Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date11 Dec 2023
Closing Date8 Jan 2024
Tender Amount₹ 28,80,000
Costs
EMD
₹ 57,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_632124_1Bid Award Id
ViewTender No
GE (AF) MC CHD/T-44/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge.
10870
-
-
... More
Material and labour for sand cushioning with layer of dry, clean & fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge.
Note : Punned depth shall be considered for measurement purpose
101.25
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 10 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
110
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 16 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
100
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 35 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
200
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 50 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
200
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 70 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
210
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
110
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 120 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
120
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
50
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 240 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
50
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 300 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
50
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 400 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Note for srl No 06 to 16 :- Excavation and earth work, GI pipe, brick and sand cushioning or cable protection cover shall be measured and paid separately.
50
-
-
... More
Labour for road cutting upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
60
-
-
... More
Supply and laying 50mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
60
-
-
... More
Supply and laying 32mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
60
-
-
... More
S&F in replacement of Double door three phase prewired distribution board 4 way TPN made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 100 Amp rating repturing capacity 25 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
22
-
-
... More
S&F in replacement MCB DB Single pole and neutral 04 way sheet steel phospetised powder painted with IP 43 protection 240 V netural link, earth bar and din rail double door of Double door complete all as specified and as directed.
15
-
-
... More
S&F in replacement MCB DB Single pole and neutral 08 way sheet steel phospetised powder painted with IP 43 protection 240 V netural link, earth bar and din rail double door of Double door complete all as specified and as directed.
15
-
-
... More
S&F sheet metal enclosure for mounting MCCB 4 pole upto 250A including having cable entry and out arrangement, making connection with existing/new cable complete and fixing the enclosure on wall as per site requirement including taking down old unservicable sheet metal enclosure of any description.
22
-
-
... More
Supply and fixing in replacement thermal magnetic release 63 Amps 4 Pole MCCB Breaking capacity Icu 25KA all as specified and directed.
11
-
-
... More
Supply and fixing in replacement thermal magnetic release 100 Amps 4 Pole MCCB Breaking capacity Icu 25KA all as specified and directed.
10
-
-
... More
Supply and fixing in replacement thermal magnetic release 125 Amps 4 Pole MCCB Breaking capacity Icu 25KA all as specified and directed.
90
-
-
... More
Supply and fixing in replacement thermal magnetic release 250 Amps 4 Pole MCCB Breaking capacity Icu 36 KA all as specified and directed.
8
-
-
... More
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
80
-
-
... More
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity MCB SPN 32 Amps, in the MCB DB Complete with connection testing and commissioning.
60
-
-
... More
Material & Labour in replacement for Sub Main Wiring with two run single core 04 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in and PVC conduit 25 mm dia having wall thickness 2 mm, with and including 04 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor green colour earth wire all as specified and directed by Engineer-in-Charge. Note : 03 run 4 Sqmm wire & one run of pvc casing and caping will be measured as one RM.
205
-
-
... More
Material & Labour in replacement for Sub Main Wiring with two run single core 06 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in and PVC conduit 25 mm dia having wall thickness 2 mm, with and including 06 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor green colour earth wire all as specified and directed by Engineer-in-Charge.
Note : 03 run 6 Sqmm wire & one run of pvc casing and caping will be measured as one RM.
200
-
-
... More
Material & Labour in replacement for Sub Main Wiring with two run single core 10 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in and PVC conduit 25 mm dia having wall thickness 2 mm, with and including 10 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor green colour earth wire all as specified and directed by Engineer-in-Charge.
Note : 03 run10 Sqmm wire & one run of pvc casing and caping will be measured as one RM.
200
-
-
... More
M&L in replacement for earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI earth wire 4mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers of galvanised iron or steel and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in electrical plate No.03 of SSR Part I complete all as directed and specified. Note : a. The earth value/result must be less than 5.0 ohms.
b. Rates of GI strip and protection pipe upto 7.5 metre is deemed to be included in the quoted rate.
10
-
-
... More
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
50
-
-
... More
M&L in replacement for earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32x6mm as earth lead fixed by means of nuts, bolts, check nuts and washers of galvanised iron
or steel and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia med grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in electrical plate No.03 of SSR Part I complete all as directed and specified. complete all as directed and specified. Note : a. The earth value/result must be less than 5.0 ohms.
b. Rates of GI strip and protection pipe upto 7.5 metre is deemed to be included in the quoted rate.
20
-
-
... More
Shifting of LT outdoor/indoor type panel of any make and rating with in station premises afterTaking shutdown for LT panel Servicing/repair outdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rustedout,bus bar as per existing size and shape, control rewiring ,voltmeter ammeter,CTs, indicating lamps,selector switches,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands complete including scrapping of surfaces of LTpanel, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed. Note:- At new location LT outdoor/indoor shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item.
5
-
-
... More
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, 8Minimum IP43 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008
Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.
1
-
-
... More
Incommer :-
(a) MCCB, 400A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu. with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper.
(b) Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A.
Outgoing :-
(a) MCCB 320A, 4pole 36 KA with Thermal magnetic release with LSI protection. Ics= Icu =1no.
(b) MCCB 250A, 4pole 36 KA with adjustable TM release with LSI Protection, Ics= Icu. 2 nos.
(c)MCCB 100A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu.= 2nos.
Note: Panel shall CPRI approved
-
-
-
... More
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, 8Minimum IP43 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters with RS 485 connectivity, SPD, etc as per Specification sheet. The fault level for the board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD's. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set of VIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008
Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.
1
-
-
... More
Incommer :-
(a) MCCB, 320A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper.
(b) Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A.
Outgoing :-
(a) MCCB 250A, 4pole 36KA with adjustable thermal magnetic release with LSI protection, Ics= Icu =02 No.
(b) MCCB 200A, 4pole 36 KA with adjustable TM release with LSI Protection, Ics= Icu. =02 No.
Note: Panel shall CPRI approved
-
-
-
... More
Supply, installation, testing and commissioning of LT Power distribution panels indoor type, complying to IEC61439-1/2 suitable for 415V, 3 phase, 4 wire, 50 Hz, Single front, floor mounting type, extensible with bolted design having 9 fold structure and totally type tested assemblies, IP : 42 enclosure having IK09, with all accessories,all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make & each having following items :-
Incommer :-
(a) MCCB, 250A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper.
(b) Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A.
Outgoing :-
(a) MCCB 200A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=01 Nos.
(b) MCCB 125A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos.
(c)MCCB 100A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos.
(d) MCCB 63A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=01 Nos.
(e)63A, 4pole Isolator=01 Nos.
Note: Panel shall CPRI approved
1
-
-
... More
Supply, installation, testing and commissioning of LT Power distribution panels indoor type, complying to IEC61439-1/2 suitable for 415V, 3 phase, 4 wire, 50 Hz, Single front, floor mounting type, extensible with bolted design having 9 fold structure and totally type tested assemblies, IP : 42 enclosure having IK09, with all accessories,all as specified and directed by the Engr-in-charge. Note : Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make & each having following items :- Incommer :-
(a) MCCB, 250A, 4pole 36KA with adjustable thermal magnetic release with rotary operating handle, auxillary switch for ON/OFF/Trip indication and both side spreder links of copper.
(b) Phase indication and ON/Trip indication LED Lights.Digital VIF Meter with required CTs of 400/5A.
Outgoing :-
(a) MCCB,200A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos.
(b) MCCB 63A, 4pole 36KA with adjustable thermal magnetic release with LSI protection.=02 Nos.
Note: Panel shall CPRI approved
1
-
-
... More
Note:- Amount of credit of Rs.60366.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements