Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Housekeeping Services
Eprocure
Opening Date8 Feb 2024
Closing Date7 Mar 2024
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Item No1 here-in-before but underground sump of capacity 25000 gallons.

3

-

-

... More
Material, labour and T&P for Cleaning of static water tank (Fire tank) of cap up 10000 gallons by tank clean process as below complete all as specified and directed :- (a) Pumping out water from SWT and removing of sludge mechanically or mannualy and disposing it off at a distance of not less than 100 mtr from SWT . Cleaning of side walls and bottom surface by scrubing the deposite and removing the same. Cleaning of the walls with high pressure water jet and pumping out the dirty water . Sterilization of tank by eco-friendly degradable and highly effecting ( anti becteria and anti fungus chedmical). Painting of the wall with two coats of cement basespaint over a coat of cement primer. and writing date of painting /cleaning on the tank.

20

-

-

... More
All as per Item No5 here-in-before but static water tank of capacity 50000 gallons.

2

-

-

... More
Material, labour including T&P for Cleaning of sewage sump well 5 mtr dia and 9 mtr deep from ground level by mechanical/manual removal of dirty water/vegetation sludge complete all as specified and directed. Note: - (1) the contractor shall make temp ditch 10 mtr away from the well to dump the sludge removed from the well and refill the same after the work is over. (2) The contractor shall make temporary arrangements for blocking the flow of sewage till the completion of work.

100

-

-

... More
All as per Item No 7 here-in-before but sump well 3 mtr dia and 6 mtr deep.

50

-

-

... More
Supply and fix in replacement of gun metal globe or gate valve (class-1) with stainless steel, wheel head screwed both ends for iron pipes or unions conforming to IS-778 complete with jointing materials like rubber sheet, nuts and bolts for the following sizes including necessary excavation, returning filling and removal complete all as specified and directed.

-

-

-

... More
All as per Item No 9 here-in-before but 15 mm dia bore pipe.

10

-

-

... More
All as per Item No 9 here-in-before but 20 mm dia bore pipe.

10

-

-

... More
All as per Item No 9 here-in-before but 25 mm dia bore pipe.

8

-

-

... More
All as per Item No 9 here-in-before but 40 mm dia bore pipe.

8

-

-

... More
All as per Item No 9 here-in-before but 50 mm dia bore pipe.

8

-

-

... More
All as per Item No 9 here-in-before but 80 mm dia bore pipe.

5

-

-

... More
All as per Item No 9 here-in-before but 100 mm dia bore pipe.

5

-

-

... More
Supply and fix in replacement of Cast Iron Air release Valves 100mm nominal bore with single air Outlets, conforming to IS 14845-2000, duly ISI marked with nut, bolts, washers and rubber gasket fixing up in CI/DI on Water supply mains including necessary excavation, returning and filling etc complete all as directed.

1

-

-

... More
All as per Item No 10 here-in-before but Air release Valve 80 mm nominal bore.

1

-

-

... More
Supply and fix in replacement of Bronze/brass body foot valve 65mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on water supply mains and underground sump complete all as directed.

1

-

-

... More
Supply and fix in replacement of Bronze/brass body foot valve 80mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on water supply mains and underground sump complete all as directed.

3

-

-

... More
Supply and fix in replacement of Bronze/brass foot valve bronz/brass 100mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on water supply mains and underground sump complete all as directed.

3

-

-

... More
Supply and fix in replacement of Cast Iron non return/reflex valve 150mm nominal bore with by pass arrangement duly ISI marked with nut, bolts, washers and fixing up in CI/DI on water supply mains complete all as directed.

3

-

-

... More
Supply and fixing in replacement of cast iron/DI fitting for sockted/ flanged pipes up to 150 mm bore such as bends, tapers, tee pieces (single & double branch) any type and angle tapers any type (straight, bends, increasing, decreasing or double socket etc) Tee branch single branch, 'Y' junction, double branch cross collars caps and plugs up to 200 mm bore complete all as directed.

