all as specified & directed

10

-

-

... More
S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified & directed

6

-

-

... More
(Note for ser item No 38 to 43 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Supply only PVC insulation tape role 15mm wide, 10 Running meter long complete all as specified and directed.

20

-

-

... More
Supply only PVC adhisive tape role 15mm wide, 10 Running meter long complete all as specified and directed.

20

-

-

... More
Supply only Ceiling rose 3 terminal PVC/Polycarbonate, isolated body 230 volt complete all as specified and directed.

25

-

-

... More
Supply only following electrical items:-

-

-

-

... More
MCB SP 6 to 32 Amp, 240 volts 'C' Curve complete all as specified and directed.

10

-

-

... More
SPN 40 Amp , 240 volts 'C' Curve complete all as specified and directed.

8

-

-

... More
Supply and fixing in repair copper terminals lugs (Thimbles) ring type medium duty for following sizes :-

-

-

-

... More
25 Sqmm

40

-

-

... More
35 Sqmm

40

-

-

... More
50 Sqmm

50

-

-

... More
70 Sqmm

30

-

-

... More
95 Sqmm

30

-

-

... More
Supply and fixing in repair Aluminium terminals lugs (Thimbles) ring type medium duty for following sizes :-

-

-

-

... More
16 Sqmm

60

-

-

... More
25 Sqmm

60

-

-

... More
35 Sqmm

50

-

-

... More
50 Sqmm

40

-

-

... More
70 Sqmm

40

-

-

... More
95 Sqmm

35

-

-

... More
120 Sqmm

35

-

-

... More
150 Sqmm

25

-

-

... More
185 Sqmm

15

-

-

... More
240 Sqmm

15

-

-

... More
Supply, fixing and laying of LT XLPE UG armoured , heavy duty electric cable with aluminium conductor, 1100 volts grade, of cross siectional area of following sizes including taking down the existing XLPE cable one and deposited to MES store yard all as directed:- (Note :- (a) Excavation & earth work brick protection & sand cushioning shall be measured and paid seperately under respective items. (b) Layout plant shall be given by Engineer-in-Charge to contractor in writing. (c) Old U/s aluminium conductor scrap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
16 Sqmm, 4 core

100

-

-

... More
35 Sqmm, 3.5 core

150

-

-

... More
50 Sqmm, 3.5 core

200

-

-

... More
70 Sqmm, 3.5 core

200

-

-

... More
95 Sqmm, 3.5 core

100

-

-

... More
120 Sqmm, 3.5 core

100

-

-

... More
(Note for ser item No 44 to 50.06 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Supply and filling sand free from vegatation & dust in cable ducts/ trenches with and including removing old sand to a distance not exceeding 50 mtr away and depositing where directed by Engineer-in-charge. (Note:- Punned depth of sand shall be measured and paid.)

15

-

-

... More
Supply and fixing in repair connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 60 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm including mild steel bracket of length 120cm of 40mm dia 'medium grade' complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 35 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm including mild steel bracket of length 120cm of 40mm dia 'medium grade' complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.

50

-

-

... More
(Note for ser item No 52 to 54 :- Old U/s light fitting & steel bracket material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Suply, fixing & installation testing commissioning (By OEM Rep) LED Solar street light fitting of capacity 16 Watt including galvanized steel pole of 50 mm dia 'heavy duty' 1.2Rm height fixed in PCC block, built in lithium ion battery, solar panel, charge controller with dusk down sensor including taking down of existing unserviceable solar light & pole complete all as specified and directed. (Note:- (i) Excavation & earth work shall be measured separately. (ii) Old U/s iron scrap material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap weight (KG) shall be taken into account and attach with RAR/F Bill)

2

-

-

... More
Repair to Water Level Indicator (Mechinical type) installed at semi under ground water reserviors including providing greasing the pully, including adjustment of steel rope/float ball for its proper calibration and replacement of existing unserviceable nut and bolt, pully, float ball and steel rope making functional for its smooth effecient functioning complete all as specified and directed. (Note:- (i) Float ball and steel rope shall be measured and paid for seperately. (ii) Old U/s iron scrap material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap weight (KG) shall be taken into account and attach with RAR/F Bill)

4

-

-

... More
Supply and fixing steel rope stranded flexible 3 mm dia complete all as specified and directed as per sample.

