Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date11 Jan 2025
Closing Date1 Feb 2025
Tender Amount₹ 18,00,000
Costs
EMD
₹ 36,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692688_1Tender No
GE(AF)/CHD/T-50/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in replacement Gear Key of EOT crane complete all as specified and directed.
2
-
-
... More
S&F in replacement Coupling Kit of EOT crane complete all as specified and directed.
2
-
-
... More
S&F in replacement 6sqmm 4core PVC insulated and FRLS PVC round sheathed Copper conductor (Flexible) industrial cable 1100 volts conforming to IS 694 of the crane motor complete all as specified and directed.
560
-
-
... More
S&F in replacement of Carbon Bush Set 160 Amp complete all as specified and directed.
2
-
-
... More
S&F in replacement of Brake Set of EOT crane 5 ton capacity of make as per site complete all as specified and directed.
1
-
-
... More
S&F in replacement VFD Device suitable for 5 Ton EOT Crane of make: ABB
1
-
-
... More
S&F in replacement Limit Switch suitable for 5 Ton EOT Crane.
1
-
-
... More
M&L for overhauling and re-alignment of unserviceable manually operated Hanger Doors of any size/ height including replacement of defective bearing and grinding of wheels for smooth movement of doors, replacement of clamps, bolts etc. including cleaning, oiling and greasing of moveable parts and welding work complete all as specified and as directed.
4
-
-
... More
Taking out unserviceable manually operated Hanger Door Wheel with pin and supply, fixing and testing hanger door wheel with pin in existing size suitable for hanger door and model complete all as specified and as directed.
8
-
-
... More
M&L for overhauling and re-alignment of unserviceable Door Rolling Shutters of area n.exc. 12 Sqm including replacement of defective bearing and grinding of wheels for smooth movement of doors, replacement of clamps, bolts etc. including cleaning, oiling and greasing of moveable parts and welding work complete all as specified and as directed.
8
-
-
... More
Supply, installation, testing and commissioning DOL Starter in sheet steel enclosure single phase starter type MK-I, single phase DOL, 6-10 A, 360 volts including taking down existing starter of any type & capacity complete all as specified and directed. MAKE: L&T/ BCH/ SIEMENS/ C&S.
1
-
-
... More
Supply, installation, testing and commissioning Reverse Starter 3 phase, 415 volts, 20/ 15HP/ KW, relay rating 23-32 Amp, SS enclosure grouting in wall including making all incoming & outgoing connection and testing in full load including taking down existing reverse starter of any type & capacity from hanger door complete all as specified and directed. MAKE: C&S/ BCH/ SIEMENS/ L&T/ HAVELLS.
1
-
-
... More
M&L for attending Hanger Motorized Doors Complaints of any nature pertaining to electrical & mechanical problem of hanger motorized door like long travel, all motion motors, control panel, pendent control box, MCB's contactors, steel wire rope, control cable, push greasing of rope, loose nut bolts etc. and rectification of the fault and replacing the unserviceable items as per site requirement including making connection and testing after completion of Job complete all as specified and directed.
2
-
-
... More
Taking out unserviceable Steel Wire Rope of any size from hangar door and supply, fixing, testing & commissioning steel wire rope multi stranded 6/ 19 center fiber core, 6 to 8mm dia complete all as specified and directed. Make:- Usha Martin/ MAHADEV or equivalent as approved by GE.
60
-
-
... More
Taking out unserviceable Steel Wire Rope of any size from hangar door and supply fixing testing & commissioning steel wire rope multi stranded 6/ 19 center fiber core, 10 to 12mm dia complete all as specified and directed. Make:- Usha Martin/ MAHADEV or equivalent as approved by GE.
60
-
-
... More
Taking out old unserviceable Ball Bearing of any size and supply and fixing of ball bearing (Hanger Door) 6308 ZZ/ as per existing complete all as specified and directed.
5
-
-
... More
Taking out old burnt out unserviceable Motor 3 HP capacity and transporting to workshop to facilitate the repair work and carrying out repair work as under:-
(i) Strip opening of the burnt stator of 3 HP induction motor and taking out the burnt copper wire from stator.
(ii) Cleaning of the stator slots and removing the unwanted deposit in the stator.
(iii) M&L for rewinding of the motor with standard gauge super enameled copper wire and varnishing the same after rewinding including insulating materials etc.
(iv) Assembling of the motor and transporting to the camp site for fixing in the door mechanism.
