Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Apr 2024
Closing Date22 Apr 2024
Tender Amount₹ 17,66,000
Costs
EMD
₹ 35,320Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643322_2Bid Award Id
ViewTender No
GE(AF)/CHD/T-79/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Dismantling and taking out window type air conditioner of capacity 1.5/ 2.0 Ton of any make/ type from its original location, carrying out maintenance/ overhauling cleaning with vacuum cleaner and greasing, including cleaning of condensers/ cooling coil, cleaning of air filter with caustic soda and water mixture & checking of connections complete servicing replacement of minor unserviceable parts such as rubber bushes, washers, mounting pad, rubbers, nuts & bolts, clips etc. and re-fixing the same after testing complete all as specified and directed.
Notes: (a) Spare parts (other than minor) including gas shall be measured and paid for separately under respective item of Schedule of Works. (b) The work under this item shall be executed on emergency basis to avoid inconvenience to the users as directed by Engineer-in-Charge. In this connection condition 8 of IAFW-2249 also refers.
200
-
-
Supply & refilling refrigerant R-22 after testing, rectification of leakage in the system with brazing/ welding complete all as specified and directed
12
-
-
Supply & fix liquid line strainer in repairs complete all as specified and directed
10
-
-
Supply & fixing thermostatic switch for air conditioner in repair complete all as specified and directed. Make: Indfoss/ Denfoss.
20
-
-
Supply & fix PVC condenser fan blade in repair matching with existing type & mode complete all as specified and directed.
20
-
-
Supply & fix blower drum in repair matching with existing type & model complete all as specified and directed.
10
-
-
Supply and fix in repair fan motor 1/5 HP single Phase 230 volts complete with base, nuts, bolts & washers to match with existing type and model complete all as specified and directed. Make: AUE/ Cool Home/ Universal/ Crompton.
25
-
-
Supply & fix in replacement air filter as per existing superior quality (Window type AC 1.5/ 2.0 ton) complete as specified & directed.
50
-
-
Supply and fix in replacement condenser coil 4-row fins type in repair as per existing type & model complete all as specified & directed.
10
-
-
Supply and fix in repair wiring kit as per original specifications with bronze thimbles and code marking complete all as specified & directed.
10
-
-
Supply and fix in repair cooling coil as per existing type and model complete all as specified and directed.
40
-
-
Supply only electronic type remote control suitable for 1.5 TR window type AC as per existing. Make: LG/ Videocon/ Voltas
10
-
-
Supply and fix in replacement panel circuit board electronic for split AC 1.5/ 2.0 ton complete all as specified and directed.
20
-
-
Supply and fix front grill of window type AC of capacity 1.5 Ton complete with knobs, PVC filter etc. all as per sample including taking down old unserviceable grill complete all as specified and directed.
4
-
-
REPAIRS TO SPLIT TYPE AIR CONDITIONERS 1.5/ 2.0 TR CAPACITY ANY MAKE AND MODEL
-
-
-
Dismantling and taking out unserviceable sealed unit from existing split type AC 1.5 ton capacity of make LG/ Emulsion Climate/ Tecumseh/ Carrier/ Videocon and supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/ cooling coil, charging of compressor oil, refrigerant as per existing, including replacement of new bushes, washers, mounting rubbers, nuts & bolts and & testing complete all as specified & directed.
10
-
-
Dismantling & taking out unserviceable sealed unit from existing split type AC 2.0 ton capacity of make LG/ Emulsion Climate/ Tecumseh/ Carrier/ Videocon and supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/ cooling coil, charging of compressor oil, refrigerant R-22 including replacement of new Bushes, washers, mounting rubbers, nuts & bolts and testing complete all as specified & directed.
10
-
-
Dismantling & taking out split type air conditioner of capacity 2.0/ 1.5 Ton of any make/ type from its original location, carrying out maintenance/ overhauling, greasing after cleaning thoroughly with vacuum cleaner, checking of connections, replacement of minor unserviceable parts such as rubber bushes, washers, mounting rubbers, nuts & bolts, clips etc. and testing, complete all as specified and directed. Note: Spare parts required for replacement shall be measured and paid for separately.
