Military Engineer Services Tender

View complete overview of Daman & Diu MES Tender

Military Engineer Services - MES Tender

Works
Consultancy Services
Eprocure
Opening Date8 Jun 2023
Closing Date6 Jul 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Structural auditing of building Nos P-64(G+3) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.    

1

-

-

... More
Structural auditing of building Nos P-65(G+3)in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.  

1

-

-

... More
Structural auditing of building Nos P-66(G+3) in TRV Area at ICGAS Daman by visual inspection with photography and conducting adequate/required number of ND Tests and preparation and submission of ND test reports comprising the followings:- (a) Site visit, preparation and submission of detailed visual inspection and photography of buildings complete all specified and directed by Engineer-in-Charge. (b) Conducting adequate/required number ND Tests to be conducted by NABL accredited lab including rebound hammer test, Ultra sonic pulse Velocity Test (UPV test), Half-cell protentiometer test (HCP) and Carbonation test, Ultra thickness test, Core test and Compression test, Cover meter test, Chloride Profile test, for steel truss member and magnetic particle inspection for welds to defect surface and sub-surface discontinuity in welds and all other tests which is required for ascertaing the stability of structure, etc. (c) Providing of detailed report and recommendation including remedles for structural improvement/recommendation for further use of buildings or repair works to be carried out duly vetted by IIT/Govt Engineering college. (d) Submission Estimate, suggested repair/remedial measure and product specification of any other special items of material (alongwith manufacturer literature of special item of materials) to be incorporated for repairs. (e) Submission of details repairs for preparation of BOQ alongwith 06 sets of drawings(Hard and soft copy) indicating proposed addition/alteration/repairs. (f) Submission of any other details/documents, as required at the opinion of consultant. (g) Structural Engineer will visit the site during currency of repair work and after the repair work. He will also give the stability certificate of the structure. Note :- The cost of labour, transportation of T&P, scaffolding and making good the disturbed surfaces of structure and all equipment required for testing from point to point are deemed to be included in quoted rate.    

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.