Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 85,340Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686619_1Tender No
GE(U)/PM/D-40/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material & Labour for dismantling of old/unserviceable Out Doors of package type AC Plant Unit 11TR after disconnecting of all electrical connections, refrigerent gas pipe lines, dismantling rusted MS base frame & bricks column/PCC foundation and store refrigerent gas from AC package unit to cylinder , S & F in repair/ replacement Out Doors of pacakge type AC Plant unit of cap 11TR , suitable for Voltas, Model No-DPUA SC110- 02 Nos, Each Out Door having condenser coil and Condenser fan motor cap.- 375W(minimum), necessary accessories with complete wiring and re-connection of gas pipe line and MS base frame & bricks column/PCC foundation complete all as specified and directed.
2
-
-
... More
Supply & fixing in repair/ replacement control panel of pacakge type AC Plant unit of cap 30 TR , suitable for Voltas including contactors, relays, timer, CTs and other necessary accessories with complete wiring in existing unit complete all as specified and directed.
3
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of cross sectional area 185 Sqmm, 3 ½ core with galvanized steel strip or wire including taking down old unserviceable one compete all as specified and as directed.
95
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 150 Sqmm,3.5 core.
80
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 95 Sqmm,3.5 core.
80
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 35 Sqmm,4 core.
85
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 25 Sqmm, 4 core.
65
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 16 Sqmm, 4 core.
160
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 10 Sqmm, 4 core.
250
-
-
... More
`-ditto- all as per item No. 6 above but cross sectional area 6 Sqmm, 4 core.
290
-
-
... More
Supply and fixing repair/replacement cable tray of size 150 x 50 mm and thickness 3.00 mm compete all as specified and as directed. (Make as per sample).
80
-
-
... More
ditto all as per item no 14 but size 300 X 50 mm
45
-
-
... More
Material & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15cm thick including testing on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.)
18
-
-
... More
Supply & fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drewn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required 32x6 mm galvanised iron strip including taking down old unserviceable one complete all as specified & as directed.
160
-
-
... More
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire, including taking down old unserviceable one of any type and any size ( including wooden batten, PVC conduit or casing caping), complete all as specified and as directed.
220
-
-
... More
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire, including taking down old unserviceable one of any type and any size ( including wooden batten, PVC conduit or casing caping), complete all as specified and as directed. Note for item No. 18 & 19 :- (i) Two runs of cable with one run earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing caping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
250
-
-
... More
Material & Labour for dismantling of old/unserviceable Out Door of package type AC Plant Unit 7.5 TR after disconnecting of all electrical connections, refrigerent gas pipe lines, dismantling rusted MS base frame & bricks column/PCC foundation and store refrigerent gas from AC package unit to cylinder , S & F in repair/ replacement Out Door of pacakge type AC Plant unit of cap 7.5 TR , suitbale for Voltas, Model No. DCU SH75- 01 Nos, Each Out Door having condenser coil and Condenser fan motor cap.- 375W(minimum), necessary accessories with complete wiring and re-connection of gas pipe line and MS base frame & bricks column/PCC foundation complete all as specified and directed.
2
-
-
... More
Supply and fixing in repair/replacement fully automatic Star Delta Starter with suitable rating relays for motors of 10 HP Capacity suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire & brass terminals of 6 way compete all as specified and as directed.
3
-
-
... More
Supply and fixing in repair/replacement DOL starters for motors of 7.5 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire compete all as specified and as directed.
6
-
-
... More
Supply and fixing in repair/replacement DOL starters for motors of 3/5 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire compete all as specified and as directed.
7
-
-
... More
Supply and fixing in repair/replacement Immersion heaters of cap 5/6 KW 230/440 volts as required compete all as specified and as directed.
5
-
-
... More
Supply and fixing in repair/replacement Immersion heaters of cap 25 KW 230/440 volts as required compete all as specified and as directed.
5
-
-
... More
Supply and fixing in repairs strip heater heaters of cap 2/3 KW 230/440 volts as required compete all as specified and as directed.
30
-
-
... More
Supplying and laying in replacement synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, compete all as specified and as directed.
10
-
-
... More
Supply and fixing in replacement moulded case circuit breakers(MCCB) 320 Amps, 4 Pole, 36 KA, thermal magnetic with rotary handle and spreader compete all as specified and as directed.
