Delhi Development Authority Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Delhi Development Authority - DDA Tender
Eprocure
Opening Date20 Aug 2020
Closing Date28 Aug 2020
Tender AmountRefer Documents
Costs
EMD
₹ 61,646Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
C/o Integrated Complex Of 273 Multistoreyed One Room Tenements Alongwith Facility Building Behind The Dda Project Office Manglapuri (site No.-iv)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_DDA_578464_1Bid Award Id
ViewTender No
22/EE(E)/ELD-10/DDA/2020-21Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying, installation, testing and commissioning LED Gate light fitting (IP-66 protection) of following rating complete with pressure die cast aluminium housing with poly carbonate cover & all accessories including making connection & complete as per technical specification attached.a) LED Gate light fixture 70 Watt
4
-
8642
Supplying & fixing of Galvanized single arm bracket minimum 500 mm long (to be installed at 9 mtr height) made out of suitable sized round pipe B-Class on octagonal pipe (3.20 mm Thick), 48 mm NB with 300 mm long galvanized overhang with tightening bolts etc. as reqd. Tilt angle shall be around 10 degree.
33
-
1264
Supplying & fixing of Galvanized Double arm bracket minimum 500 mm long (to be installed at 9 mtr height) made out of suitable sized round pipe B-Class on octagonal pipe (3.20 mm Thick), 48 mm NB with 300 mm long galvanized overhang with tightening bolts etc. as reqd. Tilt angle shall be around 10 degree.
6
-
2084
Supplying and Drawing of following size of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit/ pole etc. as required. (a) 3 x 1.5 sq. mm
450
-
54
Supplying of following size of XLPE insulated / PVC sheathed al. Conductor armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd.
i) 3.5C x 25sq.mm
500
-
341
ii) 2C x 16 sq mm
1300
-
217
Providing boring and laying of HDPE pipes (ISI marked) confirming to IS:4984 with pressure rating of 6kg/Sq.cm by trench less technology with no dig. method by making bore hole in horizontal direction across the road with boring equipment i/c jointing, cleaning Rodding of pipe performing mandrel test providing suitable covers on mouth of pipes, excavation of pits of required size & depth etc. as required.a) 110 mm (outer dia)
100
-
724
Lying of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1. KV grade of following size in the existing RCC/HUME/STONEWARE/METAL/DWC pipe as required. i) upto 35 sq. mm
250
-
31
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.i) upto 35 sq. mm
1550
-
323
Supplying and making indoor end termination with double brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A)3 core, 10 Sq.mm. (22 mm))
10
-
211
b)4 core, 25 Sq.mm. (28 mm)
4
-
250
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface/recess conduit/sub main wiring /cable as reqd.
1800
-
37
Earthing with G.I earth pipe 4.5 mtr. long X 40 mm dia i/c accessories and providing masonry enclosure with cover plate, having locking arrangement and watering pipe etc. with charcoal or coke & Salt as reqd.
10
-
5308
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with GI nut, bolt, spring washer, excavation and refilling etc. as required.
20
-
483
Providing & Fixing 25 mm X 5 mm G.I Strip on surface on in recess for connection etc. as reqd.
20
-
206
Supplying, installation, testing & commissioning of floor mounted free standing type L.T. cubical main feeder pillar duly compartmentalized (outdoor type)of Size 1450X1000X500 mm for 415 A 3 phase 50 Hz made out of 2mm thick MS CRCA sheet with 4 nos. x 600 mm long legs made of M.S angle iron of size 40 mm x 40 mm x 5 mm thick along with frame & legs suitably grouted in foundation i/c connection inter connection of the accessories mounted there on with suitable size of copper wire/strip with thimble/lugs, earthing the body of the feeder pillar i/c supplying & fixing of the following items and as per technical specification enclosed capable to accomodated following items. (incomer) (A) 100 Amp. TPN MCCB (25KA) 415 volts switch disconnector fuse unit with HRC fuses (interior only) - 1 No. (inc) (B) LED Type Phase indicating - (R,Y& B) Lamps provided with 2A SP MCBs for protection having lens and lamp openable from the top.-3 nos. Outgoing (C)SP MCB-10/32Amps-B Series (10 KA)-12 nos. (D) FP MCB - 40 Amps-C Series (10 KA) - 4 nos. (C) Voltmeter (0-415 V) 96 sq. mm with selector switch - 1 set.
(D) Ammeter (0-100 A) 96 sq.mm with selector switch & 150/5 Amp. ratio CTs-1 set.
(E) Indication lamp -1set & on/ off push buttons - 2 No
(G) 2 Pole Contactor with a thermal rating of 63A - 3 nos. (H)Time Switch with Daily dial, suitable for operation on 230 Volt, Single phase, 50 Hz, AC Supply -3 Nos.
(I) Auto/Manual Selector switch - 1 No. (J) 100 Amp, 4 strip aluminium busbar - 1 No. (k) Danger notice plate - 1 Nos.
2
-
74753
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements