Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 May 2024
Closing Date26 Jun 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_656905_1Bid Award Id
ViewTender No
GE/CHD-05/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule A Notes, Schedule of Credit, Schedule B C D ,Special conditions, Particular specification and other connected documents
BOQ Items
M&L rewinding to ceiling fan motor of 1200mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conducor of size 23/.0076 upto connector block ( winding wire exc 300 gm and n-exc 350gm ) Complete all as specified and as directed by Engineer-in-charge.
560
-
-
M&L rewinding to ceiling fan motor of 1400/1500mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor cable of size 23/.0076 upto connector block ( winding wire exc 350 gm and n-exc 750gm ) Complete all as specified and as directed by Engineer-in-charge. Note for item No 4 & 5 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account
180
-
-
All as item No 05 here in above but for Exhaust fan 225 to 300mm sweep.
30
-
-
All as item No 05 here in above but for Exhaust fan 350 t0 450mm sweep.
25
-
-
All as item No 05 here in above but for Pedestal / Wall mounted fan upto 450mm sweep.
5
-
-
M&L replacement to unserviceable capacitor 2.5/3.15 mfd in lieu of provided with new capacitor oil type 2.5/3.15 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS /EPCOS/HAVELLS
980
-
-
Supply only Ball bearing suitable for celing fans of any sweep.
945
-
-
M&L for replacement to unserviceable rusted MS rod up to 3 feet including clamp, nut, bolt, washer & split pin suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.
165
-
-
M&L for replacement to unserviceable PVC canopy suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
96
-
-
M&L for replacement to unserviceable fan blades (set of three blades) suitable for 1200/1400/1500mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
80
-
-
Supply only gun metal bush suitable for celing fans of any sweep.
430
-
-
Supply only Mild steel shaft suitable for celing fans of any sweep.
290
-
-
M&L for replacement to unserviceable rubber reels with new suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
405
-
-
Preparation surfaces, cleaning thoroughly with kerosene oil ceiling fans 1200mm/1400mm/1500mm sweep to remove only dust and any type of spots and painted with synthetic enamel paint (white colour) with help of spray gun machine, including writing MES No, complete all as specified and as directed by Engineer-in-charge.
545
-
-
Taking down defective BLDC Ceiling fan of any Sweep, any make, 1200/1400/1500mm, 230 volts of any make & size from any height of the building for finding out the defects and replaced the defective parts like as BLDC Circuit plate,diode,AC convertor including servicing / overhauling the same, including replacing minor accessories like locking pins, rubber real, PVC sleeve, greasing, clamps, etc as required, and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge.
45
-
-
Supply only ball bearing suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
62
-
-
Supply only gun metal bush suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
42
-
-
Supply only mild steel shaft suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
27
-
-
M&L for replacement to unserviceable fan blades (set of three blades) suitable for 300 to 450mm sweep exhaust / pedestal/ wall complete all as specified and as directed by Engineer-in-charge.
20
-
-
M&L replacement to unserviceable capacitor 4 mfd in lieu of provided with new capacitor dry type 4 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS /EPCOS /HAVELLS
75
-
-
M&L lathe work for taking out bush from the lower body part of ceiling/Exhaust fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft complete all as specified and as directed by Engineer-in-charge.
288
-
-
Disconnecting & taking down unserviceable geyser of 25/50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares , including replacement of required number of stainless steel screws, nuts & bolts,assembling the the same after repair work and fixing in its orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified and as directed by Engineer-in-charge. Note :spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ.
252
-
-
Replacement of unserviceable Geyser thermostat switch any type/size with new thermostat switch ISI marked of range 0-100 degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc complete and all as specified
198
-
-
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
60
-
-
All as per above item No 27 here-in-before but 50 litre capacity.
2
-
-
S&F replacement of unserviceable Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.
9
-
-
All as per above item No 29 here-in-before but 50 ltr capacity.
1
-
-
Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 2000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.
205
-
-
S&F in repairs 06/08 hole Assembly for water heater ISI Marked complate all as specified and as directed. Make:-Crompton/Havells/ Venus.
