Military Engineer Services Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Aug 2020
Closing Date27 Aug 2020
Tender Amount₹ 49,76,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Laying only old bricks obtained from excavation complete all as directed.

4600

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover of following sizes:-

-

-

-

... More
Class HV, type 1, for 11 KV flat size 300 mm x 180 mm x 40mm.

3800

-

-

... More
Class HV, type 1, for 33 KV flat size 450 mm x 230 mm x 40mm.

250

-

-

... More
Laying only old HT cable cover obtained from excavation complete all as directed.

750

-

-

... More
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.

643

-

-

... More
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.

307

-

-

... More
Disconnecting faulty 11 KV HT cables of different sizes from both ends, testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.

48

-

-

... More
All as per item Ser No 9 above but 1100 Volt LT cables

50

-

-

... More
Supply, laying, jointing, testing and commissioning in replacment LT underground cables of size 10 sqmm 4 core 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed. Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.

200

-

-

... More
All as per srl item No 11 here-in-before but of size 16 Sqmm 4 core

200

-

-

... More
All as per srl item No 11 here-in-before but of size 25 Sqmm 4 core

200

-

-

... More
All as per srl item No 11 here-in-before but of size 35 Sq mm 3.5 core.

250

-

-

... More
All as per srl item No 11 here-in-before but of size 50 Sq mm 3.5 core.

250

-

-

... More
All as per srl item No 11 here-in-before but of size 70 Sqmm 3.5 core

250

-

-

... More
All as per srl item No 11 here-in-before but of size 95 Sqmm 3.5 core

200

-

-

... More
All as per srl item No 11 here-in-before but of size 120 Sqmm 3.5 core

220

-

-

... More
All as per srl item No 11 here-in-before but of size 185 Sqmm 3.5 core

200

-

-

... More
All as per srl item No 11 here-in-before but of size 240 Sqmm 3.5 core

200

-

-

... More
All as per srl item No 11 here-in-before but of size 300 Sqmm 3.5 core

50

-

-

... More
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for size 25 to 50 Sqmm x 3.5 core/ 4 core.

60

-

-

... More
All as per item No 22 but size 70 to 150 Sqmm x 3.5 core

50

-

-

... More
All as per item No 22 but size 185 to 240 Sqmm x 3.5 core

40

-

-

... More
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) of size 95 sqmm x 3 core with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, laid in trenches fixed to pole, including jointing & testing complete all as specified. Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.

45

-

-

... More
All as per item No 25 above but size 120 sqmm 3 core.

180

-

-

... More
All as per item No 25 above but size 185 sqmm 3 core

280

-

-

... More
All as per item No 25 above but size 240 sqmm 3 core

330

-

-

... More
All as per item No 25 above but size 300 sqmm 3 core

15

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 sqmm 3 core

14

-

-

... More
All as per item No 30 but size 150 Sqmm to 185 Sqmm, 3 core.

18

-

-

... More
All as per item No 30 but size 240 Sqmm to 300 Sqmm 3 core

14

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm 3 core.

17

-

-

... More
All as per item No 33 but size 150 Sqmm to 185 Sqmm, 3 core.

16

-

-

... More
All as per item No 33 but size 240 Sqmm to 300 Sqmm 3 core

16

-

-

... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm 3 core.

20

-

-

... More
All as per item No 36 above but size 150 Sqmm to 185 Sqmm, 3 core.

30

-

-

... More
All as per item No 36 above but size 240 Sqmm to 300 Sqmm 3 core

21

-

-

... More
Supply, laying, testing and commissioning in replacement of LT underground cables, 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed of Cables sizes 400 Sqmm single core

140

-

-

... More
All as per item Sl No 39 above but of size 630 sqmm single core

150

-

-

... More
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.

800

-

-

... More
Material and labour for disconnecting faulty/burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals with suitable size of thimbles for 25 Sqmm 3.5/4 core to 70 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.

55

-

-

... More
All as per item 42 above but for LT cable of size 95 Sqmm 3.5 core to 400 Sqmm 3.5 core.

45

-

-

... More
Boring of hole under road/pavement/hard standing or any other situation by mannual and making good both ends all specified and directed.

70

-

-

... More
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size 100 mm dia

35

-

-

... More
All as per item No 45 above but of size 80 mm dia

35

-

-

... More
All as per item No 45 above but of size 50 mm dia

30

-

-

... More
M&L for Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.

3

-

-

... More
M&L for cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) 150mm thick complete all as specified and as directed.

9

-

-

... More
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable of size 16 Sqmm flat complete all as specified ad directed.