900

-

-

... More
Supply and fixing in replacement of run lead joints suitable for 150 mm bore CI/DI pipe and fittings including jointing material such as lead, spun yarn etc complete all as directed.

10

-

-

... More
All as per Item No 17 here-in-before but 100 mm bore pipe and fittings.

10

-

-

... More
All as per Item No 17 here-in-before but but 80 mm bore pipe and fittings.

10

-

-

... More
Material and labour for repair/rectification to leakage of DI/CI/GI water pipe line of size 150 mm dia spigot and socket end complete all as directed. Note :- Materials i.e Lead/Lead wool, spun yarn, excavation and earth work etc are included in the quoted rates.

150

-

-

... More
Material and labour for repair/rectification to leakage of DI/CI/GI water pipe line of size 100 mm dia spigot and socket end complete all as directed. Note :- Materials i.e Lead/Lead wool, spun yarn, excavation and earth work etc are included in the quoted rates.

100

-

-

... More
Material and labour for repair/rectification to leakage of DI/CI/GI water pipe line of size 80 mm dia spigot and socket end complete all as directed. Note :- Materials i.e Lead/Lead wool, spun yarn, excavation and earth work etc are included in the quoted rates.

120

-

-

... More
Supply and fixing in replacement of straight plain brass ferrules (or connecting screw) screwed both end suitable for 150 mm bore CI/DI pipe complete all as specified and directed.

2

-

-

... More
All as per Item No 23 here-in-before but 100 mm bore pipe.

1

-

-

... More
All as per Item No 23 here-in-before but 80 mm bore pipe.

1

-

-

... More
Material and labour for repair/rectification to leakage of GI water pipe line of size 40/50 mm dia complete all as directed. Note :- Cost of materials i.e Tee/Socket/Elbow/Nipple/Union /reducer etc reqiuired is deemed to be included in the quoted rates.

100

-

-

... More
Material and labour for repair/rectification to leakage of GI water pipe line of size 20/25 mm dia complete all as directed. Note :- Cost of materials i.e Tee/Socket/Elbow/Nipple/Union /reducer etc reqiuired is deemed to be included in the quoted rates.

100

-

-

... More
Material and labour for removing of chocked position of CI pipe line upto 150mm dia (maximum 5 or 5.5mtr pipe length consider as each job) by opening the fittings/joints and cleaning the pipe line for free flow of water & refixing in same location complete all as directed. Note :- Materials i.e Lead/Lead wool, spun yarn, excavation and earth work etc are included in the quoted rates.

100

-

-

... More
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc including dismantling of old earthing, complete all as directed and specified.

8

-

-

... More
Supply and fix in replacement of portable fire fighting extinguisher cylinder with dry powder mono ammonium phosphate 4 Mtr for 5 Kg jet length ISI Marked with hydraulic test pressure of 30 Kg f/Cm square with ABC test complete all as directed.

5

-

-

... More
Supply and fix in replacement of 15 mm bib tabs standard PTMT type any colour high pressure screwed for iron pipe minimum weight 15 mm - 90 Grams compelete all as specified and directed.

5

-

-

... More
M&L for Repairing the pump set panel boards of different capacities/location by supply and replacing the following parts complete all as specified and directed :-

-

-

-

... More
Ammeter 0-500 Amp, CT type size 96 sq mm square.

4

-

-

... More
Voltmeter 0 - 500 Volt, size 96 sq mm.

4

-

-

... More
Indicator lamps 230 Volt.

12

-

-

... More
Selector switch as per sample complete assembly.

8

-

-

... More
Supply and fixing of brass hydrant brass/bronze valve of 100 mm size single headed, complete all as specified and directed.

3

-

-

... More
Supply and fixing brass hydrant bronze valve of 80 mm size single headed, complete all as specified and directed.

3

-

-

... More
Supply and fixing canvas hose pipe 63mm dia 15mtr long hose conforming to IS-636 with brass male and female coupling conforming to IS-903, complete all as specified and directed.

4

-

-

... More
Supply and fixing brass nozzle for canvas hose 63 mm dia.

4

-

-

... More
Supply and fix canvas hose female coupling brass 63 mm dia.

4

-

-

... More
Supply and fix hydrant male coupling brass 63 mm dia.

4

-

-

... More
M & L for preperation of old painted surfaces of steel/iron and applying one coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. Note : colour of paint shall be strictly as per existing colour.

200

-

-

... More
M & L for preperation of old painted surfaces of distribution boards for motor pump set/DG set/Bore well of any size and applying two coat of blue synthetic enamel paint over a coat of red zinc oxide primer, complete all as specified and directed.

10

-

-

... More
M & L for preperation of old painted surfaces of fire hydrant cabinet of size 0.60mx0.45mx1.0m and applying two coat of post office red synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.

10

-

-

... More
Excavation in trenches in soft/loose soil etc n. exc 1.5 m wide and n.exc 1.5m in depth for foundation etc or for shafts, manholes, pier holes , laying of pipe , cable etc n.exc 10 Sqmr on plan and n.exc 1.5 mtr in depth and getting out complete all as specified and as directed.

350

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm each layers complete all as specified and as directed.

290

-

-

... More
Removal of excavated material & surplus spoil n. exc 50 m to a distance and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as directed.

60

-

-

... More
S &F energy saving LED Flood light 90 watt luminaire with high power LEDs lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium body with built in heat sinks, enclosed with toughened glass including separate compartment for cable and incl sealed /compact driver for easy access during maintenance,suitable for operating on voltage 120 - 270 volt,AC,50 HZ,covered with inbuilt surge protection device having maximum discharge surge current( Imax) -10kA (8/20 µs) ,Nominal discharge surge current ( In)-5kA (8/20 µs) and protection level (Up) upto 10 kv , out put Luminous efficacy not less then120 Lumen/Watt , CRI more then 70, conforming to IP 66, protection class 1 complete all as per Manufacturer's specifications and including necessary fixing arrangment, complete all as directed by Engr-in-Charge.

2

-

-

... More
M & L for MCCB, TPN, 400 Amp, 415 volt ,Adjustable type thermal magnetic release breaking capacity 36 KA as in repair complete all as specified and as directed by Engineer-in –charge.

2

-

-

... More
M & L for MCCB, TPN, 250 Amp 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA as in repair complete all as specified and as directed by Engineer-in –charge.

2

-

-

... More
M & L for MCCB, TPN, 200 Amp 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA as in repair complete all as specified and as directed by Engineer-in –charge.Make : Legrand/BCH/Havells

2

-

-

... More
M & L for MCCB, TPN, 160 Amp 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA as in repair complete all as specified and as directed by Engineer-in –charge.

2

-

-

... More
M & L for MCCB, TPN, 100 Amp 415 volt ,Adjustable type thermal magnetic release breaking capacity 16 KA as in repair complete all as specified and as directed by Engineer-in –charge. Note for item : Make and frame size of the new MCCB should be as per the existing unsv MCCB so that new MCCB can be fixed and connected properly in the panel Make :

2

-

-

... More
Supply and instalation ECO FIRE ABC powder type (Stored pressure )Fire Extinguisher 4 Kgs conforming to IS code -15683 operating tmperature 0⁰ tto + 55 ⁰ and fire rating 2A &21B type of fire filled with MAP Powder complete in all respect and 'A, B,C class fire inflammable liquids (Petrol, Kerosene, Paints, Diesel ) gasesous fire ,LPG and actylene and electrical fire , paper, cloth wood.

5

-

-

... More
S&F power contactor 3 pole ML- 2 of L& T with DC coil of AC-3 rating 60 Amps suitable for motor including connection with suitable size copper cable and removing unserviceable cable and connection with new copper lugs, nut bolts including taking out old unserviceable contactor form existing LT panel of pump house, complete all as specified and directed. Make.

3

-

-

... More
All as per Item No 55 here-in-before but capacity 3 pole ML 4 (model as per site requirement) etc.