55
-
-
Replacement of unserviceable Safety valve
75
-
-
Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified
40
-
-
Replacement of unserviceable 23 to 30 cm long ,10 mm bore C.P Connection with brass union
60
-
-
Replacement of unserviceable Gun metal non return valve ,15 mm bore
25
-
-
Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe
100
-
-
Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litre
55
-
-
Replacement of unserviceable Apparatus plate for Syphon Assy 50 litre
2
-
-
Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.
45
-
-
Replacement of 3-Pin plug top, 16 Amp, 230volt AC
50
-
-
Replacement of Rubber 'O' ring /gaskit for 25 ltrs
115
-
-
M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
10
-
-
M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
2
-
-
S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge .
60
-
-
Cutting chasing in brick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
26
-
-
S&F sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge.
8
-
-
S&F for 15mm bore stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
20
-
-
S&F for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
5
-
-
S & F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors including taking out unserviceable pipe complete all as specified and directed by Engineer-in-charge.
30
-
-
All as per above item No 50 here-in-before but 20mm bore
30
-
-
S&F Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia, in repairs, complete all as specified.
18
-
-
Arresting of water leakage from existing pipe line in position from GI pipe of size 15/20mm bore, including wall/roof through Men/Mechnical power, cutting threading as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified.
40
-
-
Disconnecting, opening and taking out unserviceable sealed compressor of water cooler of capacity 150/180 litres and replaced with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leakage etc complete all as specified and as directed by Engineer-in-charge. Make : SRI-RAM/ TAKAM SHAH/ KIRLOSKER .
3
-
-
All as per above item No 54 hereinbefore but water cooler of capacity 40/80 litres. Note for item No 54 & 55:
(i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured &paid separately under respective item of BOQ.
1
-
-
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of150 litres capacity complete all as specified and as directed by Engineer-in-charge.
7
-
-
All as per above item No 56 here-in-before but water cooler of capacity 40/80 litres
1
-
-
S&F for internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.
3
-
-
S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge
5
-
-
All as per above item No 59 hereinbefore but water cooler of capacity 40/80 liter
1
-
-
S&F replacement of unserviceable over load protector with new over load protector suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
4
-
-
All as per above item No 61 hereinbefore but water cooler of capacity 40/80 litre
1
-
-
S&F replacement of unserviceable fan motor with new fan motor suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
6
-
-
All as per above item No 63 hereinbefore but water cooler of capacity 40/80 liter
1
-
-
Replacement to unserviceable Condenser unit with new condenser unit of existing make and model suitable for water cooler of capacity 150/180 liters, complate all as specified and as directed.
6
-
-
All as per above item No 65 here in before but water cooler of capacity 40/80Liters.
2
-
-
M&L 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler as in repair Complete all as specified and as directed by Engineer-in-Charge.
4
-
-
S&F ball valve of PVC high pressure with polythene float & flynut of 15 mm dia suitable for 40 to 150 Ltrs water cooler after removing the unserviceable Ball valve as directed by Engineer-in-Charge.
3
-
-
M&L cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces and bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine and writing SM / MES No in 5cm height Complete all as specified and as directed by Engineer-in-Charge.
3
-
-
All as per above item No 69 here-in-before but water cooler of capacity 40/80 liter
1
-
-
S&F replacement of unserviceable thermo-state switch with new thermo-state switch suitable for water cooler any capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
4
-
-
Disconnecting & opening refrigerator of capacity 165/315 litre and taking out unserviceable sealed compressor and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :SRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .
3
-
-
Recharging of gas F-12/F-22/134 in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
6
-
-
Replacement of freezer door plastic with tension spring as per existing model suitable 160/210 litre cap.
3
-
-
Replacement of Door liner ( Plastic ) for upto 310 liter capacity
2
-
-
Replacement of Door magnetic gaskest for upto 310 litre cap.
3
-
-
Replacement of Relay box type for any cap.
