Department Of Rural Development And Panchayats Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.
Department Of Rural Development And Panchayats Tender
Opening Date1 Sep 2019
Closing Date16 Sep 2019
Tender AmountRefer Documents
Costs
EMD
₹ 29,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
55457Bid Award Id
ViewTender No
55457Tender Authority
Department Of Rural Development And Panchayats ViewPurchaser Address
-Website
http://eproc.cgstate.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Construction of embankment with approved material obtained from borrow pits, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 (Beyond 250m)with all leads as per Technical Specification Clause 301.5(Having CBR more than 5)
4665
1058955
227
... More
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR more than 7) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
1009.49
239248
237
... More
Gravel/Soil- aggregate Base (Table 400.2 ) Grading C Construction of granular sub-base by providing well graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory rollers of 80 to 100KN static weight to achieve the desired density, complete as per Technical Specification Clause 402.
987.04
1351251
1369
... More
Semi-Reflective Traffic signs upto 0.90 sqm
Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
2.88
21401
7431
... More
Providing & Fixing of PMGSY 'Logo' board
Providing and fixing of typical PMGSY logo board as per MoRD specifications and drawings.
1
7454
7454
... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
20902
20902
... More
Providing and fixing 'Citizen Information Board' of PMGSY Project (A) Providing and fixing of typical " PMGSY Citizen Information Board" with Logo as per MoRD specifications & drawings, made of 75 mm square or 75 mm dia circular steel tube of 12 SWG 3.2 m height and cross member 2 nos 1m long, fixed with angle iron 50x50x5 mm MS angle on the back
1
15767
15767
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 (i) 5th Kilometre Stone (precast)
-
-
4000
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
Ordinary Kilometer Stone (Precast)
3
7002
2334
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
200 m stone (precast)
6
3456
576
... More
Boundary Pillar
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
50
34250
685
... More
Excavation for Structure as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
248.67
55951
225
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specification Clause 802,803,1202 & 1203 III. P.C.C grade M 20 (Nominal mix (1:2:4)
-
-
6195
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specification Clause 802,803,1202 & 1203 I. P.C.C grade M 10 (Nominal mix (1:3:6)
-
-
5408
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specification Clause 802,803,1202 & 1203 II. P.C.C grade M 15 (Nominal mix (1:2.5:5)
159.51
870606
5458
... More
Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specification Clause 802,804,805,806,807,1202 & 1204,
For height upto 5 m
II. P.C.C. grade M 20 (Nominal mix (1:2:4)
-
-
6335
... More
Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specification Clause 802,804,805,806,807,1202 & 1204,
For height upto 5 m
II. P.C.C. grade M 15 (Nominal mix (1:2.5:5)
105
592515
5643
... More
Providing and laying concrete for reinforced cement concrete in superstructure as per drawing and technical specification Clause 800,1205.4 & 1205.5 R.C.C. grade M 25 (Design Mix)
12.27
92970
7577
... More
Providing and laying cement concrete wearing course M-30 grade including reinforcement complete as per drawing and technical specification. For Slab
3.54
47678
13457
... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
0.79
67748
85541
... More
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
54
20844
386
... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
36.24
67841
1872
... More
Filler Joint (II) Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
45
21555
479
... More
Drainage spouts complete as per drawing and technical specifications Clause 1209
-
-
2285
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Granular material
36.36
33306
916
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
24.03
55750
2320
... More
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
9.72
19459
2002
... More
Laying Reinforced Cement Concrete Pipe NP3 as per drawing and technical specification Clause 1402.6
Providing and laying reinforced cement concrete pipe NP3 for culverts on first Class bedding in single row including fixing with cement mortar 1:2 but excluding excavation, bedding protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (A) 1200 mm dia
-
-
9867
... More
Laying Reinforced Cement Concrete Pipe NP3 as per drawing and technical specification Clause 1402.6
Providing and laying reinforced cement concrete pipe NP3 for culverts on first Class bedding in single row including fixing with cement mortar 1:2 but excluding excavation, bedding protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
(B) 1000 mm dia
-
-
7248
... More
Laying Reinforced Cement Concrete Pipe NP3 as per drawing and technical specification Clause 1402.6
Providing and laying reinforced cement concrete pipe NP3 for culverts on first Class bedding in single row including fixing with cement mortar 1:2 but excluding excavation, bedding protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
(C) 750 mm dia
-
-
5779
... More
Providing and laying reinforced cement concrete pipe NP3 for Culverts/ Burried conduits on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106.
(A) 600 mm dia
-
-
4010
... More
Bedding for Causeway/Pipes
(II) Type B (First Class) Bedding Laying (First Class) bedding with well compacted sand, moorum or approved granular material as per Clause 1105 (ii)
-
-
1338
... More
Excavation in Cutting in Soil by manual means Excavation for roadway in soil for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
63.44
6090
96
... More
Construction of Plain Cement Concrete Drain with P.C.C. grade M-15 including all shuttering/form work etc. complete as per drawings/technical specification and direction of engineer in charge.
34.91
186258
5335
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
For height upto 5 m
III.R.C.C grade M 20
3.94
25688
6524
... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
0.32
26643
84582
... More
1 st Year maintenance
1.56
46650
30000
... More
2 nd Year maintenance
1.56
62200
40000
... More
3 rd Year maintenance
1.56
108850
70000
... More
4 th Year maintenance
1.56
171050
110000
... More
5 th Year maintenance
1.56
233250
150000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements