Military Engineer Services Tender

Download documents of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date17 May 2025
Closing Date9 Jun 2025
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on same board controlled by one single pole, one way switch complete all as specified and directed.

25

103

2575

... More
All as per item No. 2.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified and directed.

10

104

1040

... More
All as per item No. 2.00 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed.

16

105

1680

... More
All as per item No. 2 here-in-before but point wiring using 4 sqmm as main wire & 4 Sq mm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed.

4

106

424

... More
Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. Note :- The quoted rates includes the cutting chasis for conduit and sunken boxes.

25

107

2675

... More
All as per item No. 8.00 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.

8

108

864

... More
All as per item No. 8.00 here-in-before but point wiring for one 5Amps socket outlet point on the same board controlled by one single pole, one way switch complete all as specified and directed.

5

109

545

... More
All as per item No. 8.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified and directed.

2

110

220

... More
All as per item No. 8.00 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed.

5

111

555

... More
All as per item No. 8.00 here-in-before but point wiring using 4sqmm as main wire & 4 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed.

2

112

224

... More
Supply and fix in repair switch piano, flush type, single pole, one way, 5 Amp, 230 volts complete all as specified and directed.

450

113

50850

... More
Supply and fix in repair switch Bell push, flush type, single pole, one way, 230 volts complete all as specified and directed.

12

114

1368

... More
Supply and fix in repair switch piano, flush type, single pole, one way, 15 Amp 230 volts complete all as specified and directed.

150

115

17250

... More
Supply and fix in repair socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified and directed.

150

116

17400

... More
Supply and fix in repair Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified and directed.

150

117

17550

... More
Supply and fix in repair ceiling rose, three terminals, PVC/ isolated body, complete all as specified and directed.

100

118

11800

... More
Supply and fix in repair Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified and directed.

40

119

4760

... More
Supply and fix in repair Fan regulator electronic, socket type, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified and directed.

50

120

6000

... More
Supply and fixing in repair LED Decorative box type batten 1x20W prewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm complete all as specified and directed.

250

121

30250

... More
Supply and fixing in repair LED Decorative box type batten 1x9W prewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm complete all as specified and directed.

100

122

12200

... More
Supply and fixing in repair LED tube rod 20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 22W, complete all as specified and directed.

40

123

4920

... More
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed . Make-Havells or its equivalent in Crompton/Wipro

25

124

3100

... More
Supply and Fix in repair LED 10 watts IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old complete all as specified and directed.

5

125

625

... More
Material and Labour for service cable 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular complete all as specified and directed.

100

126

12600

... More
Supply and fixing in repair decorative indirect post top for garden & landscape lighting of min 20 watts with IP 65 protection, resistant to impact and corrosion, anti Glare and uniform distribution complete all as specified and directed.

2

127

254

... More
Supply and fix in repair sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA, complete all as specified and directed .

4

128

512

... More
Supply and fix in repair Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, complete all as specified and directed.

2

129

258

... More
All as per item No.30.00 here-in-before but DB 8 way complete all as specified and directed.

10

130

1300

... More
Supply and fix in repair Sheet metal distribution board TPN, with double door,4 way, 415 volt with 200 Amps rated bus bar & IP 54 protection, complete all as specified and directed by Engineer-in-Charge.

2

131

262

... More
All as per item No.32 here-in-before but DB 8 way complete all as specified and directed.

1

132

132

... More
Supply and fixing Load line TPN vertical distribution board 8 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB 4 Pole 100 to 120 Amps as incomer and MCBs SP/TP as outgoing as per IS - 01 No, having IP-43 protection, complete all as specified and directed.

1

133

133

... More
Supply and fixing Load line TPN vertical distribution board 4 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB 4 Pole 100 to 120 Amps as incomer and MCBs SP/TP as outgoing as per IS - 01 No, having IP-43 protection, complete all as specified and directed.

1

134

134

... More
Supply & Fixing in repairs MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 125 Amps complete all as specified and as directed.

2

135

270

... More
Supply & Fixing in repairs TPN 100A Breaking capacity 10 KA, 415 volts, complete all as specified and as directed.

2

136

272

... More
Supply & Fixing in repair MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 63 Amps, complete all as specified and as directed.

3

137

411

... More
Supply and fix in repair TPN 63A , breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.

3

138

414

... More
Supply and fix in repair MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, complete all as specified.

2

139

278

... More
Supply and fix in repair MCB 32/ 40 Amp, 230 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.

20

140

2800

... More
Supply and fix in repair MCB 6 to 40 Amp, 230 Volt, SP, breaking capacity 10 KA, 'B' curve, complete all as specified and directed.

50

141

7050

... More
Material and labour for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.

20

142

2840

... More
Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.

40

143

5720

... More
Material and labour for Sub Main Wiring (in replacement) with two single core 6 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 6 Sqmm main cable + one run of 6 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. Notes:Taking down will be from different location and wiring will be done on location to bring electric meter outside the houses and as specified by engineer in charge.

40

144

5760

... More
Disconnecting & taking down complete ceiling fan with blade of any make 1200 mm / 1400 mm sweep from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s providing paper insulation (cuff / strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing , screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and connecting cable and depositing in E/M yard complete all as specified and directed. Note: Bush, bearing, capacitor, with nuts, bolts and sockets shall be measured and paid for separately as supply only.

240

145

34800

... More
Supply and fix in repair capacitor 2.50 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed.

250

146

36500

... More
Supply and fix in repair capacitor 3.15 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed.

80

147

11760

... More
Supply and fix in repair MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.

250

148

37000

... More
Supply and fix in repair bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.

500

149

74500

... More
Supply and fix in repair bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.

50

150

7500

... More
Supply and fix in repair PVC insulated flexible 3 core, 1sqmm size copper conductor cable of size complete all as specified and directed.

250

151

37750

... More
Supply & fixing in repair for Mild Steel Down Rod of suitable dia , 45 Cms long white or coloured, compatible to existing ceiling fans of 1200mm or 1400 mm sweep complete all as specified and directed.

30

152

4560

... More
Disconnecting and taking down ceiling fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of minor parts such as washer, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge complete all as specified and directed. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.

50

153

7650

... More
Material and Labour Spray painting of ceiling fan 1200/1400 mm sweep and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler complete all as specified and directed.

50

154

7700

... More
Disconnecting & taking down (burnt) exhaust fan of any make 300mm sweep transporting to local workshop, opening, cutting and taking out complete copper winding , cleaning with kerosene oil / diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless running and depositing in E/M yard complete all as specified and directed. Note: Bush bearing capacitor shall be measured and paid for separately.

20

155

3100

... More
All as per serial item No. 56 here-in-before but exhaust fan 450 mm sweep.

10

156

1560

... More
Supply and fix in repair capacitor 4 MFD, 440 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as specified and directed.

30

157

4710

... More
Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.

60

158

9480

... More
Material and Labour for Spray painting of Exhaust fan and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as specified and directed. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets will be measured and paid separately).

20

159

3180

... More
Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from Internal Elect Section, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturers, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable / missing spares (bush, bearing, capacitor etc), fixing the stator in rotor properly aligned and reassembling ensuring right DOR, speedy and noiseless running complete all as specified and directed.

6

160

960

... More
Supply and fixing in repair LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.

3

161

483

... More
Material and labour for cleaning complete solar panel set (36 panel) using soft brush and water solution without scratching the panel complete all as specified and directed.

1

162

162

... More
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, earth lead GI wire 4 mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:3:6) type C-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 1 Ohm. In case the test results are not found below 1 Ohm, complete earthing will be redone without any extra cost to Govt.

5

163

815

... More
Supply and fixing in repair DC distribution box for solar panel capacity upto 5kw complete all as specified and directed.

1

164

164

... More
Supply and fixing in repair AC distribution box for solar panel capacity upto 5kw complete all as specified and directed.

1

165

165

... More
Supply and fixing in replacement electronic energy meter 3 phase with LCD display complete all as specified and directed. Make- Cat Part No WR301BC7D10 of L& T or its equivalent in the makes mentioned at Appx 'B' Note : Old meter shall be deposited in MES Store.

2

166

332

... More
Supply and fixing in replacement electronic energy meter single phase with LCD display complete all as specified and directed. Make- Cat Part No WM101BC5DL0 of L& T or its equilant in the makes mentioned at Appx 'B' Note : Old meter shall be deposited in MES Store.

4

167

668

... More
Material and labour for repairing junction box of solar panel complete all as specified and directed. Note: All cost for labour, soldering diode deemed to include in quoted rate

4

239

956

... More
Note: The total amount shall subject to adjustment of credit of Rs 32954.00 for old Materials as per Schedule of Credit

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.