Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Oct 2024
Closing Soon23 Nov 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681332_1Tender No
GE (AF) MC/CHD/T-29/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fix in replacement for earthing pit funnel and repair to earth pit with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, 80 mm thick reinforced XPM of weight not less than 4 Kg/Sqm and plaster work inner or outer etc, complete all as specified.
250
-
-
Supply only common salt for mixing with water for earthing pit complete all as specified and directed.
4000
-
-
Supply only Charcoal for earthing pit complete all as specified and directed.
100
-
-
Supply only Magnisium Sulphate (MgSo4) for earthing pit complete all as specified and directed.
1500
-
-
Supply and fix earthing indicator made out of Aluminium sheet of size 30 cm x 25 cm, 3mm thickness with support of flat iron frame of size 25 x 4 mm including necessary PCC work over and including one coat of synthetic enamel paint complete all as directed.
100
-
-
Supply Installation Testing & Commissioning of Ring Earth Pit which includes the installation of following.
(a) Digging /Auguring /Boring of Five Single Earth Pits of 100 mm to 125 mm dia to the depth of approx. 2.8 metre.
(b) Insertion of 17.2mm x 3000mm Earth Electrode of low carbon steel with molecularly bonding of electrolytic grade copper coating (purity 99.9%) having min. 250 microns thickness shall comply with Specification IEE 80- 2013 & IS 3043-2018 and penetrating it at least 0.2 metre by pushing gently with sledge hammer where the natural soil is assumed for all five pits.
(c) Filling of Earth pit with Earth Enhancement Compound (ITPC-EECP15) in slurry form and backfilling.
(d) Job of Exothermic Welding Material for bonding the earth system shall be as per RDSO specs, which includes graphite moulds, clamps weld metal powders.
(e) Carrying out exothermic weld connection job on the single earth electrode to a copper tape of 150 x 25 x 6 mm.
(f) Carrying out exothermic weld connection job on the copper tape of 150 x 25 x 6 mm of on master Earth Electrode for connecting two 35 Sqmm cables for redundancy.
(g) MEEB of size 300 x 25 x 6 mm is to be fixed inside the equipment room with two insulation studs.
(h) 300 x 300 x 300 mm (inside dimension) concrete Earth Pit with a concrete lid, approx. 50 mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written.
(j) Except the master earth pit all the remaining earth pits are to be buried in the ground.
11
-
-
(k)Digging of trench to min depth of 0.5 m and laying 20 x 3 mm bare copper tape connecting all the five Earth Pits.
(l) Routing and laying 20 x 3mm copper tape connecting all the five Earth Pits.
(m) Carrying out exothermic weld connections job on all the five Earth Electrodes to Copper tape of size 20 x 3 mm for interconnection of earth pits.
(n) It shall be ensured that the distance between any two earth electrodes shall be minimum 3 m and max. Upto twice the length of the Earth Electrode to avoid mutual resistance effects. Make : Kratonite/ITPC-Metchem/Ashlok/Sofamel/Inpocon/Maltep
-
-
-
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded crushed stone aggregate with precast RCC pit cover 80 mm thick reinforced XPM of weight not less than 4 Kg/Sqm thick etc including dismantling old earthing, complete all as directed and specified.
Note : The earth value/result must be less than 5 ohms.
20
-
-
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 25 x 4 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick reinforced XPM of weight not less than 4 Kg/Sqm etc including dismantling old earthing, complete all as directed and specified.
Note : The earth value/result must be less than 5 ohms.
30
-
-
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick reinforced XPM of weight not less than 4 Kg/Sqm etc including dismantling of old earthing, complete all as directed and specified.
Note : The earth value/result must be less than 5 ohms.
10
-
-
Material and labour for Earthing complete with copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including Copper strip 20 x 3 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick reinforced XPM of weight not less than 4 Kg/Sqm etc including dismantling of old earthing, complete all as directed and specified.
Note : The earth value/result must be less than 3 ohms.
30
-
-
Supply and fix in replacement of Air termination, single pointed aluminium rod 12mm dia and 300 mm long as per site requirement with saddle complete all as directed .
200
-
-
Supply and fixing of copper strip size 20 x 3 mm as earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
Note :- Porcelian/suitable insulators with nut, bolts, screws for fixing strip at the span of one meter and for fixing the strip on high rise bldgs not more than 20 Metres to be included in the quoted rate.
900
-
-
S&F in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal head screw complete all as directed.
