Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Oct 2024
Closing Soon27 Nov 2024
Tender Amount₹ 58,00,000
Costs
EMD
₹ 1,12,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679731_1Tender No
CWE/AF CHD/CHD/T-20/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removal of surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
161
-
-
M&L for sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables as in trenches/ducts complete all as specified and as directed.
Note: Punned down thickness (overall 18cm) shall be considered for measurement and payment.
110
-
-
M&L for Factory made unreinforced precast cement concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other complete all as specified and as directed.
9568
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc complete all as specified and as directed.
650
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc complete all as specified and as directed.
750
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm 4 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc complete all as specified and as directed.
300
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc complete all as specified and as directed.
300
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 150 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc complete all as specified and as directed. Note for Item Nos 7 to 11 : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
600
-
-
Supply, installation, testing and commissioning of Factory Made LT panel board (CPRI Approved as per latest Norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated, outdoor type with double doors suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm thick CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, angle iron 50mm X 50mm X 6mm legs 04 Nos of 750 mm length for grouting in floor in cement concrete bed blocks, 1:2:4 Type B-1 (using 20mm graded stone aggregate) of suitable size with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable complete all as specified and comprising the following:- a) LT bus bar aluminum TPN 400 Amps, 4 strips sleeve insulated mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 250 Amps, 35 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 100 Amps, 25 KA, 50 Hz, 415 Volts = 03 Nos (d) MCCB AC, 4 pole, 63 Amps, 25 KA, 50 Hz, 415 Volts = 01 No (e) MCB AC, SPN 32 Amps, 10 KA, 50 Hz, 240 Volts = 01 No.
(f) Digital Amps meter 96 x 96 mm flush mounting type with CT’s 250/5 A and selector switch= 01 Set. (g) Digital Voltmeter 0-500 volts 96 x 96 mm flush mounting type with selector switch =1 Set. (h) Phase indicator lamps RYB =01 Set (j) Internal connections with copper cable of suitable size with SP MCB in each circuit. (k) Danger Notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals - 02 Nos
1
-
-
Supply, installation, testing and commissioning of Factory Made LT panel board (CPRI Approved as per latest Norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated , indoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 2 mm thick CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, angle iron 50mm X 50mm X 6mm legs 04 Nos of 600 mm length for grouting in floor in cement concrete bed blocks 1:2:4 Type B-1 (using 20mm graded stone aggregate) of suitable size with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable complete all as specified and comprising the following:- a) LT bus bar aluminum TPN 400 Amps, 4 strips sleeve insulated mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 250 Amps, 35 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 100 Amps, 25 KA, 50 Hz, 415 Volts seting = 03 Nos (d) MCCB AC, 4 pole, 63 Amps, 25 KA, 50 Hz, 415 Volts = 01 No (e) MCB AC, SPN 32 Amps, 10 KA, 50 Hz, 240 Volts = 01 No. (f) Digital Amps meter 96 x 96 mm flush mounting type with CT’s 250/5 A and selector switch= 01 Set.
(g) Digital Voltmeter 0-500 volts 96 x 96 mm flush mounting type with selector switch =1 Set.
(h) Phase indicator lamps RYB =01 Set (j) Internal connections with copper cable of suitable size with SP MCB in each circuit. (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals - 02 Nos
2
-
-
Supply, installation, testing and commissioning of Factory Made LT panel board (CPRI Approved as per latest Norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated , outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm thick CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, angle iron 50mm X 50mm X 6mm legs 04 Nos of 750 mm length for grouting in floor in cement concrete bed blocks 1:2:4 Type B-1 (usingg 20mm graded stone aggregate) of suitable size with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable complete all as specified and comprising the following:- a) LT bus bar aluminum TPN 600 Amps, 4 strips sleeve insulated mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 400 Amps, 50 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 250 Amps, 25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 03 Nos (d) MCB AC, SPN 32 Amps, 10 KA, 50 Hz, 240 Volts = 01 No. (e) Digital Amps meter 96 x 96 mm flush mounting type with CT’s 400/5 A and selector switch= 01 Set. (f) Digital Voltmeter 0-500 volts 96 x 96 mm flush mounting type with selector switch =1 Set. (g) Phase indicator lamps RYB =01 Set (h) Internal connections with copper cable of suitable size with SP MCB in each circuit. (j) Danger Notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals - 02 Nos Note for Item Nos 12 to 14. Drgs of panels shall be approved by the GE before placement of Order.
