Delhi Urban Shelter Improvement Board Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Urban Shelter Improvement Board - DUSIB Tender
Eprocure
Opening Date28 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 4,72,718
Costs
EMD
₹ 9,500Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Construction And Management Of Night Shelters. (revenue)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DUSIB_264239_1Bid Award Id
ViewTender No
NIT NO.37/EE(E-3)/DUSIB/2024-25Tender Authority
Delhi Urban Shelter Improvement Board ViewPurchaser Address
-Website
http://http://delhishelterboard.in/main/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. (Add cost index @1.0633 on DSR 2018)
6
212
1272
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A (Add cost index @1.0633 on DSR 2018)
1
409
409
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (Add cost index @1.0633 on DSR 2018)
-
-
-
For 14 way, Double door SPN MCBDB
2
919
1838
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as required. (Add cost index @1.0633 on DSR 2018)
2
5644
11288
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. (Add cost index @1.0633 on DSR 2018)
300
39
11700
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (Add cost index @1.0633 on DSR 2018)
-
-
-
Upto 35 sq. mm
300
33
9900
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (Add cost index @1.0633 on DSR 2018)
-
-
-
Upto 35 sq. mm (clamped with 1mm thick saddle)
20
41
820
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (Add cost index @1.0633 on DSR 2018)
-
-
-
63 mm dia (OD-63 mm & ID-51 mm nominal)
186
222
41292
90 mm dia (OD-90 mm & ID-76 mm nominal)
100
265
26500
Supplying of 9 Mtr long Galvanised Octagonal pole Top dia - 70 mm, botto dia - 155mm sheet thikness - 3mm with ladder system of M x 16 x 300 mm & base plate - 260 x 260 x 16 mm. It should also include accessories for high mast i.e. foundation accessiries of 4 x M - 24 x 750 with anchor plate , ring / straight bracket galvanized lantern carriage arrangement suitable for 4/6 Nos. LED flood lights luminaries and lightning finial. Mast shaft shall be hot dip galvanized inside and outside and suitable for wind velocity as per IS 875 Part lll. The pole should have arrangement of mounting of 1/2 Nos of single pole MCB of 16amps as per specification attached. (MR)
1
38078
38078
Supplying, installation, testing and commisioning of 50 watt LED flood light with new generation energy saving and environment long life versatile powder coated die cast aluminium, IP 66, luminaire efficacy 100 lm/W, CCT 5700K, CRI 70, THD 10%, built-in surge protection 4 kV, External Surge Protection 10 kV, Power factor 0.95, IK07, the driver should be potted, capable to withstand 440V for 8 Hrs with high power LED light source with secondary lens complete etc. As required housing reflector and enclosed with toughened glass complete with all accessories.
16
5314
85024
Supplying and fixing of wall mounting internal prewired (FRLS) Street Light panel having CRCA sheet steel enclosure duly phosphatised and powder coated with IP 54 degree of protection conforms to IS/IEC 60947-4-1, comprising of MCB (SPN), Contactor, MCB (SP), programmable digital timer, earthing screw, Auto manual switch, inbuilt short circuit protection, exteded wide band coil, class H insulation, louvers on both sides etc. suitable for operation of High Mast/Street lights/Area light pole.
1
12950
12950
Supply of PVC insulated armored and PVC Sheathed (general pupose) multi core cable with standard aluminium conductor suitable for working voltage upto and including 1100 volts confirming to IS7098 as required 3 x 10 Sqmm.
300
132
39600
Fabricating , Supplying & Fixing of wiremesh protection frame work around SHM of minimum height 2Mtr above the ground level having three panels & one door Fabricated with 40x40x6 mm thickness angel iron Frame and Tee iron 40x40x6 mm thickness in centre of frame including providing and fixing wire mesh of section 75x25 mm of 8 swg and shall be fixed with 25x3 mm thickness MS flat in frame. i/c grouting of frame in ground with miminmum 4nos of footing of 1:2:4 CC. All the panels must be welded or fixed with suitable arrangement of nut bolts with each other and all frame work is to be painted with 2 or more coats of red oxide primer and 2 coats of synhetic enable paints.
36
2501
90036
Design, supply, fabrication and fixing of Signage Board using words made of acrylic cut out letters using LED and reflecting vinyl sheet as per the approved specification (a) Board shall be fabricated with 3 mm thick ACP sheets of Indobond or equivalent make. Power coated Aluminium sheet shall be fixed from the rear side of the entire board to make box section. (b) Powder coated aluminium clips and bracketed shall be used of minimum 3 mm thickness as per direction of Engineer in Charge (c) Wordsof other matter of the signage board shall be fixed using reflective vinyl cutout letters of MACTEC or equivalent make. (MR)
40
1026
41040
Supplying and fixing of SS Enclosure suitable for 3 Pole / 4 Pole MCCB rating upto 125A having generous space for cable termination in built neutral link IP 30 protection mounting holes for easy wall/flush mounting louvers for better heat dissipation i/c fixing of accessories, testing, commssioning and connection of all circuit, incoming and outgoing cables etc. as required. (MR)
1
1943
1943
Supplying and fixing 100 Amps Bus bar chamber with copper strip made with Sheet steel enclosure triple pole + neutral confirms to IS 8623 having seperate phases and neutral bus bar fixed on insulating material housing, having generous space for cable termination, mounting holes for easy wall/flush mounting louvers for better heat dissipation i/c testing, commssioning and connection of all circuit, incoming and outgoing cables etc. as required. (MR).
1
4315
4315
Supplying and fixing Double Pole sheet steel enclosure on surface/ recess along with 40 amps 240 volts DP Isolator complete with connections, testing and commissioning etc. as required.
6
1468
8808
Dismantling of GI poles/ strut embedded with anchor bolt in foundation with the help of hydra crane and reinstallation of the same to the previous position as required i/c testing, commssioning and connection of all circuit, incoming and outgoing cables etc. as required. (MR). For 3 no's of poles. (MR)
1
10826
10826
Supply and Fixing of Phenolic laminated Backelite sheet with the help of screw and gitti i/c cutting and fixing with the help of nut and washer etc. as required (MR).
1151
-
1035.9
Rebate for dismentalled items
-
-
-
Rebate for old dismentalled HPSV/LED lights
12
200
-2400
Rebate for dismentalled cable etc.
1
2000
-2000
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
6.68
252
1685.36
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
56.59
83
4725.27
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :l :1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size).
0.21
5225
1097.28
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :"1:1.5:3 (1 cement: 1.5 coarse sand (zone- III) 3 graded stone aggregate 20 mm nominal size).
0.81
7718
6251.78
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases of columns, etc. for mass concrete.
9.16
284
2609.23
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
89.45
67
6046.82
Add:- 31.27% cost index order on DSR Item Rs.22437.78
1
7016
7016.29
Deduction @ 9.50% as per finance guide line as the estimate is based on DSR Rs.29454.68
1
2798
-2798.14