Municipal Corporation Tender
View complete overview of Chandigarh Municipal Corporation Tender
Municipal Corporation Tender
Eprocure
Opening Date25 Feb 2021
Closing Date5 Mar 2021
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MCC_58477_1Bid Award Id
ViewTender No
09/E/MCC/2021Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://http://mcchandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & laying of ISI marked 4 core 16 mm sq armoured cable loose in trench/pipe:-
Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havells/ Finolex/ Ecko/ Lapp/ Cirtina conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 1.7 MV CBPIP (external ). The specification of the cable as below:-
i) Conductor – Aluminum
ii) Core – 4
iii) Working Voltage – 1100 V
iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 6
vi) Insulation Thickness – 1.0mm (Nominal)
vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mm
ix) Nominal size of Armoured Wire/Strip – 4x0.8mm
x) Approximate O.D. – 22mm
Maximum D.C Resistance at 20 Deg. C – 1.91 ohm/km
The work shall be executed to the entire satisfaction of Engineer-in-Charge
1054
-
200
... More
G.I. Earth pipe electrode with salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge.
9
-
4000
... More
P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required.
18
-
140
... More
Supply & Erection of PVC Insulated (Un-sheathed) Copper Conductor Cable ISI marked size 1.5mm2.
Supply & Erection of ISI Marked PVC insulated Single Core 1.5mm2 cable of Copper Conductor (Un-sheathed) of make Havells/ Finolex/ Ecko/ Lapp/ Polycab/ KEI/ Cirtina left bare in pipe of suitable size excluding cost and erection of pipe etc. (i) Cable size 1.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. uted to the entire satisfaction of Engineer-in-charge.
504
-
25
... More
Supply & Erection of Three Phase Aluminum Bus Bar
Supply & Erection of Three Phase Aluminum Bus Bar of size 300mmx25mmx4mm with L type fuse unit to be fixed on Porcelein insulators in the existing pedestal with required nuts, bolts & M.S. sheet. The fuse links should be equal to the number of out going circuits. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
1
-
1800
... More
PAINTING & NUMBERING OF POLES 7.5/9 Mtr. LONG: -
Painting of poles above ground level with two coats of Al paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length.
18
-
200
... More
S&E of Sheet metal/iron clad triple pole switch with neutral link 63 Amp.415 Volts.
Supply & erection of 100 A/415 Volts ISI marked sheet metal iron clad switch of make Havels/standard/L&T on existing surface with GI Bolts & Nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including bonding to the existing earth. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
1
-
3900
... More
Supply & Erection of Three Phase Sensor based Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons /L&T/Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-
1. It shall have 3 contactors of capacity 40 Amp. Each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage. 2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 20Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS.
1
-
15000
... More
Supply & erection of steel tubular 9 mtr pole 410 SP-27 conforming to IS-2713-1980, (Part-I & II) having over all length of 9 Meter and welded in 3 steps and having approximate Wt. 108 Kgs. With the following specifications:-
a) The poll shall have cross-sectional length of 5.00, 2.00, 2.00 Mtrs.
b) The outside dia and thickness shall be114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.
c)The pole shall be erected 1.50mtrs. Below the ground level in 8” internal ready made RCC muff.
d) The gap between the pole and the muff shall be filled with the cement concrete 1:2:4.The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
18
-
10000
... More
S&E of Outdoor type BOTH SIDE OPEN ABLE M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos.legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mmx100mmx6mm thick at the bottom of the legs. The front side of the pedestal should be openable with hiunged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. M.S. sheet of 16 G thickness and 1200mm x 150mm size be fixed at the front to cover the entry of cables. Four No. supporting members each of size 50mmx6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN,BBC, Timer and energy meter etc.The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. The legs of the pedestal shall be embedded in the 1:2:4 R C.C. mixture by digging 1½' deep as required. The letter 'M.C.C.' in 4" size shall be written on the front door of the Pedestal. The job also includes Supply & erection one No. wooden plank/ board of size 1'-6" x 1'-6" and 25mm thick suitable for fixing energy meter including cost of screws, nuts & bolts in cubical pedestal complete in all respects. The pedestal will be housed on RCC Foundation platform of size 900 mm deep (450 mm underground and 450 mm above ground x 910 mm long x 360 mm wide including sufficient number of entries for cable with DWC pipe The work shall be executed to the entire satisfaction of Engineer-in-Charge.