(v) Testing for same for its operation to the entire satisfaction of Engineer-in-Charge.
2
-
-
... More
All as per item No. 19.00 above but for 5 HP capacity.
4
-
-
... More
All as per item No. 19.00 above but for 7.5 HP capacity.
6
-
-
... More
M&L for comprehensive systematic maintenance and annual inspection service of Fire Alarm System to provide routine maintenance, examination, service according to recommended schedule of maintenance/ service by the manufacturer in working hrs (i.e. Monday to Friday from 0900 to 1700 Hrs) except scheduled holidays to furnish the necessary parts and cleaning material including the replacement of any defected parts of misc nature and ensure overall serviceability of the fire alarm system including repair/ maintenance of the following parts of the system in addition to attend for annual government inspection complete all as specified and directed.
2
-
-
... More
M&L opening and servicing of Panel 8 Zone including repair/ replacement and updation of electronic components including replacement of battery set wiring, nuts bolts, switch, sockets etc. wherever required complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
M&L for complete servicing with necessary repair/ replacement of MCP and Hooter complete all as specified and directed.
5
-
-
... More
S&F in replacement microprocessor based 1 loop capacity networkable analogue addressable type Fire Alarm Control Panel with 80 character LCD display, loop shall have a capacity of 318 analog addressable devices in one loop. Four access levels, capabale of taking Flash scan devices (like detectors, LCP's, hooters, control modules, monitor modules, fault isolation, response indicators, audio visual signals central processing units, complete with LCD display, zone indicating LED's having multiple access levels), flash EPROM sufficient numbers of programmable relay controls for controlling AHu's, pressurization fans, ventilation fans, monitoring of fire hydrants pump, 240 volts AC power supply, automatic battery charger, sealed maintaince free lead acid battery - 02 Nos of cap 12 volts 180 AH sufficient for 24 hours normal workiing and then be capable of operating the system for 2 hours during an emergency conditions as required. (UL 9th Edition approved) Make : Notifer by Honeywell, Ravel, JCI/GST.
1
-
-
... More
S&F in replacement microprocessor based 2 loop capacity networkable analogue addressable type Fire Alarm Control Panel with 80 character LCD display, loop shall have a capacity of 318 analog addressable devices in one loop. Four access levels, capabale of taking Flash scan devices (like detectors, LCP's, hooters, control modules, monitor modules, fault isolation, response indicators, audio visual signals central processing units, complete with LCD display, zone indicating LED's having multiple access levels), flash EPROM sufficient numbers of programmable relay controls for controlling AHu's, pressurization fans, ventilation fans, monitoring of fire hydrants pump, 240 volts AC power supply, automatic battery charger, sealed maintaince free lead acid battery - 02 Nos of cap 12 volts 180 AH sufficient for 24 hours normal workiing and then be capable of operating the system for 2 hours during an emergency conditions as required. (UL 9th Edition approved) Make : Notifer by Honeywell, Ravel, JCI/GST.
1
-
-
... More
S&F in replacement of automatic floating sensitivity type analog addressable acclimate photo thermal Smoke and Heat Detector with mounting base LED , address switch from 01-159, to programme the detectors, complete as required (in changing environment area) Make : Model No FAPT-851(A) of Notifier by Honeywell or equivalent model of Ravel/GST/JCI
140
-
-
... More
S&F in replacement Sounder cum Strobe at respective places. Make : Notifier by Honeywell, Ravel, JCI, GST
4
-
-
... More
S & F in replacement of 2 core 1.5 sqmm FRLS copper cable 1100 Volts grade in concealed with copper jointing materials and all accessories required drawn and through and including 20mm dia stove enamelled MS conduit (ISI marked) complete all as specified
600
-
-
... More
S&F in replacement of single ended reflector type addressable Beam Smoke Detector with monitor module 4 manual and 2 acclimate sensitivity setting address switch to programme the detectors including necessary power, communication wiring, mounting accessories for integrating with main fire alaram control panel complete as required. Make : Notifier by honeywell/ Ravel/JCI
3
-
-
... More
S&F in replacement addressable type Fault Isolator Module for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement base Model : Notifier by Honeywell or equivalent model of Ravel, JCI/GST
3
-
-
... More
S&F in replacement addressable Control Input Module for hooters/ sounders / strobes etc Make : Notifier by Honeywell or equivalent model of Ravel/ JCI/GST
2
-
-
... More
S&F in replacement addressable Control Output Module for hooters/ sounders / strobes etc Make : Notifier by Honeywell or equivalent model of Ravel/ JCI/GST
4
-
-
... More
S&F in replacement Response Indicator having twin LEDs for mounting of false ceiling/ wall at the entries of the cabin for indicating the operational of detectors in the above false ceiling/wall at the entries of the cabin for indicating the operation of detectors in the above false ceiling below the false flooring detectors etc as required Make : Notifier by honeywell/ Ravel/ JCI
5
-
-
... More
M&L for visiting and labour charges once in three months including inspecting all the smoke detectors, MCP, hooters including general maintenance like fitting/ tightening of connections and clearing all issues if any for un-interrupted working of the fire alarm system complete all as specified and directed by Engineer-in-Charge.
