Military Engineer Services Tender
View complete overview of Daman & Diu MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Feb 2024
Closing Date1 Apr 2024
Tender Amount₹ 29,28,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 67,600Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Provision Of 125 Kva Dg Set At Otm Complex
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_644389_1Bid Award Id
ViewTender No
8717/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(C) ALTERNATOR: 125 KVA at 0.8 PF, 3 phase, 4 wire, 50 Hz, 1500 RPM, self excited and self regulated, screen protected, drip proof, insulation class H, IP-23 self ventilated and suitable for above mentioned diesel engine.
-
-
-
... More
(D) AMF PANEL : Out door, mounted on MS iron frame 50x50x6mm with PCC Foundation, self supported, CPRI approved make, front and rear openable, diuble door hinged type with locking arrangement and sloping top canopy, ventilators on both sides with wire mesh, duly powder coated 7 tank process complete including and accomodating the following: (i) 4 Pole, 415 Volts rating rapturing capacity 36 KA thermal magnetic release, fixed over load and short circuit protection- 02 (1 no for Commercial and DG supply) (ii) AMF control circuit with HRC backup fuses complete with all DC control relays/line voltage monitor (LVM) as per OEM specifications incorporating engine start, stop, three attempt starting facility and faliure to start etc with suitable capacity digital Voltmeter, Ammeter, Frequency meter,Indicating lamps. ON/OFF lamps, bus bar, circuit diagram plate,Automatic battery changing unit, Power conctor 4 pole, 415 V with 1NO+1NC auxillary contactor.
-
-
-
... More
Note:- (a) Any civil work if required is included in quoted rates (b) Contractor shall submit the detailed specification, perticular model, make and litrature and calculations for bus bar selection for both DG set and AMF Panel alongwith Drg, for approval of Accepting Officer before placing the order.
-
-
-
... More
(b) Contractor shall submit the detailed specification, perticular model, make and litrature and calculations for bus bar selection for both DG set and AMF Panel alongwith Drg, for approval of Accepting Officer before placing the order.
-
-
-
... More
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6.3 mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32x6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1, RCC cover 1:2:4 type B1 with and including 5mm TMT @ 150mm c/c both ways, excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value, complete all as specified and directed.
10
-
-
... More
Supply, installation,testing & commissioning of powder coated double door, compartmentalised cubical LV outdoor panel fabricated out of 3 mm thick CRCA sheet steel weather proof, vermin proof, tappered canopy and suitable gasket for stappage of rainwater suitable for 415 Volts, 50 Hz, phase, 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, interconnection, earthing, labeling electrical interlocking suitable for termination of cables including, supply and fixing of following switch gear and accssories in the panel, complete as required. The panel should be manufactured by the manufacturer, who is manufacturing CPRI approved panel and having Protection IP-65
1
-
-
... More
INCOMER (I) ACB 1000 Amps, 3 phase, 440 Volts, 4 pole, 55 KA at 500 Volts AC operational voltage suitable for aluminium and copper termination, microprocessor release relay, overload, short circuit and earth fault relay with display, shunt release, undervoltage release, coil voltage 440 Volts conforming to latast IS code, manual operated draw out type complete in all respect - 01 Nos (for incoming) . BUSBARS : Electrolyte copper busbar PVC colour sleeved 1000 Amps capacity TPN mounted on hygroscopic insulator duly colour coded RYB & Green sleeves- 01 Set
-
-
-
... More
OUTGOING:- (i) MCCB 4 pole, 415 Volts, 600 Amps rating capacity with rapturing capacity 36 KA with variable O/C, S/C & E&F release -02 No (for BUVIK)
-
-
-
... More
(ii) MCCB 4 pole, 415 Volts, 250 Amps rating capacity with rapturing capacity 36 KA with variable O/C, S/C & E&F release -02 No
-
-
-
... More
(iii) MCCB 4 pole, 415 Volts, 100 Amps rating capacity with rapturing capacity 25 KA with variable O/C, S/C & E&F release -01 No
-
-
-
... More
(iv) MCB SPN , 415 Volts, 40 Amps rating capacity with rapturing capacity 10 KA - 01 Nos
-
-
-
... More
(v) Timer switch (Auto switching device operating on real time) digital type with min switching time of 1 sec having wide range of switches week & day programe with reserve 30 min of make GE/ABB/Siemens/Legrand- 01 set (vi) LED type phase indicator set with controlling fuses for RYB - 01 set of 03 pices only. The panel should be of one of Legrand/L&T/ABB makes all as per OEM manufacturing design/ guideline and all switchgears of OEM make. NOTE:- (a) The constructional & general arrangement of drawings showing the size of panel, details of quantity & make of materials with technical particulars/ specification, necessary certification from above manufacture shall be submitted by the contractor for approval of accepting officer. (b) Any civil work involved in installation of panel board including making canopy for raincover deemed to be included in item rate. (c) Engineer-in-charge shall ensure that the panel shall be manufactured as per approved drawing only. contractor shall arrange inspection for panel at factory premises before dispatch. the inspection shall be carried out by the nominated representative of Accepting officer.
