Summary

Repair/replacement Of Various Sizes Of Unserviceable Corroted Pipe One Ci/di/gi In Tech Area And Domestic Area And Repair/arresting Leakage In Ci/di/gi Pipe, Cleaning And Painting Of Rcc Oh Tanks, Static Water Tanks And Replacment Of Unserviceable Va

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling and taking out from trenches the existing CI/DI/GI pipe 150 mm dia with spigot and socketed ends and lead joints including burning out joints and recovering lead etc. including all fittings such as bends, elbow and Tees etc. of following sizes complete all as specified and directed.

210

-

-

... More
All as per item ser No 4 herein before but pipe of size 100 mm bore

225

-

-

... More
All as per item ser No 4 herein before but pipe of size 80 mm bore

220

-

-

... More
Note for item ser No 4 to 7 : Exising old unsv pipe line CI/DI shall be disconnected only after making alternate arangement of supply .Water supply should not be hampered in any case.. Supplying, laying, Jointing and testing in trenches new ductile iron pipe conforming to IS-839-2000, class K-9 in any lenth laid in excaved trenches including all fitting such as run lead joint /tyton push or rubber gasket joint with spigot and socketed ends of following sizes complete all as specified and directed.

-

-

-

... More
(a) 150 mm Bore

95

-

-

... More
(b) 100 mm Bore

110

-

-

... More
(c) 80 mm Bore Note: Excavation/earth work & push on type rubber joint/lead joint will be measured and paid for separately

120

-

-

... More
M&L run lead joint for 200 mm bore DI pipe fittings including jointing material such as lead , spun yarn etc complete all as specified and as directed.

10

-

-

... More
M&L run lead joint for 150 mm bore DI pipe fittings including jointing material such as lead , spun yarn etc complete all as specified and as directed.

15

-

-

... More
M&L run lead joint for 100 mm bore DI pipe fittings including jointing material such as lead , spun yarn etc complete all as specified and as directed.

14

-

-

... More
M&L run lead joint for 80 mm bore DI pipe fittings including jointing material such as lead , spun yarn etc complete all as specified and as directed.

12

-

-

... More
M&L for rubber ring joint(Tyten Joint) for 200 mm dia pipe complete all as specified and as directed

10

-

-

... More
M&L for rubber ring joint(Tyten Joint) for 150 mm dia pipe complete all as specified and as directed

20

-

-

... More
M&L for rubber ring joint(Tyten Joint) for 100 mm dia pipe complete all as specified and as directed

35

-

-

... More
M&L for rubber ring joint(Tyten Joint) for 80 mm dia pipe complete all as specified and as directed

35

-

-

... More
Cleaning of CI/DI pipe of size 150 mm dia removed under item ser No 4 above and laying, jointing and connecting with the water supply line under or above ground complete all as specified and as directed

115

-

-

... More
All as per item ser No 16 above but pipe of size 100 mm dia

115

-

-

... More
All as per item ser No 16 above but pipe of size 80 mm dia

100

-

-

... More
Dismantling and taking out from trenches/walls/ceilings/floors the existing GI pipe 20 mm bore including all fittings such as bends, elbow and Tees etc. incl cleaning of following sizes complete all as specified and directed.

235

-

-

... More
All as per item ser No 19 here in before but pipe of 25 mm bore

260

-

-

... More
All as per item ser No 19 here in before but pipe of 40 mm bore

255

-

-

... More
All as per item ser No 19 here in before but pipe of 50 mm bore

230

-

-

... More
All as per item ser No 19 here in before but pipe of 80 mm bore

195

-

-

... More
Laying and connecting in old or new position (walls, ceilings, floors/trenches etc.)of size 20 mm complete all as specified - Note : 1. GI tube taken down under serial item No 19 to 23 shall be fixed under this item. 2. Rate for cutting and threading of gI tubes is deemd to be included in the quoted rates. 3. Rates for new GI fitting (socket, elbow, bend, union, nipples, reducer etc ) required for fixing of pipe is deemed to be included in the quoted rates. 4. Earth work if required shall be measured and paid separately under respective items.

