Ambedkar University Delhi Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Ambedkar University Delhi - AUD Tender
Eprocure
Opening Date7 Feb 2024
Closing Date20 Feb 2024
Tender Amount₹ 6,09,939
Costs
EMD
₹ 12,500Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AUD_253452_1Bid Award Id
ViewTender No
02/EE/EMU/AUD/2023-24Tender Authority
Ambedkar University Delhi ViewPurchaser Address
-Website
http://https://aud.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
68.9
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
2.11
-
-
CEMENT CONCRET (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
1.84
-
-
CEMENT CONCRET (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1.05
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
18.36
-
-
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick
29.7
-
-
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.84
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
1.17
-
-
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
0.12
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
148.18
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-Charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
16.25
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer
197.95
-
-
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
49.4
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
318.37
-
-
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.Two or more coats on new work
197.95
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
146.09
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
30.43
-
-
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
13
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
24.94
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
18.91
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
3.18
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS :1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :100x10 mm
322
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
4
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete including skirting
1.49
-
-
12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
10.86
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 20 mm nominal outer dia Pipes
29
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
12
-
-
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
2
-
-
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complet
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm bend
4
-
-
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5
1
-
-
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground/ own dumping ground for all lifts, complete as per directions of Engineer-in-charge
10
-
-
Dismantling of exhisting non functional G.I. pipes (external work) withine the pump room and make functional connection , manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 50 mm nominal bore
1
-
-
Shifting of non serviceable material (old fan and other electrical material) from pump house and where ever required within the campus as per direction of Engineer-in - Charge
1
-
-
Taking out and refixing of MS steel grill fixed type window Opening including with all necessary repair including welding etc and refixing with hold fast embedding in cement concrete 1:2:4.
2
-
-
Providing and fixing modular PVC/ HDHMR water & termite resistance plywood vanity for washbasin cabinet of min size 580 x 451x680 mm along with all stainless steel accessories. Including with all fixtures basin, CP pillar cock, waste jalli,waste pipe,Angle value, connection pipe etc all complete. cabinate comes with enough storage of waste water can consist of 20L. All complete of approved quality and make as per the direction of Engineer in charge.
1
-
-
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:1. Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 2. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
54.5
-
-
Electrical work
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
8
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 4 sq. mm
65
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
95
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 A switch
14
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A socket outlet
14
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mm X 75mm)
3
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 6 Module (200mm X 75mm)
7
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required 1 run of cable.
100
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
8
-
-
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
150
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.2 X 16 sq. mm (22mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 35 sq. mm (32mm)
2
-
-
Supplying, fixing and termination of CAT 6 information outlet (I/O) for data, voice rack end complete with feruling and end termination as required. [Make:-(Belden/Legrand-Myrius/MK/Schnider/Crabtree)]
3
-
-
Supplying, Installation, Testing and Commisioning of Indoor decorative 20 Watt LED plastic batten with opal diffuser IP20 mimimum 2000 lumens with cool day light and operating voltage of 240V complete as required.(Halonix Part no. HLB-33-20-CW-IP or its equivalent, Havells, Crompton Greaves)
4
-
-
Supplying and fixing following rating, double pole, 240 V, C Curve MCB in the existing Single phase MCB DB complete with connections, testing and commissioning etc. as required.
2
-
-
Supply of 1.1 KV grade XLPE copper armoured conductor cable of size 2 X 16 sq. mm
65
-
-
Supply of 1.1 KV grade XLPE aluminium armoured conductor cable of size 3.5 core X 35 sq. mm
65
-
-
Supplying,fixing, connecting, commissioning & testing of ceiling fan 1200 mm sweep/48", ISI & BEE 5 Star rated without regulator including wiring with 1.5 sqmm PVC insulated copper wire single core cable complete with 3 nos. blades, 30 cm long down rod, 2 nos. canopies, copper winding suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. [Halonix Zephyr 48-inch 50-Watt Power Saver Ceiling Fan (White), 340 rpm] or equivalent make Crompton Greaves Greaves, Bajaj, Havells)
2
-
-
Supplying, Installation, Testing and Commisioning of 10W Energy efficient wall mounted LED Bulk head luminaire made of engineering plastic with opal diffuser IP 65 cool day light and operating voltage of 240V complete as required.(Halonix Part no. HLBH-03-10-CW or its equivalent, Havells, Crompton Greaves)
1
-
-
Supplying, Installation, Testing and Commisioning of LT Panel 1200mm (W) x 900mm (H) x 300mm (D) duly powder coated including entry for cable incoming and outgoing including MS Stand, aluminium bus bar, MCCB for main incoming and TPN MCB's for outgoing complete as required and as per direction of Engineer Incharge.
1
-
-
Supplying, Installation, Testing and Commisioning 9U 550X450mm Rack with PDU 6 Socket, 10" Tray(2 Nos), Cable Organiser 1U Closed, 2 Fan & Hardware Kit etc.(Approved Makes:-Panduit/Andtronics.)
1
-
-
Supply, installation, Testing and Commissioning of CAT 6 24 port loaded Patch panel for connections etc. as required. (Approved Makes :-Legrand/ Panduit/ D-Link.
1
-
-
Buy back for taking away the existing LT panel installed in the pumphouse including dismantling of the existing LT panel complete as per direction of Engineer in charge. The qouted amount to be paid by the Contractor or to be recovered from the Contractor as per actual quantity.
1
-
-
Evaluation Notes How It Works ?
Potential Partner