Note: The contractor shall replace of spares/ components free of cost related to the normal wear and tear and other minor electrical/ electronic or mechanical parts as required at the time of inspection for smooth functioning of system all as specified and directed by Engineer-in- Charge.
2
-
-
... More
Supply, install, connecting & commissioning in replacement Battery 12 volts DC 180 AH 25 plates, including disconnecting & taking out old & depositing in MES store yard, complete all as specified and directed. Make: Amaron/ TATA Green/ Standard.
3
-
-
... More
M&L for complete servicing of Centrifugal Fire Pump of fire hydrant system electrically operated horizontal suction centrifugal type of discharge 2280 LPM at 70 meter head electrically operated 415 volts, 3 Phase, 50 Hz by performing the servicing including taking out coupling with pull hook, loosening the bolts and taking out rotor assembly from pump body, dismantling the impeller after measuring axel and reduced run out of rotor, cleaning of impeller guide after scraping off and rusting out in inner and outer surface of impeller, greasing to bearing gland, replacement of water seal pipe, oil ring, cleaning of bearing with gasoline etc, assembly of complete engine after complete servicing and filling hole with oil after checking crank flexibility, adding lubrications to required parts and testing the pump for trouble free operation complete including painting of pumping set with 2 coats of super enameled paint of required shade at site complete all as specified and directed. Notes: (i) Any damage to engine will be the responsibility of contractor.
(ii) Cost of bearings, seals and caps required for servicing of engine shall be deemed to be included in the quoted rates.
1
-
-
... More
All as per item No. 37.00 above but Engine Driven
1
-
-
... More
All as per item No. 37.00 above but Jockey Pump horizontal end suction centrifugal type with discharge 180 LPM at 70 meter head operated at 440 volts 3 phase 50 Hz.
1
-
-
... More
M&L for opening of the Motor 50 HP, 440 volts, 3 phase 50 Hz Pumping Set from installation, taking out rotor with the help of puller, varnishing and replacement of teared bushes assembly of the motor and connecting with pump set, scrapping of rust and greasing material and applying 2 coats of heat resistant paint in outer casing of motor complete all as specified and directed.
1
-
-
... More
All as per item No. 40.00 above but of capacity 15 HP.
1
-
-
... More
S&F in replacement Cast Iron Strainer for 150mm dia pipe, PN10 complete all as specified and directed.
1
-
-
... More
All as per item No. 42.00 above but suitable for 100mm dia pipe.
1
-
-
... More
S&F in replacement Pressure Gauge 100mm dia 0 to 14 Kg rating complete all as specified and directed.
1
-
-
... More
S&F in replacement Branch Pipe Gun Metal 63mm Instantaneous Inlet internally threaded with 50mm bore outlet nozzle complete all as specified and directed.
1
-
-
... More
S&F in replacement 63mm dia 15m long RRL (Reinforced rubber Linned) Canvas Fire Hose type A including gun metal male and female instantaneous type coupling approved by fire authority, machine wound with GI wire and shourt gunmetal nozzle complete in all respect hose to conform to IS 636 type A and coupling to IS:903-75 (12 Nos yard hydrant and 22 Nos for wet riser system) complete all as specified and directed.
1
-
-
... More
S&F in replacement weather proof standard Hose Cabinet outdoor/ indoor type of 800mm height x 600mm width x 250mm depth, suitable for accommodating yard hydrants and hose pipes made of 18 gauge MS Sheet having central opening door frame made of 16 gauge MS sheet and 4 mm thick glass including necessary locking arrangement, painting fire red outside and brillant white inside complete all as specified and as directed
1
-
-
... More
S&F in replacement Fire Hydrant Landing Valve 80mm dia , flanged inlet with 63mm female instantaneous outlet of gun metal complete with blank caps , chain conforming to IS 5290-1977 and ISI marked (6 Nos for yard hydrant and 11 Nos for wet riser system) complete all as specified and directed.