2

-

-

... More
All as per Item No 55 here-in-before but capacity 3 pole ML 6 ( model as per site requirement) etc.

2

-

-

... More
All as per Item No 55 here-in-before but capacity 3 pole MNX 50 ( model as per site requirement) etc.

2

-

-

... More
All as per Item No 55 here-in-before but capacity 3 pole MNX 70 ( model as per site requirement) etc.

2

-

-

... More
All as per Item No 55 here-in-before but capacity 3 pole MNX 80 ( model as per site requirement) etc.

2

-

-

... More
All as per Item No 55 here-in-before but capacity 3 pole MNX 95 ( model as per site requirement) etc.

2

-

-

... More
M&L for boring holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine for inserting CI/GI/DI pipe upto 150 m bore hole complete with spigot socket/flange , complete all as specified and directed. Note:- CI/GI pipe shall be measured and paid separately.

20

-

-

... More
Supply and fix in replacement of pressure gauge 4 inch dial 0-15 Kgs rating complete all as specified and as directed.

6

-

-

... More
M&L for Cutting CI/DI pipes of any size in position and inserrtion of new tee before laying complete all as directed.

6

-

-

... More
Supply and fixing in replacement of steel water tubing galvanized iron medium grade laid in trenches including all fittings such as bends. Elbow, tees, short piece, connections , back nuts, diminishing pieces, caps plugs and unions etc for the following sizes, complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.

-

-

-

... More
20 mm dia bore pipe.

180

-

-

... More
25 mm dia bore pipe.

180

-

-

... More
40 mm dia bore pipe.

160

-

-

... More
50 mm dia bore pipe.

160

-

-

... More
80 mm dia bore pipe.

100

-

-

... More
100 mm dia bore pipe.

80

-

-

... More
Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of following sizes complete all as specified and directed.

-

-

-

... More
150 mm dia bore pipe.

6

-

-

... More
100 mm dia bore pipe.

6

-

-

... More
80 mm dia bore pipe.

4

-

-

... More
Supply, laying and testing 3 core PVC Submersible cable of size 25 sq mm copper conductor of multi stranded type from pump house panel to 45 HP motor in bore well, complete all as specified and directed by Engr in charge.

350

-

-

... More
M and L for Cutting Existing steel tubing for alteration or additions (each cut measured) in any condition complete all as directed for following:-

-

-

-

... More
40 to 50 mm dia bore

2

-

-

... More
50 to 100 mm dia bore

2

-

-

... More
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of following sizes including all fittings complete all as specified and directed.

-

-

-

... More
15 mm dia bore.

2

-

-

... More
20 mm dia bore.

3

-

-

... More
25 mm dia bore.

2

-

-

... More
Supply & fixed in repairs straight plain brass ferrules (or connecting screw) of following sizes, screwed both ends complete all as specified and directed.

-

-

-

... More
15 mm dia bore.

2

-

-

... More
20 mm dia bore.

2

-

-

... More
25 mm dia bore.

2

-

-

... More
Demolation of brick work built in cement mortar or cement lime mortar complete all as specified and as directed.

5

-

-

... More
Brick work with sub class 'B' bricks. Straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.

5

-

-

... More
M and L for Providing, cement concrete in copings of valve pits type CI , 1:3:6 (20mm graded stone aggregate) complete all as specified and as directed.

0.5

-

-

... More
Supply and fix in replacement of MS sheet cover 3mm thick including painted with two coats of black bitumnous paint over a coat of red oxide primer complete all as directed.

220

-

-

... More
M & L for finishing of surface fair and even, Rendering 10mm thick on fair faces of brick work or concrete surfaces 1:6 cement plaster.

40

-

-

... More
Replacement of MS angle iron of size as directed dully painted with two coats of black bitumnous paint over a coat of red oxide primer complete all as directed.

150

-

-

... More
Supply and fix in replacement of high pressure single head gear motored adjustable chemical dozing pump including lead connecting nuts injection check valve ferrul dozing system model consisting of 100 mltrs FRP tank with lid , level gauge , single phase electric motor and mounted on tank complete all as directed.

