Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 84,294Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682863_1Tender No
NIT No GE/ND-90/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, installation, testing and commissioning of Ductable Units capacity of 9.0 TR (3400 CFM) (Library) with evaporator coil, fan and Fan motor, corded remote control, and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply as required complete all as specified and directed by Engg in charge.
2
-
-
Supply, installation, testing and commissioning of Verticool Units capacity of 4.0 TR (1060 CFM) (Anchor Bar) with evaporator coil,fan and Fan motor, cordless remote control, and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply as required complete all as specified and directed by Engg in charge.
3
-
-
Supply, installation, testing and commissioning of Floor Mounted AHU Units capacity of 22.0 TR (8800 CFM) (Library) with evaporator coil,fan and Fan motor, corded remote control, AHU Kit (Control Kit + Expansion kit) and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply for Kit & 480V - % 50 Hz Three phase AC supply for AHU as required complete all as specified and directed by Engg in charge.
Make: Zeco, Edgetch, Bluestar, Wave
2
-
-
S&F refrigerant Y-Joint for Combining Outdoor and Indoor Units required for distribution of refrigerant in copper piping as per final approved drawing which will be submitted by OEM complete all as specified and directed.
5
-
-
Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of size 9.5mm with 13mm thick insulation including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping intall on cable trays with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed by Engg in charge.
Make: Mandev, Maxflow, Rajco
34
-
-
All as per item No 8.00 above but size 12.7 mm with 13 mm thick insulation complete all as specified and directed by Engg in charge.
22
-
-
All as per item No 8.00 above but size 15.9 mm with 13 mm thick insulation complete all as specified and directed by Engg in charge.
22
-
-
All as per item No 8.00 above but size 19.1 mm with 13 mm thick insulation complete all as specified and directed by Engg in charge.
22
-
-
All as per item No 8.00 above but size 22.2 mm with 19 mm thick insulation complete all as specified and directed by Engg in charge.
34
-
-
All as per item No 8.00 above but size 28.6 mm with 19mm thick insulation complete all as specified and directed by Engg in charge.
26
-
-
All as per item No 8.00 above but size 34.9 mm with 19mm thick insulation complete all as specified and directed by Engg in charge.
22
-
-
All as per item No 8.00 above but size 38.1mm with 19mm thick insulation complete all as specified and directed by Engg in charge.
32
-
-
Supply and fixing in position the 32mm dia of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category complete all as specified and directed by Engg in charge.
70
-
-
Supply, fixing, testing and commissioning of 2 Core x 0.75mm² control wiring (Sheilded Wire) from outdoor , indoor units to the central controller with all necessary accessories to make it functional as per OEM Recommendation complete all as specified and directed by Engg in charge.
Make: PolyCab, Havells, Finolex
250
-
-
Supply and fixing of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel complete all as specified and directed by Engg in charge.
4
-
-
Supply, Charging of Refrigerant Gas R410a as per OEM Recommendation (Make:- SRF Floron, Honeywell & Dupont) complete all as specified and directed by Engg in charge.
80
-
-
Supply and fixing of 125mm deep Antivibration Flexible Joints made out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units complete all as specified and directed by Engg in charge.
4
-
-
Supply , assembly and erection GI sheet of 25 Gauge rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, Cleat , Carrige bolt, Gasket and appropriate sealant on langitudinal joints etc complete including necessary MS Channels, Gurder supports as approved by Engr-in-charge including making of hole in any type of wall and making good with plastering work , masonry work and necessary MS channel supports complete all as specified and directed by Engg in charge.
50
-
-
All as per item No 21.00 above but size 22 Gauge complete all as specified and directed by Engg in charge.
80
-
-
Supply & erection of 19 mm thick nitrile duct insulation with Aluminum foil. The thermal insulation shall be 25 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically crosslinked polythylene foam, confirming to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminum foil complete all as specified and directed.
100
-
-
Supply and fixing insulation acoustic lining of supply air ducting complete with GI frame , tissue paper , 26 Guage perforated AL Sheet 25mm thick of density 32 kg/cum fiber glass insulation complete all as specified and directed.
100
-
-
S&F of Acoustic treatment/ lining of area of AHU room with 22 Gauge, GI channels of 50x50 mm size fitted at 600x600mm girds, fitted with 50mm thick, 32 Kg/cum fibber glass insulation, covered with fibber glass tissue and 24 Gauge Aluminium perforated sheet as required, The joint shall be with minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering, All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed.
150
-
-
Supply and fixing of fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct with nuts , bolts complete all as specified and directed.
4
-
-
Supply, installation, testing and commission of UL-555 motorized fire dampers complete with smoke detector/ thermister linkage etc in Supply Air Ducts as required for operation complete all as specified and directed.
4
-
-
Supply, installation, testing and commission of Actuator with control panel Supply Air Ducts as required for operation complete all as specified and directed.
4
-
-
Supply, installation ,testing of supply air Grills and without volume control dampers, power coated , extruded aluminium construction complete all specified and as directed.
10
-
-
Supply, installation ,testing of supply air Grills and volume control dampers , power coated , extruded aluminium construction complete all specified and as directed.
10
-
-
M&L for control wiring with 4 core X 1.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
40
-
-
M&L for control wiring with 4 core X 16sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
40
-
-
M&L for control wiring with 4 core X 10sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
10
-
-
M&L for control wiring with 4 core X 6sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
10
-
-
M&L for control wiring with 4 core X 4sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
40
-
-
M&L for control wiring with 3 core X 2.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
40
-
-
M&L for control wiring with 3 core X 1.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed
Make : Finloex/Havells/Polycab
(Note : Four run of wire with PVC conduit will be considered as one Length.)
45
-
-
S & F MCB SP, 240 Volts, 5 to 40 Amps 240 V/415 V, 50 Hz, 10 kA complete all as specified and directed.
7
-
-
S & F MCB TPN, 40Amps 240 V/415 V, 50 Hz, 10 kA complete all as specified and directed.
3
-
-
S & F MCB TPN, 63Amps 240 V/415 V, 50 Hz, 10 kA complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%