Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696805_1Tender No
GE(AF)/CHD/T-53/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Point wiring for one /fan point/Exhaust fan point controlled by one switch one way drawn through and including non metalic rigid PVC conduit medium duty of 20 mm dia or higher , concealed type with all strandard fittings such as Tee junction, bends etc ,using FRLS PVC unsheathed multistrand copper conductor cable of 1.5 sqmm single core including 3 mm thick plastic laminated sheet cover over PVC / wooden Box for earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly ,complete all as specified and as directed by Engineer-in- Charge. Note : Wiring shall be done by using proper colour coding.
30
-
-
... More
All as per srl item No. 3 here-in-before but for One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq., complete all as specified and directed by Engineer-in-Charge. Note : Wiring shall be done by using proper colour coding.
50
-
-
... More
All as per srl item No. 3 here-in-before but for 05 Amp socket outlet on independent board, with cables 1.5 sq., complete all as specified and directed by Engineer-in-Charge. Note : Wiring shall be done by using proper colour coding.
60
-
-
... More
Point wiring for 15 Amps socket point controlled by one, one way switch using drawn through and including non metalic rigid PVC conduit medium duty of of 20 mm dia or higher with all strandard fittings such as Tee junction, bends etc ,using FRLS PVC unsheathed multistrand copper conductor cable of 4.0 sqmm single core including 3 mm thick plastic laminated sheet cover over PVC / wooden Box for earth continuity insulated PVC unsheathed(green colour) 4.0 sqmm copper earth wire connected to common earth dolly ,complete all as specified and as directed by Engineer-in- Charge. Note : Wiring shall be done by using proper colour coding.
71
-
-
... More
Switch piano, flush type single pole, one way 5 Amp , complete all as specified and directed by Engineer-in-Charge.
343
-
-
... More
Switch piano, flush type single pole, one way 15 Amp , complete all as specified and directed by Engineer-in-Charge.
71
-
-
... More
Socket outlet 3 pin, 5A, flush type, complete all as specified and directed by Engineer-in-Charge.
60
-
-
... More
Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , complete all as specified and directed by Engineer-in-Charge.
71
-
-
... More
Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type fixed as in replacment , complete all as specified and directed by Engineer-in-Charge.
29
-
-
... More
Ceiling Rose, 3 Phase/ PVC/ Polycarbonate, isolated body fixed as in replacment , complete all as specified and directed by Engineer-in-Charge.
170
-
-
... More
Ceiling fan regulator step type electronic for 1200/1400 mm sweep ceiling fan and connecting up fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
30
-
-
... More
MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA 'B' curve type to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
108
-
-
... More
MCB SPN, 32 Amps, ,240 Volts ,10 KA 'C' curve type to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
14
-
-
... More
Distribution box Double door type , SPN 12 way,with 200 amps rated bus bar, 240 Volts 50 HZ for MCBs, grouted flush to walls complete with IP 65 and metal double door ,epoxy powder coated fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
6
-
-
... More
Distribution box Double door type , SPN 8 way,with 200 amps rated bus bar, 240 Volts 50 HZ for MCBs, grouted flush to walls complete with IP 65 and metal double door ,epoxy powder coated fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
8
-
-
... More
Sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 6 ways with 200 Amp bus bar with IP43 protection fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
3
-
-
... More
MCCB 4 pole, 415 volts, 100 amps, 25 KA breaking capacity with fixed thermal and fixed magnetic relay fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
3
-
-
... More
Sheet metal enclosure factory made single pole & neutral with a two pin & earth plug and socket etc complete with provision for one single pole 'B' series MCB 20 Amps 240 volts fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
3
-
-
... More
LED light fitting,20 watt attractive wall/ ceiling mounted type complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
103
-
-
... More
Lamp holder PVC/ poly carbonate type with back plate suitable for batten fittings fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
30
-
-
... More
LED bulk head luminaire 1 x 10W with IP 65 & heat resistance complete prewired fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
20
-
-
... More
LED of 36W 2' X 2' CRCA deep drawn panel recssed mounting luminaire suitable for arm strong/grid/ POP ceiling with seperate electronic driver and high brightness SMD leds fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
30
-
-
... More
LED channel 10 watts with suitable for accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
20
-
-
... More
Sub main wiring with two single core 6.0 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 6.0 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully wiring for security light connection from junction box to security light in and including taking down carefully copper/Aluminium submain wiring of any size/core/type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of wall, floors and ceiling etc. to match with the original existing finishcomplete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 6.0 Sqmm ,1 run of PVC conduit & 1 run of 6.0 Sqmm cable will be measured as single run.
(ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
43
-
-
... More
Sub main wiring with two single core 4.0 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 4.0 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully wiring for security light connection from junction box to security light in and including taking down carefully copper/Aluminium submain wiring of any size/core/type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of wall, floors and ceiling etc. to match with the original existing finishcomplete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4.0 Sqmm ,1 run of PVC conduit & 1 run of 4.0 Sqmm cable will be measured as single run.
(ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
29
-
-
... More
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically with top edge of earth plate not less than 1.5m below normal ground level (depth of pit not less than 2.25m below normal ground level), earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire of 4mm dia (8 SWG) by means of GI bolts, nuts, check nuts & GI washers and other end of earth lead connected to main switch board or main control board or test point or equipment, earth lead protected by galvanized iron pipe light grade (ISI marked) 20mm bore, alongwith watering pipe 20mm bore GI medium grade (ISI marked of specified make), funnel with wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 and RCC cover all as shown in electrical plate No 3 of MES Schedule Part-I including testing on completion in and including taking out old unservicable earthing , complete all as specified and directed by Engineer-in-Charge. Notes:-
(i) Pit cover shall be 80mm thick pre-cast of RCC (1:1½:3) type A-1 reinforced with XPM not less than 4Kg/ Sqm.
(ii) PCC Chamber shall be constructed 500mm away from the edge of earth pit.
(iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.
(iv) Earth resistance should be less than 5 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
2
-
-
... More
Disconnecting from socket out lets Split type AC of capacity upto 2 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stablizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed.
10
-
-
... More
Disconnecting from socket out lets Split type AC of capacity upto 1.5 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stablizer, reinstalling the units to its original position, replacement of remote cell and testing , complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
Disconnecting elect connections of refrigerators of capacity upto 310 ltr from wall socket, servicing by dusting, cleaning of the appliance in all respect, rectfying gas leakage by applying necessary brazing, defrozing of the deep freezing unit, replacing of perished elect wires for proper connection from voltage stablizer/ wall socket, reinstalling the units to its original position, and testing , complete all as specified and directed by Engineer-in-Charge.
5
-
-
... More
Supply and charging refrigent gas R-22/307/32 in Acs , refriferators etc installed at various buildings including brazing and testing to the satisfaction of Engr in charge , complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Dismantling of old unserviceable compressor from refrigerator 300/310 ltr capacity., supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing, complete all as specified and directed by Engineer-in-Charge. Make of compressor : Carrier/Kirloskar/Voltas/Techumseh
2
-
-
... More
Dismantling of old unserviceable compressor from refrigerator 210/230 ltr capacity., supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing , complete all as specified and directed by Engineer-in-Charge. Make of compressor : Carrier/Kirloskar/Voltas/Techumseh
3
-
-
... More
Thermostat for Split/window type AC 1.5 Ton fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
6
-
-
... More
PCB of suitable size and configuration and as per sample for split type AC of capacity upto 2 TR fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
4
-
-
... More
Running capacitor 45 Mfd for air conditioner 2 ton capacity fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
6
-
-
... More
Running capacitor 36 Mfd for air conditioner 1.5 ton capacity fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
6
-
-
... More
Starting capacitor 100 to 120 Mfd for air conditioner 2/1.5 ton capacity fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
6
-
-
... More
LT electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2.0 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing in and including taking of unserviceable cable of any size from trenches, pipes, on pole, etc., , complete all as specified and directed by Engineer-in- Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
290
-
-
... More
All as per item No 40 here-in-before but size 16 sqmm 2.0 core , complete all as specified and as directed by Engineer-in- Charge. .