40

-

-

... More
All as per item ser No 24 above but GI tubing of size 25 mm bore

20

-

-

... More
All as per item ser No 24 above but GI tubing of size 40 mm bore

25

-

-

... More
All as per item ser No 24 above but GI tubing of size 50 mm bore

26

-

-

... More
All as per item ser No 24 above but GI tubing of size 80 mm bore

31

-

-

... More
Supplying, laying, jointing and testing GI Pipe medium grade inclusive of all fittings such as bends, Tee, union, elbow, reducer and Socketed etc. ISI marked of following sizes complete all as specified and directed.

-

-

-

... More
(a) 20 mm bore

195

-

-

... More
(b) 25 mm bore

240

-

-

... More
(c) 40 mm bore

230

-

-

... More
(d) 50 mm bore

204

-

-

... More
(e) 80 mm bore

164

-

-

... More
Note: Excavation and earth work will be measured and paid for separately Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of following sizes complete all as specified and directed.

-

-

-

... More
(a) 150 mm bore

5

-

-

... More
(b) 100 mm bore

6

-

-

... More
(c) 80 mm bore

8

-

-

... More
Supply & fixing in replacement including taking down old Gun metal/globe/ gate valve with iron wheel handle screwed at both ends ISI marked suitable for GI pipe of following sizes complete all as specified and directed.

-

-

-

... More
(a) 20 mm bore.

14

-

-

... More
(b) 25 mm bore.

16

-

-

... More
(c) 40 mm bore

12

-

-

... More
(d) 50 mm bore

10

-

-

... More
(e) 80 mm bore

5

-

-

... More
(g) 100 mm bore

3

-

-

... More
S&F in replacement Cast Iron Air release Valves with single air Outlets, conforming to IS 14845-2000, duly ISI marked with nut, bolts, washers and rubber gasket of following sizes dia bore and fixing up in CI/DI on Water supply mains complete all as specified and directed.

-

-

-

... More
(a) 100 mm bore

2

-

-

... More
(b) 80 mm bore

2

-

-

... More
S & F foot valve confirming to IS:4036, of size 80 mm dia (GI/CI) complete

6

-

-

... More
S & F foot valve confirming to IS:4036, of size 100 mm dia (GI/CI) complete

2

-

-

... More
S&F in replacement of non return valve/reflex valve with by-pass arrangement od following dia ISI marked complete all as specified and directed. (a) 150 mm (6") dia

2

-

-

... More
Supply and fix in repair Analog Pressure Gauge with gauge cock, having 4 inch dia suitable for 0-10 bar fixed on delivery line of pumping line complete with all necessary fittings etc Make :Guru/Fiabeg or equivalent as approved by GE

8

-

-

... More
Supply, laying and testing 3 core PVC Submersible cable of size 25 sq mm copper conductor of multi stranded type from pump house panel to 45 HP motor in bore well, complete all as specified and directed by Engr in charge. Make: Finolex/Plaza/Gloster/Premier

225

-

-

... More
Supply, laying and testing 3 core PVC Submersible cable of size 35 sq mm copper conductor of multi stranded type from pump house panel to 60 HP motor in bore well, complete all as specified and directed by Engr in charge. Make: Finolex/Plaza/Gloster/Premier

275

-

-

... More
M&L for CI/DI fitting i.e. bends any type radius/angles tapers and type straight bends increasing, decreasing or double socket etc. Tee pieces Collars Taps push on type rubber joint/lead joint and plugs etc. ISI Marked not exceeding 200 mm bore complete all as specified and directed.

600

-

-

... More
Cutting Existing steel tubing for alteration or additions (each cut measured) in any condition complete all as specified and directed.

-

-

-

... More
(a) 40 to 50 mm bore

8

-

-

... More
(b) 50 to 100 mm bore

7

-

-

... More
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of following sizes including all fittings complete all as specified and directed.

-

-

-

... More
(a) 15 mm bore.

4

-

-

... More
(b) 20 mm bore.

5

-

-

... More
(c) 25 mm bore.

6

-

-

... More
Supply & fixed in repairs straight plain brass ferrules (or connecting screw) of following sizes, screwed both ends complete all as specified and directed.

-

-

-

... More
(a) 15 mm bore.

4

-

-

... More
(b) 20 mm bore.

4

-

-

... More
(b) 25 mm bore.

6

-

-

... More
Supply and fixing in replacement 15 mm bib tabs standard PTMT any colour high pressure screwed for iron pipe minimum weight 15 mm - 90 Grams fix complete,

12

-

-

... More
Demolation of brick work built in cement mortar or cement lime mortar complete

12

-

-

... More
Brick work with sub class 'B' bricks. Straight or curved on plan exc 6m mean radius built in cement mortar 1:6.