1
-
-
S&F Factory made sheet Metal enclosure suitable for MCCB as incoming VTPN 415 volts (Double Doors) and outgoing MCBs, 4 ways with 200 Amp bus bar with IP43 protection complete in all aspects incomer MCCB FP 100 amps 25 KA 415 volts - 01 No and outgoing MCBs SP 6 to 32 amps 'B' curve - 12 Nos complete all as specified and as directed
12
-
-
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron earth lead wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 15mm dia bore, watering pipe 20 mm bore GI light grade pipe with funnel & wire mesh, with and including including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, as in repair/replacement complete all as specified and as directed.
Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include GI strip and protection pipe of length 7.5m, GI pipe beyond 7.5m length required at site shall be measured and paid separately.
(iv) Earth resistance should be less than 2 Ohm. In case the test results are not found below 2 Ohm, complete earthing will be redone without any extra cost to Govt.
10
-
-
S&F GI powder coated perforated type cable tray 14 SWG (2 mm thick) as per IS:2629/4750, with standard slots of size 200 mm x100 mm with cover of suitable size complete all as specified and as directed.
125
-
-
M&L for point wiring with 1.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through in existing conduits including new sunken terminal boxes duly epoxy painted for mounting modular switch/sockets etc with and including 1.5 Sqmm multi stranded copper conductor PVC insulated unshearthed FRLSH colour code cable 1100 volts grade for earth continuity as in repair/replacement complete all as specified and as directed. Note :- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1: 4 including matching the surfaces with two coats of white wash/colour wash/distemper all as per existing finishes and to the entire satisfaction of Engr-in-Charge.
-
-
-
All as per description of item No.18 here-in-before but point wiring for One light/fan point controlled by one way switch complete all as specified and as directed.
120
-
-
All as per description of item No.18 here-in-before but point wiring for One three pin 5 amp socket outlet on Independent board complete all as specified and as directed.
20
-
-
All as per description of item No.18 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5 Sqmm as continuity earth wire, for one 15Amps socket outlet point on Independent board controlled by one single pole, one way switch complete all as specified and as directed.
30
-
-
S&F Switch Modular type single pole one way 6 Amp one module as in repair/replacement complete all as specified and as directed.
140
-
-
S&F Socket outlet Modular type 2/3 Pin combined 2 module single pole multi purpose 6 Amp as in repair/replacement complete all as specified and as directed.
20
-
-
S&F Switch Modular type single pole one way 16 Amp one module as in repair/replacement complete all as specified and as directed.
30
-
-
S&F Socket outlet Modular 3 pin 6/16 Amp multipurpose two modules as in repair/replacement complete all as specified and as directed.
30
-
-
S&F modular type step fan regulator suitable for 1200/1400 mm sweep ceiling fan 02 module as in repair/replacement complete all as specified and as directed.
20
-
-
M&L for Sub main wiring with two single core 4 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metallic rigid PVC conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 4 Sqmm earth wire for earth continuity conductor complete all as specified and as directed.
Note :- 2 runs of 4sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting, chasing & making good shall be measured as one unit length.
500
-
-
M&L for Sub main wiring with two single core 6 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metallic rigid PVC conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 6 Sqmm earth wire for earth continuity conductor complete all as specified and as directed.
Note :- 2 runs of 6sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting, chasing & making good shall be measured as one unit length.
500
-
-
M&L for Sub main wiring with Four single core 10 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metallic rigid PVC conduit surface type of size 25 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 10 Sqmm earth wire for earth continuity conductor complete all as specified and as directed.
Note :- 4 runs of 10sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting, chasing & making good shall be measured as one unit length.
500
-
-
M&L for Sub main wiring with Four single core 6 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metallic rigid PVC conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 6 Sqmm earth wire for earth continuity conductor complete all as specified and as directed.
Note :4 runs of 6sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting, chasing & making good shall be measured as one unit length.
100
-
-
M&L for Sub main wiring with Four single core 2.5sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metallic rigid PVC conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 2.5 Sqmm earth wire for earth continuity conductor complete all as specified and as directed.
Note :4 runs of 2.5sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting, chasing & making good shall be measured as one unit length.
1000
-
-
S&F PVC channels with suitable cap of size 100x100mm with standard slots, CE and FR certiified for wiring Duct complete all as specified and as directed.
200
-
-
M&L for Sub main wiring with two single core 4 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including rigid steel concealed conduit of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 4 Sqmm earth wire for earth continuity conductor complete all as specified and as directed.
Note :- 2 runs of 4sqmm copper conductor phase and neutral and one run of same size earth wire including one run of steel conduit with cutting, chasing & making good shall be measured as one unit length.