104
-
-
... More
All as per item No 40 here-in-before but size 35 sqmm 3.5 core , complete all as specified and as directed by Engineer-in- Charge. .
60
-
-
... More
All as per item No 40 here-in-before but size 50 sqmm 3.50 core , complete all as specified and as directed by Engineer-in- Charge. .
135
-
-
... More
All as per item No 40 here-in-before but size 95 sqmm 3.5 core , complete all as specified and as directed by Engineer-in- Charge. .
65
-
-
... More
All as per item No 40 here-in-before but size 95 sqmm 4.0 core , complete all as specified and as directed by Engineer-in- Charge. .
130
-
-
... More
All as per item No 40 here-in-before but size 150 sqmm 3.5 core , complete all as specified and as directed by Engineer-in- Charge. .
65
-
-
... More
Steel water tubing, 40 mm bore light grade ISI marked galvanized with all fittings laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etcfixed as in replacment of old unservicable pipe,compllete all as specified and as directed by Engineer-in-Charge.
220
-
-
... More
Steel water tubing, 80 mm bore light grade ISI marked galvanized with all fittings laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc fixed as in replacment of old unservicable pipe,compllete all as specified and as directed by Engineer-in-Charge.
54
-
-
... More
LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection in and including disconnecting and taking down of any type of street light fitting( LED ) from pole, complete all as specified and directed by Engineer-in-Charge.
30
-
-
... More
LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection in and including disconnecting and taking down of any type of street light fitting( LED ) from pole, complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection in and including disconnecting and taking down of any type of street light fitting( LED ) from pole, complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.in and including disconnecting and taking down of any type of street light fitting( LED ) from pole, complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia as in repair , complete all as specified and as directed by the Engineer-in-Charge.
1
-
-
... More
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mm x 6 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1, RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, in and including taking out old unservicable earthing , complete all as specified and directed by Engineer-in-Charge. Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.
(iv) Earth resistance shall be less than 3O hm. In case test results are not found below 3Ohm, complete earthing will be re-done without any extra cost to Govt.
2
-
-
... More
PVC sheathed (flexible) round industrial cable of 1.5 Sqmm with stranded copper conductor fixed as in replacment ,complete all as specified and directed by Engineer-in-Charge.
180
-
-
... More
Servicing & maintenance/repair of Indoor type 100 KVAR APFC panel board & checking connections between load devices and sensing devices else where located in separate panel to check sequence of supply and set in proper condition including removal of defective device such as CT sensing cable and power cable, repair replacement of fuses, fuse link, control fuses, push button, LED indicators, auto manual selector switch, current transformers and checking/replacing of defective cable lugs, patch work welding, replacement of defective door hinges and testing of capacitor panel obtaining in board power factor to 0.95 to 0.98 of capacitor panel ,complete all as specified and directed by Engineer-in-Charge.
Note: Replacement of major items will be measured and paid separately.
3
-
-
... More
All as per item No 56 here-in-before but 50 KVAR APFC panel.
3
-
-
... More
Power factor improvement static condenser (capacitors) of required capacity fixed as in replacment ,complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
Contactor MNX type, AC 3 phase, 50Hz capacity ML-2, 25Amps, 3 pole with standard coil in and including taking out old unservicable contrctopr,complete all as specified and directed by Engineer-in-Charge.
Make:L&T (MNX-9) or equivalent in makes specified in Appx of makes.
6
-
-
... More
Contactor MNX type, AC 3 phase, 50Hz capacity ML-2, 32Amps, 3 pole with standard coil in and including taking out old unservicable contrctopr,complete all as specified and directed by Engineer-in-Charge.
Make:L&T (MNX-32) or equivalent in makes specified in Appx of makes.