1
-
-
... More
Supply and fixing in replacement moulded case circuit breakers(MCCB) 250 Amps, adjustable type, 3 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed.
1
-
-
... More
Supply and fixing in replacement moulded case circuit breakers(MCCB) 200 Amps, adjustable type, 3 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed.
1
-
-
... More
Supply and fixing in replacement moulded case circuit breakers(MCCB) 160 Amps, adjustable type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement moulded case circuit breakers(MCCB) 125 Amps, adjustable type, 4 Pole, 36 kA, thermal magnetic with rotary handle and spreader compete all as specified and as directed.
2
-
-
... More
Supply and fixing in replacement moulded case circuit breakers(MCCB) 100 Amps, adjustable type, 4 Pole,36 kA thermal magnetic with rotary handle and spreader compete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement miniature circuit breaker (MCB) 63 Amps, 3 Pole, 10 KA compete all as specified and as directed.
10
-
-
... More
Supply and fixing in replacement miniature circuit breaker (MCB) 32 Amps, 3 Pole, 10 KA compete all as specified and as directed.
8
-
-
... More
Supply and fixing in replacement power contactor, 110 Amps triple pole (TP), AC 3 duty, with add on block (2 NO+2NC), compete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement power contactor, 95 Amps triple pole (TP), AC 3 duty, with add on block (2 NO+2NC), compete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement power contactor, 80 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement power contactor, 70 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
3
-
-
... More
Supply and fixing in replacement power contactor, 50 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement power contactor, 32 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
2
-
-
... More
Supply and fixing in replacement power contactor, 25 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
10
-
-
... More
Supply and fixing in replacement power contactor, 18 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
25
-
-
... More
Supply and fixing in replacement power contactor, 12 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement power contactor, 9 Amps triple pole (TP), AC 3 duty compete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement Auxillary contactor (2NO + 2NC), suitable for 9-80 Amps power contactors, compete all as specified and as directed.
35
-
-
... More
Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 4.5-7.5 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.
3
-
-
... More
Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 9-15 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.
14
-
-
... More
Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 14-23 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.
13
-
-
... More
Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 20-33 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.
1
-
-
... More
Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 30-50 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.
3
-
-
... More
Supply & Fixing in repair/replacement three phase Over load thermal relay direct mounting type, relay range 45-75 Amps, including necessary wiring, thimbles, etc complete all as specified and as directed.
4
-
-
... More
Supply & Fixing PVC insulated single core copper conductor cable of size 16 sqmm for connections in LT Panels, complete all as specified and as directed.
60
-
-
... More
ditto all as per item no. 53 but size 10 Sqmm
150
-
-
... More
ditto all as per item no. 53 but size 6 Sqmm
260
-
-
... More
Supply & Fixing solid state single phasing preventer type VSP2/ VSP3 complete all as specified and as directed.
8
-
-
... More
Supply & Fixing aluminium lugs for cable of cross sectional area 6 Sqmm to 35 Sqmm complete all as specified and as directed.
95
-
-
... More
Supply & Fixing aluminium lugs for cable of cross sectional area 50 Sqmm to 185 Sqmm complete all as specified and as directed.
40
-
-
... More
Supply & Fixing copper lugs for cable of cross sectional area 6 Sqmm to 35 Sqmm complete all as specified and as directed.
30
-
-
... More
Supply & fixing star/delta timer range 0-60 seconds, suitable for LT panels, complete all as specified and as directed.
5
-
-
... More
Supply & fixing in replacement of Digital type Multifunction meter Flush mounted 3 phase for measuring parameters (V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh), with suitable rating current transformers with built in selector switches suitable for mounting on LT panel, compete all as specified and as directed.
8
-
-
... More
Supply & fixing in replacement of Digital type Ammeter Flush mounted 3 phase, with suitable rating current transformers suitable for measuring range minimum (0-200) Amps with selector switch suitable for mounting on LT panel, compete all as specified and as directed.
8
-
-
... More
Supply & fixing in replacement Digital type Voltmeter Flush mounted 3 phase, with suitable rating current transformers suitable for measuring range minimum (0-600) Volts with selector switch suitable for mounting on LT panel, compete all as specified and directed.
