Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 44,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule A Notes, Schedule of Credit, Schedule B C D ,Special conditions, Particular specification and other connected documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface complete all as specified and directed by Engineer-in-Charge. Note :-- Rates for cutting/chases in walls and making good disturbed area deemed to be included in the quoted rate

1020

-

-

... More
Point wiring using approved colour coding as per IS ,with stranded copper conductor 1.5 sqmm (nominal area ) single core , flame retardant low smoke and low halogen FRLSH PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunken/flush boxes of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly for One light point controlled by one switch complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metel flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch socket and fan regulators to be measured and paid separately

500

-

-

... More
All as per item No 5 above but One ceiling /exhaust fan point controlled by one, one way 5 Amps modular switch.

90

-

-

... More
All as per item No 5 above but One 3 pin modular socket outlet 5 Amps on independent board

120

-

-

... More
All as per item No 5 above but One 3 pin modular socket outlet 5 Amps on same board

80

-

-

... More
All as per item No 5 above but One light point controled by two way 5 Amps modular switches.

25

-

-

... More
All as per item No 5 above but One bell/ buzzer point controled by one modular bell push on same board with other switches or on independent board.

35

-

-

... More
Point wiring using approved colour coding as per IS ,with stranded copper conductor 2.5 sqmm (nominal area ) single core , FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunkun/ flush boxs of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly for Modular Switch one way 16 Amps one module on independent board complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metel flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch socket and fan regulators to be measured and paid separately

120

-

-

... More
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc., with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity as per IS colour coding all as specified and as directed. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length

350

-

-

... More
All as per item No 12 here in above but with 2x6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete.

600

-

-

... More
M&L for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor drawn in the existing metal/ PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete all as specified and as directed. Note : Three runs of cable shall be measured as one unit.

70

-

-

... More
Supply and fixing switch piano flush type single pole one way 5 amps 230 volts complete all as specified and as directed.

300

-

-

... More
Supply and fixing socket piano flush type universal 2 in 1,3 pin 5 Amps, 230 volts complete all as specified and as directed.

150

-

-

... More
Supply and fixing switch piano flush type single pole one way 15 Amps 230 volts complete all as specified and as directed.

75

-

-

... More
Supply and fixing socket flush type universal 2 in 1, 3 pin 5 &15 Amps, 230 volts complete all as specified and as directed.

75

-

-

... More
Supply and fixing two way switch universal 5 amps 230 volts.

100

-

-

... More
Supply and fixing bell push universal 5 Amp, 230 volts.

30

-

-

... More
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body complete all as specified and as directed.

600

-

-

... More
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type all as specified and as directed. .

60

-

-

... More
Supply and Fixing Ding Dong Bell AC. 230 volts complete all as specified and as directed.

30

-

-

... More
Supply & Fixing 6 Amps 1 way one module switch complete all as specified and as directed.

500

-

-

... More
Supply & Fixing 6 Amps 2/3 pin one module switch complete all as specified and as directed.

300

-

-

... More
Supply & Fixing 6 Amps 2 way module switch complete all as specified and as directed.

40

-

-

... More
Supply & Fixing 16 Amps one way one module switch complete all as specified and as directed.

100

-

-

... More
Supply & Fixing modular multi socket outlet 6A/16 Amps 2/3 Pin socket 2 module complete all as specified and as directed.

100

-

-

... More
Supply & Fixing 6 Amps bell push one module switch complete all as specified and as directede.

20

-

-

... More
Supply & fixing PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements including disconnection and removing the unserviceable PVC casing caping complete.

150

-

-

... More
All as per Item No 30 here in above but of size 25mm

120

-

-

... More
Supply & fixing PVC casing caping of size 20mm including cut to shape and siz MCB DB, SPN, 2 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.

50

-

-

... More
Supply & fixing PVC casing caping of size 20mm including cut to shape and siz MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.

35

-

-

... More
Supply & fixing PVC casing caping of size 20mm including cut to shape and siz MCB DB, SPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.

