Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date12 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Summary

Repairs/maintenance Incl Perriodical Testing Of Fire Fightingof Fire Fighting

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix in repair brass female coupler for fire hydrand of size 63 mm complete all as specified and as directed.

12

-

-

... More
Supply and fix in repair canvas hose 63 mm with brass male and female coupler 15 Mtr long conforming to IS-636 complete with male and female coupling conforming to IS-903 complete all as specified and directed.

10

-

-

... More
Supply and fix in repair pressure switch complete all as specified and as directed.

2

-

-

... More
Supply only Branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and as directed.

5

-

-

... More
Supply and fixing in replacement of cast iron sluice valve heavy duty class PN-1.6 conforming to IS 14846-2000 with flanged ends 150 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber /fiber board gasket nuts, washers etc,suitable for fire fighting pressurised pipe line including necessary excavation, returning and filling complete all as specified and directed .

2

-

-

... More
Supply and fix in repair CI stainer 150 mm dia for suction line complete all as specified and as directed.

2

-

-

... More
Supply and fix in repair fire brigade inlet connection 2 way complete all as specified and as directed.

2

-

-

... More
Supply and fix in repair fire brigade inlet connection 3 way complete all as specified and as directed

1

-

-

... More
Supply and fix in repair fire brigade inlet connection 4 way complete all as specified and as directed

1

-

-

... More
Supplying & Fixing of standard Fireman's Axe with heavy insulated handle conforming to (IS:926) complete all as specified and directed.

5

-

-

... More
Supply and fix heavy duty MS ERW pipe of size 150 mm dia plane end duly welded and painted with one coat of red oxide as primer and two coats of synthetic enamel paint of colour post red complete all as specified and as directed.

22

-

-

... More
Supply & fixing in replacement of 25 mm dia (Nominal Bore) M.S PIPE Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed.

50

-

-

... More
Supply & fixing in replacement of 50 mm dia (Nominal Bore) M.S PIPE Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed.

40

-

-

... More
Supply & fixing in replacement of 80 mm dia (Nominal Bore) M.S PIPE Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed.

20

-

-

... More
Supply & fixing in replacement of 100 mm dia (Nominal Bore) M.S PIPE Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed.

30

-

-

... More
Supply & fixing in replacement of two coat of 4 mm thick 'PYPKOTE' antirust protection including primer and lap of 25 mm on M.S. pipe in trenches or complete including surface preparation coating and wrapping shall be confirm to ISI 10221 including conducting Holiday Test complete all as specified and directed.

250

-

-

... More
Supply & fixing in replacement of 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type A with S.S. male & female instantaneous type coupling (IS 903) complete all as specified and directed.

10

-

-

... More
Supply & fixing in replacement of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete block as and when required.hose reel of 20 mm dia and 30 meter length confirming to IS 8090 . Make :- MEC/NEWAGE/ATASEE

8

-

-

... More
Supply & fixing in replacement of weather proof standard fire hose cabinet for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing - 2 No. Hose pipe,-1 No. branch pipe & nozzle spanner complete all as specified and directed .

10

-

-

... More
Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of 100 mm bore size complete all as specified and directed.

2

-

-

... More
Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of 80 mm bore size complete all as specified and directed.

2

-

-

... More
Supply & fixing in replacement of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers ISI Marked of 100 mm bore size complete all as specified and directed.

5

-

-

... More
Supply & fixing in replacement of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers ISI Marked of 80 mm bore size complete all as specified and directed.

4

-

-

... More
Supply & fixing in replacement of dual plate non-return valve complete with nuts, bolts and washers.

-

-

-

... More
Supply & fixing in replacement of dual plate non-return valve 100 mm dia complete with nuts, bolts and washers complete all as specified and directed.

6

-

-

... More
Supply & fixing in replacement of dual plate non-return valve 80 mm dia complete with nuts, bolts and washers complete all as specified and directed.

