Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 53,940Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_648642_1Bid Award Id
ViewTender No
GE(U)/PM/D-78/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & fixing in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed .
6
-
-
... More
Supply & fixing in replacement PVC flexible drain Hose Pipe 40 mm complete all as specified and as directed .
5
-
-
... More
Supply & fixing in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed . ( Suitable for Voltas/Sidwal/Blue Star make water coolers).
5
-
-
... More
Supply & fixing in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed .
6
-
-
... More
Supply & fixing in replacement PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Litre capacity water coolers including GI socket of same size complete all as specified and as directed .
6
-
-
... More
Supply & fixing in replacement Starting Capacitor 25 MFD complete all as specified and as directed .
5
-
-
... More
Supply & fixing in replacement running Capacitor 10 MFD complete all as specified and as directed .
5
-
-
... More
Supply and fixing in replacement Starting relay suitable for 40/80, 60/120, 150/150 Litre complete all as specified and as directed .
5
-
-
... More
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed.
6
-
-
... More
All as per item No.12.00 above but 1/32 HP Water cooler of Capacity 40/80 Litres.
5
-
-
... More
Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers, commissioning and testing of Water Coolers of 40/80 Litres capacity complete all as specified and as directed.
4
-
-
... More
Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers , commissioning and testing of Water Coolers of 60/120 Litres capacity complete all as specified and as directed.
3
-
-
... More
Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers , commissioning and testing of Water Coolers of 150/150 Litres capacity complete all as specified and as directed.
3
-
-
... More
Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Litres complete all as specified & as directed.
2
-
-
... More
Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Litres complete all as specified & as directed.
2
-
-
... More
Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Litres, checking the leakages of gas and rectify the leakages by brazing or as other manner complete all as specified & as directed (Make :- As per Sample)
5
-
-
... More
Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
5
-
-
... More
Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keeping the AC unit in satisfactory working condition after necessary servicing as required and refixing the same in existing position complete all as specified and as directed .
150
-
-
... More
All as per srl item No 21.00 here-in-before but window type AC of capacity 1.5/ 2 TR complete all as specified and as directed.
30
-
-
... More
All as per srl item No 21.00 here-in-before but Tower type AC of any capacity complete all as specified and as directed.
1
-
-
... More
Material & Labour for changing mode of any type of AC from heating mode to cooling mode or vice-versa complete all as specified and as directed.
100
-
-
... More
Material & Labour for rectifying electrical wiring fault of any capacity type AC and make them functional and also carry out the required repair complete all as specified and as directed.
50
-
-
... More
Notes for item No. 21.00 to 25.00 (i) Adequate resources and manpower shall be deployed by the contractor for attending day to day defect being an essential installation. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as and when asked complete all as specified and as directed.
(iii) All complaint/repairs shall be attended/completed within 06 Hour failing which a recovery of Rs 500/- per day per complaint shall be made from contractor dues.
-
-
-
... More
Supply & fixing in replacement Running capacitor 36+6 MFD complete all as specified and as directed .
20
-
-
... More
Supply & fixing in replacement Running capacitor 45+5 MFD complete all as specified and as directed .
20
-
-
... More
Supply & fixing in replacement Running capacitor 50+6 MFD complete all as specified and as directed .
20
-
-
... More
Supply & fixing in replacement Starting capacitor 80-100 MFD complete all as specified and as directed .
10
-
-
... More
Supply & fixing in replacement Starting capacitor 100-120 MFD complete all as specified and as directed .
10
-
-
... More
Supply & fixing in replacement Starting Relay 1622 complete all as specified and as directed .
12
-
-
... More
Supply & fixing in replacement Starting Relay 2000 complete all as specified and as directed .
12
-
-
... More
Supply & fixing in replacement Thermostat switch 2059/2064/205 complete all as specified and as directed .
15
-
-
... More
Supply & fixing in replacement Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic complete all as specified and as directed .(Make as per site requirement.)
10
-
-
... More
Supply & fixing in replacement Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic complete all as specified and as directed .(Make as per site requirement.)
20
-
-
... More
Supply & fixing in replacement Wiring kit for Window/split type AC of Capacity 1.5/2 TR complete all as specified and as directed . (Make as per site requirement.)