1500
-
-
S&F sheet metal enclosure DBs, double door suitable for MCBs SPN 240 Volts 8 ways with 200 amps rated bus bars complete all as specified and as directed.
20
-
-
S&F sheet metal enclosure DBs, double door suitable for MCBs SPN 240 Volts 12 ways with 200 amps rated bus bars complete all as specified and as directed.
4
-
-
S&F sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc complete with & incl SP MCB 6-32 Amps , 240 volts 10 KA complete all as specified and as directed .
20
-
-
S&F MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve complete all as specified and as directed.
172
-
-
S&F MCB 32 Amps to 40 Amps, SPN 240 Volts, breaking capacity 10 KA, 'B' curve complete all as specified and as directed.
23
-
-
S&F MCCB FP 100Amps AC 415 volts, breaking capacity 16KA, B curve ISI marked complete all as specified and as directed.
12
-
-
S&F MCB SP 240 Volts 63 Amps B curve complete all as specified and as directed.
24
-
-
S&F MCB TPN 240 Volts 32 Amps B curve complete all as specified and as directed.
6
-
-
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size as in repair/replacement complete all as specified and as directed.
40
-
-
S&F energy saving, environment friendly & roboust Highbay/medium bay LED IP-65 luminarie 150 Watt at a height of 18 to 25 meters approx with high efficiency including connecting up with three core flexible copper conductor cables of suitable size as in repair/replacement complete all as specified and as directed.
10
-
-
S&F Flood Light made out of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system 200 Watt 110 LPW at a height of approx 18 to 25 meters with high efficiency accessories including connecting up with three core flexible copper conductor cables of suitable size as in repair/replacement complete all as specified and as directed.
10
-
-
Taking down old unserviceable/burnt submain wiring including conduits etc of any size and making good the disturbed surfaces all as directed.
600
-
-
Taking out old unserviceable/burnt DBs/plug & socket boxes etc of any size including MCCBs/MCBs and making good the disturbed surfaces complete all as specified and as directed.
10
-
-
S&F Modular type socket 6/16 amps 3/5 pin 2 module fitted on and including GI terminal box flush mounted with mounting plate and cover frame complete all as specified and as directed.
45
-
-
S&F modular type socket 6 amps 3 pin 2 module fitted on and incl GI terminal box flush mountedcomplte with mounting plate and cover frame complete all as specified and as directed.
45
-
-
S&F LED lights fitting 1x 20 W, 220V, AC decorative batten type with driver, holder including LED tube light 4 feet long with and including connecting up with three core flexible copper conductor cables of suitable size as in repair/replacement complete all as specified and as directed.
200
-
-
S&F LED lights fitting 1x 10 W, 220V, AC decorative batten type with driver, holder including LED tube light 2 feet long with and including connecting up with three core flexible copper conductor cables of suitable size as in repair/replacement complete all as specified and as directed.
10
-
-
S&F ceiling rose with back plate surface bakelite, 65 x 50 mm, two to three terminals as in repair/replacement complete all as specified and as directed.
50
-
-
Dismantling and taking out old unserviceable cable any type and size upto 95 sqmm complete all as specified and directed. Note- Old cables may have been burried at a depth more than 60 cm. No payment shall be made for any excavation done beyond 60 cm depth to retrieve the old cables.
2500
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm 3.5 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
400
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm 4 core aluminum conductor 1100 volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
400
-
-
M&L for steel tubular swaged poles with MS base plate 300 x 300 x 5 mm thick, closed at top as specified type 410 SP-31 (9 metres long) including painting with two coats of black bitumonus paint internally throughout and externally upto the embedded depth and remaining external portion with two coats of aluminium paint over a coat of red oxide primer and writing pole Nos with different tint complete all as specified and as directed.
17
-
-
M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and as directed.
0.6
-
-
M&L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified and as directed.
8.75
-
-
M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping to pole/struts with and including necessary form work complete all as specified and as directed.
2
-
-
M&L for mild steel sheet danger notice plate 1.6mm thick for LT of size 20x15cm, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with M.S. clamps, bolts and nuts of approved size complete all as specified and as directed.
17
-
-
S&F electric distribution box, water proof ABS, wheather proof, IP-65 protection suitable for outdoor use, pole mounted, comprising one No. MCB SP 6 Amps, 240 volts TPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 5mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts & washers made of galvanized iron and connection thimble etc. as in repair/replacement complete all as specified and as directed.
