Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date1 Apr 2024
Closing Date29 Apr 2024
Tender Amount₹ 36,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Strip opening of unserviceable submersible motor of cap 40 HP,3 phase ,440 volts, 50 Hz, 2900 RPM and rewinding to stator with PVC insulated copper winding wire including sleeves, thimbles& Thrust bearing bearing bush water seal & adopter stain less steel shaft neck ring of impeller gun metal minor spare parts like as bronze bushes , gland packing etc and re-assembling to the same motor after repair work , complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
All as per item No 2 here in before but rewinding of submersible motor of cap 30 HP , complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
All as per item No 2 here in before but rewinding of submersible motor of cap 20 HP , complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
Disconnecting of centrifugal pump set electrically and from suction and delivery line. Transporting pump set to workshop for repair. Strip opening of induction motor 30 HP and taking out burnt out motor winding wire from stator and rotor carefully, cleaning the stator slots carefully, rewinding to stator and rotor with copper winding wire as per exiting size of wire including providing mica paper in stator slots thimbles, ball bearing, steel shaft gun metal impeller vanishing to winding wire and drying up of the insulation in heating chamber , assembling to motor after repair work and megger testing for insulation . Transporting of the motor to site , refixng /reinstallation , reconnecting and testing for smoth and trouble free running/functioning to the entire satisfaction ofEngineer-in-Charge , complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per item No 5 here in before but for 15 HP , complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
Excavating in trenches in soft/loosec soil , not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engrineer-in-Charge. Notes: (i) Excavation shall be done carefully to avoid damage of existing cables/ pipes and protection covers. (ii) Excavation work may be got carried out in short lengths for locating fault in underground cables at different locations.

593

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipe/cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.

565

-

-

... More
Removing excavated soil to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.

28

-

-

... More
Sand cushioning to under ground cable with clean dry river sand in layer of sand 8cm thick before laying of cable and 15 cm after laying of cable, complete all as specified and directed by Engineer-in-Charge. Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.

13

-

-

... More
Protection of cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge.

1350

-

-

... More
Steel water tubing, 20 mm bore medium grade ISI Marked, galvanized with all fittings laid in trenches or fixed complete to walls, ceiling or laid in floors in and including taking up or down existing tubing and connections, cleaning for re fixing or removal to store, complete all as specified and directed by Engineer-in-Charge. Note for item No.12 to 16: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.

500

-

-

... More
All as per item No 12 here in before but Steel water tubing of 25 mm bore , complete all as specified and directed by Engrineer-in-Charge.

530

-

-

... More
All as per item No 12 here in before but Steel water tubing of 50 mm bore , complete all as specified and directed by Engrineer-in-Charge.

550

-

-

... More
All as per item No 12 here in before but Steel water tubing of 80 mm bore , complete all as specified and directed by Engrineer-in-Charge.

300

-

-

... More
All as per item No 12 here in before but Steel water tubing of 100 mm bore , complete all as specified and directed by Engrineer-in-Charge.

100

-

-

... More
Cutting existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.

29

-

-

... More
Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
Cutting existing 40 to 50 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
Cutting existing 80 to 100 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
DI pipe 80 mm (certifugally cast) class 'K-9' LA (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed with rubber gasket joint and laid in trenches or in any position in and including taking up or down existing DI/CI pipe and connections, cleaning for re fixing or removal to store, complete all as specified and directed by Engineer-in-Charge. Note for item No 21 to 22: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.

60

-

-

... More
All as per item No 21 here in before but DI pipe 100 mm (certifugally cast) class 'K-9' (ISI Mark) , complete all as specified and directed by Engrineer-in-Charge.

100

-

-

... More
All as per item No 21 here in before but DI pipe 150 mm (certifugally cast) class 'K-7' (ISI Mark) , complete all as specified and directed by Engrineer-in-Charge.

