Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix, caliberation and commissioning in repair compressor controller panel (ELECTKRONIKON) for compressor ATLAS COPO Model GA55VSDFF

1

-

-

... More
Taking out u/s MS air pipe lines from trenches /wall/ open area and Supply laying, jointing and testing of compressed air line MS pipe, heavy duty, class C confirming to IS 7938 laid in duct/road/nalah with flanged and joints including all fittings such as bends. Elbow, tees, short piece, connections , back nuts, diminishing pieces, caps plugs and unions etc necessary connection where ever required testing as per IS, for 150 mm bore pipe, complete all as speciefied and as directed.

24

-

-

... More
All as per Item No 5 herein before but 100 mm bore pipe.

24

-

-

... More
All as per Item No 5 herein before but 80 mm bore pipe.

36

-

-

... More
All as per Item No 5 herein before but 50 mm bore pipe.

36

-

-

... More
All as per Item No 5 herein before but 40 mm bore pipe.

66

-

-

... More
All as per Item No 5 herein before but 25 mm bore pipe.

66

-

-

... More
All as per Item No 5 herein before but 20 mm bore pipe.

66

-

-

... More
All as per Item No 5 herein before but 15 mm bore pipe.

66

-

-

... More
Supply, installation, testing and commisioning AUDCO swing type non return valve, CI regular pattern, Flanged end, Pneumatic air test pressure - 7 Kg/sqcms AUDCO Cat Part No - MW11/13, for Compressed air lines with all new nut bolts, champion make gasket and washer all as required at site, complete all as specified and dircted for 100 mm dia size.

9

-

-

... More
Taking out unservicable ball valves and Supply, installation, testing and commisioning plug valve , CI regular pattern, Flanged type, for Compressed air lines with all new nut bolts washers, champion make gasket and connected materials, all as required at site, complete all as specified and dircted for 150 mm dia size. Make of valve : AUDICO/L&T/UNIVERSAL Note:- Valve length should be same as per existing unsv valve so that it is easily replaced.

8

-

-

... More
All as per Item No 14 herein before but 100 mm bore pipe.

7

-

-

... More
All as per Item No 14 herein before but 80 mm bore pipe.

8

-

-

... More
Taking out unservicable ball valves and Supply, installation, testing and commisioning plug valve , MSI regular pattern, Flanged type/ screw type , for Compressed air lines with all new nut bolts washers, champion make gasket and connected materials, all as required at site, complete all as specified and dircted for 50 mm dia size. Make of valve : AUDICO/L&T/UNIVERSAL Note:- Valve length should be same as per existing unsv valve so that it is easily replaced.

10

-

-

... More
All as per Item No 17 herein before but 40 mm bore pipe.

10

-

-

... More
All as per Item No 17 herein before but 25 mm bore pipe.

10

-

-

... More
All as per Item No 17 herein before but 20 mm bore pipe.

10

-

-

... More
All as per Item No 17 herein before but 15 mm bore pipe.

12

-

-

... More
Supply, installation & fixing of single core flexible copper cable of 50 Sqmm single core as specified and directed. Make - Rolliflex/ Polycab/ Finolex.

120

-

-

... More
Supply, installation & fixing of single core flexible copper cable of 95 Sqmm single core as specified and directed. Make - Rolliflex/ Polycab/ Finolex. Note: Connection shall be made with appropriate size of copper thimble.

42

-

-

... More
Disconnecting of unsv After Cooler assy from the pnumatic supply system and supply fixing with the system and testing After Cooler tube bundle with shell with flange complete assembly of 2.20 metre long 58 nos material copper of size 3/8 x21 gauge including all necessary connected fittings such as nut bolt , socket , bend , union gasket etc as requird at site complete all as specified and as directed.

2

-

-

... More
Supply, Testing and Commissioning of Stainless Steel Braided Hose Pipe of 40 mm Ø and length 1500mm : (a) Hose Pipe external braiding material SS-304 (b) Hose Material: Tube/ Hose : Stainless Steel -316 Single Layer ( Single Braid) (c) Flexible . (d) End Connection: As per existing Stainless Steel Ferrule with threaded union (e) Application Media : Compressed Air . (f) 100 % Leak Proof (g) Working Temperature : 5ºC to 50ºC (h) Max. operating pressure: 7.5 bar.