17
-
-
S&F Factory made LT feeder pillar box of size 750 mm x 750 mm x 600 mm with 4 strip copper bus bar (200 Amp, 1100 volt grade, 600 mm long duly sleeved with relevant colored sleeve- 01 set) cubical outdoor type, weather proof , fabricated out 3.15 mm CRCA sheet, dully powder coated welded on 40X40X 6 mm angle iron frame & having four Nos of angle iron legs made out of 40X40X 6 mm, 750 mm long below frame, grouted/embedded in PCC 1:2:4 type B1 using 20mm graded stone aggregate of suitable size with front, rear door having locking arrangements openable, bottom space for cable entry as in repair/replacement complete all as specified and as directed.
8
-
-
Taking out/down GI pipe light grade 80mm bore from tranches/poles complete all as specified and as directed.
50
-
-
Supply and laying/fixing steel tubing light grade galvanised 80mm bore for cable protection, laid in trench/road/path/culvert or fixed on wall/pole/MS channel etc complete all as specified and as directed.
55
-
-
M&L for horizontal boring of holes under road, Pavement, hard standing by trenchless technology using any mechanical means/method with and including HDPE pipe of 100 mm bore suitable for 0.4 mpa working pressure complete all as specified and as directed.
60
-
-
S&F MCCB, 04 poles, 400 Amps, 36 KA, 50Hz, 415 volts, Ics=100% of Icu adjustable type as in repair/replacement complete all as specified and as directed.
4
-
-
S&F MCCB, 04 poles, 250 Amps, 25 KA, 50Hz, 415 volts, Ics=75% of Icu adjustable type as in repair/replacement complete all as specified and as directed.
4
-
-
S&F MCCB, 04 poles, 200 Amps, 25 KA, 50Hz, 415 volts, Ics=75% of Icu adjustable type as in repair/replacement complete all as specified and as directed.
2
-
-
Supply, fixing, testing and commissioning ACB 630 Amps 4 pole, 50 Hz 440 Volts manually drawout type with micro processor release all as specified and directed.
2
-
-
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized steel strip 25x4mm (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 32mm bore, and watering pipe 20 mm bore GI light grade pipe with funnel & wire mesh, including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old earthing materials and removal complete all as specified and directed.
Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include GI steel strip and protection pipe of length 7.5m, GI pipe beyond 7.5m length required at site shall be measured and paid separately.
(iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
35
-
-
Supply, installation, connecting, testing and commissioning Factory made LT cubical panel (CPRI Approved as per latest norms) of suitable size, compartment type, dust, water and vermin proof, duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, 750 mm long angle iron 50mm X 50mm X 6mm legs for grouting in suitable size bed blocks of cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate, and having front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable as in repair/replacement complete all as specified and comprising the following:- a) LT bus bar aluminum 200 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 125 Amps,25 KA, 50 Hz, 415 Volts with adjustable thermal and magnetic release and (Ics = 100% of Icu)= 01 No. Outgoing : (c ) MCCB AC, 4 pole,100 Amps,16 KA, 50 Hz, 415 Volts = 01 No (d ) MCCB AC, 4 pole,63 Amps,16 KA, 50 Hz, 415 Volts = 02 Nos (e) Digital LED Amps meter with CT’s125/5 amps and selector switch= 01 Set.
(f) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(g) Phase indicator lamps RYB =01 Set (h) Internal connections with colour code copper cable of suitable size copper thimbles etc as per manufacturer's design and specfifications (j) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (k) Earthing terminals -02 Nos
4
-
-
Supply, installation, connecting, testing and commissioning Factory made LT cubical panel (CPRI Approvedas per latest norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA Sheet on 50 mm X 50 mm X 6mm angle iron frame, 750 mm long angle iron 50 mm X 50 mm X 6mm legs for grouting in suitable size bed block of cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate, and having front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable as in repair/replacement complete all as specified and comprising the following:- a) LT bus bar aluminum 1000 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 630 Amps, 35 KA, 50 Hz, 415 V with adjustable thermal and magnetic setting (Ics = 100% of Icu)= 01 No. Outgoing : (c ) MCCB AC, 4 pole, 400 Amps, 35 KA, 50 Hz, 415 V with adjustable thermal and magnetic setting (Ics = 100% of Icu)= 01 No. (d ) MCCB AC, 4 pole, 250 Amps, 25 KA, 50 Hz, 415 Volts with adjustable thermal and magnetic setting (Ics = 100% of Icu) = 02 Nos (e ) MCCB AC, 4 pole, 125 Amps, 25 KA, 50 Hz, 415 Volts with adjustable thermal and magnetic setting = 01 No. (f) Digital LED Amps meter with CT’s 630/5 amps and selector switch= 01 Set.