6
-
-
... More
Supply & fixing in replacement of Analog type Ammeter Flush mounted 3 phase, with suitable rating current transformers suitable for measuring range minimum (0-60) Amps with selector switch suitable for mounting on LT panel, compete all as specified and as directed.
15
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv outdoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type LT panel board of suitable size confirming to IS:5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including.
(i) MCCB, 100A Capacity, 4 Pole, 16 KA, 415 volts fixed type with extended terminals - 1Nos
(ii) Solid copper bus bar 200Amp for 3 phase and same size for neutral.
(iii) Provn of DOL starter with TP power contactors ,No/Nc Aux contact , O/L relay , preventer etc suitable for three phase ducting cooler motor of capacity 3HP -03 Nos. (iv) Auto manual selector switch - 06 No. (v) 32A TPN MCB with complete accessories for exhaust fan motor -03Nos
(vi) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio.-01 Nos
1
-
-
... More
(vii) Start/Stop push buttons - 06 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 12 Nos, Control fuse with link- -03 Nos, (viii) Control wiring shall be carried out with 2.5 sqmm copper wire. (ix) Digital Ammeter(0-60A)-03 Nos
Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv indoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, indoor type LT panel board of suitable size (minimum size 2000mm X 1500mm X 450mm) confirming to IS:5039 with IP-54 protection, made out of 2 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including.
(i) Main MCCB, 400A Capacity, 4 Pole, 36 KA, 415 volts fixed type with extended terminals - 1Nos (ii) MCCB, 160A Capacity, 4 Pole, 36KA, 415Volts fixed type with extended terminals- 04Nos (iii) MCCB, 100A Capacity, 4 Pole, 35/36KA, 415Volts fixed type with extended terminals- 01Nos (iv) Solid copper bus bar 400Amp for 3 phase and same size for neutral.
(v) Provn of fully automatic star delta starter with suitable TP power contactors ,No/Nc Aux contact , O/L relay, preventer, timers, mcb spn etc suitable for three phase centrifugal pump motor of capacity 40HP -04 No (vi) Provn of fully automatic star delta starter with suitable TP power contactors ,No/Nc Aux contact , O/L relay , preventer, timers, mcb spn etc suitable for three phase cooling tower motor of capacity 20HP -01 Nos.
(vii) Auto manual selector switch - 10 No. (viii) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio.-01 Nos (ix) Start/Stop push buttons - 10 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 10 Nos, Control fuse with link- -03 Nos,
1
-
-
... More
(x) Control wiring shall be carried out with 2.5 sqmm copper wire. (xi) Digital Ammeter(0-200A)-05Nos
Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv indoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, indoor type LT panel board of suitable size (minimum size 2000mm X 2000mm X 450mm) confirming to IS:5039 with IP-54 protection, made out of 2 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including.
(i) Main MCCB, 250A Capacity, 4 Pole, 50 KA, 415 volts fixed type with extended terminals - 1Nos (ii) MCCB, 160A Capacity, 4 Pole, 36KA, 415Volts fixed type with extended terminals for compressor chiller unit- 02Nos (iii) MCCB, 100A Capacity, 4 Pole, 35/36KA, 415Volts fixed type with extended terminals suitable for hot water generator of cap 30kw - 02Nos. (iv) Solid copper bus bar 400Amp for 3 phase and same size for neutral. (v) Provn of fully automatic star delta starter with suitable TP power contactors ,No/Nc Aux contact , O/L relay , preventer, timers, 63A MCB TPN, MCB spn etc suitable for three phase AHU Blower motor of cap 12.5HP -01 Nos. (vi) Provn of DOL starter with suitable TP power contactor ,No/Nc Aux contact , O/L relay , preventer, 63 MCB TPN, mcb spn etc suitable for three phase chiller/condensor mono block pump motor of capacity 5HP -04 Nos. (vii) Provn of DOL starter with suitable TP power contactor ,No/Nc Aux contact , O/L relay , preventer, 32A MCB TPN, mcb spn etc suitable for three phase AHU/CT Fan or Hot Water motor of capacity 3HP -05 Nos.
(viii) Auto manual selector switch - 20 No.