30

-

-

... More
Mild steel water pipe heavy duty both end flanged as column pipe of 100 mm bore (each length of pipe 3 metre long) in and including taking out existing unserviceable pipe, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Mild steel water pipe heavy duty both end flanged as column pipe of 80 mm bore (each length of pipe 3 metre long) in and including taking out existing unserviceable pipe, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
CI/DI fittings of size up to 150 mm bends ( any radius and angle ) Tapers any type,( straight, bend , increasing,decreasing or double socket etc)Tee pieces single branch. `Y` junction , double branch cross ( all socket or socket and spigot ) collars, caps and plugs etc., complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Run lead joints suitable for spigot & socketed CI Pipe and caulking the joints properly for avoiding leakage etc including burning out lead joint in position, removing & recovering old lead including replacment of bolts, nuts & washers & necessary earth work excavation as required and fixed as in repair for new/old pipe lines of fittings for 80mm bore, complete all as specified and directed by Engineer-in-Charge .

15

-

-

... More
All as per item No 27 here in before but of Run lead joints for 100 mm bore , complete all as specified and directed by Engrineer-in-Charge. For

16

-

-

... More
All as per item No 27 here in before but of Run lead joints for 150 mm bore , complete all as specified and directed by Engrineer-in-Charge. For

14

-

-

... More
Gun metal glove or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia in and including taking up or down old unservicable gate valve , complete all as specified and directed by Engineer-in-Charge Note for item No.30 to 37 : Excavation & earthwork shall be measured & paid separately under appropriate item of this BOQ where ever required.

30

-

-

... More
All as per item No 30 here in before but of Gun metal glove or gate valves for 25 mm dia , complete all as specified and directed by Engrineer-in-Charge.

18

-

-

... More
All as per item No 30 here in before but of Gun metal glove or gate valves for 40 mm dia , complete all as specified and directed by Engrineer-in-Charge.

7

-

-

... More
All as per item No 30 here in before but of Gun metal glove or gate valves for 50 mm dia , complete all as specified and directed by Engrineer-in-Charge.

18

-

-

... More
Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 80 mm bore pipe in and including taking down of old unservicable sluice valve with all fittings,complete all as specified and directed by Engineer-in-Charge of following dia sizes : Note: For those sluice valves which are fixed with pillar of over head tank work involve such as breaking of RCC/lead flange joints will be deemed to be included in the quoted rates, contractor will also repair the demaged floor etc.to match with existing and Joints shall be measured & paid seperately.

3

-

-

... More
All as per item No 34 here in before but of Sluice valve PN-1.6 (ISI marked) of size 100mm bore pipe , complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
All as per item No 34 here in before but of Sluice valve PN-1.6 (ISI marked) of size 150mm bore pipe , complete all as specified and directed by Engrineer-in-Charge.

4

-

-

... More
Cast iron Non return valve of 100 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to spoigot and sockete DI 200 MM dia pipe etc in and including taking up or down old unservicable CI valve , complete all as specified and directed by Engineer-in-Charge Note : Fitting will be measured and paid separetly, if any, required.

1

-

-

... More
Cast iron Non return valve of 150 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to spoigot and sockete DI 200 MM dia pipe etc in and including taking up or down old unservicable CI valve , complete all as specified and directed by Engineer-in-Charge Note : Fitting will be measured and paid separetly, if any, required.

2

-

-

... More
Cast iron Air release valve with two air outlets of 80 mm bore with fixing arrangement in and including taking up or down old unservicable CI Air release , complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
Cast iron Air release valve with two air outlets of 100 mm bore with fixing arrangement in and including taking up or down old unservicable CI Air release , complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Taking out the sluice valve 80mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge.

4

-

-

... More
Taking out the sluice valve 100mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
Taking out the sluice valve 150mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge.