25

-

-

... More
Suply & fixing in replacement of Brass ball of size 300 mm bore complete with suitable size u clamps for manual water level indicator complete all as specified and as directed

4

-

-

... More
Surface dressing for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installation/around the valve pit chamber/along the pipe line routes etc and getting out soft/loose soil, all as specified and as directed at site by Engineer-in-Charge. (Cost of removal of rubbish, bush/vegitation out side MoD land will deemed included in quoted unit rate.

1200

-

-

... More
M&L in replacement Earthing complete with galvanised steel earth plate ectrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and directed or indicated including testing on completion complete all as specified and directed.

10

-

-

... More
(Note:- (i) Old U/s iron material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap weight (KG) shall be taken into account and attach with RAR/F Bill. (ii) GI Strip upto 7.5 Rm from earth test point will be deemed included in quoted unit rate.

-

-

-

... More
Supply and laying of rubber insulated mat of size 2.00 mtr x 1.00 mtr of 19 mm thick ISI marked complete all as specified and as directed by Engr-in-charage.

5

-

-

... More
Supply and fixing rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed. (Note:- Old U/s obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

2

-

-

... More
Supply and fixing rotational moulded polyethylene water storage tanks, cylindrical vertical with closed top, 1000 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed. (Note:- Old U/s obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

2

-

-

... More
S&F in replacement of stainless steel work of satinless steel of grade SS-304 any shape/sizes of angles irons/flat iron/MS sheet/circuler etc including necessary cutting and welding, works and writing works Flesh sheet (fancy text) of suitable size of writting complete all as specified and directed by Engr-in-charge. (Note:- Old U/s Stainless Steel obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV iin weight (KG) shall be taken into account and attach with RAR/F Bill.

450

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.

230

-

-

... More
Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed by the Engineer-in-charge.

224

-

-

... More
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed.

6

-

-

... More
Supply & laying of bricks sub class 'B' old size laid across the cable above the sand cushioning for protection of cable width equal to length complete all as specified and directed

1500

-

-

... More
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:6 including demolition of existing brick work complete all as specified and directed. (Note:- Old U/s brick/brick bats obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in volumn (CUM) shall be taken into account and attach with RAR/F Bill.

5

-

-

... More
M & L PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.

4

-

-

... More
M&L Machine pressed precast concrete rubber moulded interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-30 Grade with grey cement and colour pigments over and including 40 mm thick sand cushioning complete all as specified and as directed. (Note:- Excavation and earth work shall be measured and paid seperately under respective items).

30

-

-

... More
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends, removal of fault & reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE: (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.

4

-

-

... More
M & L for making arrangement to fix reversible gear motor of cap. 01 HP working at AC 415 volts 50 Hz suitable for opening and closing of existing suction/delivery sluice gear valve of any make and size with and including connecting cable of suitable size and DOL stater with enclouser and all connecting/ fixing arrangements etc complete all as specified and directed by Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)

6

-

-

... More
S&F in replacement of exaust fan copper wounded motor of size 300 mm sweep, heavy duty working at AC 240 volt, 50 Hz with 1450 rpm complete with louver, including nut-bolts, washer and twin core cable upto 5 RM complete all as specified and directed by Enginner-in-charge. (Note :-Old exaust fan shall be taken on charge and 'RV' attach with the bill.)

5

-

-

... More
S&F in replacement of PVC insulated multistranded copper conductor cable single core 1100 Volts grade of following sizes:- (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV copper conductor in weight (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
16 sqmm

15

-

-

... More
25 sqmm

20

-

-

... More
50 sqmm

20

-

-

... More
95 sqmm

15

-

-

... More
Supply, Installation Testing & Commissioning of ULTRASONIC LEVEL SENSORS Water Level Sensor for underground tank suitable for up to 6 meter water level depth of U/G sump, with dead band of less than 0.6meter, IP66 protection, accuracy of 0.25% of F.S. and RS485 Modbus RTU communication protocol, Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply, LCD display type, vertical type mounting on top of OHTs with all connections and fixing including clamp, nut-bolt etc in replacement complete all as specified and as directed. (Note:- Old U/s material water level sensor obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.)