2

-

-

... More
Servicing of existing water cooling tower installed at compressor house No 1 and 2 ,cleaning of cooling tower inside and out side with cleaning agent and removing group of predominantly aquatic, photosynthetic, and nucleus-bearing organisms (alage), welding the damaged part of cooling tower , replacement of cooling tower PVC honycomb type fins completely, replacement of fiber sheet complete bottom part of cooling tower ,the fiber sheet will be fixed by screwing nut bolt of suitable size ,suitable size of strip welding with help of welding machine to extra support for fiber ,spray painting with two coat of paint inside & outside after scraping old/pill paint , electrically disconnected of electric motor overhauling and servicing of cooling tower motor, replacement of bearing /bushes of suitable size ,painting of motor ,reassembling the complete repositioning of motor, connecting and testing on complete for smooth and trouble free running.

2

-

-

... More
M & L for opening and servicing of Monoblock pump of capacity 7.5 HP to 10 HP after dismantling from existing platform by disconnecting electric and water connection of pump set , decoupling pump & motor and transportation to work shop . Strip opening of the electric motor taking out burnt out windings , cleaning of rotor and stator of motor . Rewinding of motor with suitable gauge of copper winding wire , varnishing of motor dryinging and assembling of motor. Replacement of unsv bearing and bearing seal . Replacement of cable termination box and terminal bakalite sheet ,servicing and repairing of pump compete ,replacement of mechanical seals of pumps, replacement of bearing, overhauling of pump with proper alignment of pump including all necessary nut, bolts ,welding works and rubber coupling if required for setting of pump & motor complete all as specified and directed.

2

-

-

... More
Supply & Fixing in repair Fully automatic star delta starter in sheet steel enclosure, ML-2 type motor rating AC-3 duty, 415 V, 50 Hz three phase, 15 HP complete all as specified and directed. Make L&T/BCH/Siemens

2

-

-

... More
Supply and fixing in replacement of MCCB 400 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 36 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel. Make : Havells/L&T/ Legrand

2

-

-

... More
Supply and fixing in replacement of MCCB 250 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 36 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel. Make Havells/L&T/ Legrand

2

-

-

... More
Supply and fixing in replacement of MCCB 160 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 25 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel. Make Havells/L&T/ Legrand

2

-

-

... More
Supply and fixing in replacement of MCCB 100 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 16 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel. Make Havells/L&T/ Legrand

2

-

-

... More
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc including dismantling of old earthing, complete all as directed and specified.

6

-

-

... More
Taking out u/s nipple from compresed air line of any capacity ,Supply and fixing the brass nipple 15/20/25 mm bore including all fitting arrangements if required at site and testing the pressure of air all as directed by EIC .

10

-

-

... More
Repair / Rectification to leakage of MS air pipe line of size 150 mm to 100 mm dia including welding work ,earth work etc and plugging the compressed leakages of any type etc complete all as specified and directed by Engineer-in-Charge Note : welding set and T & P shall be the contractor's responsibility, Material i.e Gaskets/Nut and Bolts/Welding Machine (Whereever required) and excavation work etc are included in the quoted rates

20

-

-

... More
Repair / Rectification to leakage of MS air pipe line of size 50 mm to 80 mm dia including welding work ,earth work etc and plugging the compressed leakages of any type etc complete all as specified and directed by Engineer-in-Charge Note : welding set and T & P shall be the contractor's responsibility, Material i.e Gaskets/Nut and Bolts/Welding Machine (Where ever required) and excavation work etc are included in the quoted rates

20

-

-

... More
Repair / Rectification to leakage of MS air pipe line of size 15 mm to 40 mm dia including welding work ,earth work etc and plugging the compressed leakages of any type etc complete all as specified and directed by Engineer-in-Charge Note : welding set and T & P shall be the contractor's responsibility, Material i.e Gaskets/Nut and Bolts/Welding Machine (Where ever required) and excavation work etc are included in the quoted rates

20

-

-

... More
Supply only transformer oil for toping up or complete replacement of oil in SOCB LT oil circuit breaker of slip ring motor starter of compressor motor in compresouse house No 1 & 2 having dielectric strength 40 - 45 KV , conforming to relevent IS-335 (Transformer oil to be supplied in sealed container) complete all as specified and directed. Make of oil : POWER/ INSOLE/ GULF

210

-

-

... More
S&F in repair bronze spring loaded safety valve as per existing pattern / sample of unit, POP type heavy duty screwed made inlet BSPT threads of size 32 mm dia complete all as specified and directed by Engineer-in-Charge. Make ATAM/LEADER/ZOLOTO &EQUVILENT

6

-

-

... More
Taking out us pressure gauge from BPI lines supply, fixing, testing and calibration of 63 mm Glycerine filled, Cl 1.6 range 0 - 10.6 kg/cm Square/psi and connected to BPI Lines with suitable sizes nipple all as directed by EIC. Note: Calibration certificate submitted by contractor from authorised testing authority.