1

-

-

... More
Supply only calcium based granular chorination chemical(Calcium hypochlorit granular) ALTOCH-GP, disinfectant for Chlorination of water having more stable than chlorine gas and contains no mercury, no heavy metal contamination , supported with test certificate in the sealed plastic drum of ap 45 kgs each, complete all as specified.

405

-

-

... More
S&F in repair Thermal over load relay for motor stater ML-3 with stat and off reset of range 28 to 42 Amps conforming to cat part No Cat part no- SS91859 of L&T of equivalent in

2

-

-

... More
S&F in repair Thermal over load relay for motor stater ML-4 with stat and off reset of range 53 to 75 Amps complete all as specified and directed.

2

-

-

... More
S&F in repair Time delay switch for FASDS (Motor starter) complete conforming to cat part no 8005-1-ON-60S 230 V single phase 230 volts of L&T or equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN/GIC

2

-

-

... More
M&L for Construction of brick masonary valve pit 120cm X 120cm X 120cm having 230mm thick brick wall in cement mortar 1:6 and plastered with 15mm thick in cement mortar 1:6 all around including external surfaces of walls and internal walls with bottom of chamber pit duly cement based paint on all exposed surfaces of the following size with mild steel sheet cover 3 mm thick and angle iron frame of size 40 x 40 x 6 mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle ( including Excavation/earth work) complete all as specified and as directed.

2

-

-

... More
M&L of fabrication of column pipe 3 mtr long made out of 100 mm dia medium grade GI pipe including cutting of pipes in 3mtr length,supply and welding MS flanges heavy duty 02 Nos in workshop drilling holes,cutting slots for cables and lowering of column pipes in bore wells including providing new rubber gaskets,bolts,nuts and washers etc.complete all as sspecified and as directed. .

8

-

-

... More
All as per iten ser No 80 here-in-before but column pipe of size 80 mm.

6

-

-

... More
Material and labour for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate, as in foundation filling and mass concrete, complete all as specified and directed.

1

-

-

... More
Taking out unservicable pipe line of size 150 mm dia and Supply, laying ,testing DI pipe lines conforming to IS 839-200 of size 150 mm CLASS K-9 laid in trenches (Including all fittings making connection to existing lines ) with spigot and socket ends and lead joints etc including taking out lead from joints, complete all as specified and directed.

180

-

-

... More
All as per item ser No 83 here-in-before but DI pipe of size 100 mm bore

180

-

-

... More
Supply, filling and connecting with fire hydrant any size of AFFF (Aqueous Film Forming Foam) fire fighting chemical solution capacity 3% to 6%, packing size 200 litrs, complete all as specified and directed.

400

-

-

... More
Supply and fix in replacement aluminium strip of size 25x3 mm fixed on epoxy insulators and connecting with test point and air ternination rod over water OH tank of cap 75000 and 100000 Gallons

100

-

-

... More
Taking out unservicable DI pipe line of size 150 mm dia and Supply, laying ,testing heavy duty DI pipe lines with MS flange on both end conforming to IS 839-200 of size 150 mm CLASS K-9 laid in trenches/above ground and connecting with existing lines ) complete including gasket packing and nunts and bolts of suitable size for jointing, complete all as specified and directed.

120

-

-

... More
Taking out old unservicable MS pipe line of 65 dia bore from trenches /wall/duct/road/nallah/ open area and Supply, laying, jointing including testing of heavy duty MS pipe line (in short pieces for connection to air release valve /hydrant standpost ) for 65 mm dia bore, heavy duty, class C confirming to IS 7938 laid in trenches/wall/duct/road/nalah with flanged end joints including all fittings such as bends, elbow, tees, short piece, connectors, back nuts, diminishing pieces, caps plugs and unions etc necessary connection as required complete all as directed.

20

-

-

... More
Supply and fix in repair heavy duty butter fly valve of size 65 mm complete including gasket and nuts and bolts of required size complete all as directed.