1
-
-
... More
(ix) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio.-01 Nos (x) Start/Stop push buttons - 20 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 28 Nos, Control fuse with link- -03 Nos, (xi) Complete Control wiring shall be carried out with 2.5 sqmm copper wire. (xii) Digital Ammeter(0-200A)-10Nos Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv indoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, indoor type LT panel board of suitable size (minimum size 2000mm X 2000mm X 600mm) confirming to IS:5039 with IP-54 protection, made out of 2 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including.
(i) Main MCCB, 250A Capacity, 4 Pole, 50 KA, 415 volts fixed type with extended terminals - 1Nos (ii) MCCB, 160A Capacity, 4 Pole, 36KA, 415Volts fixed type with extended terminals for compressor chiller unit- 02Nos (iii) MCCB, 100A Capacity, 4 Pole, 35/36KA, 415Volts fixed type with extended terminals suitable for hot water generator of cap 30kw - 02Nos (iv) Solid copper bus bar 400Amp for 3 phase and same size for neutral.
(v) Provn of DOL starter with suitable TP power contactor ,No/Nc Aux contact , O/L relay , preventer, mcb 63A, MCB spn etc suitable for three phase chiller/condensor mono block pump motor of capacity 5HP -04 No (vi) Provn of DOL starter with suitable TP power contactor ,No/Nc Aux contact , O/L relay , preventer, MCB tpn 32A, MCB spn etc suitable for three phase AHU/CT Fan or Hot Water motor of capacity 3HP -10 Nos.
(vii) Auto manual selector switch - 28 Nos. (viii) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio.-01 Nos
1
-
-
... More
(ix) Start/Stop push buttons - 20 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 28 Nos, Control fuse with link- -03 Nos, (x) Complete Control wiring shall be carried out with 2.5 sqmm copper wire. (xi) Digital Ammeter(0-200A)-10Nos Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv indoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, indoor type LT panel board of suitable size confirming to IS:5039 with IP-54 protection, made out of 2 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including.
(i) MCCB, 100A Capacity, 4 Pole, 36 KA, 415 volts fixed type with extended terminals - 1Nos
(ii) Solid copper bus bar 200Amp for 3 phase and same size for neutral.
(iii) Provn of DOL starter with TP power contactors ,No/Nc Aux contact , O/L relay , preventer, 32A MCB TPN, MCB SPN etc suitable for three phase 7.5TR compressor and fan motor(375W) ( Total load approx. 7. 5HP) -02 Nos. (iv) Provn of DOL starter with TP power contactors ,No/Nc Aux contact , O/L relay , preventer 63A MCB TPN, MCB SPN etc suitable for three phase AHU motor of cap- 5HP -01 Nos. (v) Suitable TPN MCB with complete accessories for 10KW DUCT heater bank-02Nos (vi) Auto manual selector switch - 06 No. (vii) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio.-01 Nos (viii) Start/Stop push buttons - 06 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 10 Nos, Control fuse with link- -03 Nos, (ix) Control wiring shall be carried out with 2.5 sqmm copper wire. (x) Digital Ammeter(0-60A)-03 Nos
1
-
-
... More
Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
Supply & fixing in replacement Analog type Voltmeter Flush mounted 3 phase, with suitable rating current transformers suitable for measuring range minimum (0-500) Volts with selector switch suitable for mounting on LT panel, compete all as specified and directed
13
-
-
... More
Excavation in trenches, not exceeding 1.5 m wide & not exceeding 1.5 mtr in depth for laying of GI/CI Pipes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
90
-
-
... More
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
44.37
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
45.63
-
-
... More
Material & Labour for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note:- For measurement purpose punned thickness of sand shall only be considered.
32.4
-
-
... More
Supply and Laying old size brick size 230 mm X 113 mm X 75 mm as in protection to cable complete all as specified and directed.
3540
-
-
... More
Supply and fixing in repair/ replacement control panel of central type AC Plant unit of cap 110TR , suitable for Bluestar, Model- No LCWX2-220DEF including contactors, relays, timer, Cts and other necessary accessories with complete wiring in existing unit complete all as specified and directed.