12

-

-

... More
Providing cement concrete for coping of valve pits type CI 1:3:6 (20mm graded aggregate)

1

-

-

... More
Replacement of MS sheet cover 3mm thick duly painted with two coats of black bitumnous paint over a coat of red oxide primer complete all as directed.

300

-

-

... More
M & L for finishing of surface fair and even, Rendering 10mm thick on fair faces of brick work or concrete surfaces 1:6 cement plaster.

40

-

-

... More
Replacement of MS angle iron of size as directed dully painted with two coats of black bitumnous paint over a coat of red oxide primer complete all as directed.

250

-

-

... More
Supply and replacing MS bend 80 mm dia 45 cm long dully bended and welded to required shape complete with flanged ends incl jointing materials such as nuts,bolts,washers and gaskets etc complete all as directed.

3

-

-

... More
M & L PCC 1:4:8 type C-2 for foundation work all as directed.

2.5

-

-

... More
S/F Ball valves high pressure of PTMT with eporxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete.

18

-

-

... More
S&F in repir power contractor 3 pole ML-4 conforimg to cat part No SS-90910of L&T with DC coil of AC3 rating 70 to 110 Amps suitable for motor including connection with new copper cable of sitable size and connection with new copper lugs and testing for smoth and trouble free running of starter on load. Make : equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN

3

-

-

... More
S&F in repir power contractor 3 pole Type MNX 95 (2NO+2NC) 3 pole of L&T cat part No CS 94136 with DC coil of rating AC-3 160 Amps suitable for motor including connection with new copper cable of sitable size and connection with new copper lugs and testing for smoth and trouble free running of starter on load. Make : equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN

3

-

-

... More
S&F in repir power contractor 3 pole Type MNX 110 (2NO+2NC) 3 pole of L&T cat part No CS 94136 with DC coil of rating AC-3 160 Amps suitable for motor including connection with new copper cable of sitable size and connection with new copper lugs and testing for smoth and trouble free running of starter on load. Make : equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN

3

-

-

... More
S&F in repair Thermal over load relay for motor stater ML-3 with stat and off reset of range 28 to 42 Amps conforming to cat part No Cat part no- SS91859 of L&T of equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN

9

-

-

... More
S&F in repair Thermal over load relay for motor stater ML-5 with stat and off reset of range 45to 75 Amps conforming to cat part No Cat part no- SS-94137 of L&T of equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN

7

-

-

... More
S&F in repair Time delay switch for FASDS (Motor starter) complete conforming to cat part no 8005-1-ON-60S 230 V single phase 230 volts of L&T or equivalent in BCH/LEGRAND/SCHINDER/GE/SIEMEN/GIC

6

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 10 sqmm with copper thimble complete all as specified and as directed.

150

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 25 sqmm with copper thimble complete all as specified and as directed.

130

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 35 sqmm with copper thimble complete all as specified and as directed.

110

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 50 sqmm with copper thimble complete all as specified and as directed.

110

-

-

... More
Construction of brick masonary valve pit 120cm X 120cm X 120cm having 230mm thick brick wall in cement mortar 1:6 and plastered with 15mm thick in cement mortar 1:6 all around including external surfaces of walls and internal walls with bottom of chamber pit duly cement based paint on all exposed surfaces of the following size with mild steel sheet cover 3 mm thick and angle iron frame of size 40 x 40 x 6 mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle ( including Excavation/earth work) complete all as specified and as directed.

12

-

-

... More
M&L of fabrication of column pipe 3 mtr long made out of 100 mm dia medium grade GI pipe including cutting of pipes in 3mtr length,supply and welding MS flanges heavy duty 02 Nos in workshop drilling holes,cutting slots for cables and lowering of column pipes in bore wells including providing new rubber gaskets,bolts,nuts and washers etc.complete all as sspecified and as directed. .

40

-

-

... More
Collecting of raw water sample from bore well no 1, 2,3 and 4 and testing from Govt labourtary for the following examination (a)Turbidity (b) PH (c) Residual Chlorine (d) Total Alkalinity (as CaCO3) (e) Total Hardness (as CaCO3) (f) Chlorides (as CL) (g) Free & Saline Ammonia (h) Total Dissolved Solids (j) M.P.N of Coliform Bacilli per 100ml of water complete all as specified and as directed. Note : Raw water shall be got tested from Govt lab and report shall be submitted to the department for each sample during the currency of contract as on reqiired bases.