4
-
-
S&F replacement of unserviceable over load protector with new over load protector suitable for refrigerator 165 to 310 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
3
-
-
Replacement of bulb unit of same size and capacity suitable for 165 to 310 ltrs refrigerator
3
-
-
S&F replacement of unserviceable fan motor with new fan motor suitable for refrigerator 165 to 310 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Opening to refrigerator freezer of capacity 180 to 310 ltr re-fixing the same after flushing out and removal of blockage brazing replacement of liquid line, filter and recharging to refrigerator with F-22/134 gas to obtain the desired cooling Complete all as specified and as directed by Engr-in-Charge. Note :-- Re-charging to refrigerator with R-22/134 gas shall be measured & paid separately under respective item of this schedule.
4
-
-
Taking out PCB unit from refrigerator carry to workshop for repair and refixing PCB unit after repair to existing refrigerator complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Disconnection and removing the unserviceable Split AC Outdoor & Indoor Unit/ window type of Capacity 1.5 to 2 Ton capacity from the existing position carefully for finding of the defects and to replace the unserviceable spare parts such as Compressor, Condensor fan mtor, condensor coil, suction & discharge valves, mother plates including carry out leak detection test, Gas charging, servicing such as cleaning and removing the dust particles accumulated in the unit and filters carefully and washing the cooling unit and Indoor unit with water and refixing the same in its original position complete including connecting up of the Copper Tubes and cable connections, testing and commissioning complete all as specified and as directed by Engineer in charge. (i) Cost of spares such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates, leak detection test, Gas charging shall be measured and paid separately under the respective Schedule. (ii) Makes & Specifications of the spare parts for replacement should be identical equivalent to the spares suitable for existing ACs.
12
-
-
Replacement of unserviceable Outdoor hermatically sealed compressor of 1.5 Ton capacity split type AC with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning & testing for leakage etc complete all as specified and directed by Engineer-in-charge Make :LG/Hitachi/Voltas/Blue Star
7
-
-
Replacement of unserviceable indoor sealed compressor of 1.5 Ton capacity window type AC with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning & testing for leakage etc complete all as specified and directed by Engineer-in-charge Make :LG/Hitachi/Voltas/Blue Star
6
-
-
All as per above item No 84 here-in-before but 2.0 Ton capacity split type AC.
2
-
-
All as per above item No 85 here-in-before but 2.0 Ton capacity window type AC.
4
-
-
upply only Condensor Fan Motor 230 Volt suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
4
-
-
Replacement of fan motor 230 Volt suitable for window type AC of 1.5 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
1
-
-
Replacement of fan motor 230 Volt suitable for window type AC of 2.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
1
-
-
Replacement of blower Unit of Indoor unit Split type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
4
-
-
Replacement of blower motor suitable for window type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
2
-
-
Replacement of Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
4
-
-
Replacement of Condensor Coil Unit made out of Copper tubing suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
1
-
-
Replacement of Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.
5
-
-
Replacement of PCB/Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2 Ton Indoor Unit of Split Type Air Conditioning complete all as directed.
3
-
-
Replacement of the unserviceable broken fan blade set from the outdoor units of Split AC Unit 1.5/2 Ton Capacity complete suitable for existing make of AC Unit.
5
-
-
S&F replacement of unserviceable starting capacitor 36 mfd with new suitable for split type AC 1.5/2 Ton capacity of any capacity, complete all as specified and as directed by Engineer-in-Charge.
10
-
-
S&F replacement of unserviceable starting capacitor 100 -120 mfd with new suitable for split type AC 1.5/2 Ton capacity of any capacity, complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Replacement of the unserviceable Display Unit and digital display for indicating temperature, temperature sensor for 1.5/2 Ton split AC unit complete all as directed.
3
-
-
Recharging of gas R-22/134 in air conditioner unit window type/ split type 1.5 ton complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
15
-
-
Recharging of gas R-22/134 in air conditioner unit window type/ split type 2.0 ton complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
3
-
-
Replacement of the damaged flexible PVC drain pipe of dia 25mm for capacity 1.5 ton, 2.0 ton Capacity AC.
55
-
-
Replacement of the old unserviceable copper pipe between indoor & outdoor unit with new Copper Pipe of 1/2" dia and connecting alongwith Insulation Sleeves to the existing position including leakage, testing complete all as directed by Engineer in charge.
25
-
-
All as per Item No 104 here in above but of capacity 1/4" dia
30
-
-
Replacement of suction valve made of brass suitable for 1.5 Ton outdoor unit of split type air conditioning complete all as directed.
3
-
-
Replacement of suction valve made of brass suitable for 2.0 Ton outdoor unit of split type air conditioning complete all as directed.
1
-
-
M&L for internal wiring for split unit of any capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.
5
-
-
Disconnecting and removing the cable connection and copper pipe alongwith all connection items carefully from the existing indoor and out door units of capacity 1.5/2.0 ton AC including stablizer from the existing position and shifting the AC unit at new places including refixing the out door and indoor units with necessary copper tubing and connecting stablizer etc for its proper functioning all as direcred and specified by Engineer-in-charge.
5
-
-
S&F sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge.
5
-
-
Detection of leakage of gas from the cooling unit & copper tubing for indoor/outdoor unit of air conditioner, with liquid nitrogen gas and arresting by gas welding and testing complete all as specified and as directed by Engineer-in-Charge. Note :- The leakage to be observed for 24 Hours
9
-
-
Replacement of the unserviceable / burnt out copper cable with pvc insulated, sheathed, multistranded copper cable 3 core 6 sqmm, ISI marked, 1100 volts Grade and connecting to the AC unit complete.
100
-
-
Supply and fixing and testing in repairs split type air condioner 5 star rating outdoor unit having hot & cold single phase 220 volt complete of capacity 2 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge Make:Voltas/hitachi/LG
2
-
-
Replacement of unserviceable air filter with new air filter suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.
4
-
-
Supply and fixing and testing in repairs split type air condioner 5 star rating indoor unit having hot & cold single phase 220 volt complete of capacity 2 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge Make:Voltas/hitachi/LG
2
-
-
Supply and fixing and testing in repairs split type air condioner 5 star rating indoor unit having hot & cold single phase 220 volt complete of capacity 1.5 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge Make:Voltas/hitachi/LG
3
-
-
Supply and fixing and testing in repairs split type air condioner 5 star rating outdoor unit having hot & cold single phase 220 volt complete of capacity 1.5 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge Make:Voltas/hitachi/LG
3
-
-
Disconnection and removing the old u/s Outdoor Stand and S&F New Outdoor Stand made of Iron bracket to accomodate the air conditioner along with fixing materials complete all as specified and as directed by Engineer-in-charge.
5
-
-
Taking down carefully dismantling voltage stabilizer of capacity 03 to 05 KVA, single phase 240 volt AC of any make and any size opening up for inspection necessary repair and replacement of worn out/defective spare parts, rewinding of main transformer with supper enameted copper wire of existing gauge and weight reassembling, connecting up, testing etc complete all as directed by Engineer-in-Charge (Necessary spare parts required for replacement shall be measured and paid for separately as supply only) and fixing is included under this item. Make of winding wire : Devi Dayal/Atlas/BPL
3
-
-
Replacement of relay condenser suitable for voltage stabilizer of capacity 3 KVA to 5 KVA of existing make and size complete all as specified and as directed by Engineer-in-charge.
3
-
-
Taking down desert cooler of any make & size fixed at different site / location and repair to desert cooler to stop any type of leakage, tightening / replacing rusted screw nuts, bolts & washers with new of same size etc including floor cleaning, scraping all scales from internal & external surfaces and painted to desert cooler synthetic enamel paint on external surface & black Japan paint on internal surfaces with help of spray gun machine including writing of MES/ SM No in 5cm height and re-fixing the desert cooler after necessary oiling and greasing complete all as specified and as directed by Engineer-in -Charge. NOTE : Spare partst shall be measured & paid seperatly under respective item of schedule .