4

-

-

... More
M&L incls fabrication of glow ditribution diagram of pipeline network including showing of all Pumps, Headers, Valves and pipeline of different sizes etc comprising of printing of complete distribution diagram on Vinyl sheet, weather proof and pasting the same on bakelite sheet min 3 mm thick of Size 1500mm x 2400mm x 150mm thick fixed on MS frame of similar size made out of square MS Pipe of size 25 mm x 25 mm with proper back lighting for proper illumination and proper color legends for all the feeders, pumps and valves with proper circuit controlled wiring of suitable size and one top plug 3-Pin 5 Amp including fixing the same at the pump house wall and including all fixing material required in replacement complete all as specified and directed. (Note:- Old U/s material glow sign board obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.)

2

-

-

... More
M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge. (Note:- Photographs of location date wise where weeds and wild grass of istallations required to be removed before execution and after completion of work will enclosed with RAR for payment purpose. If photographs not found attached with RAR, the same payment will not be allowed).

1500

-

-

... More
M&L Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc with two coat of synthetic enamel paint over a coat of red oxide primar and incl lifting handle and taking out the old unsv valve chamber cover complete all as specified and directed. (Note:- Old U/s material cover obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.

300

-

-

... More
M&L for painting of existing Steel/RCC surface with two coat of Black/Blue colour synthetic enamelled paint over a coat of red oxide primer including preparation of old steel surfaces complete all as specified and directed.

300

-

-

... More
M&L writing letter or figures (Block, Roman, Italic of Indian) not exc 30cm high and not exc. 20cm in width letter shall be painted with 02 mm thick synthetic enamel paint so that they stand out boldly and solidly without showing signs or brush mark complete all as specified and directed. (Note:- Comma/oblique/ desh etc shall not be measured and paid. Cost of these shall be deemed included in quoted rate of letters. Only letters will be measured & paid.)

1000

-

-

... More
Material and labour of painting with two coat supper enamelled paint with of Pump set including electric driven motor, coupling, base frame, sluice valve, NRV etc of capacity up to 200 HP complete with all as specified and as directed by Engineer-in-charge.

8

-

-

... More
M & L for painting of Sluice valve, NRV upto 450 mm bore with two coat of supper enamelled paint over a coat of red oxide primer including preperation of old surface complete all as specified and as directed by Engineer-in-charge.

10

-

-

... More
S & F in replacement of air vent pipe of size 150 mm bore UPVC pipe 10 kgs/cum pressure heavy duty of length 0.30 mtr long and 2 nos of UPVC bend of semi under ground reservoir any capacity including necessay PCC complete all as specified and as directed by Engineer-in-charge. (Note:- Old U/s PVC scrap material glow sign board obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.)

30

-

-

... More
Supply and fixing in replacement of domestic type water flow meter class 'B' conforming to IS :779/1994 complete all as specified and directed. (Note:- Old U/s iron scrap material glow sign board obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.)

-

-

-

... More
100 mm bore

2

-

-

... More
250 mm bore

1

-

-

... More
350 mm bore

1

-

-

... More
M & L Construction of valves pit chamber having intermal dimention 120 cm x 120 cm x 120 cm (internal size) using PCC (1:4:8) 40mm graded stone aggregate for foundation 15 cms. Thick, 23 cm tick wall in CM (1:4), 10mm tick rendering all around the brick work with 1:6 cement mortar, PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm tick MS top sheet cover with locking arrangement including 50mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surpuls soil to a distance not exceeding 50 mtrs all as specified and shwn on drg No CWE (U)/D-1/86 sheet No 1/1 and includung demolition/ dismentling of existing valve chamber complete all as specified and as directed.

3

-

-

... More
M & L Construction of valves pit chamber having internal dismention 220 cm x 180 cm x 150 cm (internal size) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm thick MS top sheet cover in 2 pieces with locking arrangement including 50 mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs including demolition/dismentling of existing valve pit chamber complete all as specified and as directed. (Note for Item No 86 & 87 :- Old U/s material valve pit chamber obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of brick work in CUM & Iron Scrap in (KG) shall be taken into account and attach with RAR/F Bill.)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.