20

-

-

... More
Taking down pressure gauge from ATF line and BPI carefully, plugging the opening and caliberation of the gauge from the authorised lab . Refixing of gauge and submission of the caliberation certificate.

30

-

-

... More
Taking out unsv rubber star coupling from BPI pump supply and fixing of rubber star coupling of BPI pump all as directed by engineer in charge.

25

-

-

... More
Repair and overhauling & servicing of Rotory gear pump FLAME PROOF motor of capacity 5 HP of BPI dismentling of existing platform/location by disconnecting electric and fuel connection of pump set , decoupling pump & motor transportation to work shop . Strip opening of motor & pump , oiling greasing of motor & pump set ,replacement of bearing cleaning of stator, cleaning the slot, , of both bearing as size ,opening of fuel pump ,servicing of pump complete including supply and ,replacement of MECHANICAL seals of pumps ,replacement of bearing ,overhaling of pump proper alignment of pump including all necessary nut ,bolts ,welding works if required for setting of pump & motor replacement of rubber coupling complete all as specified and as directed.

5

-

-

... More
Material and Labour opening of Rotory Gear SELF priming FUEL PUMP OF BPI from BPI pump house foundation after disconnecting from fuel line and closing the line with dummy plate with nut bolts and dismantling the same for assesing and carring out the repairs at work shop replacemet of u/s parts such as impeller, bearing and shaft seal ,silica seal,gasket ,bushes ,nut bolts gear oil , servicing of pump complete and making good in running condition including testing of pump , reassembling the same on the foundation testing complete all as directed by Engr-in-Charge.

5

-

-

... More
Repair / Rectification to leakage of BPI fuel pipe line of size 50 mm to 100 mm dia including Gaskets, Champion make nut bolts and washers, earth work etc and plugging the fuel leake of any type etc complete all as specified and directed by Engineer-in-Charge Note : T & P shall be the contractor's responsibility, Material i.e Gaskets/Nut and Bolts (Where ever required) and excavation work etc are included in the quoted rates.

15

-

-

... More
Transfering of ATF (Fuel) from one under ground BPI tank to another tank very carefully. Cleaning of under ground ATF (Aero Turbine Fuel) storage tank of capacity 25 KL by Opening of cover lid 2 Nos including gasket, nuts and bolts of oil tank capacity 25 KL complete including dismantling of oil inlet and outlet pipe and re-positioning after necessary repair work including epi coating the complete inner surface area with approve quality paint , replacement of unserviceable foot valve of size 5" , fiber gasket 24"(MECHANICAL GAS KIT) dia champion make of good quility, all nuts and bolts of any size/ type complete . Removing of oil from the basement of the tank with any suitable means (pump etc), de-silting of oil waste/slurry and rusted materials. After complete work ATF to be refilled back in cleaned tank with the help of pump and connected material as per site requiremet.Note-Inside the ATF tank one person using mask can work continuously not more than 30 minutes . After 30 minutes replacement of that person is must, so this process go on till the completion of work . For emergency oxygen cylinder to be kept as first aid.All the material required for accomplishing the work successfully will be responsibility of the contractor. NOTE- Work Shall be excuted as satisfaction of user.

4

-

-

... More
Supply and fixing in repair stainless steel welded / flanged type pipe grade (ASTM specification: SA312 TP 304) of thickness 3 mm to 3.25 mm with stainless steel fittings(i.e, elbow, bends, reducer stainless Nut & bolts & connector) of same grade as per stainless steel pipe non reactive with ATF, water & WATER RUST /CORROSION PROOF, duly TIG (argon) welding and fixed with gasket suitable for ATF K-50 compatible rubberized gasket/sealant non reactive for ATF line of 150 mm at site all the flanged joints shall be brought at same potential by interconnecting pipes/ fittings on either side of the flanged joint with a filling point lid of the respective BPI tank complete all as specified and directed. Make - Om India Stainless steel Tube/Jindal/TATA

18

-

-

... More
All as per item No 47.00 here in before but size 100 mm dia.