3

-

-

... More
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 40 to 50mm bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc , complete all as specified and directed by Engineer-in-Charge Notes for item No.44 to 46 :- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) Pipe length will be measured and paid saperately.if required

20

-

-

... More
All as per item No 44 here in before but of size 80 to 100 mm bore , complete all as specified and directed by Engrineer-in-Charge.

20

-

-

... More
All as per item No 44 here in before but of size 150 mm bore, complete all as specified and directed by Engrineer-in-Charge.

25

-

-

... More
Removing of chocked position of CI /DI pipe line upto 150 mm dia (max 5 or 5.5 mtr pipe length consider as each job) by opening the fitting/joints and cleaning the pipe line for free flow of water & refixing in its original location , complete all as specified and directed by Engrineer-in-Charge. Notes :- (i) Materials i.e lead/lead wool, spuryan and excavation & earth work for any depth etc are included in the quoted rates. (ii) Contractor shall restore supply system within in 8Hrs.

20

-

-

... More
Removing of chocked position of GI pipe line 40/50 mm dia (max 5 or 6 mtr pipe length consider as each job) by opening the fitting/joints and cleaning the pipe line for free flow of water & refixing in its original location , complete all as specified and directed by Engrineer-in-Charge. Notes :- (i) Materials i.e lead/lead wool, spuryan and excavation & earth work for any depth etc are included in the quoted rates. (ii) Contractor shall restore supply system within in 8Hrs.

25

-

-

... More
Rotational moulded PVC, tripple layered, water storage tanks of capacity 250 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. including ball brass valve of 22mm bore,high pressure,with polythene float and fly nut in and including dismantling PVC water tanks exc 250 ltr capacity by disconnecting existing water connection and removal from site ,complete all as specified and directed by Engineer-in- Charge.

2

-

-

... More
Cutting of existing Cast Iron pipes water main/DI pipes of size 80 mm bore in position for insertion of new tee for branch connection by inserting CI fittings etc. including necessary excavation & earth work and dewatering of residual water,complete all as specified and directed by Engineer-in-Charge Note : CI fittings and joints shall be measured and paid separately under appropriate items.

6

-

-

... More
All as per item No 50 here in before but of size 100 mm bore, complete all as specified and directed by Engrineer-in-Charge.

4

-

-

... More
All as per item No 50 here in before but of size 150 mm bore, complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
Cutting the existing road of 0.30m width and 0.60m depth for laying DI/GI GI pipe with all fittings such as bends, sockets, reducers union etc, complete incl excavation in any type of soil, rfr , removal and PCC 1:2:4 of 15 cm below the GL for making the the road cut portion good , complete all as specified and directed by Engrineer-in-Charge.

10

-

-

... More
Construction of valves pit chamber of size 900x900x900mm (internal dimension), using 100 mm thick PCC (1:4:8) 40 mm graded crushed stone aggregate for foundation 15 cm thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:4 cement mortar PCC (1:2:4) type B1 coping with 20 mm graded agregate for grouting MS frame including 6 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame out of 40 x 40 x 6 mm thick angle iron including paintaing of steel surface with two coats of anti corrosive synthetic enamel paint over a coat of red oxide primers finishing coat including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs and including demolition/dismantling of existing cracked valve pit chamber ,complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
All as per item No 54 here in before but size of valves pit chamber 600x600x600mm (internal dimension) , complete all as specified and directed by Engrineer-in-Charge.

5

-

-

... More
Fabrication and fix mild steel black sheet 6mm thick cofiroming to FE 410-W( Gde-E250 quality) for valve pit chamber cover including cutting,welding, two nos holes,1 No lifting hook and grooting one side with MS fasterner/ Pes in valve pit wall/mild steel frame, provn of locking arrangement and making good disturbed surfaces with same material , complete all as specified and directed by Engrineer-in-Charge.

100

-

-

... More
PVC insulated ,unsheathed copper conductor cable 16 Sq mm ,3 core , flat in shape suitable for submersible pump motor in and including taking up or down old unservicable cable , complete all as specified and directed by Engrineer-in-Charge.