3

-

-

... More
Supply & fixing in replacement of air release valve of 25 mm dia and 25 mm dia gun metal gate valve with fittings etc. to be installed at risers.

4

-

-

... More
Supply & fixing in replacement of burden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. (For each internal Fire hose cabinet) Dial Diameter : 100 mm Caliberation : 0-10 Kg/cm2 complete all as specified and directed.

4

-

-

... More
Supply and fixing of framed brackets of angles cut to shaps drilled and cuontersunk for screw, including bending and welding angles as necessary, confirming to Fe.290 Grade complete all as specified and directed.

100

-

-

... More
Disconnecting fire fighting centrifugal booster pump set of capacity 110 HP from foundation and suction/delivery line and star delta cable connection. Disconnecting of electric motor and pump from MS coupling for removing the pump and motor from foundation to outside the pump room complete all as specified and directed.

1

-

-

... More
Making necessary arrangement for lifting of electric motor 3 phase 415 volts 50 HZ of capacity 110 HP from pump room (below 4.5 mtr to the ground level ) carefully with out damaging motor and building and transporting the same to workshop for repair and repositioning of motor with with pump after repair complete all as specified and directed.

1

-

-

... More
Strip opening of motor of capacity 110 HP 3 phase for assessment of repair work cutting of damaged winding , taking out unsv ball bearing etc and Cleaning of motor rotor and stator with cleaning material. Machining work complete including remateling of rotor shaft etc. replaceemnt of bearing and bush and rewinding of motor with stove enamelled insulated copper wire of existing gauge. Repalcement of unserviceable parts as required. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge.

1

-

-

... More
M & L for opening and servicing of Monoblock pump of capacity 12.5 HP to 15 HP after dismantling from existing platform by disconnecting electric and water connection of pump set , decoupling pump & motor and transportation to work shop and opening the body of motor, oiling greasing of motor & pump set ,replacement of bearing, replacement of mechanical seals of pumps, replacement of bearing, overhauling of pump with proper alignment of pump including all necessary nut, bolts ,welding works and rubber coupling if required for setting of pump & motor complete all as specified and directed.

3

-

-

... More
Strip opening of induction motor 15 HP 3 phase 415 volts 50 HZ and taking out burnt out windings . Cleaning of motor rotor and stator with cleaning material. Machining work complete including remateling of rotor shaft etc. replaceemnt of bearing and bush and rewinding of motor with stove enamelled insulated copper wire of existing gauge . Repalcement of unserviceable parts as required. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge.

3

-

-

... More
Supply and instalation ECO FIRE ABC powder type (Stored pressure )Fire Extinguisher 4 Kgs conforming to IS code -15683 operating tmperature 0⁰ tto + 55 ⁰ and fire rating 2A &21B type of fire filled with MAP Powder complete in all respect and 'A, B,C class fire inflammable liquids (Petrol, Kerosene, Paints, Diesel ) gasesous fire ,LPG and actylene and electrical fire , paper, cloth wood, complete all as specified and directed.

20

-

-

... More
Supply and fixing of brass hydrant brass/bronze valve of 100 mm size single headed, complete all as specified and directed.

5

-

-

... More
Supply and fixing brass hydrant bronze valve of 80 mm size single headed, complete all as specified and directed.

4

-

-

... More
S&F in replacement of Bronze/brass body foot valve 65mm nominal bore, conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed.

3

-

-

... More
S&F in replacement of Bronze/brass body foot valve 80mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed.

3

-

-

... More
S&F in replacement of Bronze/brass foot valve bronz/brass 100mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed.

3

-

-

... More
S&F in replacement of Cast Iron non return/reflex valve 150mm nominal bore with by pass arrangement duly ISI marked with nut, bolts, washers complete all as specified and directed.