20
-
-
... More
Supply & fixing in replacement remote control of existing make including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed
20
-
-
... More
Taking down unserviceable reversible valve for split AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required different copper pipe with PCB and remote alteration/modification complete all as specified and directed. Note :- (i)Supply & filling of refrigerant gas shall be measured and paid under relevant item.) (ii) Any alteration or modification including electronic component required in PCB and Remote to be paid under relevant items.
15
-
-
... More
ditto- all as per item No. 38.00 above but window type Air Conditioner of capacity 1.5 TR.
15
-
-
... More
ditto- all as per item No. 38.00 above but window type Air Conditioner of capacity 2 TR.
10
-
-
... More
ditto- all as per item No. 38.00 above but spilt type Air Conditioner of capacity 2 TR.
10
-
-
... More
Material & Labour for Carryout the repairing work in remote control of AC of any type and any capacity complete all as specified and directed to be included in above quoted rates.
10
-
-
... More
Material & Labour for Carryout the pressure test with nitrogen gas of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
50
-
-
... More
Taking down, repairing and re-fixing main printed circuit board (PCB) with electric accessories and sensors suitable for inverter type split type AC/ window type AC of any capacity and model complete all as specified and directed.
10
-
-
... More
Supply & fixing in repair PCB, suitable for inverter type, split type AC/ window type AC of any capacity and model complete all as specified and as directed.
10
-
-
... More
Taking down, repairing and re-fixing PCB, suitable for split type AC/ window type AC of any capacity and model complete all as specified and directed.
15
-
-
... More
Supply & fixing in repair PCB suitable for split type AC/ window type AC of any capacity and model complete all as specified and as directed.
10
-
-
... More
Supply & fixing in repairs plastic louvers for (Front panel) for Window AC 1.5/2 TR complete all as specified & as directed (Make as per Sample).
5
-
-
... More
Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as specified & as directed. Note :- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set
(ii) Supply & filling of refrigerant gas shall be measured and paid under relevant item.
5
-
-
... More
Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample).
10
-
-
... More
Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample).
10
-
-
... More
Disconnecting from mains and taking out existing unserviceable sealed compressor unit and supply & fixing in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 1.5 TR window type AC/ Split AC of existing capacity and make complete including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc and commissioning complete all as specified & as directed.
20
-
-
... More
ditto- all as per item No. 52.00 above but suitable for 2.0 TR window type AC/ Split AC.
10
-
-
... More
Supply & fixing in replacement of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
10
-
-
... More
Supply & fixing in replacement of Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
10
-
-
... More
Supply & fixing in replacement of copper wounded motor for outdoor of Split type AC of 1.5 TR & 2 TR capacity complete all as specified & as directed.
10
-
-
... More
Material & Labour for Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
5
-
-
... More
ditto- all as per item No. 57.00 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
5
-
-
... More
Material & Labour for Disconnecting the mains and taking out the unserviceable evaporator/cooling coil of window type AC of capacity 1.5 TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
5
-
-
... More
ditto- all as per item No. 59.00 above but Window type Air Conditioner Capacity 2 TR.
5
-
-
... More
Taking down unserviceable outdoor unit of split type AC of any capacity complete all as specified and as directed .
25
-
-
... More
Supply and fixing 1.5 TR capacity split type Air Conditioner outdoor kit with latest refrigerant gas compatible including condenser coil with protection fins, blower motor and its fan blade, chassis & base plate with outdoor covering without compressor, suction and discharge valve, capillary tube of expansion valve, contactor with PCB card, capacitors and copper pipes & PVC wires of suitable size for internal connection, etc. complete all as specified & as directed.
20
-
-
... More
ditto- all as per item No. 62.00 above but spilt type Air Conditioner of capacity 2 TR.
5
-
-
... More
Taking down unserviceable indoor unit of split type AC of capacity 1.5 TR / 2 TR with remote complete all as specified & as directed.
25
-
-
... More
Supply & fixing new indoor unit with remote control and with latest refrigerant gas compatible complete set suitable for 1.5 TR capacity complete all as specified & as directed.
20
-
-
... More
ditto- all as per item No. 65.00 above but spilt type Air Conditioner of capacity 2 TR. Note for item No. 62.00 to 66.00:- Outdoor and indoor unit of AC shall be compatible either with each other or existing units
5
-
-
... More
Disconnecting from mains and taking out existing unserviceable sealed inverter DC compressor unit and supply & fixing in replacement sealed inverter DC compressor unit with latest refrigerant gas compatible, suitable for 1.5 TR window type AC/ Split AC of existing capacity and make complete including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc commissioning complete all as specified & as directed.
