Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693661_1Tender No
GE(AF)/CHD/T-51/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
One three pin 6 Amp switch socket outlet on the same board with other switches.
100
-
-
... More
One light point controlled by 2 No. 2-way switches.
20
-
-
... More
One bell point controlled by bell push.
20
-
-
... More
All as per item No 1.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete.
Note for item No. 1.01 to 1.05 & 2.00 : Sunken box and cover plates required shall be measured and paid separately under respective item.
100
-
-
... More
M&L for point wiring using stranded copper conductor FRLSH cable of size 1.5 sqmm, PVC insulated unsheathed complete in existing concealed/surface conduit with new sunken terminal boxes and with new 3 mm thick hylam sheet for mounting of switches, sockets, fan regulators etc with screws and 1.5 sqmm PVC insulated stranded copper conductor FRLSH cable as continues earth wire connected to common earth dolly incl taking down old copper/aluminium point wiring (light, fan, socket or power) from existing surface/concealed conduits, casing/caping etc and making good disturbed surfaces of walls, floors etc for the following complete all as specified and directed :-
-
-
-
... More
One light point controlled by one switch/ fan point controlled by one switch .
720
-
-
... More
One three pin 6 amp socket outlet multipurpose on independent board.
180
-
-
... More
One three pin 6 Amp switch socket outlet on the same board with other switches.
135
-
-
... More
One light point controlled by 2 No. 2-way switches.
45
-
-
... More
One bell point controlled by bell push.
45
-
-
... More
All as per item No 3.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete.
135
-
-
... More
S&F in repairs modular switch 1 way 6 A, 1 module all as specified and directed.
582
-
-
... More
S&F in repairs modular switch 2 way 6 A, 1 module all as specified and directed.
40
-
-
... More
S&F in repairs modular bell push switch 1 way 6 A, 1 module all as specified and directed.
20
-
-
... More
S&F in repairs modular socket outlet, 2/ 3 pins combined, 6 Amps, 2 module, 230 volts all as specified and directed.
182
-
-
... More
S&F in repairs modular switch 1 way 16 A, 1 module all as specified and directed.
100
-
-
... More
S&F in repairs modular socket outlet, 6/ 16 Amps, 2/3 pin combined, 230 volts, 2 module all as specified and directed.
100
-
-
... More
S&F in repairs modular type electronic ceiling fan step regulator, 120W, 1 module for 1200/ 1400mm sweep ceiling fan complete all as specified and directed.
140
-
-
... More
S&F in replacement of switch piano type, flush type, single pole, one way, 6 Amps complete all as specified and directed.
1035
-
-
... More
S&F in replacement of switch piano type, flush type, single pole, two way, 6 Amps complete all as specified and directed.
90
-
-
... More
S&F in replacement bell push switch flush type, single pole, one way, 6 Amps complete all as specified and directed.
45
-
-
... More
S&F in replacement of socket outlet flush type 2/ 3 pins, 6 Amps multipurpose complete all as specified and directed.
315
-
-
... More
S&F in replacement of switch piano type, flush type, single pole, one way, 16 Amps complete all as specified and directed.
135
-
-
... More
S&F in replacement of socket outlet, flush type, multi purpose 3 pin, 6 Amps & 16 Amps, 230 volts complete all as specified and directed.
135
-
-
... More
S&F in replacement ceiling fan regulators, step type, electronic for 1200/ 1400mm sweep complete all as specified and directed.
90
-
-
... More
M&L for submain wiring complete with two runs of 4.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 4.0 sqmm multi-stranded cable and one run of 4.0sqmm cable as earth continuity conductor shall be considered as one unit length.
350
-
-
... More
M&L for submain wiring complete with two runs of 6.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 6.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 6.0 sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductor shall be considered as one unit length.
975
-
-
... More
S&F in replacement MCB SP 240 volts 6 to 32 Amps, 10KA, 'B' curve type all as specified and directed.
290
-
-
... More
S&F in replacement MCB SPN 240 volts 40 to 63 Amps, 10KA, ‘B’ curve complete all as specified and directed.
65
-
-
... More
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 12 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
20
-
-
... More
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 8 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
45
-
-
... More
S&F in replacement 04 feet 18 watt LED light fitting, 220V, AC decorative box type with driver holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
320
-
-
... More
S&F in replacement 02 feet 10 watt LED light fitting mirror type, 220V, AC decorative box type with driver holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
175
-
-
... More
S&F in repairs LED light fitting 1 x 9W/ 1 x 10W bulk head luminaires including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
110
-
-
... More
S&F in repairs City-1/ City-2 wall mounted fittings with ABS housing and clear polycarbonate cover including retrofit LED bulb 9 watt and provision of 0.5 sqmm 3 core flexible copper conductor cable from connector/ ceiling rose to fitting complete all as specified and directed.
175
-
-
... More
S&F in repairs ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals, complete all as specified and directed.
618
-
-
... More
S&F in replacement bell Ding Dong AC 230 volts single pole complete all as specified and directed.
85
-
-
... More
S&F in replacement concealed type flush mounted GI sheet metal box 18 gauge thickness suitable for mounting modular switch/ sockets complete with fixing plate and cover plate with frame, with earthing terminal and good quality thread including making good the disturbed surfaces complete all as directed for the following:-
-
-
-
... More
For two module
41
-
-
... More
For three module
173
-
-
... More
For four module
10
-
-
... More
For six module
18
-
-
... More
For eight module
64
-
-
... More
S&F Modular white cover blanking plate complete all as specified and directed.
10
-
-
... More
M&L in replacement for earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using earth lead wire 4.0mm connected by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized steel pipe 40mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber shall be constructed 500mm away from the edge of earth pit, pit cover of precast RCC (1:1½:3), type B-1, 80mm thick reinforced XPM of weight not less than 4 Kg/ Sqm. complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion complete all as specified and directed. Notes:- (i) The unit rate includes galvanised Iron strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/ test point. (ii) Old earthing may have been burried down to a depth of exceeding 2.25m below ground level. No extra payment will be made if excavation is done beyond 2.25m depth to retrieve the old earthing.
31
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%