(g) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(h) Phase indicator lamps RYB =01 Set (j) Internal connections with colour code copper cable of suitable size copper thimbles etc as per manufacturer's design and specfifications (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (l) Earthing terminals - 02 Nos
1
-
-
Supply, installation, connecting, testing and commissioning Factory made LT cubical panel (CPRI Approved as per latest norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA Sheet on 50 mm X 50 mm X 6mm angle iron frame, 750 mm long angle iron 50 mm X 50 mm X 6mm legs for grouting in suitable size bed blocks of cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate, and having front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable as in repair/replacement complete all as specified and comprising the following:- a) LT bus bar aluminum 1000 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 630 Amps, 50 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 250 Amps, 35 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. (d ) MCCB AC, 4 pole, 200 Amps, 35 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. (e) MCCB AC, 4 pole, 160 Amps, 25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. (f) MCCB AC, 4 pole, 100 Amps, 25 KA, 50 Hz, 415 Volts = 01 No. (g) MCCB AC, 4 pole,63 Amps,16 KA, 50 Hz, 415 Volts = 01 Nos (h) Digital LED Amps meter with CT’s 630/5 amps and selector switch= 01 Set.
(j) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(k) Phase indicator lamps RYB =01 Set (l) Internal connections with colour code copper cable of suitable size copper thimbles etc as per manufacturer's design and specfifications (m) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (n) Earthing terminals - 02 Nos
1
-
-
Supply, installation, connecting, testing and commissioning Factory made LT cubical panel (CPRI Approved as per latest norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA Sheet on 50 mm X 50 mm X 6mm angle iron frame, 750 mm long angle iron 50 mm X 50 mm X 6mm legs for grouting in suitable size bed blocks of cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate and having front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable as in repair/replacement complete all as specified and comprising the following:- a) LT bus bar aluminum 400 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 250 Amps, 36 KA, 50 Hz, 415 V with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 160 Amps, 25 KA, 50 Hz, 415 V with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. (d ) MCCB AC, 4 pole,125 Amps, 25 KA, 50 Hz, 415 V with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. (e ) MCCB AC, 4 pole,100 Amps, 25 KA, 50 Hz, 415 Volts = 01 No. (f ) MCCB AC, 4 pole, 63 Amps, 16 KA, 50 Hz, 415 Volts = 01 No. (g) Digital LED Amps meter with CT’s 250/5 amps and selector switch= 01 Set.
(h) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(j) Phase indicator lamps RYB =01 Set (k) Internal connections with colour code copper cabl of suitable size copper thimbles etc as per manufacturer's design and specfifications (l) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (m) Earthing terminals -02 Nos
1
-
-
Supply, installation, connecting, testing and commissioning Factory made LT cubical panel (CPRI Approved as per latest norms) of suitable size, compartment type, dust, water and vermin proof duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA Sheet on 50 mm X 50 mm X 6mm angle iron frame, 750 mm long angle iron 50 mm X 50 mm X 6mm legs for grouting in suitable size bed blocks of cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate and having front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable as in repair/replacement complete all as specified and comprising the following:- a) LT bus bar aluminum 300 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 200 Amps, 35 KA, 50 Hz, 415 V with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 125 Amps, 25 KA, 50 Hz, 415 V with adjustable thermal & magnetic setting (Ics = 100% of Icu) = 01 No. (d ) MCCB AC, 4 pole, 100 Amps, 25 KA, 50 Hz, 415 Volts = 01 No. (e ) MCCB AC, 4 pole, 63 Amps, 16 KA, 50 Hz, 415 Volts = 02 Nos (f) Digital LED Amps meter with CT’s 200/5 amps and selector switch= 01 Set.
(g) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(h) Phase indicator lamps RYB =01 Set (j) Internal connections with colour code copper cable of suitable size copper thimbles etc as per manufacturer's design and specfifications (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (l) Earthing terminal - 02 Nos
1
-
-
Taking out old rusted steel poles of any type and size complete all as specified and as directed.
10
-
-
S&F LED light fitting 1x40 Watt, flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing, heat resistant toughened glass, LED tube light fixtures, driver, holders, connector etc. and all accessories prewired with and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
10
-
-
S&F MCB distribution board steel enclosure 3 phase 415 volts with metal plug and TPN socket including 32/40 Amps, FP MCB complete all as specified and as directed.
8
-
-
Note: The Total amount shall subject to adjustment of credit of Rs. 78,170.00 for old Materials as per Schedule of Credit.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%