15
-
-
... More
Taking down unserviceable indoor unit of inverter split type AC of capacity 1.5 TR and supply & fixing new inverter type indoor unit complete set suitable for 1.5 TR capacity complete all as specified & as directed.
10
-
-
... More
Supply and fixing in repairs 1.5 TR capacity inverter type split type Air Conditioner outdoor kit including condenser coil, blower motor, chassis, base plate , suction and discharge valve, contactor, capacitors and copper pipe, PVC wires, PCB compatible to indoor unit, of suitable size for internal connection, etc. including taking down old unserviceable one complete all as specified & as directed.
10
-
-
... More
Supply & fixing in replacement heavy duty copper pipe 12mm (1/2") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and as directed.
90
-
-
... More
ditto- all as per item No. 70.00 above but copper pipe 6mm (1/4") dia/ bore.
30
-
-
... More
ditto- all as per item No. 70.00 above but copper pipe 15mm (5/8") dia/ bore.
30
-
-
... More
ditto- all as per item No. 70.00 above but copper pipe 10mm (3/8") dia/ bore.
50
-
-
... More
Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitable for Split AC of capacity from 1.5 to 4.0 TR complete all as specified & as directed.
100
-
-
... More
Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC complete all as specified & as directed.
50
-
-
... More
Material & Labour for complete topping up the refrigerant gas( R22) in split/window type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
20
-
-
... More
Material & Labour for complete topping up the refrigerant gas( R22) in split/window type 2.0 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
20
-
-
... More
Material & Labour for complete topping up the refrigerant gas( R32/ R410A) in split/window AC type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
20
-
-
... More
Material & Labour for complete topping up the refrigerant gas( R32/R410A) in split/window AC type 2.00 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
20
-
-
... More
Material & Labour for complete topping up the refrigerant gas( R22/ R32/R410A) in tower AC type & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
20
-
-
... More
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for window/ Split AC 1.5 to 2.0 TR complete all as specified & as directed.
10
-
-
... More
Taking down unserviceable contactor and supply and fixing new contactor ( MNX 12/ MNX 18) suitable for tower AC up to 4.0 TR capacity complete all as specified & as directed.
5
-
-
... More
Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed.
5
-
-
... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed .
5
-
-
... More
Supply and fixing in replacement UPVC piping of dia 25mm complete with fittings, supports and duly covered complete all as specified & as directed.
5
-
-
... More
Supply & fixing in replacement Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed.
5
-
-
... More
Dismantling and Refixing the Split AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with Outdoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing, gas charging, Carpentry work, Plumbing, masonry & white cementing complete all as specified & as directed. Note :-
Drain Pipe, Copper of required size, Refrigerant gas , Outdoor stand , power plug, MCB and Copper wire will be paid under relevant items.
5
-
-
... More
Supply and fixing in repairs 1.5 TR capacity window type AC kit including condenser coil & evaporator coil (copper), copper wounded blower motor, cooling coil, front grill blower motor, chassis, base plate, reverse valve, capacitors and copper pipes & PVC wires of suitable size for internal connection etc including taking down old one complete all as specified and as directed .
5
-
-
... More
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of adequate size with all fittings and casing capping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed.
60
-
-
... More
ditto- all as per item No. 89.00 above but sub main wiring with two runs of single core 4 Sqmm
50
-
-
... More
Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed.
10
-
-
... More
Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed.
10
-
-
... More
Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed.
5
-
-
... More
Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed.
5
-
-
... More
Taking down for servicing of split type AC 3.5 TR Capacity, 3 phase, including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, Remote control unit including PCB, fan, blower, etc., and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed.
Note:-
(i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
12
-
-
... More
Supply only printed circuit board (PCB) compatible with electric accessories and sensors suitable for indoor of split type AC of capacity of 3.5 TR.
2
-
-
... More
Supply only Relay suitable for Split type AC of capacity 3.5 TR .
2
-
-
... More
Supply only in Power Contactor suitable for Split type AC of capacity 3.5 TR Note for item Nos. 96.00 to 98.00:-
Materials of item Nos. 96.00 to 98.00 to be incorporated in item No 95.00 here-in-before.