20

-

-

... More
Supply & fixing PVC casing caping of size 20mm including cut to shape and siz MCB SP 6-32 Amps 230 volts 10 KA ISI marked complete all as specified and directed by Engg-in-Charge.

410

-

-

... More
All as per Item No 35 here in above but of capacity MCB SPN 40 Amps B Curve.

15

-

-

... More
All as per Item No 35 here in above but of capacity MCB SPN 63 Amps B Curve.

15

-

-

... More
All as per Item No 35 here in above but of capacity MCB DP 63 Amps B Curve.

40

-

-

... More
S&F Single pole and neutral enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, including taking out unserviceable MCB plug and socket unit complete all as specified and as directed.

55

-

-

... More
Supply & fixing in repair LED tube light with batten 1X18/20 watts LED, 230Volt energy efficient, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed.

400

-

-

... More
Supply & fixing in repair LED tube light with batten 1X9 watts LED, 230Volt energy efficient, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed.

90

-

-

... More
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed.

500

-

-

... More
Supply & fixing LED lamp/T lamp 9/10 watts complete all as specified and as directed.

200

-

-

... More
Disconnection and removing the u/s LED lamp and S&F LED lamp 12 watts complete all as specified and directed.

270

-

-

... More
Supply & fixing in repair LED inverter lamp 12 watt, 4 hrs backup time, cool white at mains supply and 450 lumens at backup 230 volt, 50 hz, all as specified and directed.

225

-

-

... More
Supply & fixing as in repair batten Led 22 w inverter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 more than, driver efficiency ≥ 85%, operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by engineer-in-charge.

120

-

-

... More
Supply & fixing energy efficient Integral type 25W LED Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted on MCPCB and testing compelte all as specified and directed.

30

-

-

... More
Supply & fixing GI bracket of size 32mm dia from the pole / building and M&L for street light bracket made out of 25 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to building complete all as specified and as directed.

30

-

-

... More
Supply and Fixing SPN AFDD 16A/32A/40A offering protections for overload, short circuit, Residual current characterisitics TYPE A, Over Voltage protection above 270 AC plus minus 5% & series parallel arc fault. AFDD must be dual test button for AFDD and Earth leakage functions along with single diagnostic LED with blinking patterns for continuous ON, Series Arc, Parallel arc and overvoltage protection.

10

-

-

... More
Supply and Fixing Portable current residual device (PRCD) 16 A 30mA Euro II all as specified and as directed by Engr in charge.

25

-

-

... More
Earthing with GI earth plate electrode 60cm x 60cm x 6.0 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth wire of 4.0 mm dia by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with50mm thick with 6mm dia MS bars complete all as shown in SSR Pt - 1 electrical plate No 3. Note : Qoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc. complete all as specified and directed by Engg-In-Charge.

30

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.

135

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.

120

-

-

... More
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.

15

-

-

... More
Supply and Fixing galvanised iron tubing 15 mm bore, ‘medium grade’, ISI marked, galvanized with all fittings and fixed complete laid in trenches or walls and ceilings or laid in floors, complete all as specified.

350

-

-

... More
Supply and Fixing galvanised iron tubing 20 mm bore, ‘medium grade’, ISI marked, galvanized with all fittings and fixed complete laid in trenches or walls and ceilings or laid in floors, complete all as specified.

800

-

-

... More
Supply and Fixing galvanised iron tubing 25 mm bore, ‘medium grade’, ISI marked, galvanized with all fittings and fixed complete laid in trenches or walls and ceilings or laid in floors, complete all as specified.

280

-

-

... More
Taking up or down steel tubing and connections,15 mm bore complete all as specified and as directed.

350

-

-

... More
Taking up or down steel tubing and connections, 20 mm bore complete all as specified and as directed.

800

-

-

... More
Taking up or down steel tubing and connections,25 mm bore complete all as specified and as directed.

280

-

-

... More
Cutting existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (Each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.