16

-

-

... More
Development of bore well by air compressor of capacity 350 PSI 900 CFM appropriate capacity as required on ground till to get the clear water complete including carrying out yield test complete all as specified and as directed.

40

-

-

... More
M&L for arresting water leakages/ clearing blockage from existing DI/CI pipe line in position of following sizes ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint nut and bolts,washers etc complete.All as specifide and directed by Engineer- In- Charge. Note:- Excavation up to 1x1x6 Mtr will be deem to incl in quoted rates and beyound shall be measured and paid separately. (ii) Complaint /breakdown in pipe line shall be attended and rectified within 6 hrs from receipt of complaint. Contractor shall be penalised @ 500/- per hrs for non compliance

-

-

-

... More
(a) 150 to 200 mm bore

50

-

-

... More
(b) 80 to 100 mm bore

100

-

-

... More
M&L for arresting of water leakage from existing pipe line in position from GI pipe of following sizes ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl fixing of jointing material such as GI ( Bend,socket,reducer,tee,furrel, union ,solution,thread etc) and refixing etc complete.All as specifide and directed by Engineer- In- Charge. Note:- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rates and beyound shall be measured and paid separately.(ii) cost of Jointing material such as socket, bend, elbow, reducer, nipple , union and dummy plug required if any is deemed to be included in th quoted rates (iii) Complaint /breakdown in pipe line shall be attended and rectified within 6 hrs from receipt of complaint. Contractor shall be penalised @ 500/- per hrs for non compliance .

-

-

-

... More
(b) 40 to 50 mm bore

50

-

-

... More
(c) 15 to 25 mm Bore.

80

-

-

... More
Disconnecting and taking down carefully old UNSV/ non functional aviation light fitting of any pattern any description and in any position complete and supply, installation, commissioning and testing on over head reservior new LED aviation obstruction lights, comprising of die cast aluminium alloy housig, finished in avaitation yellow colour, polycarbonate enclosures in red colour , with and including 302 Nos LED and accessoried complete all as specified and directed Note : Rate for any preparatory works, T&P and other resources reqd for dismantling /repair/ fixing of aviation obstruction light, air termination rod etc on the top of OHR at the height of 20 to 25 m from Ground level is deemed to be included in the scope of above item.

6

-

-

... More
S & F in repair 40 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified .

35

-

-

... More
S & F in repair 50mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified .

30

-

-

... More
Supply & replacement of PVC suction tube for chemical dozing system as per existing make and dimension and as directed complete all as specified and as directed

22

-

-

... More
Supply & replacement of injection check valve 3/8" .for Chemical dosing pump

3

-

-

... More
Supply & replacement of discharge tubing 3/8" . For chemical dosing pump

45

-

-

... More
Supply & replacement of Rotar Assy with bearings brackets and tolerances ring .

3

-

-

... More
Supply & replacement of but suction line strainer 3/8" .

3

-

-

... More
Supply & replacement of Roller Assy .

5

-

-

... More
Supply & replacement of Gear motor complete 230 volt, 50 Hz .

5

-

-

... More
Dismantling and taking down solar water heater system after disconnecting electric and water supply connection and opening of 200 ltrs capacity solar water heater system made up of 2 Nos 100 ltrs capacity solar collector and opening and separating each collector of 100 ltrs capacity from the existing frame by unscrewing the frame joint, dismantling and taking out top cover made out of toughened glass from the top of the solar collector for the cleaning the inner copper tube with the help of electric driven mono block pump set by using de-scaling chemical solution and giving aedquate pressure of water till the deposited silt is thrown out from the tubes and drying out with the help of replacement blower and finally removing the dust particles with the help of vaccum cleaner including replacement of unserviceable nut bolts, dead flanges, gasket etc and refixing the same in original pattern and testing, complete all as directed.

17

-

-

... More
Supply and fixing in replacement of heating element of capacity 3 KW with thermostat from the hot water tank by opening the outer frame of the tank, draining out the hot water and replacement of heating element of capacity 3 KW with thermostat compete all as directed.

17

-

-

... More
Dismantling and refixing of hot hot water tank capacity 400/500 ltrs from the unit and taking out the inner tank for de-scaling and necessary welding for checking leakages including providing fresh lagging and outer aluminum sheet cover of original gauge and sill, complete all as specified and directed.