6

-

-

... More
S&F in replacement Cast Iron Air release Valves 65 mm nominal bore with double air Outlets, conforming to IS 14845-2000, duly ISI marked with nut, bolts, washers and rubber gasket fixing up in CI/DI on Water supply pressurised line including necessary excavation, returning and filling complete all as specified and directed.

4

-

-

... More
Supply and fix in repair DI/CI Tee flange type of size 150x150x65 mm with standard length as per IS -9523 - 2000 complete all as directed.

10

-

-

... More
Painting of DI/MS pipe of size 150 mm dia external surface with two coats of post office red colour over a coad of rd oxide as primer complete all as directed.

200

-

-

... More
M&L for servicing of diesel engine prime mover for fire pump completely by means of replacement of diesel filters, oil filters , replacemetn of complete engine oil, radiator coolent completely including replacement of unsv gasket, nuts, bolts ans washers complete inclucind testing after servicing for smooth and trouble free running complete all as directed.

1

-

-

... More
Supply and replacement of maintenance free lead acid battery 12 volts 180 AH complete all as directed.

1

-

-

... More
Supply and fix in repacement of battery lead (approx 2 mtr length)copper multistranded single core pVC insulated of size 95 sqmm complete including brass thimble on both side complete all as directed.

2

-

-

... More
Taking out carefully submersible pump set upto 45 to 65 HP from tube well (for repair of pump/ motor/replacement of column pipe/submersble cable etc) complete with submersible motor, column pipes of any nos and size, submersible cable ,any size and length from tube well at approx depth 120 mtr , without damaging pump motor , submersible cable and column pipe. Stacking of column pipe and submersible cable properly . Transportin of pmp set to workshop for repair and lowering of serviceable pump set with column pipes and cable upto required depth . Connecting electrically and with delivery line etc Note :-1. Cost of T&P (Small or special) required for taking out pump set is deemed to be included in the quoted rates. Any damage to pump set, submersible cable of tube well housing shall be make good by the contrctor without any extra cost. 2. Unsv submersible pump set shall be taken out from the borewell on the same day of receipt of complaint from department and serviceable pump set held with department shall be lowered on the same day to ensure the minimum breakdown period for water supply. Contractor not attending the breakdown after receipt of complaint on telephone shall be charged Rs 10000/- from his RAR clearely mentioning date and location of breakdown not attended by contractor. Break down shall be got rectified/attended directly from the market by the department at the risk and cost of the contractor complete all as directed.

4

-

-

... More
Transporting submersible pump set to workshop for repair/overhauling.

4

-

-

... More
Strip opening of submersible bowel assy any stages and any number of impellers complete, taking out unsv parts, cleaning of complete parts, and carrying out necessary machining work such as grinding and metaling of shaft, and replacement of unsv parts and assembling the pump set and testing complete all as specified and as directed . Note spare parts required shall be measured and paid separately under items S No105 (a) to (j) here in after :

4

-

-

... More
Strip opening of submersible motor of capacity 65 HP 3 phase 415 volts 50 HZ and taking out burnt out windings . Cleaning of motor rotor and stator with cleaning material. Machining work complete including remeteling of rotor shaft etc.Rewinding of motor with stove enamelled copper wire of existing gauge . Repalcement of unserviceable parts as required. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge. Note :- Spare required shall be measured and paid separately under item S No102.01 to 102.05 here in after.

2

-

-

... More
All as per item ser 103above but submersible motor fof capacity 45 HP

2

-

-

... More
Supply only the following spare parts of submersible pump of capacity of 16.5 LPS discharge at 145 Mtr head complete all as specified and directed.

-

-

-

... More
Neck ring 4" dia type

12

-

-

... More
Stain less sleeves

12

-

-

... More
Gun metal bush

12

-

-

... More
Pump impeller

12

-

-

... More
Pump coupling

6

-

-

... More
Pump Housing bowel

2

-

-

... More
Allen key type nut and bolts

12

-

-

... More
Submersible pump shaft

2

-

-

... More
Shaft Ket

2

-

-

... More
Supply only the following spare parts of submersible motor of cap 45 to 65 HP complete all as specified and directed.