45

-

-

... More
Cutting existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.

50

-

-

... More
Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.

25

-

-

... More
Gun-metal, globe or gate valves, ISI marked with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia, in repairs, complete all as specified.

25

-

-

... More
Gun-metal, globe or gate valves, ISI marked with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia, , complete all as specified.

40

-

-

... More
Gun-metal, globe or gate valves, ISI marked with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia, in repairs, complete all as specified.

25

-

-

... More
Supply & fixing in repair 15mm Bib taps, Cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.

45

-

-

... More
Arresting of water leakage from existing pipe line in position from GI pipe of size 15mm bore ,including excavation through Men/Mechnical power ,cutting, threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note :- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.

40

-

-

... More
Arresting of water leakage from existing pipe line in position from GI pipe of size 20mm to 25mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note :- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.

40

-

-

... More
Taking down ceiling fans of 1200 to 1400mm sweep and make after disconnecting from ceiling rose, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp,rubeer reels with nut, bolt split pin, and shaft, sleeves, rewinding, testing, rehanging and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for separately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain the signatures of user after satisfactory complition of work

600

-

-

... More
Taking down exhaust fans of any sweep and make after disconnecting, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp, nut, bolt and split pin, and shaft. sleeves, rewinding, testing, refixing and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain thre signatures of user after satisfactory complition of work

50

-

-

... More
Taking down Wall mounted/Pedestal fans of Sweep 300 to 450mm, 230 volts of any make & size after disconnecting, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp, nut, bolt and split pin, and shaft. sleeves, rewinding, testing, refixing and making connection complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain the signatures of user after satisfactory complition of work

10

-

-

... More
M&L replacement of unserviceable capacitor 2.5/3.15 mfd provided with new capacitor oil type 2.5/3.15 mfd suitable for 440 volt AC Complete all as specified and as directed by Engineer-in-charge.

350

-

-

... More
All as item No 73 here in above but of Capacity 4.15 MFD, AC 440 volts

22

-

-

... More
M&L rewinding to ceiling fan motor of 1200 to 1400mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves & paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor cable of size 23/.0076 upto connector block complete all as specified and as directed by Engineer-in-charge. Note :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account

600

-

-

... More
All as item No 75 here in above but for Exhaust fan 225 to 300mm sweep.

25

-

-

... More
All as item No 75 here in above but for Exhaust fan 350 t0 450mm sweep.

20

-

-

... More
All as item No 75 here in above but for Pedestal / Wall mounted fan upto 450mm sweep.

15

-

-

... More
Supply only Ball bearing suitable for celing fans of any sweep.

300

-

-

... More
Supply only gun metal bush suitable for celing fans of any sweep.

250

-

-

... More
Supply only Mild steel shaft suitable for celing fans of any sweep.

85

-

-

... More
Supply only ball bearing suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mountin fan

50

-

-

... More
Supply only gun metal bush suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting

30

-

-

... More
Supply only mild steel shaft suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan

18

-

-

... More
M&L for replacement of unserviceable rubber reels with new suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.

180

-

-

... More
M&L for replacement of unserviceable rusted MS rod up to 3 feet including clamp, nut, bolt, washer & split pin suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.

75

-

-

... More
M&L for replacement of unserviceable PVC canopy suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
M&L for replacement of unserviceable fan blades (set of three blades) suitable for 1200/1400/1500mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Preparation surfaces, cleaning thoroughly with kerosene oil ceiling fans 1200mm/1400mm/1500mm sweep to remove only dust and any type of spots and painted with synthetic enamel paint of existing colour with help of spray gun machine, including writing MES No, complete all as specified and as directed by Engineer-in-charge.

45

-

-

... More
M&L lathe work for taking out bush from the lower body part of ceiling/Exhaust fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft complete all as specified and as directed by Engineer-in-charge. Note : - Supply only Bearing shall be measured and paid separately under respective item of this Schedule.