1
-
17500
... More
Supply & erection of high power LED flood light luminaries : High-brightness White LEDs sources with high transmittance LENS on each LEDs, system lumen output of Minimum 20000 lumens, in Maximum 200watt System Watt Consumption with 100 lms/Watt system luminous efficacy, 4000 K color temperature & 70 CRI value for ensuring good quality light output. Life of at least 50,000 hours at 70% lumen maintenance & LED driver efficiency 95% Power factor greater than 0.90, THD15% & min 6KV surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit mis wiring, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge The luminary should be GFS65.56C0.P of GE make or Philips/ BAJAJ/HAVELLS/SCHREDER/WIPRO. The detailed specification for supply of LED Street light luminaries is as under (with 05 years warranty) :-
1. Input voltage 150-270VAC/50Hz 2. System Efficacy Minimum 100 Lm/W
3. Uniformity Ratio of min to Av illumination Min 0.3
4. Usage hours 10-12 Hrs/day
5. Power Factor 0.95
6. Life Expectancy Minimum 50,000 Hrs with 70% Lumens
8. Power Consumption Of system 200 Watt Maximum 9. Lumen output Minimum 7200 Lumens
10. Color temp. 4000 K
11. LED High Power SMD LED 12. Working Humidity 10% to 90% as 1 to MSL
13. Ingress protection IP-66
14. Surge Protection Minimum 6 KV
15. Coloring Rendering Index 70 16. Total Harmonic Distortion 15%Max
17. Average lighting Beam Angle 120 Deg
18. Make of LED Make NICHIA/OSRAM/PHILIPSLUMILED/CREE
19. Luminary Casing Pressure die cast aluminum 21. Control of circuit Compatible to LED
22. Lamp starting time Should not be more than 10 Sec
23. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air.
25. System Driver more than 85% Efficiency 26. Applicable standard The fixture should confirm to Application BIS/IES standard/IESNA LM79_80
27. Wind pressure capable to with stand 160 MPH wind velocity 28.Manufacturer should produce NABL accredited LM-79 and LM-80 Lab certificate for verifying the above mentioned system Lumen output, system power consumption & system Luminous efficacy.
6
-
18800
... More
Supply & erection of high power LED flood light luminaries : High-brightness White LEDs sources with high transmittance LENS on each LEDs, system lumen output of Minimum 15000 lumens, in Maximum 150 watt System Watt Consumption with 100 lms/Watt system luminous efficacy, 4000 K color temperature & 70 CRI value for ensuring good quality light output. Life of at least 50,000 hours at 70% lumen maintenance & LED driver efficiency 95% Power factor greater than 0.90, THD15% & min 6KV surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit mis wiring, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge The luminary should be GFS65.56C0.P of GE make or Philips/ BAJAJ/HAVELLS/SCHREDER/WIPRO. The detailed specification for supply of LED Street light luminaries is as under (with 05 years warranty) :-
1. Input voltage 150-270VAC/50Hz 2. System Efficacy Minimum 100 Lm/W
3. Uniformity Ratio of min to Av illumination Min 0.3
4. Usage hours 10-12 Hrs/day
5. Power Factor 0.95
6. Life Expectancy Minimum 50,000 Hrs with 70% Lumens
8. Power Consumption Of system 200 Watt Maximum 9. Lumen output Minimum 15000 Lumens
10. Color temp. 4000 K 11. LED High Power SMD LED 12. Working Humidity 10% to 90% as 1 to MSL
13. Ingress protection IP-66
14. Surge Protection Minimum 6 KV
15. Coloring Rendering Index 70 16. Total Harmonic Distortion 15%Max
17. Average lighting Beam Angle 120 Deg
18. Make of LED Make NICHIA/OSRAM/PHILIPSLUMILED/CREE
19. Luminary Casing Pressure die cast aluminum 21. Control of circuit Compatible to LED
22. Lamp starting time Should not be more than 10 Sec
23. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air.
25. System Driver more than 85% Efficiency 26. Applicable standard The fixture should confirm to Application BIS/IES standard/IESNA LM79_80
27. Wind pressure capable to with stand 160 MPH wind velocity 28.Manufacturer should produce NABL accredited LM-79 and LM-80 Lab certificate for verifying the above mentioned system Lumen output, system power consumption & system Luminous efficacy.
30
-
14000
... More
S/F 50mm cable protection pipe on pole: Supply and Fixing of G.I. pipe of 50 mm dia.(nominal) 3 metres length along the pole for protection of under ground cables as required.
1
-
1300
... More
Supply and Erection of 3 Feet long Angle Iron Bracket made out of 50mmx50mmx6mm. The Angle Iron Bracket is to be welded with the 0.5 mtr long G.I Canopy of 5"dia for theinstallation of 250 Watt Integral Flood Light on the top of the pole.TheCanopy shall be fixed on 12 mtr long St.pole. The job inlcudes all the petty material such as nuts,bolts extra required to complete the job to the entire satisfaction of the Engineer-in-charge.
18
-
1090
... More
Dismantling of existing bollard jali along with bollard complete in all respect as per the complete satisfaction of engineering in charge . The dismantled material needs to be submitted in store of JE incharge .
67
-
190
... More
Dismantling of existing 4.5 mtr long pole complete in all respect as per the complete satisfaction of engineering in charge . The dismantled material needs to be submitted in store of JE incharge .
35
-
300