12

-

-

... More
Dismantling and refixing of hot hot water tank capacity 200 ltrs from the unit and taking out the inner tank for de-scaling and necessary welding for checking leakages including providing fresh lagging and outer aluminum sheet cover of original gauge and sill, complete all as specified and directed.

7

-

-

... More
M&L for replacement of flat plate collector based on indirect transfer of heat suitable for 100 LPD capacity solar water heater ISI marked complete all as specified and directed.

7

-

-

... More
M&L for replacement of flat plate collector based on indirect transfer of heat suitable for 200 LPD capacity solar water heater ISI marked complete all as specified and directed.

7

-

-

... More
Material and labour for replacement of unserviceable solar collector glass made out of toughened glass ISI marked as per original pattern and size of capacity 500/200 ltrs complete all as specified and directed.

11

-

-

... More
Material and labour for replacement of unserviceable temerature gauge on hot water tank as per original pattern and size complete all as specified and directed.

11

-

-

... More
Supply and fix in replacement of rubber hose pipe of 25 mm bore , 300 mm long ISI marked complete all as specified and directed.

10

-

-

... More
Supply & fixing 2mm thick aluminium cladding over the outer insulation of hot water pipe complete all as specified and as directed.

22

-

-

... More
Taking shutdown for LT panel Servicing/repair outdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rustedout,bus bar as per existing size and shape, control rewiring ,voltmeter ammeter,CTs, indicating lamps,selector switches,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands complete including scrapping of surfaces of LTpanel, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed.

9

-

-

... More
Shifting of Motor/ pump of any make and rating with in station premises afterTaking shutdown for Motor/ pump from LT panel, Servicing/repair Motor/ pump by fixing of broken parts with welding , replacement of locking arrangement, handle, burnt /rusted out, burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose nut bolts complete including scrapping of surfaces of Motor/ pump, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed. Note:- 1.At new location Motor/ pump shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.2.Electrical connection and welding work for water pipe line connection should be done to make serviceable and operational in this job by the contractor The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item .

2

-

-

... More
Supply, installation testing and commissioning of GSM module based water level indicator digital type comprising of float sensor to senses the water level with the help if gravity ball based technique to be activated with the help of programmable microcontroller (Arduino) complete with display unit for RCC OH tanks of capacity 75000 gallon to 100000 gallons and staging 25 mtrs. the sensor to be installed in RCC OH tank and display unit to be installed in pump house starter panel room. The sensor of water level indicator shall be of rugged in construction & designed for long term maintenance free operation. It should be user friendly & easy to calibrate. It shall be free from any moving parts to avoid wear and tear. The instrument should be manufactured & fullfill all the conditions mentioned in the standard IEC 60571-1998. The display unit shall be compact in size compatible to GSM module which will send SMS targeted person mobile phone. The display unit along with microcontroller GSM Module relay provided with mounting arrangement so that it can be easily mounted alongside starter panel. It shall have inbuilt display for level indication in %age and provide audio & visual alarm at a predetermined value (30% or less of the tank volume) of water level and send SMS alert to the mobile phase of a person . This value shall be user adjustable including dismantling old. Note Connection with appropriate size of cable as recommended by OEM from pump house building to overhead tank along with PVC conduit is deemed to be included in the quoted rates. MAke TechSparkle, Divya, Active Control, MV instruments

2

-

-

... More
M&L for cleaning of over head RCC OH tank of cap 100000 gallons in two compartments having 50' staging by removing silt/mud/sand of any type and volume including scraping of internal surface of both the compartment of the tanks with wire brush and throwing out side . Washing of walls completely and draining out complete refuge . Allowing the wall and bottom surface to dry and applying two coats of WPM 300 (Water based Epoxy membrane) approved for use in potable water and conformity with the requirement of CFTRI, BS 6920:2000 and AS/NZS 4020:1999 over a coat of WPM 200 as primer complete all as specified and as directed and painting externally with two coats of cement base paint including scrapping down old cement base paint out side surface including staging and painting of iron ladder, Rising main, delivery delivery main,overflow and wash out ppe line of tank with two coats of synthetic enamel paint over a coat of red oxide as primer including writing the date of cleaning and painting on the front side of the tank black paint complete all as specified and as directed. Note :- Cost of necessary T&P/scafolding incl safety equipments required for painting outside surface of over head tank is deemed to be included in the quoted rates.