27

-

-

... More
Disconnecting & taking down unserviceable geyser of 25/50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares , including replacement of required number of stainless steel screws, nuts & bolts,assembling the the same after repair work and fixing in its original place, connecting to water mains and electric supply, testing after repairs, complete all as specified and as directed by Engineer-in-charge. Note :spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ.

25

-

-

... More
Replacement of unserviceable Geyser thermostat switch any type/size with new thermostat switch ISI marked of range 0-100 degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc complete and all as specified

22

-

-

... More
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
All as per above item No 93 here-in-before but 50 litre capacity.

2

-

-

... More
S&F replacement of unserviceable Stain less steel inner tank of 25 litre capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.

20

-

-

... More
All as per above item No 95 here-in-before but 50 ltr capacity.

2

-

-

... More
Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 2000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.

22

-

-

... More
All as per above item No 97 here-in-before but 1500 watt.

15

-

-

... More
Replacement of unserviceable Safety valve

30

-

-

... More
Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified

20

-

-

... More
Replacement of unserviceable 23 to 30 cm long ,10 mm bore C.P Connection with brass union

25

-

-

... More
Replacement of unserviceable Gun metal non return valve ,15 mm bore

10

-

-

... More
Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends for hot and cold water fixed to GI Pipe complete and all as specified.

60

-

-

... More
Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litre.

8

-

-

... More
Replacement of unserviceable Apparatus plate for Syphon Assy 50 litre

2

-

-

... More
Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.

6

-

-

... More
Replacement of 3-Pin plug top, 16 Amp, 230volt AC

12

-

-

... More
Replacement of Rubber 'O' ring /gasket for 25 ltrs

10

-

-

... More
Material & labour for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.

20

-

-

... More
Material & labour for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing in repair of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for Geysers of any capacity complete all as specified and as directed by Engineer-in-Charge .

70

-

-

... More
Cutting chasing in brick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge

20

-

-

... More
Supply and fixing 15mm bore stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
Supply and fixing 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
Disconnecting, opening and taking out unserviceable sealed compressor of water cooler of capacity 150/180 litres and replaced with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leakage etc complete all as specified and as directed by Engineer-in-charge. Make : SRI-RAM/ TAKAM SHAH/ KIRLOSKER .

3

-

-

... More
All as per above item No 115 hereinbefore but water cooler of capacity 40/80 litres. Note for item No 115 & 116: (i) Contractor shall produce original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured &paid separately under respective item of BOQ.

1

-

-

... More
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of150 litres capacity complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
All as per above item No 117 here-in-before but water cooler of capacity 40/80 litres

1

-

-

... More
Supply and fixing internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing in repair of unserviceable starting relay assembly with new starting relay assembly suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge

4

-

-

... More
All as per above item No 120 hereinbefore but water cooler of capacity 40/80 liter

1

-

-

... More
Supply and fixing in repair of unserviceable over load protector with new over load protector suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
All as per above item No 122 here-in-before but water cooler of capacity 40/80 litre

1

-

-

... More
Supply and fixing in repair of unserviceable fan motor with new fan motor suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
All as per above item No 124 hereinbefore but water cooler of capacity 40/80 liter

1

-

-

... More
Replacement to unserviceable Condenser unit with new condenser unit of existing make and model suitable for water cooler of capacity 150/180 liters, complate all as specified and as directed.

1

-

-

... More
All as per above item No 126 here in before but water cooler of capacity 40/80Liters.

1

-

-

... More
Supply and fixing in repair 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces and bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine and writing SM / MES No in 5cm height complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
All as per above item No 129 here-in-before but water cooler of capacity 40/80 liter

1

-

-

... More
Supply and fixing in repair of unserviceable thermo-state switch with new thermo-state switch suitable for water cooler any capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Disconnecting & opening refrigerator of capacity 180/210/320 litre and taking out unserviceable sealed compressor and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :SRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .

1

-

-

... More
Recharging of gas R-10/12/134A in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
Replacement of freezer door plastic with tension spring as per existing model suitable 160/210 litre cap.

1

-

-

... More
Replacement of Door liner ( Plastic ) for upto 310 liter capacity

1

-

-

... More
Replacement of Door magnetic gaskest for upto 310 litre cap.

1

-

-

... More
Replacement of Relay box type for any cap.

1

-

-

... More
S&F replacement of unserviceable over load protector with new over load protector suitable for refrigerator 165 to 310 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
Disconnection and removing the unserviceable Split AC Outdoor & Indoor Unit/ window type of Capacity 1.5 to 4 Ton capacity from the existing position carefully for finding of the defects and to replace the unserviceable spare parts such as Compressor, Condensor fan mtor, condensor coil, suction & discharge valves, mother plates including carry out leak detection test, Gas charging, servicing such as cleaning and removing the dust particles accumulated in the unit and filters carefully and washing the cooling unit and Indoor unit with water and refixing the same in its original position complete including connecting up of the Copper Tubes and cable connections, testing and commissioning complete all as specified and as directed by Engineer in charge. (i) Cost of spares such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates, leak detection test, Gas charging shall be measured and paid separately under the respective Schedule. (ii) Makes & Specifications of the spare parts for replacement should be identical equivalent to the spares suitable for existing ACs.

36

-

-

... More
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 1.5 Ton Single Phase for Split Type ACs complete all as specified and directed by Engineer in charge. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier

10

-

-

... More
Supply only indoor sealed Compressor Unit of Capacity 1.5 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier

15

-

-

... More
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 2 Ton Single Phase for Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier

2

-

-

... More
Supply only indoor sealed Compressor Unit of Capacity 2.0 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier

1

-

-

... More
Supply only sealed Compressor Unit of Capacity 4 Ton Single Phase for Standing Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier

2

-

-

... More
Supply only Condensor Fan Motor 230 Volt suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

18

-

-

... More
Supply only Condensor Fan Motor 230 Volt suitable for 2 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG:/Hitachi/Voltas/Blue Star

2

-

-

... More
Supply only Fan Motor 230 Volt suitable for window type AC of 1.5 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

10

-

-

... More
Supply only Fan Motor 230 Volt suitable for window type AC of 2.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

1

-

-

... More
Supply only Fan Motor 230 Volt suitable for Standing Split type AC of 4.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

1

-

-

... More
Supply only blower motor suitable for Split type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

12

-

-

... More
Supply only blower motor suitable for window type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

6

-

-

... More
Supply only blower motor suitable for Standing Split type AC of 4 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star

1

-

-

... More
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

8

-

-

... More
Supply only Condensor Coil Unit made out of Copper tubing suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

2

-

-

... More
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.

8

-

-

... More
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 2 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.

1

-

-

... More
Supply only Condensor Coil Unit made out of Copper tubing suitable for 4 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

1

-

-

... More
Supply only PCB/ Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2/4 Ton Indoor Unit of Split Type Air Conditioning complete all as directed.

27

-

-

... More
Replacement of broken Fan Blade from the Outdoor units of Split AC Unit 1.5 / 2 /4 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit.

22

-

-

... More
Replacement of running/starting capacitors from the Outdoor units of Split Type AC Unit 1.5/2/4 Ton Capacity and S&F New Capacitors of capacity 36/46/50 MFD, 230 Volts, ISI Marked.

42

-

-

... More
Replacement of Display Unit for indicating Temperature, Temperature Sensor for 1.5/2/4 Ton Split AC Unit complete all as directed. Make :- LG/Hitachi/Voltas

18

-

-

... More
Supply and Charge Refrigerant (R-22)/410a/407C Suitable for existing 1.5 Ton Capacity Split / Window type air conditioning unit complete all as directed.

27

-

-

... More
Supply and Charge Refrigerant (R-22)/410a suitable for existing 2 Ton Capacity Split / Window type air conditioning unit complete all as directed.