-
-
-
... More
(vi) LED type phase indicator set with controlling fuses for RYB - 01 set of 03 pices only.
-
-
-
... More
The panel should be of one of Legrand/L&T/ABB makes all as per OEM manufacturing design/ guideline and all switchgears of OEM make.
-
-
-
... More
NOTE:- (a) The constructional & general arrangement of drawings showing the size of panel, details of quantity & make of materials with technical particulars/ specification, necessary certification from above manufacture shall be submitted by the contractor for approval of accepting officer. (b) Any civil work involved in installation of panel board including making canopy for raincover deemed to be included in item rate. (c) Engineer-in-charge shall ensure that the panel shall be manufactured as per approved drawing only. contractor shall arrange inspection for panel at factory premises before dispatch. the inspection shall be carried out by the nominated representative of Accepting Officer.
-
-
-
... More
Supply, installation,testing & commissioning of powder coated double door, compartmentalised cubical LV outdoor panel fabricated out of 3 mm thick CRCA sheet steel weather proof, vermin proof, tappered canopy and suitable gasket for stappage of rainwater suitable for 415 Volts, 50 Hz, phase, 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, interconnection, earthing, labeling electrical interlocking suitable for termination of cables including, supply and fixing of following switch gear and accssories in the panel, complete as required. The panel should be manufactured by the manufacturer, who is manufacturing CPRI approved panel and having Protection IP-65 (DG set PANEL)
1
-
-
... More
INCOMER (I) MCCB 600 Amps, 3 phase, 440 Volts, 4 pole, 55 KA complete in all respect - 01 Nos (for incoming) . BUSBARS : Electrolyte copper busbar PVC colour sleeved 800 Amps capacity TPN mounted on hygroscopic insulator duly colour coded RYB & Green sleeves- 01 Set
-
-
-
... More
OUTGOING:- (i) MCCB 4 pole, 415 Volts, 300 Amps rating capacity with rapturing capacity 36 KA with variable O/C, S/C & E&F release -02 No (for BUVIK)
-
-
-
... More
(ii) MCCB 4 pole, 415 Volts, 150 Amps rating capacity with rapturing capacity 36 KA with variable O/C, S/C & E&F release -02 No
-
-
-
... More
(iii) MCB SPN , 415 Volts, 40 Amps rating capacity with rapturing capacity 10 KA - 01 Nos
-
-
-
... More
(iv) LED type phase indicator set with controlling fuses for RYB - 01 set of 03 pices only.
-
-
-
... More
The panel should be of one of Legrand/L&T/ABB makes all as per OEM manufacturing design/ guideline and all switchgears of OEM make.
-
-
-
... More
NOTE:- (a) The constructional & general arrangement of drawings showing the size of panel, details of quantity & make of materials with technical particulars/ specification, necessary certification from above manufacture shall be submitted by the contractor for approval of accepting officer. (b) Any civil work involved in installation of panel board including making canopy for raincover deemed to be included in item rate. (c) Engineer-in-charge shall ensure that the panel shall be manufactured as per approved drawing only. contractor shall arrange inspection for panel at factory premises before dispatch. the inspection shall be carried out by the nominated representative of Accepting officer.
-
-
-
... More
Supply and laying, jointing and testing XLPE insulated, extruded PVC outer sheathed and inner sheath, galvanised steel armoured cable with alluminium conductor suitable for rated voltage of 1100 Volts grade (Heavy Duty) 300sqmm 3.5 core armoured cable laid in trenches / pipe / ducts or on pole complete all as specified and direcetd. . .