2

-

-

... More
All as per ditem ser No 102 but OH tank of cap 75000 Gallons

3

-

-

... More
All as per item No. 102 above but RCC overhead tank of capacity 25000 gallons single compartment complete all as specified and directed.

2

-

-

... More
All as per item No. 102 above but underground sump of capacity 25000 gallons complete all as specified and directed.

2

-

-

... More
S&F First Aid box made up of glass & glass & wooden frame caintaining following items (a) Dettols bottle100 ml 02 bottles (b)Antiseptic Ointment 100 mg © Crocin tabletes 40 strips ( containings 10 Tablets each. (d) Hydrogen peroxide 50 ml 01 bottle (e) Cotten small rolls 2 Nos (f) Cotten strip small roll 04 Nos Move tube 01 Nos

14

-

-

... More
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 25 x 4 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia med grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc complete all as directed and specified. Note : 1. The earth value/result must be less than 5.0 ohms. 2. Rates of GI strip and protection pipe upto 7.5 mtr is deemed to be included in the quoted rate.

22

-

-

... More
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia med grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc complete all as directed and specified. Note : 1. The earth value/result must be less than 5.0 ohms. 2. Rates of GI wire and protection pipe upto 7.5 mtr is deemed to be included in the quoted rate.

15

-

-

... More
Supply only in replacement of 3 core flexible cable of size 1.5 Sqmm with FRLSH PVC round sheathed multi copper conductor with PVC conduit of size 20 mm complete all as specified and as directed

240

-

-

... More
Dismantling of vertical line of size 200mm from over head tank to valve pit chamber approx 25 mtr and cutting the leakage flange of size 200 mm replace it with new flanage of the same size as per existing and again refixing the water pipe line of size 200 mm from valve pit chamber to over head tank and make it serviceable for pumping without any leakage complete all as specified and as directed.

2

-

-

... More
M&L for painting of different size of pump line at various pump installation dully painted with two coats of blue and red paint over a coat of red oxide primer complete all as specified and as directed.

310

-

-

... More
Material, labour and T&P for running outdoor and water proof LED display for various pump houses with the following specification (a) Display Requirement :- screen configeration ( w x h) - As per site requirement in rectangle shape (b) Physical Parameter :-(i) Pixel pitch - 10.4 mm or better ( Lesser is better ) Higer will not be acceptable . (ii) Cabinet / Pixel Configeration - SMD 3-in-1. (c) Optical Parameter :- (i) Brightness (After calibration )- 5000 Nits or Higher (ii) Contrast Ratio - 3000:1 or higher (iii) Viewing angle (Horizontal) - 140 degree or higher (iv) Viewing angle (Verticial) - 100 degree or higher (v) Bit Depth - 14 bit (d) Electrical Parameter :- (i) Cabinet - input power range - 100-240 v AC, 50/60 HZ (ii) Refresh rate = - 3800 Hz or higher (e) Operation Conditions - (i) Working Temperature/ Humidity - or better - -20 degree to 50 degree / 10-90% (ii) IP Rating Weather proof Design Front / Rear - IP65/IP65 (iii) LED Lifetime - 100,000 hours (f) Controller :- As per site requirements. Inputs should be compatable with screen and media player. Resolution, Range, Load Capcity etc in sync and as per requirement of screen. (g) Structure & Fabrication :- Solid MS fabrication framework, to hold the screen and set up firm, in open ground. Should be able to bear the load of screen set up, other items and resist wind pressures. Note:- Elelectrical connections and testing of running LED display should be made by contractor in the quoted rate.

110

-

-

... More
Supply and fixing in replacement of MCCB 100 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 16 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel.

4

-

-

... More
Supply and fixing in replacement of MCCB 160 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 25 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel.

3

-

-

... More
Supply and fixing in replacement of MCCB 250 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 36 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel.

1

-

-

... More
Supply and fixing in replacement of MCCB 400 Amp rating, 4 pole, 415 volts,50 HZ thermal and magnetic release of breaking capacity 36 KA complete all as specified and directed . Note : MCCB of same frame size as pe existing is to be provided so that it is properly fixed in the MS enclosure of panel.

1

-

-

... More
Schedule of Credit

-

-

-129041



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.