Indian Oil Corporation Limited Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Indian Oil Corporation Limited - IOCL Tender

Works
Eprocure
Opening Date14 May 2020
Closing Date22 Jun 2020
Tender Amount₹ 2,19,21,159 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pressure Transmitters with Cable glands Range max (0 - 100 kg/cm2); Smart type; accuracy 0.075% or better Installation: 2" Pipe Mo unted

9

-

-

... More
Differential Pressure Transmitter with manifold valves and Cable Glands.Range max (0 to 3 kg/cm2).Smart type; accuracy 0.1% or bette r

4

-

-

... More
Temperature Transmitter with duplex RTD, Thermowell & Cable glands, Range max (0 to 100 0C ) Smart type; accuracy 0.1% or better In stallation: Transmitter 2" pipe mounted; RTD in thermowell on process pipe above ground installation.

2

-

-

... More
Temperature Transmitter with surface mounted duplex RTD, Weld pad and dual sensors & Cable glands, Range max (0 to 100 0C); Smart ty pe; accuracy 0.1% or better Installation: Transmitter 2" pipe mounted ; RTD in weldpad welded to process pipe surface for below gro und installation.

2

-

-

... More
Pressure switches with junction box & cable glands suitable for low pressure side, set point 1 Kg/cm2 to 10 Kg/cm2. Proof Pressure: 200 Kg/cm2.

4

-

-

... More
Pressure switches with junction box & cable glands suitable for High pressure side, set point 3 Kg/cm2 to 25 Kg/cm2. Proof Pressure: 200 Kg/cm2.

7

-

-

... More
Field Configurator for Pressure & Temperature transmitter with Hart protocol

1

-

-

... More
4 1/2 Digit DMM (True RMS)

1

-

-

... More
Multifunction Calibrator with rechargable battery, charger, carry case, etc

1

-

-

... More
Pressure Calibrator 0 - 20 bar (Portable), accuracy - 0.1%

1

-

-

... More
a) For I/Os upto 500 (of any type)

1

-

-

... More
For DI

15

-

-

... More
For AI

30

-

-

... More
For RTD

15

-

-

... More
For A/O

4

-

-

... More
For Pulse

6

-

-

... More
For AI signals

30

-

-

... More
For AO signals

4

-

-

... More
For RS 232/485 signals

10

-

-

... More
For LAN application

4

-

-

... More
3 Phase 4 wire (415 V) TT applications

2

-

-

... More
1 Phase 2 wire (230 V) applications

2

-

-

... More
Supply Items - Bijwasan ATF control Syst

-

-

-

... More
MCS cum SCC / SCC operator workstations / terminals

4

-

-

... More
SIC Terminal / Electrical Maint. / T&I Terminal / Alarm Management Terminal / Network Management Terminal

1

-

-

... More
Industrial Grade Programming Terminal (Laptop) for BV-RTUs

1

-

-

... More
GPS Time Server for time synchronization of all MCS / SCC computers and control system computers as per the tender specifications

1

-

-

... More
Firewall as per tender specifications and datasheets

2

-

-

... More
24 port Industrial Grade dual Ethernet Switches for redundant 10/100/1000 MBPS LAN with networking software, cables & connectors etc . complete inall respects as per tender specifications. (1 set comprises of 2 switches)

2

-

-

... More
WAN Router (8 port) system for MCS / SCC connectivity with software, cables, connectors etc complete in all respects as per tender s pecifications

2

-

-

... More
Industrial media converters / Line Interface units (LIU) compatible to Owner supplied single mode 24 fibre OFC & supply of patch cor ds, pig tails, connectors etc. for extension of Tank Farm Management System / Marketing Terminal Automation Software / SIC Terminal / any other terminal (1 set comprises 2 converters)

3

-

-

... More
LaserJet Printer, c/w all interconnecting cables, cords, connectors etc., complete in all respects as per tender specs & datasheet

2

-

-

... More
Print Server for dual ethernet connection of printer

2

-

-

... More
Swivel chairs

3

-

-

... More
Table for SIC terminal

1

-

-

... More
Table for printers

2

-

-

... More
PLC programming / Ladder logic software etc. for the following: (a) Dual redundant PLC's (b) Programming/ Engineering Terminals

1

-

-

... More
Flow Computer complete with software for meter proving and tables as per API for petroleum products, turbine / mass flow meter input s, Density meter inputs etc as per the tender specifications & data sheet.

2

-

-

... More
5 KVA in (1+1) parallel redundant equal load sharing configuration excluding battery as per the tender specifications

1

-

-

... More
Sealed maintenance free 2V VRLA battery in dual string for 4 hrs backup considering aging, temperature & capacity factors complete w ith all interconnecting cables, glands, battery cables, battery stands, AC distribution boxes, connectors & lugs etc as per the tend er specifications for 5 KVA UPS.