-

-

-

... More
Gun metal bush bearing

4

-

-

... More
Thrust carbon plate

4

-

-

... More
Thrust brg complete set

4

-

-

... More
Case lock

4

-

-

... More
Submersible pump ratchet

4

-

-

... More
Making all necessary arrangements for lowering of submersible pump set after repair carefully after connecting and jointing the submersible cable, MS chain/SWR and column pipe after cleaning and testing the same all as specified and directed by Engineer-in-Charge Note : Safety of pump , motor and coloum pipes, tube well and, submerible cable while lowering of submersible pump in the tube well is the responsibility of the contractor , Any damage to pump motor, column pipe, submersible cabdsle and bore well shall be recovered from the contractor as per prevailing market rates complete all as specified and directed. .

4

-

-

... More
M & L for opening and servicing of Monoblock pump of capacity 12.5 HP to 15 HP after dismantling from existing platform by disconnecting electric and water connection of pump set , decoupling pump & motor and transportation to work shop and opening the body of motor, oiling greasing of motor & pump set ,replacement of bearing, replacement of mechanical seals of pumps, replacement of bearing, overhauling of pump with proper alignment of pump including all necessary nut, bolts ,welding works and rubber coupling if required for setting of pump & motor complete all as specified and directed.

2

-

-

... More
Strip opening of induction motor 15 HP 3 phase 415 volts 50 HZ and taking out burnt out windings . Cleaning of motor rotor and stator with cleaning material. Machining work complete including remateling of rotor shaft etc. replaceemnt of bearing and bush and rewinding of motor with stove enamelled insulated copper wire of existing gauge . Repalcement of unserviceable parts as required. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge.

2

-

-

... More
Taking out unsv fan motor from water cooling tower carefully of cap 5 HP 3 phase 415 volts 50 HZ , 720 RPM. Transporting to workshop and strip opening of induction motor and taking out burnt out windings . Cleaning of motor rotor and stator with cleaning material. Machining work complete including remeteling of rotor shaft etc. replaceemnt of bearing and bush and rewinding of motor with stove enamelled insulated copper wire of existing gauge . Repalcement of unserviceable parts as required. Assembling of motor repositioning of motor and testing complete to the satisfaction of Engineer-in -Charge.

1

-

-

... More
Taking out ETH cooling tower from site and servicing of existing cooling tower , replacement of complete fins, replacement of fiber sheet complete bottom part of cooling tower ,the fiber sheet will be fixed by screwing nut bolt of suitable size ,suitable size of strip welding with help of welding machine to extra support for fiber ,cleaning of complete inside and outside portion of the cooling tower with cleaning chemical properly ,spray painting with two coat of paint inside & outside after scraping old/pill paint , electrically disconnected of electric motor overhauling and servicing of cooling tower motor, stripping out and coupling ,bearing ,taking out armature, cleaning slots ,replacement of bearing /bushes of suitable size ,painting of motor ,reassembling the complete motor into position testing on full load and welding works for cooling tower for cutting & fixing of cooling tower works required at site is the responsibility of contractor, complete all as specified and directed.

1

-

-

... More
Taking out defective sewage submersible pump sets of capacity 12.5 HP/9.37 KW from Sewage well by disconnecting electricity and water connection, decoupling pump & motor by the help of chain pully block & for opening the body of motor, taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the starter with super enamelled copper winding wire of existing gauge alongwith the following parts as under:- Mechanical seal upper- 01 No, Mechanical seal Lower- 01 No, Impeller lock nut-01 No, Impeller lock nut washer -01 no, Neck ring gun metal - 01 No, O ring-1 Nos and reconnected the motor at same location by help of chain pulley block and making all connection of motor and testing on load, complete all as specified and as directed

2

-

-

... More
Disconnecting fire fighting centrifugal booster pump set of cap 110 HP from foundation and suction/delivery line and star delta cable connection. Disconnecting of electric motor and pump from MS coupling for removing the pump and motor from foundation to outside the pump room.