3

-

-

... More
Material, labour and T&P for Cleaning of static water tank (Fire tank) of capacity 10000 gallons by tank clean process as below :- (a) Pumping out water from SWT and removing of sludge mechanically or mannualy and disposing it off at a distance of not less than 100 mtr from SWT . Cleaning of side walls and bottom surface by scrubing the deposite and removing the same. Cleaning of the walls with high pressure water jet and pumping out the dirty water . Sterilization of tank by eco-friendly degradable and highly effecting ( anti becteria and anti fungus chedmical) . Painting of the wall with two coats of cement basespaint over a coat of cement primer and writing date of painting /cleaning on the tank .

20

-

-

... More
All as per item Srl item No 39 here-in-before above but static water tank of cap 50000 gallons complete all as specified and directed.

2

-

-

... More
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 25 x 4 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia med grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.

23

-

-

... More
Excavation in trenches in any type of soil not exc 1.5 m wide and not exc 1.5 m deep for laying of pipes etc and getting out including cutting of grass and bushes complete all as specified and directed.

50

-

-

... More
Note : Excavation shall be carried out manually. Use of JCB for excavation in trenches will not be allowed in any case. 2. Any damage to existing underground electric cabdle HT/LT, Fiber Optic cable and pipe line shall be repair/make good by the contractor with in 24 hours of the damage failing which double to the amount of repair / making good shall be recovered from the contractor. No extra charges for making good of damage are admisible to the contractor from the department.

-

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified and directed.

5

-

-

... More
Removal of surplus soil to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 above the starting point complete all as specified and directed.

45

-

-

... More
M&L for arresting of water leakage from existing pipe line in position from GI pipe of following sizes 80 to 100mm bore ,including excavation through Men/Mechanical power ,cutting threading, welding as per site requirement, including fixing of jointing material such as GI ( Bend, socket, reducer, tee, furrel, union ,solution, thread etc) and refixing etc complete all as specified and directed Note:- (i) Excavation up to 1x1x6 Mtr shall be deem to included in quoted rates and excavation beyond this size shall be measured and paid separately. (ii) cost of Jointing material such as socket, bend, elbow, reducer, nipple , union and dummy plug required if any is deemed to be included in the quoted rates (iii) Complaint /breakdown in pipe line shall be attended and rectified within 6 hrs from receipt of complaint. Contractor shall be penalized @ 500/- per hrs for non compliance .

30

-

-

... More
All as per srl item No 45 here-in-before above but pipe size 40 to 50mm bore nominal bore complete all as specified and directed.

40

-

-

... More
All as per srl item No 45 above but pipe size 15 to 25mm bore nominal bore complete all as specified and directed. Note for Srl Item No 45 to 47 : Contractor will provide an experienced pipe fitter and helper alogwith tools required for repair to pipe line incl earth work during the currency of contract . Man power so deputed shall report to complaint cell water supply and collect complaint slip/job card in between 0900 to 1000 hrs and will deposite the same on rectification of complaint on the same day. Pipe fitter with helper not reported to complaint cell on any working day and any complaint left unattended due to non availability of man power contractor will be charges Rs 500/per complaint and amount will be recovered from the RAR.

60

-

-

... More
Supply only rubber gasket suitable for pipe of size 100/150 mm complete all as specified and as directed

120

-

-

... More
Supply only MS nuts and bolts long thread and washer for column pipe/CI pipe flanged type fittins complete all as specified and as directed

20

-

-

... More
S&F in repair power contractor 3 pole ML-4 conforming to cat part No SS-90910 of L&T with DC coil of AC3 rating 70 to 110 Amps suitable for motor including connection with new copper cable of suitable size and connection with new copper lugs and testing for smooth and trouble free running of starter on load, complete all as specified and directed.

2

-

-

... More
S&F in repair power contractor 3 pole Type MNX 95 (2NO+2NC) 3 pole of L&T cat part No CS 94136 with DC coil of rating AC-3 160 Amps suitable for motor including connection with new copper cable of suitable size and connection with new copper lugs and testing for smooth and trouble free running of starter on load complete all as specified and directed.