600

-

-

... More
All as per Sr item No 50 above but of size 10 Sqmm.

450

-

-

... More
All as per Sr item No 50 above but of size 6 Sqmm.

350

-

-

... More
All as per Sr item No 50 above but of size 4 Sqmm.

400

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.6 mpa working pressure.

80

-

-

... More
All as per Sr item No 54 above but of size HDPE pipe of 200 mm dia

30

-

-

... More
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.

15

-

-

... More
Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006

10

-

-

... More
Material and labour Rubber Mat 2mtrx1 mtr Length, 19 mm thick, 1.1 kV Grade

8

-

-

... More
Disconnecting faulty 33 KV HT cables of different sizes from both ends i.e from tower/panel/yard, testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 33 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.

12

-

-

... More
Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conducators, 33 KV (E) grade, of size 400 sq mm, 3 core, laid in trenches complete all as specifed & directed in replacement of underground cable. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.

60

-

-

... More
Supply and fix cable jointing kit for 33 KV (Earthed ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 400 sqmm.

12

-

-

... More
Supply and fix cable jointing kit for 33 KV (Earthed ) grade cable for straight though heat shrink type joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 400 sqmm.

15

-

-

... More
Meterial and labour for emergency maintenance work of 33 KV overhead line during breakdown by deploying skilled labourer and electricians at faulty site having Gang of minimum 6 persons and tansportation including hydraulic machine and other tools and plant reqired a site for fault rectification. Note:- Contrator of his rep shall come to the site of breakdown within one hour of notification of breakdown. In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contactor and will be deduct from his dues.

18

-

-

... More
All as per Item No.63 here-in before above but Gang of minimum 3 persons except hydraulic machine.

25

-

-

... More
Supplying and Fixing in replacement, PG clamps aluminium cast alloy suitable for existing ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard/33 KV towers with GI nuts, boits etc complete all as specified and directed.

10

-

-

... More
S&F in replacement lsolators clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed.

10

-

-

... More
Supplying and Fixing in replascement, T-connector/ clamps, aluminium cast alloy suitable for existing ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specifed and directed.

10

-

-

... More
S&F in replacement CT clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all specified and directed

7

-

-

... More
S&F in replacement PT clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with Ginuts bolts complete all as specified and directed

7

-

-

... More
S&F in replacement dead end clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf of 33 KV towers with Ginuts bolts complete all as specified and directed

7

-

-

... More
S&F in replacement 33 circuit breaker clamp aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed

5

-

-

... More
Supplying and Fixing in replacement, Post insulator with hardware fittings, 33 KV Grade, for isolator complete all as specified and directed.

8

-

-

... More
Supplying and fixing in replacement, Disc insulators with hardware fittings, 33 KV Grade for 33 KV yard complete all as specified and directed.

15

-

-

... More
S&F in replacement of pin insulator with hardware fittings 33 KV grade complete all as specified and directed

4

-

-

... More
M&L for replacement of aluminium jumper made of ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf conductor of 33 KV towers/33 KV yard

15

-

-

... More
Material and labour for surface dressing n exc 15cm deep of soft loose soil of 33 KV towers structrue area complete all as specified as directed

550

-

-

... More
M&L in replacement of damage single/ double/triple tension disc insulators and hardware fitting and fixing in position including tighetning of bolts & nuts, complete after dismentling and lowering of damage conductor/disc insulator by taking tension of conductor on a separate arragement including opening & provinding of jumpers of 33 KV tension towers

7

-

-

... More
S&F in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 33 KV, 25 x 20 cm size including taking down old one complete all as specified and directed.

35

-

-

... More
M&L for stretching/ tightning of loose ACSR conductor including fixing of conductor accessories such as clamp etc as per site condition of Zebra/ Dog/Goat/Panther/Wolf conductor of 33 KV lines Note : Length of indl conductor shall be measured.

4.5

-

-

... More
M & L Jointing of ACSR conductor of any type with mid span joint through compression joint machine of 33 KV over head lines.

2

-

-

... More
Trimming and cutting of tree branches (not more than 25mm girth) coming across 33 KV HT over head line clearing the line around 2m single/both sides and disposal of branches from site exeeding 50m and not exceeding 250m from site complete all as directed by Engr-in-Charge. Note :- (i) Length of span is approx 200 to 225 RM. (ii) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/ renewal by the contractor from his own resources and nothing extra is admissible. (iii) All safety to labourer must be adhered by the contractor during trimming and cutting of tree branches.