30
-
-
... More
Supply and laying, jointing and testing XLPE insulated, extruded PVC outer sheathed and inner sheath, galvanised steel armoured cable with alluminium conductor suitable for rated voltage of 1100 Volts grade (Heavy Duty) 120sqmm 3.5 core armoured cable laid in trenches / pipe / ducts or on pole complete all as specified and direcetd. . .
250
-
-
... More
Supply and laying, jointing and testing XLPE insulated, extruded PVC outer sheathed and inner sheath, galvanised steel armoured cable with alluminium conductor suitable for rated voltage of 1100 Volts grade (Heavy Duty) 95sqmm 3.5 core armoured cable laid in trenches / pipe / ducts or on pole complete all as specified and direcetd. . .
20
-
-
... More
Supply and laying, jointing and testing XLPE insulated, extruded PVC outer sheathed and inner sheath, galvanised steel armoured cable with alluminium conductor suitable for rated voltage of 1100 Volts grade (Heavy Duty) 50sqmm 3.5 core armoured cable laid in trenches / pipe / ducts or on pole complete all as specified and direcetd. . .
50
-
-
... More
Material and labour for submain wiring along with earth wire using 2x 6.0 sq mm (colour coading) + 1x 6.0 sq mm earth wire (green colour) of single core PVC insulated multistranded copper conductor 1100 Volts grade FRLS type in and including PVC casing capping of size not less than 25 mm dia (ISI marked) with all accessories such as bend, junction boxes, short pipes of suitable size complete all as specified. Note: Two run of 6.0 sqmm cable and one run of 6.0 sqmm cable and one run of PVC casing capping will be measured as one unit.
30
-
-
... More
S&F MCCB DB BOX,double door, 3 phase, 415 Volts, with min 200 Apms copper bus bar, 4 pole, 4 way with extended busbar for mounting of MCCB, MCB etc complete all as specified and as directed.
3
-
-
... More
S&F MCCB FP 150 Amps, 50 Hz, 415 V , rapturing capacity 35 KA including fixing in MCCB DB with necessary arrangement or fixed on wall complete in all respect as specified and directed.
3
-
-
... More
S&F MCB TPN 63 Amp rating 415 V, 10 kA, 'C' curve in MCB DB complete with connection, commissioning and testing complete all as specified and as directed.
7
-
-
... More
S&F MCB SPN 63 Amp rating 240 V, 10 kA, 'C' curve in MCB DB complete with connection, commissioning and testing complete all as specified and as directed.
3
-
-
... More
S&F MCB SPN 40 Amp rating 240 V, 10 kA, 'C' curve in MCB DB complete with connection, commissioning and testing complete all as specified and as directed.
6
-
-
... More
S&F MCB SPN 32 Amp rating 240 V, 10 kA, 'C' curve in MCB DB complete with connection, commissioning and testing complete all as specified and as directed.
6
-
-
... More
S&F MCB SP 6-32 Amp rating 240 V, 10 kA, 'C' curve in MCB DB complete with connection, commissioning and testing complete all as specified and as directed.
6
-
-
... More
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth; for laying of cables, protection pipes and foundations etc. and getting out in soft/loose soil all as specified and directed.
8
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed.
6.8
-
-
... More
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
1.2
-
-
... More
Cutting of existing bituminous surface/PCC hard standing by using mechanical method of any type for laying of cables/GI protection pipe and making good of disturbed surfaces to match with adjoining surface complete all as specified and directed . Note:-PCC for making good with PCC 1:3:6 shall be included in the above quoted rates )
2
-
-
... More
Material and labour for GI pipe 50 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection and including removing old unserviceable itemcomplete all as specified and directed. Make :- Jindal/Tata/BST
36
-
-
... More
Supply and fix 100 mm dia DWC pipe for cable protection in underground complete with all accessories complete all as per specified and as directed by Engineer-in-Charge.
30
-
-
... More
Cable tray 150 mm wide x 50 mm deep, hot dip galvanised with standard slot pattern manufactured from cold rolled sheet min thickness 2 mm, perforated type including provision of fixing arrangement, all bend and fittings, nuts and boalts, cable tray cover etc for proper securing to beams or suspended from ceiling, including disconnecting the existing cable refing it back inside the cable tray with appropriate saddling arrangement and including the cable tray cover complete all as specified and directed.
40
-
-