Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Sep 2024
Closing Date30 Sep 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671358_1Bid Award Id
ViewTender No
GE/CHD-48/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule A Notes, Schedule of Credit, Schedule B C D ,Special conditions, Particular specification and other connected documents.
BOQ Items
Taking down existing unserviceable sub main wiring with upto 2/3 core 2.5/4/6/10 Sqmm aluminum/Copper cable all as directed by Engineer-in-Charge.
2600
-
-
M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistandad copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc., all as specified and as directed for One light point controlled by one way switch 5 Amp complete all as specified. Note : cable Colour should be as per IS code.
990
-
-
All as per item No 5 above but One ceiling /exhaust fan point controlled by one, one way 5 Amps switch
170
-
-
All as per item No 5 above but One 3 pin socket outlet 5 Amps on independent board
120
-
-
All as per item No 5 above but One 3 pin socket outlet 5 Amps on same board
85
-
-
All as per item No 5 above but One light point controled by two, two way 5 Amps switches.
20
-
-
All as per item No 5 above but One bell/ buzzer point controled by one bell push on same board with other switches or on independent board.
21
-
-
M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
80
-
-
M&L for Point wiring complete with 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
35
-
-
M&L for Point wiring with 1.5 Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS dolly in existing concealed/surface conduit including concealed in wall, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc for the One light point controlled by one way 5 Amp switch NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items.cable Colour should be as per IS code.
(ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates.
250
-
-
All as per item No 13 above but One ceiling /exhaust fan point controlled by one, one way 5 Amps switch
70
-
-
All as per item No 13 above but One 3 pin socket outlet 5 Amps on independent board
35
-
-
All as per item No 13 above but One 3 pin socket outlet 5 Amps on same board
25
-
-
All as per item No 13 above but One light point controled by two, two way 5 Amps switches.
15
-
-
All as per item No 13 above but One bell point controlled by one way bell push switches.
12
-
-
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity complete all as specified and as directed. Note :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
900
-
-
All as per item No 19 here in above but with 2X6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete.
600
-
-
All as per Item No 19 here in above but of 3X2.5 Sqmm.
900
-
-
Disconnection and removing the u/s 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistandard with copper conductor drawn in the existing metal/PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete all as specified and as directed.
1100
-
-
Supply and fixing switch piano flush type universal single pole one way 5 amps 230 volts.
230
-
-
Supply and Fixing switch socket flush type universal 2 in 1, 3 pin, 5 Amps 230 volts.
45
-
-
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts.
35
-
-
Supply and Fixing switch socket flush type universal 2 in 1, 3/6 pin 15 Amps 230 volts.
35
-
-
Supply and fixing switch piano flush type single pole two way 5 amps 230 volts.
20
-
-
Supply and fixing bell push switch flush type universal single pole 5Amp, 230Volt.
6
-
-
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling fan flush type.
35
-
-
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
380
-
-
Supply and Fixing Ding Dong bell AC 230 volts,single pole.
33
-
-
Supply and Fixing 5/6 Amps bell push one modular switch complete.
33
-
-
Supply & Fixing 5/6 Amps 1 way one modular switch complete.
1515
-
-
Supply and Fixing 5/6 Amps three pin socket modular complete.
220
-
-
Supply and Fixing 15/16 Amps one way one modular switch complete.
35
-
-
Supply and Fixing 15/16 Amps three pin socket modular complete.
55
-
-
Supply and Fixing 5 Amps 2 way modular switch complete.
60
-
-
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed.
210
-
-
Disconnection and removing the u/s LED lamp and S&F invertor LED lamp 15 watts complete all as specified and directed.
230
-
-
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete all as specified and as directed.
120
-
-
S&F MCB DB, SPN, 4 way with 200 Amps 240 volts rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
16
-
-
S&F MCB DB, SPN, 8 way with 200 Amps rated 240 volts copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
25
-
-
S&F MCB DB, SPN, 12 way with 200 Amps rated 240 volts copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
24
-
-
S&F MCB DB, TPN, 4 way with 200 Amps rated 415 volts copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
12
-
-
S&F MCB SP 6-30 Amps 230 volts 10 KA ISI marked complete all as specified and as directed.
305
-
-
All as per Item No 45 here in above but of capacity MCB DP 40 Amps
50
-
-
All as per Item No 45 here in above but of capacity MCB DP 63 Amps
70
-
-
All as per Item No 45 here in above but of capacity MCB SPN 63 Amps
40
-
-
All as per Item No 45 here in above but of capacity MCB TPN 32 Amps
20
-
-
All as per Item No 45 here in above but of capacity MCB TPN 40 Amps
24
-
-
All as per Item No 45 here in above but of capacity MCB TPN 63 Amps
20
-
-
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral Enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
31
-
-
Disconnection and removing the u/s light fitting and S&F batten with LED tube light 1X18/20 watts LED, 230Volt energy saving recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
1176
-
-
Disconnection and removing the u/s LED lamp and S&F LED lamp 9/12 watts complete all as spfd and directed.