2

-

-

... More
Supply and Charge Refrigerant (R-22)/410a suitable for existing 4 Ton Capacity Standing Split type air conditioning unit complete all as directed.

2

-

-

... More
Replacement of Standard Flexible PVC Drain Pipe of dia 25mm for capacity 1.5 ton, 2.0 ton & 4 Ton capacity complete all as directed.

180

-

-

... More
Disconnection and removing the old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia and connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer in charge.

150

-

-

... More
All as per Item No 166 here in above but size 1/4" dia

150

-

-

... More
Supply and fix Suction Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

12

-

-

... More
Supply and fix Suction Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

1

-

-

... More
Supply and fix Suction Valve made of Brass suitable for 4 Ton Outdoor Unit of Standing Split Type Air Conditioning complete all as directed.

1

-

-

... More
Supply and fix Discharge Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

12

-

-

... More
Supply and fix Discharge Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.

1

-

-

... More
Supply and fix Discharge Valve made of Brass suitable for 4 Ton Outdoor Unit of Standing Split Type Air Conditioning complete all as directed.

1

-

-

... More
Disconnection and Removing the defective / damaged Industrial Plug & Socket Board and supply & fix Industrial Plug & Socket controlled by 01 No 15/16 Amp Single Pole ISI Marked in and including sheet metal enclosure suitable for 1.5/2 Ton capacity

15

-

-

... More
Disconnection and Removing the Cable connections and Copper Pipe alongwith all connected items carefully from the existing indoor and out door units and Pumpdown the refriegerant from Outdoor Unit of tonnage 1.5/2/4 Ton including stabilizer from the existing positions and shifting the AC unit at new place and refixing the outdoor and indoor units with necessary copper tubing including topping up of gas and connecting stabilzer etc for its proper functioning complete all as directed.

15

-

-

... More
Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete. Note :- 1 The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit. 2 The cost of refrigerant will be measured and paid separately under rhe respective Schedule A Item.

15

-

-

... More
Disconnection and removing the unserviceable / burnt out Copper Cable between Indoor & Outdoor Unit and S&F PVC Insulated, PVC Sheathed, Multistranded Copper Cable 3 Core 4 Sqmm, ISI Marked, 1100 volts Grade and connecting to the unit along with necessary fixing materials complete.

240

-

-

... More
Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, flame retardant low smoke and low halogen (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty PVC concealed conduit and its fittings, ISI marked, PVC junction boxes, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylam sheet including flame retardant low smoke and low halogen (FRLSH) PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly for One light point controlled by one switch complete all as specified, for the following: - Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item.

400

-

-

... More
All as per item No 178 above but One ceiling /exhaust fan point controlled by one, one way 5 Amps switch.

60

-

-

... More
All as per item No 178 above but One 3 pin socket outlet 5 Amps on independent board.

90

-

-

... More
All as per item No 178 above but One 3 pin socket outlet 5 Amps on same board.

55

-

-

... More
All as per item No 178 above but One light point controled by two way 5 Amps switches.

15

-

-

... More
All as per item No 178 above but One bell/ buzzer point controled by one bell push on same board with other switches or on independent board.

25

-

-

... More
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 2.5 Sqmm (nominal area), single core, FRLSH, flame retardant low smoke and low halogen PVC insulated and unsheathed cable ISI 694 marked TEC and FIA approved in and including heavy duty PVC concealed conduit and its fittings, ISI marked,for one 3 pin 15 Amp socket outlet on independent board, mild steel terminal sunken boxes ( suitable for switches / sockets with earth dolly ) duly painted internally and externally with two coats of anti-corrosive paint over a coat of primer, covered with and including 3mm thick bakelite for suitable sizes Hylam sheet, including FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area) 1100 volts grade, single core cable as earth continuity conductor to common earth and connected to earth dolly for Switch 15Amps flush type controlled by one switch 15 Amps complete all as specified and directed. Note :- Rates for cutting/chasing in wall etc deemed to be included in quoted rate of this item.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.