45
-
-
Replacement of fan motor of 1/6 HP 50Hz’s suitable 230volt AC Make: Khaitan/CG/Bajaj
50
-
-
Replacement of submersiable Tulu pump / water fitting pump.Make: Khaitan/CG/Bajaj
150
-
-
Replacement of 3-Pin plug top, 5 Amp, 230volt AC
20
-
-
Replacement of Wooden pads ( set of three )
150
-
-
Replacement of the old damaged front grill unit with new suitable for desert cooler
25
-
-
Replacement of Selector switch ( three speed ) Make : KAY/GE/L&T/Siemen
25
-
-
Replacement of PVC Water distributor 3-way
35
-
-
Replacement of brackets for fan motors of desert cooler made out of flat iron of size 25mmX3mm, 300 mm long, bent to shape and including drilling of holes (set of four) etc complete all as specified and as directed by Engineer-in-charge.
23
-
-
Replacement of shaft bush set of fan motor of desert cooler complete all as specified and as directed by Engineer-in-charge.
23
-
-
Replacement of fan blades (set of blades) for 350 to 450mm desert cooler complete all as specified and as directed by Engineer-in-charge.
24
-
-
Disconnecting & opening of deep freezers and taking out unserviceable sealed compressor of capacity 210/315 litres and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etc complete all as specified and as directed by Engineer-in-charge. Make :-- SRI-RAM/ TAKAM SHAH/ KIRLOSKER. Note : (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. ( ii) Recharging with refrigerant gas shall be measured & paid separately under respective item of BOQ.
6
-
-
S&F replacement of unserviceable fan motor with new fan motor suitable for deep freezer upto 165 to 230 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
6
-
-
S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for deep freezer water cooler of 165 to 315 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge
5
-
-
replacement of the unserviceable timer switch, and S&F timer switch of same size and capacity suitable for 165 to 315 ltrs refrigerator
4
-
-
Replacement of freezer door plastic with tension spring as per existing model suitable for 165 to 315 litre capacity.
6
-
-
Replacement of Pigmy lamp (bulb)
5
-
-
S&F replacement of unserviceable over load protector with new over load protector suitable for deep freezer 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
3
-
-
Recharging of gas F-22/134 in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
8
-
-
Disconnecting and taking down unserviceable solar water heater of capacity 100 to 500 LPD from its original position along with connected items and to finding out the defects and refixing the same after repairs, in its original position connecting up water connections, testing and commissioning complete all as specified and directed by Engg-in-Charge. Note : (i) spare parts such as solar water tank, water heater will be measured and paid separatley. (ii) Misc items required for satisfactory completion of Job deemed to be included in the unit quoted rate.
4
-
-
Replacement of solar water tank made out of stainless steel alongwith puff insulation of capacity 500 ltrs of with same make of manufacturer with electrical heating backup of 2 KW . Make :-BHEL / Tata BP / Inter solar
1
-
-
Replacement of solar water heater collector (heat exchanger) for 500 ltrs solar water heater with same make of manufacturer, size and capacity,connecting up of connections complete all as specified and as directed. Make :-Kamal/BHEL/Tata BP/ Inter solar
1
-
-
Replacement of the unserviceable PVC water tank of capacity 500 Ltr from its original position along with connected items and to finding out the defects and refixing the same after repairs, making the same in serviceable condition in its original position connecting up water connections, complete all as specified and directed by Engg-in-Charge.
1
-
-
Supply and fix in repair voltage stablizer for automatic operation,single phase naturally air cooled indoor type & desined for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and capacity 5 KVA.
2
-
-
All as per above item No 144 hereinbefore but 3 KVA.
2
-
-
Disconnecting and removing the u/s and Supply fixing incl testing in repairs of Pure-R Refrigerator single phase electric driven of (500 watt) water dispenser complete all as specified and as directed by Engineer-in-Charge. Make: Voltas/blue star/Milton
1
-
-
Evaluation Notes How It Works ?