3

-

-

... More
S&F power contactor 3 pole ML- 2 of L& T with DC coil of AC-3 rating 60 Amps suitable for motor including connection with suitable size copper cable and removing unserviceable cable and connection with new copper lugs, nut bolts including taking out old unserviceable contactor form existing LT panel of pump house, complete all as specified and directed.

4

-

-

... More
All as per Srl Item No 52 here-in-before above but capacity 3 pole MNX 50 ( model as per site requirement) complete all as specified and directed.

4

-

-

... More
All as per Srl Item No 52 here-in-before above but capacity 3 pole MNX 70 ( model as per site requirement) complete all as specified and directed.

4

-

-

... More
All as per Item No 60 above but capacity 3 pole MNX 140 ( model as per site requirement) complete all as specified and directed.

4

-

-

... More
M & L for MCCB, TPN, 400 Amp, 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity 36 KA as in repair complete all as specified and as directed by Engineer-in –charge.

1

-

-

... More
M & L for MCCB, TPN, 250 Amp 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity 25 KA as in repair complete all as specified and as directed by Engineer-in –charge.

3

-

-

... More
M & L for MCCB, TPN, 200 Amp 415 volt , ISI marked adjustable type thermal magnetic release breaking capacity 25 KA as in repair complete all as specified and as directed by Engineer-in –charge.

3

-

-

... More
M & L for MCCB, TPN, 160 Amp 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity 25 KA as in repair complete all as specified and as directed by Engineer-in –charge.

3

-

-

... More
M & L for MCCB, TPN, 100 Amp 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity 16 KA as in repair complete all as specified and as directed by Engineer-in –charge. Note for item : Make and frame size of the new MCCB should be as per the existing unsv MCCB so that new MCCB can be fixed and connected properly in the panel

5

-

-

... More
Supply, fixing connecting and testing Motor protection unit (MPU) three phae 415 volt , 50 HZ ,automatic phase sequence corrector automatically correct input reverse phase, single phase protection, LV, HV, LIV, Auto of loft, timer, Dry running under & over current, unbalancing ,float switch with built in CTs (Automatic-RTM ) complete all as specified. & directed.

6

-

-

... More
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.

100

-

-

... More
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 120 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.

90

-

-

... More
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.

80

-

-

... More
M & L for sand filling using approved clean dry sand for cushioning of under ground cables incl spreading levelling and well ramming in layers not exc 25 cm complete all as specified and directed.

24

-

-

... More
Supply and laying of class 'B' bricks for under ground cable protection as directed by Engineer- in - charge

2.4

-

-

... More
S & F in repair 40 mm bore Tubes ‘light grade’ ISI marked galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified and directed.

25

-

-

... More
S & F in repair 50mm bore Tubes ‘light grade’ ISI marked galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified .

24

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 10 sqmm with copper thimble complete all as specified and as directed.

90

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 25 sqmm with copper thimble complete all as specified and as directed.

70

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 35 sqmm with copper thimble complete all as specified and as directed.

65

-

-

... More
S&F in repair PVC insulated multistranded copper cable of size 50 sqmm with copper thimble complete all as specified and as directed.

55

-

-

... More
Taking shutdown for LT panel Servicing/repair outdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rustedout,bus bar as per existing size and shape, control rewiring ,voltmeter ammeter,CTs, indicating lamps,selector switches,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands complete including scrapping of surfaces of LT panel, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed.

6

-

-

... More
Taking out unserviceable AMMETER from diffrent location supply and fix Ammeter square flush mounted digital type type of size 96x96mm of range 0-200 Amp, complete all as specified and directed by the Engr -in -charge.

8

-

-

... More
Taking out unserviceable VOLT METER from diffrent location supply and fix VOLTMETER square flush mounted analog type of size 96x96mm of range 0-500 Amp, complete all as specified and directed by the Engr -in -charge.

8

-

-

... More
Schedule of Credit

-

-

-121255



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.