300

-

-

... More
MCCB, TPN, 100 Amp, 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA in and including taking down old unservicable MCCB , complete all as specified and directed by Engrineer-in-Charge. Note for item No 58 & 59 : Make and frame size of the new MCCB should be as per the existing unsv MCCB so that new MCCB can be fixed and connected properly in the panel

5

-

-

... More
MCCB, TPN, 160 Amp 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA in and including taking down old unservicable MCCB , complete all as specified and directed by Engrineer-in-Charge.

4

-

-

... More
Motor protection unit(MPU) three phae 415 volt , 50 HZ ,automatic phase sequence corrector automatically correct inut reverse phase, single phase protection, LV, HV, LIV, Auto of loft, timer, Dry running under & over current, unbalancing ,float switch with built in CTs (Automatic-RTM ) in and including taking down old unservicable Motor protection unit , complete all as specified and directed by Engrineer-in-Charge.

3

-

-

... More
Cast iron foot valve of size 80mm dia bore ISI marked with gun metal flapper and high quality pressure stop gasket, nuts, bolts and washers etc complete all as threaded type/flanged type or as per existing sample/ model including providing joints and jointing materials as rubber washers/gaskets with suitable type/ size of bolts and nuts, etc, including dewatering of balancing dirty water from the well chamber in and including taking down old unservicable cast iron foot valve , complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
All as per item No 61 here in before but of size 100 mm bore, complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
Display board for electric shock treatment chart of size 850x600 mm made out of CRCA sheet 2 mm thick with square pipe 35x35 mm foxed around sheet by welding and making hanging arrangement on top the board. Board shall be painted with two coats of stove enameled paint (Navy Blue) over a coat of red oxide primer and writing the detail with florescent reflective tape (As per sample) by digital computerized printing style , complete all as specified and directed by Engrineer-in-Charge.

4

-

-

... More
Repair to dry type motor starter suitable for 30 HP by replacing the following, Power contactor 4 pole 25 Amp 415 volt, overload relay 23to 32 Amp, Electronic timer switch 220 volt to 250 volts , complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
Repair to dry type motor starter suitable for 40 HP by replacing the following, Power contactor 4 pole 40 Amp 415 volt, overload relay 26 to 40 Amp, Electronic timer switch 220 volt to 250 volts , complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
Repair to dry type motor starter suitable for 15 HP by replacing the following, Power contactor 4 pole 16 Amp 415 volt, overload relay 8.9 to 13.5 Amp, Electronic timer switch 220 volt to 250 volts , complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
ON Load type changeover switch, 4 pole, 415 volts, 50 HZ AC, of capacity 200 Amps with sheet enclosure in and including taking down old unservicable change over switvh , complete all as specified and directed by Engrineer-in-Charge.

1

-

-

... More
Spare coil of Power contactor (Existing type) 4 pole, 415 volts and supply and fix new spare coil suitable for MCX-33 Power contactor in and including taking down old unservicable spare coil, complete all as specified and directed by Engrineer-in-Charge.

2

-

-

... More
Rubber mat 1.0mx2.0mx25mm thick duly tested for 11000 volt grade, ISI marked as in replacment, complete all as specified and directed.

5

-

-

... More
LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 70 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing in and including taking down old unservicable cable , complete all as specified and directed by Engrineer-in-Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.