275
-
-
Supply and fix in repair contactor single phase 230 volts AC 40 Amps coil range 208/ 240 volts complete all as specified and directed. Make: USHA/ SIEMENS/ L&T.
20
-
-
Supply and fix in repair capacitor 4 MFD, AC 230 volts dry type complete all as specified and directed. Make: EPCOS/ BAJAJ/ USHA/ UNISTON.
70
-
-
Supply & fix in repairs fan motor 1/8 HP single Phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit of make Carrier complete all as specified and directed.
30
-
-
Supply & fix in repairs blower motor 1/20 HP single phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit of make Carrier complete all as specified and directed.
10
-
-
Supply only remote control electronic type suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed. Make: LG/ Videocon/ Voltas.
10
-
-
Supply and fix in repairs panel circuit board electronic for split AC 1.5/ 2.0 ton complete all as specified and directed.
10
-
-
Supply and fix in repairs Tee valve of size 5/8″ and 3/8″ complete all as specified and directed.
10
-
-
Supply and fix, Tee valve of size 3/8″ and 1/4″ in replacement complete all as specified and directed
20
-
-
Supply and fix in replacement wiring kit as per original specification with bronze thimbles and code marking complete all as specified & directed.
20
-
-
MISCELLANEOUS ITEMS FOR REPAIR TO WINDOW TYPE AND SPLIT TYPE ACS
-
-
-
Supply and fix in repairs running capacitor 36 MFD, AC 230 volts grade complete all as specified and directed. Make: EPCOS/ USHA/ UNISTAR/ SIEMENS.
50
-
-
Supply and fix in repairs running capacitor 45 MFD, AC 230 volts grade complete all as specified and directed. Make: EPCOS/ USHA/ UNISTAR/ SIEMENS.
50
-
-
Supply and fix in repairs starting capacitor 100-120MFD complete all as specified and directed. Make: KELTRON/ TESLA/ SIEMENS/ SPEED.
50
-
-
Supply and fix in repairs starting relay box type (suitable for off sizes split type ACs) complete all as specified and directed. Make: SHRIRAM/ RENUTROL/ HI-TECH.
10
-
-
Supply and fix in repairs copper tubing size 5/8″ including gas welding and making leak proof complete all as specified and directed.
150
-
-
Supply and fix in repairs copper tubing size 3/8″ including gas welding and making leak proof complete all as specified and directed
150
-
-
Material and labour for black foam 4mm thick and 50mm wide for insulation, suction and discharge line complete all as specified and directed.
300
-
-
Supply and fix in repairs thermostatic switch of split type air conditioner 1.5/ 2.0 TR complete all as specified and directed. Make: Indfoss/ Denfoss.
70
-
-
Supply and fix in repairs metal plug top 15 Amps, 3 pin 230 volts grade complete all as specified and directed. Make: Anchor/ SSK/ Kalinga/ Havells.
50
-
-
S&F sheet metal enclosure single pole and neutral with 2 pin and earth plug and socket complete with 1 No. single pole 20 Amps 240 volts MCB complete including necessary fixing arrangement and connecting all incoming and outgoing electric connection complete all as specified as directed. Make: INDOASIAN/ HAVELLS/ HPL/ POLICAB/ STANDARD/ ANCHOR BY PANASONIC.
30
-
-
Attending complaints of non functional air conditioner of any make/ model/ type and making them serviceable within 48 Hrs after taking the complaint from the office complete all as specified and directed. Note: Items/ spare parts required to attend the complaint shall be measured and paid for separately under respective item.
170
-
-
Supply & refilling refrigerant R-132, R-134 after testing and rectification of leakage in the system with brazing/ welding complete all as specified and directed.
24
-
-
REPAIRS TO VOLTAGE STABILIZERS ANY MAKE AND MODEL
-
-
-
Taking down unserviceable/ burnt voltage stabilizer of capacity 5KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed.
10
-
-
Taking down unserviceable/ burnt voltage stabilizer of capacity 4KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed.
10
-
-