24

-

-

... More
All as per item No 47.00 here in before but size 80 mm dia.

36

-

-

... More
All as per item No 47.00 here in before but size 50 mm dia.

36

-

-

... More
All as per item No 47.00 here in before but size 40 mm dia.

36

-

-

... More
Supply and fix in repair 2 Way three piece construction (Two bonnet and one intermediate body) Stainless Steel Ball Valve of 100 mm Ø Stainless-304, Butt welded PTFE seated ( Stem packing- PTFE, Stem Seal PTFE, Body Seat PTFE). Lever Operated-304 Stainless Steel with plastic sleeve. welded Pressure Rating: PN 1.6 Mechanical Polished. Two End Connection: Flange : Application : Petrol : Make: KSB/ Audco/ Universal

4

-

-

... More
All as per item ser No 52 here in before but 80 mm dia

2

-

-

... More
All as per item ser No 52 here in before but 40 mm dia

2

-

-

... More
Material and labour for applying two coats of synthetic enamel paint (as per colour code) over and including a coat of red oxide primer, on old steel surfaces any description , including preparation of steel surface, complete all as specified and directed.

200

-

-

... More
Material and labour to attend hanger motorised doors, complaints of any nature pertaining to electrical & mechanical problem of hanger motorised door like long travel, all motion motors, control panel, pendent control box, MCB's contactors, steel wire rope, control cable, pushs greasing of rope, loose nut bolts etc rectification of the fault and replacing the unsv items as per site requirement including making connection and testing after completion of Job. Note : Motorised door complaints shall be attended by a qualified technician during the currency of contract.

15

-

-

... More
Taking out U/S steel wire rope of any size from Hangar door and Supply fixing testing & commissioning steel wire rope multi stranded 6/19 center fiber core, 6 to 8 mm dia. Make :- Usha Martin/MAHADEV or equlvalent.

200

-

-

... More
Taking out U/S steel wire rope of any size from Hangar door and Supply fixing testing & commissioning steel wire rope multi stranded 6/19 center fiber core, 10 to 12 mm dia. Make :- Usha Martin/MAHADEV or equlvalent.

250

-

-

... More
Taking out U/S Hanger door wheel with pin and supply, fixing and testing Hanger door wheel with pin in existing size suitable for hanger door and model all as directed and specified by Engr in charge.

24

-

-

... More
Taking out old u/s ball bearing of any size and supply and fixing of Ball bearing (Hanger Door) 6308 ZZ/as per existing complete all as directed by Engr In Charge.

24

-

-

... More
Taking out Hanger Door wheel transport to civil workshop for refacing, regrinding and refixing of the Hanger Door Wheel as per exisiting pattern complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
Repair to control panel for hanger doors by means of taking out carefully burnt out wiring and rewiring with same gauge of PVC insulated single core multistranded copper wire of same gauge and testing of control panel for proper and smooth operation of anger door . checking serviceability of all control circuit, taking out unsv MCBs, power contractors, auxilary contacts, relays etc and taking out unsv MCBs, power contactors, relays etc . Fixing new spare parts , making all connections , checking and testing electric motor for smooth and trouble free operation. Note : New Spare part like MCBs , Contactor, relay , motor starter contactor shall be measured and paid separately as supply only

5

-

-

... More
Supply only MCB TP 415 Vols 20 Amps . Make Siemens Model 20L63107RC or equivalent in Legrand/BCH.

24

-

-

... More
Supply only power contactor 20 amps with plugin auxilary supply contactors 2 NO and 2 NC with time delay relay and test and reset button Make : Siemens cat part No 3 UX 1418 or equivalent in Legrand/BCH.

24

-

-

... More
Supply only MSP 2 P 24 plug in relay. Make : SALZER

24

-

-

... More
Supply only motor starter contactor 3 TF 30 series with AC coil and one auxilary contacts NO1 NC-0 suitable for 5 HP 3 phase electric motor of hanger door.

24

-

-

... More
Taking out unsv electric motor 3 phase 4 wire 2.5 KW by disconnecting electrically and decoupling from door gear box. Transporting the same to workshop . Strip opening the motor and taking out burnt out windings. Rewinding of the motor with same size of insulated copper wire, Insulating the motor widing with F class insulation . Assembling of the motor and transporting back to site and repositioning and reconnecting the motor . Testing of motor for smooth and trouble free working.