150

-

-

... More
Supply, installation, connecting, testing and commissioning of LT cubical panel of size 1500x1500x 750 mm factory made, compartment type, dust and vermin proof (IP-55) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive locking arrangement & two coat of supper enameled first grade quality over red oxide primer with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable , complete all as specified and directed by Engineer-in- Charge and comprising the following:- (ii) All internal connection from bus bar to MCCBs will be connected with aluminium strip of suitable size. (iii) All MCCBs mounting arrangement will be adjustable towards front faces/depth wise (iv) Quoated rate deemed to be included all adjustable arrangement (v) inspection at Company premises be done and allowed by manufacturer . Contd/-----

2

-

-

... More
(A)Incoming :- (a) MCCB 4 pole,160 Amp 415 Volts, 50 Hz breaking capacity not less than 25 KA with adjustable thermal setting 63% to 100% and adjustable magnetic protection release 415 volts 50Hz complete -01 Nos. Make: Legrand /Hager/L&T(D Sine)/ BCH (Terasaki)/ Siemens /Schenider (b) Digital Voltmeter -0-500 Volts with selector switch -01 Nos Make Rishab/AE/L&T/IMP (c) RYB Indication lamps-03 Nos Make BCH/L&T/Siemens (B) Out going:- (a) MCCB 4 pole100 Amp 415 Volts, 50 Hz breaking capacity not less than 25 KA 4 pole with adjustable thermal setting 63% to 100%and adjustable magnetic protection release 415 volts 50Hz complete -03 Nos. Make Legrand/Hager/L&T(D Sine)/ BCH(Terasaki)/Siemens /Schenider (b) FASDS suitable for 40 HP Monoblick pump electric driven pump set ,3 Phase , AC 415 volt ,50 HZ( for min current carrying cap 90 Amps) with Std protection ie single phase, over volt /under volt etc complete-01 Nos Make : BCH/Seimens/scheneider /L&T MAKE: SIEMENS/L&T(D-SINE SERIES)/BCH/ LEGRAND(LEXIC SERIES ) (c) Digital Ampmeter -0-100 Amp with selector switch -01Nos Make Rishab/AE/L&T/IMP

-

-

-

... More
Supply, installation, connecting, testing and commissioning LT cubical panel of size 1500x1500x 750 mm factory made, compartment type, dust and vermin proof (IP-55) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive locking arrangement & two coat of supper enameled first grade quality over red oxide primer with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable all as specified and comprising the following:- (ii) All internal connection from bus bar to MCCBs will be connected with aluminium strip of suitable size. (iii) All MCCBs mounting arrangement will be adjustable towards front faces/depth wise (iv) Quoated rate deemed to be included all adjustable arrangement (v) inspection at Company premises be done and allowed by manufacturer (A) Incoming :- (a) MCCB 4 pole, 350 Amp 415 Volts, 50 Hz breaking capacity not less than 35/36 KA with adjustable thermal setting 63% to 100% and adjustable magnetic protection release 415 volts 50Hz complete -01 Nos. Make: Legrand/Hager/L&T(D Sine)/ BCH(Terasaki)/Siemens /Schenider

2

-

-

... More
(b) Change over switch on load front operated 415 volt 250 Amp - 01 No Make :L&T (c) Digital Voltmeter -0-500 Volts with selector switch -01 Nos Make Rishab/AE/L&T/IMP (e) RYB Indication lamps-03 Nos Make BCH/L&T/Siemens (B) Out going:- (a) MCCB 4 pole,200 Amp 415 Volts, 50 Hz breaking capacity not less than 36 KA 4 pole with adjustable thermal setting 63% to 100%and adjustable magnetic protection release 415 volts 50Hz complete -02 Nos. Make Legrand/Hager/L&T(D Sine)/ BCH(Terasaki)/Siemens /Schenider (b) FASDS suitable for 40 HP Monoblick pump electric driven pump set ,3 Phase , AC 415 volt ,50 HZ( for min current carrying cap 90 Amps) with Std protection ie single phase, over volt /under volt etc complete-01 Nos Make : BCH/Seimens/scheneider /L&T (c) MCCB, 100 Amp, 415 volt, single pole & neutral, breaking capacity not less than 16 kA -2 Nos MAKE: SIEMENS/L&T(D-SINE SERIES)/BCH/ LEGRAND(LEXIC SERIES ) (c) Digital Ampmeter -0-100 Amp with selector switch -01Nos Make Rishab/AE/L&T/IMP