400
-
-
Disconnection and removing the u/s LED lamp and S&F invertor LED lamp 9/12 watts complete all as specified and as directed.
350
-
-
Disconnection and removing the u/s light fitting and S&F surface mounting mirror light luminaire 10 watts LED, 230Volt energy saving accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer-in-Charge.
150
-
-
Disconnection and removing the u/s light fitting from the fall ceiling carefully and S&F LED (2X2) indirect light fitting circular shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size and colour all as specified by Engr-in-Charge.
60
-
-
S&F decorative Post top LED 40 Watt for 360* indirect light with IP 65 protection 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
12
-
-
Disconnection and removing the u/s light fitting from the Surface mountend carefully and S&F Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
52
-
-
S&F as in repair batten LED 22 w inveter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 more than, driver efficiency ≥ 85%, operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge.
400
-
-
Supply and fix in repair MCCB 4 pole 100 Amps 35 KA complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
4
-
-
All as per Item No 61 here in above but of capacity 4 pole 160 amps, 36 KA.
3
-
-
All as per Item No 61 here in above but of capacity MCCB 3 pole, 125 Amp, 36KA.
3
-
-
All as per Item No 61 here in above but of capacity MCCB 3 pole 100 Amp, 25KA.
6
-
-
All as per Item No 61 here in above but of capacity MCCB 3 pole 63 Amp, 25KA.
8
-
-
Disconnection & taking down the unserviceable building light high wattage (35 Watts) street light fittings and Supply & fixing energy efficient Intergral type LED 25W Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted testing compelte all as specified and directed.
15
-
-
Disconnection & taking down the unserviceable GI bracket of size 25/32 mm dia from the pole / building and M&L for street light bracket made out of 25/32 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x6mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/building complete all as specified and as directed.
20
-
-
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s and M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 2.25 mtr below normal ground level, connected to GI wire 4cmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, GI protection pipe of size 20 mm dia upto 7.5 mtr length , funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
50
-
-
Repair and servicing of LT panel board of size as per side required by cleaning complete with carbon Tetra chloride solution, replacement of thimbles/ over heated cable pecies/ servicing of starter etc (at elect installed at different locations) including painting complete with two coats of synthetic enameld paint over a coat of red oxide paint after properly prepration of surface and carrying out following jobs of renewal :- (a) Internal wiring of suitable size.
(b) Volt meter 0-500 volt with selector switch - 01 No.
(c) Amp meter 0-50 A with slector switch and CT of suitable ratio -01 No.
(d) MCB TPN 63 Amp - 01 No.
20
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 6 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular.
515
-
-
Shifting of old LT Panel and making electric connections incl wiring by Conductor multistranded PVC insulated welding of doors , fixing hinges, Thimble Refixing of MCCBs and brazing etc incl complete all as specified and diercted by Engineer-in-Charge
2
-
-
Disconnecting and removing u/s Change Over and S&F of Change over switch 63 Amps, TPN, 415 volts rewirable fuse type complete all as specified and diercted by Engineer-in-Charge.
10
-
-
Supply and fix 4module (gang box) plastic surface box with plate.
16
-
-
Supply and fix 6module (gang box) plastic surface box with plate.
9
-
-
Supply and fix 8module (gang box) plastic surface box with plate.
11
-
-
Taking down existing control board (Meter Box) and supply and fixing sheet metal board made of 1.6mm thick metal sheet and painting 2 coats with synthic enamel paint over a coat of primer including copper bus bar and fixed with wall for fixing meter complete with wiring, fitting and accessories, locking arrangements with handle (minimum size of box 65cmx75cm and adequate depth for the following equipments, internal wiring and termination of external cable, lugs and glands and conduits as required) comprising of following. (a) Incoming 100Amp 4 pole MCCB 25 KA-01 Nos. (b) Bus bar 100 Amp Aluminium (d) 10Amp DP MCB-01 No (Outgoing for stair case and garage) (c ) 40Amp DP MCB-04 Nos (for Qtr meters) (e) Fixing only arrangement for electronic type energy meters single phase 240Volt 40Amps 50HZ -04Nos. Note : Elect meter will be issued under Sch 'B' free for fixing only.
10
-
-
Supply and Fixing step type electronic modular fan regulator of capacity 120 watts-2 module 230 volts for ceiling fan.
135
-
-
M&L for Sub main wiring/power wiring complete with two runs of 10.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated, 10.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. MAKE : Polycab / Finolex / havells NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
200
-
-