If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 34,517Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
M/o Completed Schemes Under Nazul A/c -ii, South Zone
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_DDA_723875_1Bid Award Id
ViewTender No
10/EE/ELD-6/DDA/NIT/2022-23Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
ii) 25 mm
10
-
256
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
i.) GROUP B
20
-
587
ii )GROUP C
20
-
615
Supplying, installation, testing & commissioning of 80 watts 230 V perssure die cast aluminium body, IP66 LED flood light fitting having CCT 5700K to 6500K and efficacy 110 lumens/watt complete with all accessories i/c making connections. etc complete as required.
5
-
8198
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
a) 3 x 1.5 sq. mm
200
-
76
3 x 2.5 sq. mm
100
-
118
3 x 4 sq. mm
100
-
177
3 x 6 sq. mm
50
-
266
3 x 10 sq. mm
50
-
448
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
8
-
495
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 25 A modular socket outlet and 20 A modular type SP MCB "C" seriese i/c connections, testing & commissioning etc. as required ( For AC).
30
-
727
Supplying and Replacing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
i..)S.P. 5/6 amps, one way modular switch, ISI marked
20
-
48
S.P. 15/16 amps, one way modular switch, ISI marked
20
-
104
6 pin 15/16 amps modular socket outlet, ISI marked
20
-
148
S.P. 5/6 amp switch P/T , ISI marked
20
-
14
S.P. 15/16 amps P/T switch, ISI marked
20
-
68
3 pin 5/6 amps P/T socket outlet, ISI marked
20
-
32
6 pin 15/16 amps P/T socket outlet, ISI marked
20
-
85
Modular blanking plate
25
-
23
Modular base & cover plate for 8 module
4
-
142
Modular base & cover plate for 12 module
4
-
207
Modular base & cover plate for 4module
4
-
86
Modular base & cover plate for 6 module
4
-
111
Stepped type Modular Fan regulator (2 module)
30
-
310
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required
10
-
406
Supplying and fixing PVC batten/ angle holder including connections etc. as required
10
-
31
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
i)Upto 35 sq. mm (clamped with 1mm thick saddle)
100
-
44
Supplying and Replacing Metal body Exhaust fan 300mm sweep (6 Poles)having Copper wound Motor, with wire mesh on existing wall,including making hole to suit the size,connections with 3x1.5 Sq mm PVC Insulated & PVC sheathed (Round)Wire,Testing,commissioning etc as required.
10
-
1865
Supply and Fixing LED Tube light fitting having metal housing, Tube ligh etc. including connections,testing and commissioning etc as required.
LED Tube 20 Watt 4 Feet
50
-
511
LED Lamp-9 Watt(Retrofit)
20
-
63
Rewinding of ceiling fan with enamelled Insulated Copper wire of superior quality including dismantling,varnishing,Baking, providing/Replacing Bearings,reassembling,testingetc as required
50
-
641
Supplying and Replacing Metal body Heavy Duty Exhaust fan 300mm sweep (6 Poles)having Copper wound Motor, with louver shutter on existing wall,including making hole to suit the size,connections with 3x1.5 Sq mm PVC Insulated & PVC sheathed (Round)Wire,Testing,commissioning etc as required.
10
-
3094
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
20
-
2430
Supply and replacing of Wall Fan of 400 mm sweep 230 V,single phase,ISI Marked(Copper Wound) including dismantling,connection, testing as required.
12
-
2112
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
110
-
70
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
i.)6 way , Double door
2
-
1661
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
A) Single Pole
24
-
190
DP MCB
10
-
616
Triple pole and neutral
5
-
1224
Providing and fixing following rating and breaking capacity and pole MCB with thermomagnetic release and terminal spreaders in the metal enclosure inluding Pdg metal enclosure, drilling holes, making good the damege connections, etc. as required.
i)63 A, 10 KA, C series FPMCB
2
-
2063
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal/ coke and salt as required.
10
-
6855
Providing and laying 25mm x 5mm G.I strip at 0.50 metre blew ground as strip earth electrode including connection/ terminating with G.I nut bolt ,spring, washer etc as required ( Joint shall be done by overlapping & with 2 set of G.I nut bolt & sping washer spaced at 50mm)
10
-
144
Servicing of Fire Pump engine,Engine no.1720016 ,72 H.P along with Control panel including providing & replacing following spares,testing, commissioning etc as required.(as quated rate)
i.)KOEL CARE Premium Genuine Oil 20 Liters CAN B5:B18-1 No.
ii.)Lub Oil Filter(06.436.01.0.00)-2 No
iii)Fuel Filter Element(03.922.42.0.00)-2 No.
iv)Pri Air Filter Element(F6.729.07.0.00)-1 No.
v)Battery lead-2 No
vi)KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN(82.020.35.1.26)-1 No
1
-
15200
Providing, fixing, testing & commissioning of 15mm diaquartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories
i)Pendent Sprinkler/Upright Sprinkler
10
-
522
Refilling of fire Extinguisher CO2 type 4.5KG(Hydraulic pressure test ,Refilling , replacement of discharge pipe, safety valve and gauge where ever applicable, painting the cylinder & providing stickers, labeling with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities
5
-
1350
Refilling & fixing of Powder fire extinguisher (Stored Pressure Type) capacity 6 kg duly ISI mark , map 90% powder, ABC (replacement of discharge pipe , safety valve etc where ever applicable including painting the cylinder & providing stickers, labelling with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities.
5
-
1550
Supplying of the following size,1.1KV grade , PVC Insulated,PVC sheathed/XLPE Aluminium conductor , Armoured power cable.
i) 2core x 10 sq. mm
100
-
182
i) 2core x 16 sq. mm
100
-
210
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
i.)63 A
3
-
2890
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
i)100 A, 16 KA,TPMCCB
2
-
3724
Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes
in cubicle panel, making connections, etc. as required.
i.)4 pole MCCB,100A,30KA
2
-
7920
SITC 100 Amp. 440/500 Volts four pole ON load changeover switch with enclosure & handle etc. on existing wall i/c connections etc. as required
1
-
11790