-

-

-

... More
Calcium based granular (Calcium hypochlorit granular) disinfectant for Chlorination of water having more stable than chlorine gas and contains no mercury, no heavy metal contamination, supported with test certificate, specified. Brand Name Puri chlor. M/s BM Aqua Tech Pvt Ltd (Mark “ Baxer” brand)/ (Rayalseema/ M/s Grasim Industries Ltd Chemical Division / Declibac Tech Kolkata or any product approved by E-in-C’s Branch , complete all as specified and directed by Engineer-in- Charge.

2700

-

-

... More
Supply, installation, connecting, testing and commissioning of Chemical dozing pump. Non metallic solution tank of 100 Litres capacity with motor driven agitator to maintain uniform suspension throuughout the tank Electrical operated chlorine dosing tank consisting of Dosing tank of 100 Ltres of PE/FRP/ MOC with PE/FRP Ltid & Level gauge along with Single phase Electric motor and Agitator with shaft & blade in plastic -mounted on tank Lid must have hole for pouring calacium Hyprochalorite and water where necessary Lid must have provision for mounting dosing pump on lid /wall in and including taking down old unservicable Chemical dozing pump , complete all as specified and directed by Engrineer-in-Charge. Make DECLIBAC model No 96NGQ51 or equavlent in Aquafit /RAMCO.

2

-

-

... More
Repair and servicing of LT panel board by cleaning complete with carbon Tetra chloride solution, replacement of thimbles/ over heated cable pecies/ servicing of starter etc (of pump house installed at different locations) , complete all as specified and directed by Engrineer-in-Charge including carrying out following jobs of renewal :- (a ) Internal wiring of suitable size. (b ) Volt meter 0-500 volt with selector switch -1 No. (c) Amp meter 0-200 A with slector switch and CT of suitable ratio -1 No.

5

-

-

... More
Testing kit for testing of Sodium Hypo Chlorite (NaOCL) chemical solution in water , complete all as specified and directed by Engrineer-in-Charge.

6

-

-

... More
Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI earth lead 4.0 mm dia at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,in and including dismanteling of old unserviceable earthing , complete all as specified and as directed by Engineer-in-Charge. Note : (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 1.00 metre away from earth.

5

-

-

... More
Agitator motor 120 Watt,copper wound, 900 RPM, Single phase 230 Volt with Shaft and impeller and all accessories suitable for mounting on FRP Tank lid or wall in and including taking out old unserviceable motor , complete all as specified and as directed by Engineer-in-Charge. Make DECLIBAC /Aquafit/RAMCO

3

-

-

... More
Pump tube for chemical dozing system as per existing make and dimension in and including taking out old unserviceable tube , complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Injection check valve 3/8" for chemical dozing system as per existing make and dimension in and including taking out old unserviceable injection check valve 3/8" , complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Discharge tubing 3/8" for chemical dozing system as per existing make and dimension in and including taking out old unserviceable discharge tubing 3/8" , complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
Rotar Assy with bearings brackets and tolerances ring for chemical dozing system as per existing make and dimension in and including taking out old unserviceable Rotar Assy with bearings brackets and tolerances ring , complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Weighted suction line strainer 3/8" for chemical dozing system as per existing make and dimension in and including taking out old unserviceable weighted suction line strainer 3/8" , complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Roller Assy for chemical dozing system as per existing make and dimension in and including taking out old unserviceable Roller Assy, complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Gear motor complete 230 volt, 50 Hz for chemical dozing system as per existing make and dimension in and including taking out old unserviceable Gear motor complete 230 volt, 50 Hz , complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Coil 250 volt 50 Hz, 50 Hz for chemical dozing system as per existing make and dimension in and including taking out old unserviceable Coil 250 volt 50 Hz, complete all as specified and as directed by Engineer-in-Charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.