1

-

-

... More
1 KVA UPS with 20 minutes battery back-up for SIC terminal / Electrical maintenance terminal

1

-

-

... More
PLC Processor Module

1

-

-

... More
PLC Processor power supply

1

-

-

... More
Rack power supply

2

-

-

... More
Digital input module

1

-

-

... More
Digital output module

1

-

-

... More
Analog input module

1

-

-

... More
Analog output module

1

-

-

... More
Serial Interface communication module

1

-

-

... More
Field interrogation power supply

1

-

-

... More
Set of fuses for line repair services

1

-

-

... More
PCB's, one of each type for 5 KVA UPS

1

-

-

... More
Supply Items - Bijwasan ATF control Syst

-

-

-

... More
2 loop, Addressable, Intelligent Fire Detection and Alarm Panel with FM200/ CO2 release facilities for automatic fire detection & a nnunciation of alarms for various types of detectors installed like multi sensor, heat detectors, response indicators, loop isolato rs, manual call points, hooters etc installed in plant area and various buildings as per tender specifications

1

-

-

... More
UV / IR Flame Detectors explosion proof & weather proof along with allmounting & other accessories as per the tender specifications.

3

-

-

... More
Intrinsically safe Rate of Rise Heat Detectors for hazardous areas alongwith all mounting & other accessories as per the tender spec ifications

3

-

-

... More
Multi sensor detectors along with all mounting & other accessories asper the tender specifications

7

-

-

... More
Monitor modules alongwith all mounting & other accessories for third party interface as per the tender specifications.

7

-

-

... More
Addressable Manual Call Point (for safe area) along with all mounting & other accessories as per the tender specifications.

2

-

-

... More
Addressable Beacons for safe area along with all mounting & other accessories & instructions sign as per the tender specifications.

2

-

-

... More
Addressable Hooters / Horn / Strobe (for safe area) along with all mounting & other accessories as per the tender specifications.

2

-

-

... More
2 Pair x 1.5 Sq. mm, unarmoured FRLS cable complaint to BS: 5308 as per the tender specifications for indoor applications to be laid through conduits.

100

-

-

... More
Weather proof junction boxes including supply of double compression cable glands, plugs for unused cable entries including WP certif icates as per the tender specifications for various detectors in buildings.

2

-

-

... More
Beacons (Explosion Proof & Weather Proof) for hazardous areasalong with all mounting & other accessories as per the tender specifica tions.

1

-

-

... More
Explosion Proof / Weather Proof Hooters (for hazardous area) along with all mounting & other accessories as per the tender specific ations.

1

-

-

... More
Response Indicators along with all mounting & other accessories as per the tender specifications.

2

-

-

... More
"Isolators for isolating of signalling loop in case of any fault alongwith all mounting & other accessories as per the tender specifications."

2

-

-

... More
FXO-FXS VOIP Box as per specifications

2

-

-

... More
Day-Night Colour IP PTZ Dome Camera, with 15X to 20X Optical Zoom, minimum 10X Digital Zoom along with IP 66 weatherproof housing wi th IR Illuminator, industrial grade power supply, camera interfacing junction box as applicable, lightning & surge protection and su itable mount , complete with cables, connectors, required interfaces etc. as per tender specifications

2

-

-

... More
Field mounted Explosionproof & Weatherproof IP65 Junction Box for Ex-proof Camera/field cameras with suitable cable glands, plugs, F iber termination patch panel, MCB, media convertor etc complete in all respects for installation of exproof camera/field camera. The junction shall be used for installation of network switch and optical accessories, power supply etc for CCTV system as applicable .

2

-

-

... More
Supply of 5 to 6 meter pole for mounting of CCTV as per technical specification of the tender.

2

-

-

... More
Test Power Supply 0 - 60 V, 10 A 600 Watts, 19" rack mount, sleek 1U type

1

-

-

... More
Micro processor based Temperature Calibrator; Range ambient to 300 deg C; accuracy 0.5%

1

-

-

... More
LED Display Unit (50" & above) System with interface complete with all inter connecting cables, cords, connectors, peripherals etc c omplete in all respects as per the tender specifications & datasheet.