2
-
-
... More
Supply and fixing in repair/ replacement digital display of central type AC Plant unit of cap 220TR , suitable for Bluestar, Model- No LCWX2-220DEF having auto, semi auto and manual mode options for setting of parameters having diagonostic capabilities, microcomputer motor protection device (μ - MPD) and microcomputer voltage protection device (μ - VPD), pressure and temperature transducers for safety, Built-in time delay, Auto distribution of load, BMS compatibility, in-built, anti-freeze protection system, and Auto-restart feature, along with complete internal wiring with connecting accessories like cable, wires, terminals etc., all as specified and as directed.including complete necessary accessories with complete wiring in existing unit complete all as specified and directed.
1
-
-
... More
Material and Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed.
420
-
-
... More
Supply and fixing in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement of basic all purpose surface and wall mounted LED batten 20 Watt with polycarbonate housing & intigrated electronic driver with all necessary fixing accessories complete all as specified and as directed.
25
-
-
... More
Supply and fixing in replacement exhaust fan 450 mm sweep SP 230V , 50Hz,1400 RPM heavy duty MS body including louvre and making hole on wall and grouting the same including taking down unserviceable one complete all as specified and as directed.
3
-
-
... More
Supply, installation, testing and commissioning in replacement of scroll compressor of cap 5.5 TR,Model No-HLM072T4LC6 of make danfoss connecting up suction and discharge copper pipe with gas welding, including charging of refrigerant gas, pressure testing by nitrogen gas, leakage rectification, complete all as specified and directed.
1
-
-
... More
Supply and topping up of refrigerant Gas R-22/407/410/134A, complete all as specified and as directed.
115
-
-
... More
Supply, installation, testing and commissioning in replacement of scroll compressor of cap 12.5TR,Model No-SZ185S4RC of make danfoss connecting up suction and discharge copper pipe with gas welding, including charging of refrigerant gas, pressure testing by nitrogen gas, leakage rectification, complete all as specified and directed.
1
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv wall mounted indoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, indoor type LT panel board of suitable size confirming to IS:5039 with IP-54 protection, made out of 2 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including. (i) MCCB, 160A Capacity, 4 Pole, 25 KA, 415 volts fixed type with extended terminals - 1Nos
(ii) Solid copper bus bar 200Amp for 3 phase and same size for neutral.
(iii) Provn of DOL starter with TP power contactors ,No/Nc Aux contact , O/L relay , preventer etc suitable for 13000 CFM AHU motor of capacity 7.5HP -01 Nos. (iv) Auto manual selector switch - 03 No. (v) 63A TPN MCB with complete accessories for strip heater of minimum 3 kw -10Nos (vi) Digital voltmeter0-500V).-01 Nos (vii) Start/Stop push buttons - 06 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 12 Nos, Control fuse with link- -03 Nos, (viii) Control wiring shall be carried out with 2.5 sqmm copper wire. (ix) Digital Ammeter(0-60A)-03 Nos
1
-
-
... More
Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
... More
Material & Labour for disconnecting all electrical LT cables and taking down the old unsv wall mounted indoor panel of any size and model including all accessories from panel and Supply and installation, testing, commissioning, factory made, CPRI approved, indoor type LT panel board of suitable size confirming to IS:5039 with IP-54 protection, made out of 2 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including CTs , MS angle section 45 x 45 x 6 mm frame with both side openable, Dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated and fondation, cement work etc complete all as specified and directed & Consisting of the following equipments including. (i) MCCB, 160A Capacity, 4 Pole, 25 KA, 415 volts fixed type with extended terminals - 1Nos
(ii) Solid copper bus bar 200Amp for 3 phase and same size for neutral.
(iii) Provn of star delta starter with TP power contactors ,No/Nc Aux contact , O/L relay , preventer etc suitable for 17000 CFM AHU motor of capacity 10HP -01 Nos. (iv) Auto manual selector switch - 03 No. (v) 63A TPN MCB with complete accessories for strip heater of minimum 3 kw -10Nos (vi) Digital voltmeter0-500V).-01 Nos (vii) Start/Stop push buttons - 06 Nos, Phase indication -(RYB) - 03Nos & Motor ON/ OFF/Trip indicating lamps LED type - 12 Nos, Control fuse with link- -03 Nos, (viii) Control wiring shall be carried out with 2.5 sqmm copper wire. (ix) Digital Ammeter(0-60A)-03 Nos
1
-
-
... More
Note :- The contractor shall get the drawings approved by the accepting officer before placing the orders.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%