6
-
-
... More
Servicing & maintenance of DG sets of capacity 15 KVA to 100 KVA installed at different locations by authorised representative of company (approved by GE) including replacement of the following parts/ components to entire satisfaction of Engineer-in-Charge complete:-
(i) Draining out engine/ lubrication oil, flushing and pouring new engine oil after repair/ maintenance of DG set including supply and replacement of oil pan/ chamber gasket.
(ii) Supply and replacement of lubricant oil filter element as per existing. (iii) Supply and replacement of fuel filter element as per existing.
(iv) Topping up /filling up of radiator with K cool 10 Litres.
(v) General servicing of DG set by opening of tappet cover/ top cover, tappet clearance setting with injector timing adjustment, re-fixing of tappet/ top cover including supply and replacement of tappet cover packing set, shellac/ bostic tube.
(vi) Supply and replacement of element air cleaner as per existing.
(vii) Tightening of all electrical connection, AVR connections, alternator connection and panel connections.
(viii) Tightening of all the hoses, fuel connections & `V' belts.
(ix) Cleaning of silencer muffler, radiators.
(x) Checking & adjustment of battery terminals and taking out defective and supply and fix new battery terminal in replacement.
(xi) Testing of engine on load for 30 minutes.
(xii) Supply and replacement of fuel water separator as per existing.
(xiii) Checking of auto programming & manual processing.
Note: Supply only of spare parts required to be replaced shall be measured and paid separately.
6
-
-
... More
Supply only fuel filter for DG set capacity 15 KVA to 100 KVA.
6
-
-
... More
Supply only lubricant oil filter for DG set capacity 15 to 100 KVA.
6
-
-
... More
Supply only fan belt set for DG set capacity 15 KVA to 100 KVA.
6
-
-
... More
Supply only hose pipe set for DG set capacity 15 KVA to 100 KVA.
6
-
-
... More
Carbon bush and commutator of complete DG set of capacity 15 KVA to 100 KVA including necessary lath works to rotor to match with original alignment and position capacity fixed as in replacment ,complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Excavating in trenches in soft/loosec soil , not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engrineer-in-Charge. Notes: (i) Excavation shall be done carefully to avoid damage of existing cables/ pipes and protection covers.
(ii) Excavation work may be got carried out in short lengths for locating fault in underground cables at different locations.
35
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipe/cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
13
-
-
... More
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
22
-
-
... More
Steel water tubing, 20 mm bore medium grade ISI Marked, galvanized with all fittings laid in trenches in and including taking up or down existing tubing and connections, cleaning for re fixing or removal to store, complete all as specified and directed by Engineer-in-Charge.
Note for item No.70 to 75: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
50
-
-
... More
All as per item No 70 here in before but Steel water tubing of 25 mm bore , complete all as specified and directed by Engrineer-in-Charge.
32
-
-
... More
All as per item No 70 here in before but Steel water tubing of 40 mm bore , complete all as specified and directed by Engrineer-in-Charge.
35
-
-
... More
All as per item No 70 here in before but Steel water tubing of 50 mm bore , complete all as specified and directed by Engrineer-in-Charge.
55
-
-
... More
All as per item No 70 here in before but Steel water tubing of 80 mm bore , complete all as specified and directed by Engrineer-in-Charge.
45
-
-
... More
All as per item No 70 here in before but Steel water tubing of 100 mm bore , complete all as specified and directed by Engrineer-in-Charge.
35
-
-
... More
Gun metal glove or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia in and including taking up or down old unservicable gate valve , complete all as specified and directed by Engineer-in-Charge Note for item No.76 to 78 : Excavation & earthwork shall be measured & paid separately under appropriate item of this BOQ where ever required.
15
-
-
... More
All as per item No 76 here in before but of Gun metal glove or gate valves for 40 mm dia , complete all as specified and directed by Engrineer-in-Charge.
10
-
-
... More
All as per item No 76 here in before but of Gun metal glove or gate valves for 50 mm dia , complete all as specified and directed by Engrineer-in-Charge.
8
-
-
... More
Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 80 mm bore pipe in and including taking down of old unservicable sluice valve with all fittings,complete all as specified and directed by Engineer-in-Charge Note: For those sluice valves which are fixed with pillar of over head tank work involve such as breaking of RCC/lead flange joints will be deemed to be included in the quoted rates, contractor will also repair the demaged floor etc.to match with existing and Joints shall be measured & paid seperately.
5
-
-
... More
All as per item No 79 here in before but of Sluice valve PN-1.6 (ISI marked) of size 100mm bore pipe , complete all as specified and directed by Engrineer-in-Charge.
5
-
-
... More
Construction of valves pit chamber of size 600x600x600 mm (internal dimension), using 100 mm thick PCC (1:4:8) 40 mm graded crushed stone aggregate for foundation 15 cm thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:4 cement mortar PCC (1:2:4) type B1 coping with 20 mm graded agregate for grouting MS frame including 3 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame out of 40 x 40 x 6 mm thick angle iron including paintaing of steel surface with two coats of anti corrosive synthetic enamel paint over a coat of red oxide primers finishing coat including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs and including demolition/dismantling of existing cracked valve pit chamber or as all as shown in Drawining bearing No CEAF/STD -28/94 sheet 1/2 & dated 01.02.1994 ,complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
All as per item No 81 here in before but size of valves pit chamber 900x900x1050mm (internal dimension) , complete all as specified and directed by Engrineer-in-Charge.
6
-
-
... More
Cleaning and removing all scale/sludge and dirt from RCC semi under ground sump of capacity 25000 gallon and lime washing with two coats after necessary preparatory works and petty cement patch works including removing of debris and vegetations from the surroundings of sump location upto 3.0m width all around and recording of cleaning date and due date on wall with synthetic enamelled paint, ,complete all as specified and directed by Engineer-in- Charge.
2
-
-
... More
All as per item 83 here-in-before but capacity 10000 gallon,complete all as specified and directed by Engineer-in- Charge.
2
-
-
... More
Cleaning and removing all scale and dirt, etc from water tanks of capacity 5000ltrs, from mouths of circulating pipes and cleaning surrounding area of tanks upto 3.0m width all around, complete all as specified and directed by Engineer-in-Charge
15
-
-
... More
Disconnecting all pipe and electric connections from pumping set centrifugal monoblock 20 HP three phase, dismantling and taking out the defective motor to suitable workshop and taking out the complete copper windings and rewinding with super enamelled copper winding wire, varnishing, heating, replacement of ball bearings, re-assembling and fixing at site, reconnection of all pipe and electrical connections and testing, complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply Only Sodium Hypo chlorite (NaOCL) chemical confiriming to IS 1673/86 ( granular powdered form ) complete all as specifiedand directed by Engineer in charge . Note chemical solution shall be supplied by contractor as on requirment basis through out the currency of the of contract . There for the contractor shall procure the chemical solution in peiecemeal as per requiment . The material shall be deposited with AGE B/R kasauli and RV shall be prepared according ,Contractor shall also arrange independent testing of chemical from Govt authorized labotory at his own expence .The cost of testing shall be deemed to be included in the quoted rate payment of supply of sodiuim chlorite solution shall only be made on prodution of test report , complete all as specified and directed by Engineer-in-Charge.
110
-
-
... More
Pressure guage 0 to 25 bar display type anolog for 50 mm dia pipe line and 0-400 PSI fixed as in replacment , complete all as specified and directed by Engineer-in-Charge
3
-
-
... More
Water Meter Stainless steel Analog Kranti Water meter size 80 mm Flange End for industrial type class B in and including taking Down water Meter of size 80 mm dia any type complete and deposited to AGE MES Kasauli Store yard for further BER action , complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Water Meter Stainless steel Analog Kranti Water meter size 100 mm Flange End for industrial type class B in and including taking Down water Meter of size 100 mm dia any type complete and deposited to AGE MES Kasauli Store yard for further BER action , complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Note :Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%