6

-

-

... More
Supply and fix in repair festoon cable system complete hangar door festoon trolley is plastic with nylon roller guides and used for riding on steel cable while guiding festoon cable along the door.

90

-

-

... More
Supply and fix in repair slip ring motor starter type SORS (HD) stator rotor controller 3 Phase 50 Hz Stator volts - 280 RV, Rotor volts-125 HP, Stator Amps - 202 RA, Rotor Amps- 170 A for Air compressor slipring motor of cap 150 HP. Make : BENTEX

1

-

-

... More
Taking out unservicable DOL Starter from compressor house of any capacity & Supply, installation, testing and commissioning of 3 PH ,415 VOLT ,Relay rating 18-25 Amp ,25/18 ,HP/KW,SS Enclouser grounting in wall making all in coming &out going connection and testing in full load all as directed at site. MAKE C&S/ BCH//L&T /HAVELLS.

2

-

-

... More
Taking out unservicable Reverse starter from Hanger Door any capacity & Supply, installation, testing and commissioning of 5 HP ,415 VOLT,50 HZ ,Relay rating 23-32 Amp ,SS Enclouser grounting in wall making all in coming &out going connection and testing in full load all as directed at site. MAKE : C&S/BCH//Seimens/L&T/HAVELLS.

2

-

-

... More
M&L for overhauling and re-alignment of unserviceable motorised operated Hanger doors of any size/height including replacement of defective wheel bearing, servicing of gear box and grinding of wheels for smooth movement of doors, replacement of clamps, bolts etc including cleaning ,oiling and greasing of moveable parts and welding work, complete all as specified and directed.

16

-

-

... More
Taking out unserviceable electrically operated Hanger door wheel with pin and supply, fixing and testing Hanger door wheel with pin in existing size suitable for hanger door and model , complete all as specified and directed.

16

-

-

... More
M&L for overhauling and realignment of unserviceable door rolling shutters of area not exe 12 sqm including replacement of defective bearing and gear smooth movement of doors, replacement of clamps, bolts, repair to locking system etc. including cleaning ,oiling and greasing of moveable parts and welding work, complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement of MS framed work as in doors, Hangers, gates of angle or other section with gusset plates, rails, braces , etc, complete, drilled for fixing of steel sheeting or other covering to be prepared for hanging or sliding with and including either hocks and hinges or steel hanging door fittings including of steel sheeting or other covering, running rails and guides and hanging , also tightening and fixing complete all as specified and directed. Make :- TATA/SAIL/RINL/JINDAL/JSW

4

-

-

... More
S&F in repair Copper Cables, Stranded Conductor, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Armoured with galvanised steel wires, extruded PVC Sheathed, 1100 V grade as per IS 7098 (Part 1) 1988 of size 4 Core x 2.5 Sqmm. Make - Rolliflex/ Polycab/ Finolex.

450

-

-

... More
Taking out u/s AMMETER from diffrent location supply and fix Ammeter square flush mounted digital type type of size 96x96mm of range 0-200 Amp , complete all as specified and directed by the Engr -in -charge. Make :- C&S/HPL/L&T/AE/Siemens/GE/Secure Meters

8

-

-

... More
Taking out u/s VOLT METER from diffrent location supply and fix VOLTMETER square flush mounted analog type of size 96x96mm of range 0-500 Amp , complete all as specified and directed by the Engr -in -charge. Make :- C&S/HPL/L&T/AE/Siemens/GE/Secure Meters

8

-

-

... More
Desilting/ cleaning of sewage storage well of depth 10.00 Metre and 4.85 Metre dia taking out sludge in the form of solid manually and getting out and removal to a distance n. exc 500 mtr and burried the same in low laying area as directed by Engineer-in-Charge.

190

-

-

... More
Periodic comprehensive maintenance of small industrial Boiler 850 kg/hr capacity ,10.54 kg/m2 pressure complete system. Opening top cover and taking out the complete assembly from the inside of the boiler by means of tripoid/HOT crane for removing of circulation coil type tube inside the chamber complete for proper descaling and cleaning of dust particle of the boiler, digital/manual control assembly parts, , pressure part assembly,servicing of water pump, booster pump, fuel pump, simplex filter, solenoid valve, steam separator, oil tank etc Descaling of coils and connected Rusted portion of the boiler assy will be cleaned properly by means of rubber scrabber and spray painting will be done on that portion of the equipment and complete system will be serviced properly by authorised person of the same company of the boiler manufacturer only . Certificate for servicing to be provided by concerned boiler industry engineer for its good functioning all as specified below:- Note : Chemical for descaling and other parts required during servicing shall be measured and paid separately as supply only as under (Item ser No 81 to 90).