1

-

-

... More
Making necessary arrangement for lifting of electric motor 3 phase 415 volts 50 HZ of cap 110 HP from pump room (below 4.5 mtr to the ground level ) carefully with out damaging motor and building and transporting the same to workshop for repair and repositioning of motor with with pump after repair.

1

-

-

... More
Strip opening of motor of cap 110 HP 3 phase for assessment of repair work . Cutting of damaged winding , taking out unsv ball bearing etc complete all as specified and directed.

1

-

-

... More
Cleaning of stator and rotor of the motor . Rewinding of the motor of cap 110 HP with super enamelled insulated copper wire of the same gauge as per existing . Varnishing of motor and drying in the heat chamber.

1

-

-

... More
Replacement of unsv bearing of motor complete all as specified and directed.

4

-

-

... More
Collecting of raw water sample from bore well no 1, 2,3,4 & 5 testing from Govt labourtary for the following examination complete all as specified and directed. (A) ORGANOLEPTIC AND PHYSICAL PARAMETER (a)Turbidity (b) PH (c) (D) Total Dissolved Solids , (B) GENERIC PARAMETER (a) Aluminium (as Al), (b) Ammonia (as total ammonia -N) (c ) Aninic detergents (as MBAS)(d) Barium ( as Ba) (e) Boron (as B) (f) Calcium (as Ca) (g) Residual Chlorine (h) Copper (as Cu) (j) Fluoride (as F) (k) Chloramines (as Cl2) (l) (Iron (as Fe) (m) Magnesium ( as Mg) (n) Miniral oil (o) Nitrate (asNO3) (p) Phenolic compound (as C6H5OH) (q) Selinium (as Se) (r) Silver ( as Ag) (s) Sulphate (as SO4) (t) Sulphide (as H2S) (u) ( (Total Alkalinity (as Calcium carbonate ) (v) Total Hardness (as CaCO3) (w) Zinc (as Zn) Chlorides (as CL) (g) Free & Saline Ammonia ( C) BACTRIOLOGICAL QUALITY (j) M.P.N of Coliform Bacilli per 100ml of water complete all as specified and as directed. Note : Raw water shall be got tested from Govt lab and report shall be submitted to the department for each sample during the currency of contract as on reqiired bases.

5

-

-

... More
Collecting of raw water sample from bore well no 1, 2,3,4 & 5 testing from Govt labourtary for the following examination (A) TOXIC SUBSTANCES (a) Cadmium (as Cd) (b) Cyanide (as CN) (c ) Lead (as Pb) (d) Mercury (as Hg) (e) Molybdenum (as Mo) (f) Nickle as Ni) (g) Pesticides (h) Polychlorinated biphenyls (j) Polyneclear aromatic hydrocarbons (as PAH) (k) Total Arsenic (as As) (l) Total Chromium (as Cr) (B) PARAMETER CONCERNING RADIOACTIVE SUBSTANCES (a) Alpha emitters (b) Beta emitters (C) PESTICIDE RESIDUE (a) Alachlor (b) Atrazine (c) Aldrin (d) Alpha HCH (e) Beta HCH (f) Butachlor (g) Chlorpyrisphos (h) Delta HCH (j) Dichlorophenoxyacetic acid (k) DDT (l) Endosulfan (m) Ethion (n) Gamma HCH (o) Isoproturon (p) Malathion (q) Methyl parathion (r) Monocrotophos (s) Phorate complete all as specified and as directed. Note : Raw water shall be got tested from Govt lab and report shall be submitted to the department for each sample during the currency of contract as on reqiired bases.

5

-

-

... More
M&L for development of bore well by air compressor of capacity 475 cft /per minutes and 150-200 PSI g appropriate capacity as required on ground till to get the clear water as well as to achive approprate yield of bore complete all as specified ad as directed by engineer -in - charge.

20

-

-

... More
Note:- Amount of credit of Rs. 248732.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.