3
-
-
... More
Supply & fixing heavy duty copper pipe 6/8" dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed.
20
-
-
... More
Supply and fixing capacitors suitable for Split type AC of capacity 3.5 TR complete all as specified and as directed
10
-
-
... More
Dismantling and removing defective burnt blower unit motor of capacity 3.5 TR of any make of indoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and directed.
2
-
-
... More
Dismantling and removing defective burnt Condenser fan motor of any make for outdoor units of split type AC of capacity 3.5 TR and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and directed.
3
-
-
... More
Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 3.5 TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed.
3
-
-
... More
Disconnecting the mains and taking out the unserviceable condenser coil of Split Type AC of capacity 3.5 TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:-Suitable for Voltas/Intel/LG/ Emerson/ Blue Star)
3
-
-
... More
Disconnecting the mains and taking out the unserviceable Evaporating/ cooling coil of Split Type AC of capacity 3.5 TR of any make from any location and supply, fixing and testing new Evaporating/ cooling coil as per existing size & patterns for complete all as specified & as directed. (Make:-Suitable for Voltas/Intel/Emerson/LG/Blue Star)
2
-
-
... More
Supply & fixing in repair Indoor Air blower motor suitable for Split type AC 3.5 TR capacity complete all as specified & as directed.
3
-
-
... More
Supply & fixing in repair Condenser fan motor suitable for Split type AC 3.5 TR capacity complete all as specified & as directed.
4
-
-
... More
Supply & fixing in repairs Split AC Condenser fan blade plastic body for 3.5 capacity AC complete all as specified & as directed.
5
-
-
... More
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Split type Air Conditioner of Cap 3.5 TR, 3 Phase, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor and one year guarantee certificate of existing type including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-410A/R-32 and commissioning complete all as specified & directed.
Note :- Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
4
-
-
... More
Supply & fixing in replacement wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed.
10
-
-
... More
M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning as specified and re-fixing to existing place after servicing work complete all as specified and directed.
80
-
-
... More
Supply and fixing in replacement wood wool pad of suitable size for 24” sweep desert cooler, 01 Set comprising of 3 Nos of pads approximate weight 800-900 Gms as per sample complete all as specified & as directed.
80
-
-
... More
Supply and fixing in replacement submersible pump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified and as directed .
80
-
-
... More
Supply and fixing in replacement front grill for desert cooler of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp complete all as specified and as directed .
40
-
-
... More
Supply and fixing in replacement running capacitor of 4 MFD capacity for water cooler complete all as specified and as directed .
40
-
-
... More
Supply and fixing in replacement running capacitor of 6 MFD capacity for water cooler complete all as specified and as directed .
40
-
-
... More
Supply and fixing in replacement wire mesh for desert cooler pad (Set of Three) including taking down old one complete all as specified and as directed .
80
-
-
... More
Supply and fixing in replacement PVC pipe for connecting pump and water distributor of size 15 mm dia including PVC elbows complete all as specified and as directed .
40
-
-
... More
Supply and fixing in replacement PVC elbow for desert cooler of suitable size complete all as specified and as directed .
80
-
-
... More
Supply and fixing in replacement PVC 4 Way distribution cross for desert cooler complete all as specified and as directed .
80
-
-
... More
Supply and fixing in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and as directed.
30
-
-
... More
Supply and fixing Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and as directed.
30
-
-
... More
Supply and fixing in repairs of flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm with permanently joined top of 15 amps complete all as specified and as directed. (Length of wire about 1meter)
30
-
-
... More
Supply and fixing in repairs desert coolers fan blade of 18" (inch) sweep make out of Aluminium complete all as specified and as directed .
25
-
-
... More
Supply and fixing in repairs switch piano flush type single pole one way 5Amp 230 V for desert cooler complete all as specified and as directed .
10
-
-
... More
Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed.
20
-
-
... More
Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers i.e. side panel, bracket, body & desert cooler stand with two coats of synthetic enamelled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height at stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as specified & as directed.
80
-
-
... More
Supply and fixing in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) of sheet 22 Gauge and with side panels (03 Nos) fabricated out of 24 SWG PGI Sheet along with PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e., side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white complete all as specified & as directed.