1

-

-

... More
MMI Software of same make as the PLC (including one time license fee) etc as per the tender specification, for the following for run ning of the station in emergency situations like failure of SCADA computers:

1

-

-

... More
For T3 DAFFPL with total I/Os as per I/O table attached with tender (Max I/Os 250) For T3 DAFFPL with total I/Os as per I/O table at tached with tender (Max I/Os 250)

1

-

-

... More
2 section console desk for BIJWASAN Terminal 2 section console desk for BIJWASAN Terminal

1

-

-

... More
2 section console desk for T3 DAFFPL 2 section console desk for T3 DAFFPL

1

-

-

... More
T3 DAFFPL(1 set comprise of 2 Workstation) T3 DAFFPL(1 set comprise of 2 Workstation)

1

-

-

... More
Telephone Instrument as per tender specifications

4

-

-

... More
Services - Bijwasan ATF control Systems

-

-

-

... More
Erection, testing & commissioning of 2 Loop Fire Alarm & Detection System comprising of addressable Fire Alarm Panel, addressable de tectors of various types such as multisensor detectors, rate of rise heat detectors, manual call points, hooters, etc including FM20 0/ CO2 release system for control building consisting of Control room, Equipment room, MCC room, transformer room, VFD roomand other office /workshop rooms etc. and pumping sheds, piping area energizing & testing of the complete system with simulation and also de monstration of working of the complete system,commissioning of the complete system including the cost of all materials, labour, cons umables, equipments tools & tackles as per the specifications & instructions of Site Engineer / EIC.

1

-

-

... More
Installation of UV/IR Flame Detectors, terminating the cables at field and control panel end, connecting to earthing grid by supplyi ng and installing all the required materialssuch as supporting structure, cement concrete, painting, GI wire etc.(excluding supply o f the UV/IR Flame detector) complete in all respect as per specifications.

3

-

-

... More
Multi Sensor Detectors & isolators

7

-

-

... More
Rate of Rise Heat Detectors for safe area & hazardous area

3

-

-

... More
Manual Call Point (for safe area)

2

-

-

... More
Beacons / Hooters / Horn / Strobe (for safe area)

4

-

-

... More
Installation of Explosion Proof & Weather Proof Manual Call Point/ Hooters/ Beacons in Hazardous area, terminating the cables at fi eld and control panel end, connecting to earthing grid by supplying and installing all the required materialssuch as supporting stru cture, cement concrete, painting, GI wire etc.(excluding supply of the Manual Call Point/ Hooter/ Beacon) complete in all respect as per specifications.

2

-

-

... More
Installation of explosion proof / flame proof junction boxes for marshalling of control / signalling cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the require d materials such as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Junction Boxes) complete i n all respects as per specifications, approved drawings and direction of EIC / Site Engineerincluding all labour, tools, materials, glanding, ferruling etc.complete in all respects.

2

-

-

... More
Laying of unarmoured signal cable through GI pipe / wall / tray etc for interfacing of various type of detectors e.g. multi sensor, ROR, UV/ IR flame detector, response indicator, hooters, beacons etc

100

-

-

... More
Response Indicators & Monitor modules

9

-

-

... More
Supervison of erection, testing & commissioning of PLC based control system at attended stations including supervision for terminati on of control cables & erection of panels, looptesting, and commissiong of complete control systems along with support for interfaci ng with SCADA system and field instrumentation systems for operation of station facilities in remote & auto mode. This shall include development of control logics, database,HMI screens etc. for commisosing of the system complete as per drawings / specifications a nd acceptance of system by Owner. Supply of all labour, consumables, tools, services rendered etc. shall be in the contractors's sco pe.

1

-

-

... More
Installation and interfacing of FXO and providing support in extending subcribers through FXO

2

-

-

... More
Supervison of erection, testing & commissioning of PLC based control system at attended stations including supervision for terminati on of control cables & erection of panels, looptesting, and commissiong of complete control systems along with support for interfaci ng with SCADA system and field instrumentation systems for operation of station facilities in remote & auto mode. This shall include development of control logics, database,HMI screens etc. for commisosing of the system complete as per drawings / specifications a nd acceptance of system by Owner. Supply of all labour, consumables, tools, services rendered etc. shall be in the contractors's sco pe.

1

-

-

... More
Interfacing of the Tank Farm Management System / Refinery Tank Gauging System

2

-

-

... More
Foundation, laying and erection of 5 to 6 meter pole for installation of CCTV as per tender specifications including the cost of l abor, material, tools, tackles and all civil works complete in all respect.

1

-

-

... More
Erection, Installation, Testing and Commissioning of CCTV Cameras which includes Powering up, Network connection, interfacing with the OFC and Network switch in Control Room. Providing assistance in interfacing with existing system. Laying of power supply cable & OFC in Field shall be in owners scope. all items as per BOM of CCTV system to complete the work in all respect as per scope and technical specifictaions of the tender

1

-

-

... More
Services - Bijwasan ATF control Systems

-

-

-

... More
Training on supplied system (including PLC based control system, SCADA, PAS etc)

1

-

-

... More
Submission of As Built Documentation

2

-

-

... More
AMC - Bijwasan ATF control Systems

-

-

-

... More
AMC for 1st Year

1

-

-

... More
AMC for 2nd Year

1

-

-

... More
AMC for 3rd Year

1

-

-

... More
AMC for 4th Year

1

-

-

... More
AMC for 5th Year

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.