1

-

-

... More
Supply only valve seat assembly complete all as directed at site.

6

-

-

... More
Supply only of gland washer complete al as directed at site.

9

-

-

... More
Supply only oil seal bearing complete al as directed at site.

2

-

-

... More
Supply only burner nozzle 9.5 GPH 60 DEG HO,MONARCH complete all as directed at site.

1

-

-

... More
Supply only temparature indicator TC-513 complete all as directed at site.

1

-

-

... More
Supply only RTD assembly 200 mm long complete all as directed at site.

1

-

-

... More
Supply only steam header with valve complete two nos complete all as directed at site.

1

-

-

... More
Supply and fix in repair heat atomizer for boiler of cap 850 Kg/hr complete all as directed at site.

1

-

-

... More
Supply only salt for small industrial Boiler 850 kg/hr capacity ,10.54 kg/m2 pressure complete system for testing of boiler all as directed by EIC.

200

-

-

... More
Supply only Descaling chemical for small industrial Boiler 850 kg/hr capacity ,10.54 kg/m2 pressure complete system for testing of boiler all as directed by EIC.

100

-

-

... More
Taking out unservicable steam trap by cutting of MS pipe 15 /20 mm from castic soda tub supply , fixing by welding if any alternation for fixing and testing at steam pressure of BRONZE THERMODYNAMIC STEAM TRAP OF SIZE 15 MM sample as per site requirement all as directed by EIC. Make : ATAM/LEADER/ZOLOTO

1

-

-

... More
Supply, filling and connecting with fire hydrant any size of AFFF (Aqueous Film Forming Foam) fire fighting chemical solution capacity 3% to 6%, packing size 200 litres, complete all as specified and directed.

600

-

-

... More
Repairing and Servicing of softening plant complete system. Opening top cover and carrying out for proper servicing and cleaning of dust particle of the softening plants, control assembly parts, softening plant will be serviced by cleaning the tank, water line, salt mixed water line and connected Rusted portion of the softening plant will be cleaned properly by means of rubber scrabber and spray painting will be done on that portion of the equipment and complete system will be serviced properly by authorised person of the same company manufacturer only . Certificate for servicing to be provided by concerned industry enginner for its good functioning . Any parts required for replacement due to its unserviceability will be replaced with new one and rate of the same will be considered in the coated rate, no extra amount will be admissible on this account.After finishing the repair and servicing work of the softening plants two times demonstration will be carried out by the dealer. Date of servicing and due date will be written in paint on front face complete all as specified and directed.

1

-

-

... More
Supply and fixing PVC insulated multistranded copper conductor cable of three core of size 10 Sqmm in PVC conduit suitable for wiring of pump motor /coolling tower motor connection from LT panel etc complete all as directed.

150

-

-

... More
Supply and fix 3 pahse 50 HZ AC TEFC induction motor 0.37 KW 2815 RPM IC 411 Class F for boiler room. Make : Crompton /Kirloskar

1

-

-

... More
Supply and fix in repair ball valve 50 mm dia for hot air application.

1

-

-

... More
Supply and fix in repair hot air safety valve of size 20 mm dia for 150 PSI.

2

-

-

... More
Excavation in trenches not exc 1.50 metre wide not exc 1.50 metre deep in soft/ loose soil for taking out/ laying pipe line and getting out complete all as specified.

200

-

-

... More
Returning filling in (soils) , including spreading leveling, in layers not exc 25 cm thick all as specified ad directed by Engr-in-Charge.

160

-

-

... More
Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point.

40

-

-

... More
Taking out old unsv ammeter from the panel board and supply and fix digital panel meter 4 in 1 to measure current, voltage, frequency and power factor having inbuilt programmable CT ratio and built in selector switch of size 96mm x 96mm accuracy class 1.0 with RS 485 interface for easy connectivity suitable to work on auxiliary power supply of 80-300 VAC/DC, complete all as specified and directed. Make : Conzerv model EM 6436 or equivalent in L&T / AE.

5

-

-

... More
Note :- Amount of credit of Rs. 204400.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.