1
-
-
... More
S&F in replacement Cast Iron Non Return Butterfly Valve of dia 100mm, PN 1.0, complete all as specified and directed.
1
-
-
... More
S&F in replacement 100mm dia Cast Iron Sluice Valve class PN 1.6 with flanged ends complete with nuts and bolts complete all as specified and directed.
1
-
-
... More
S&F in replacement Pressure Switch universal type 80mm dia complete all as specified and directed.
1
-
-
... More
S&F in replacement Flow Switch 80mm dia for fire hydrant complete all as specified and directed.
1
-
-
... More
M&L for repair and complete servicing of the main panel of electrically operated hanger doors located at 44 Sqn (3 Nos doors at both right & left side) complete including replacement of components as required at site complete all as specified and directed. Note: Supply only of components shall be measured and paid for separately.
1
-
-
... More
Supply only the following components for main panel of electrically operated hanger door:-
-
-
-
... More
MNX A2 Contactor.
8
-
-
... More
Power terminal 1-20.
12
-
-
... More
VMP 32 A2 relay.
1
-
-
... More
Push button for start/ stop function.
12
-
-
... More
RYB indicators
8
-
-
... More
M&L for complete wiring of the panel including harnessing and all fittings and fixtures required at site to make the panel serviceable complete all as specified and directed.
1
-
-
... More
M&L for repair and complete servicing of the main panel of electrically operated hanger doors located at 44 Sqn (13 No. doors at both front & rear side) complete including replacement of components as required at site complete all as specified and directed. Note: Supply only of components shall be measured and paid for separately.
2
-
-
... More
Supply only the following components for main panel of electrically operated hanger door:-
-
-
-
... More
VFD delta electronic inverter driver , input 3 phase 380v-480v HZ, output 3 phase 0-480V, 13A/9.9KVA, frequency range 0-600HZ, IP-20 (Model No.- VFD055E43A)
1
-
-
... More
Contactor of 7.5 HP capacity.
4
-
-
... More
Sensor for doors to and fro operation.
4
-
-
... More
Siren.
3
-
-
... More
Volt meter.
3
-
-
... More
Ammeter.
3
-
-
... More
MPCB 9-13 amp
1
-
-
... More
Starter 5 HP capacity.
2
-
-
... More
Excavation in trenches in any type of soil n. exc. 1.5m deep and n. exc. 1.5m in width and getting out including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. complete all as specified and directed.
Notes: (i) Excavation shall be done carefully to avoid damage of existing cables and protection covers.
(ii) Excavation work may be got carried out in short lengths for locating fault in underground cables at different locations.
114
-
-
... More
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers, each layer n.exc. 25mm thick in soft/ loose soil complete all as specified and directed.
65
-
-
... More
Removing excavated surplus soil to a distance n.exc. 50 mtrs and depositing where directed at a level n.exc. 1.5mtrs above the starting points complete all as spcified and directed.
49
-
-
... More
M&L for sand cushioning to cables with a layer of sand 8cm thick before laying the cable and 15cm thick punned down after laying and stretching of cable) complete all as specified. Note: Punned thickness (overall 18cm) shall be measured & paid.
34
-
-
... More
M&L old size sub Class ‘B’ Bricks for protection to cable laid flat abutting each other perpendicular to direction of cable direction complete all specified and directed.
3.68
-
-
... More
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techique and necessary machine including HDPE Pipe of up to 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
10
-
-
... More
Supply and laying in replacement 50mm bore GI Tubing Light Grade Pipe with all fitting laid in trenches, fixed to wall etc. complete all as specified and directed.
10
-
-
... More
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 50 sqmm 3½ core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed.
50
-
-
... More
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 35 sqmm 4 core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed.
230
-
-
... More
Supplying, laying in trenches/ passing through tubing/ pipes or laid under floors or through walls/ ducts etc., jointing and testing, 1100 volts grade XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, LT electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 25 sqmm 4 core, including both sides connection with and including cable lugs etc., including taking out existing unserviceable cable, complete all as specified and directed.
250
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%