25

-

-

... More
Supplying and fixing, Stretching, Securing, Connecting & testing of Aluminium Conductor Steel Reinforced (ACSR) of size Zebra/Dog/Goat/Panther/Wolf/mink for 33 KV over head lines/33 KV yard / earth for tower to tower complete including taking out old unserviceable conductor complete all as directed and specified by Engr In Charge.

2.8

-

-

... More
Testing out faulty underground 33 KV HT cable of 400 Sqmm by excavatioin and removing RCC cable covers and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new RCC cable cover as required. Note: (a) 33 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.

80

-

-

... More
M&L for Bore earthing 150mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 115mm C/C on both side of the pipe including lowering in bore well upto the depth of 49mtr and one mtr above the ground level. The pipe electrode should be filled around commericial salt charcoal dust, copper suphate and magnesium phosphate of 30cm layer each upto the full length of pipe. The borewell should have 12mtr of length 150mm dia MS pipe for protection of borewell. Welding of GI Strip 50mmx6mm on earth electrode GI Pipe 50mm dia upto 10mtr below ground level and 15 mtr from the bore well to test point gun metal and PCC foundation surrounding the borewell 60cmx60cm30cm all as directed by Engr-in-charge. GI strip more than 25mtr will be measured and paid separately. Note:- Cost of gun metal test point deemed to be included in the quoted rate.

2

-

-

... More
Supply , installation, testing and commissioning in replacement of air bake off load line isolator switch rotating type manually gear drive mechanism operated highest system voltage 36 KV rated current 1250 Amps triple pole with earthing device each pole consist of insulating pedestals 03 Nos on galvanized steel base as per BSS /IS incuding rotating blade of HDE copper and fixed contacts of same material , spring loaded arcing horns of adequate section to brake magnetizing current of transformer as directed with adequate 50mm dia GI operating pipe for operation from ground level and operating handle complete with both off and on positions complete all as specified and directed.

1

-

-

... More
All as per item No 85 above but bus isolator without earthing device

1

-

-

... More
S&F cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enemel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm for cable route indicator deemed to be included in the item.

10

-

-

... More
Material and labour in replacement Retro Reflective installation sign boards of size 5 feet x 4 feet fabricated out of 16 gauge MS sheet ,framed with stainless steel heavy duty pipe of size 50 mm bore duly welded/riveted with MS square pipe of size 25 mm x 25 mm at height 2.00 meter above ground level on stainless steel heavy duty pipe of size 50 mm bore embaded 60 CM in PCC 1:2:4 type B 1 block of size 45cm x 45cm x 60cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter i.e. details of Transformer, location, Sl No, SM No etc. will be in English language on both sides with reflective adhesive painter tapes all as directed and specified by Engineer -in-charge.

2

-

-

... More
Material and labour for replacement of HT cable PVC clamp with nut, blot and washer suitable for HT cable 11 KV 1000 sqmm single core , fixed with M S Chanel by making hole if required all as directed and specified by Engr In Charge.

25

-

-

... More
All as per item No 89 above but HT cable of size 400 sqmm 3 core ,33 KV.

4

-

-

... More
Material and labour for Schematic diagram network of Shekhawati Grid as follows:- (a) The diagram board should be not less than 6' x 4' x 6" (b) The structure should be made of framed by angle iron 25 mm x 25 mm x 1.4mm (c) The top sheet should be white acrelic sheet. (d) 04 x 20 watt LED tube light fitted inside the diagram alongwith complete wiring with controlling switch. (d) It should be hanged on the wall by drilling and fixing as directed. (e) Min 5 mtr PVC sheathed wire 1.5 sqmm 3 core .

1

-

-

... More
Material and labour for repainting of HT 11 KV VCB panel consisting of not less than 25 Nos VCB/Bus Coupler/Bus trunk of appx size 4-6 sqmm with 2 coats of super enamel paint over a coat of red-oxide with spraygun allas specified and directed at Shekhawati Grid.

1

-

-

... More
Material and labour for repainting of 33 KV panel consisting of not less than 7 Nos, Bty Charger panel-2 Nos of appx size 4-6 sqmm with 2 coats of super enamel paint over a coat of red-oxide with spraygun allas specified and directed at Shekhawati Grid.

1

-

-

... More
M&L for painting with two coats of superior aluminium paint including necessary preparation of steel surfaces of steel fencing by brushing/cleaning complete steel structure/wire mesh/frame/ gate not more than 3600 Sqmm area complete all as specified and directed.

1

-

-

... More
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.