40
-
-
S&F in replacement of Aluminium strip of size 25 x 3 mm as earth continuity conductor or main earthing lead to wall on insulator or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as directed.
Note :- Porcelian/suitable insulators with nut, bolts, screws for fixing strip at the span of one metre and for fixing the strip on high rise bldgs not more than 20 Metres to be included in the quoted rate.
1200
-
-
Supply and fixing in replacement of unserviceable LT Feeder Pillar Box out door type 1.1 KV made out of MS CRCA sheet of size 3.15 mm thick having 4 Nos Aluminium bus bar of size 200 Amps for phase and 100 Amps for neutral fixed on LT 8 Nos insulators of size 0.60Mx0.45M X 0.45M with 04 legs made out of MS angle 50X50X5 mm & 0.75 Metre in length with locking arrangements, front and back opening, including danger notice board with skull & bone monogram & indicating 1100 volts danger board and including PCC foundation with suitable PCC work in PCC 1:2:4 type B1 and earth work and incoming and out going connections and testing on completion, complete all as specified and directed.
5
-
-
Supply and fixing in replacement digital programmable astronomical time switch auto operation 220-240 V AC, 50 HZ and contactor of cap 63 Amp TP with enclosure and mounting arrangements/pcc foundation and excavation for erecting complete with complete wiring all as per site requirement for operating street/security lights, complete all as specified and directed. Make : Havells/Legrand/ABB
15
-
-
S&F in replacement of insulators with DMC insulators not more than size 32x6 mm size T type with nut bolts, screws for fixing of copper/aluminium/GI strip on wall or roof etc complete all as specified and directed.
500
-
-
Supply Erection, Testing and Commissioning in replacement of Automatic Power Factor Correction OEM built Capacitor Panel suitable for Indoor Application, 150 kAVR rating, 440 volts, 03 phase AC. APFC Panel shall be designed and manufactured by OEM only, all Components Make like MCCB, MPP Capacitors, Capacitor Duty Contactor, Reactors, APFC Relay, Wire, shall be of Same OEM including encapsulated Copper busbar, Pan Assembly shall be used for better heat dissipation and proper cooling, Outgoing MCB/MCCB must be directly mounted on the Pan Assembly to avoid any loose connection and short circuit, Capacitors shall be Super Heavy Duty type with high Overcurrent withstand capacity Capacitor Bank Size in 8 steps of (2x50 kVAr + 1x25 kVAr + 1x10 kVAr + 2x5 kVAr+ 1x3 kVAR+1x2kVAR) for real time compensation which makes systems Reliable and Sustainable, Dimension shall be of 1175x800x540 (H*W*D in mm) complete all as specified and directed. MAKE : HAVELLS cat No. QHXTCB5150X0 or equivallent in SCHNEIDER/ LEGRAND
2
-
-
Supply,install,testing and commissioning in replacement of CPRI approved factory made outdoor LT Panel/feeder piller box outdoor KIOSK type, designed PTA (partially type tested panel) with double doors provided with locking arrangements dust, vermin and water proof made out of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2mm thick CRCA sheet powder coated with back door detachable fixed with nuts, bolts and washers and front doors openable type fitted with hinges and knobs/locks. Panel is to be placed on angle (size 50x50x6mm) frame duly painted with two coats of synthetic enamel paint over a coat of primer to the portion visible to eye supported on 04 legs 750mm long each duly 450 mm grouted in PCC blocks of type 1:2:4 type B-1and 300mm above ground level for entry of cables suitable for 3-phase, 4-wire, 50Hz,415 volts,with and including necessary incoming and out going cable connection with proper size aluminium lugs, nut bolts etc , the panel shall be provided with TPN aluminium bus bar of suitable size and rating codified with RYB, including digital metering unit with selector switch(volt meter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. including Moulded Case Circuit Breakers (MCCB's) 630 Amp 36 kA I/C - one, O/G 400 AMP 25 kA -02, O/G 250 AMP 25 kA -01, all MCCBs with four pole 415Volts, 3 phase, 50 Hz AC with thermal magnetic based protection release and required breaking capacity with adjustable protection over load and short circuit and confirming to IEC 60947/IS 13947/Part-ii/1993 latest version. The MCCB should have Ics=100% Icu for short breaking capacity of required KA rms at 415 Volts 50 Hz AC. Make:Legrand DPX3, ABB Tmax (T2 series & above), Schneider NSX, L&T DSine (DN2 series & above)
1
-
-
Material and labour for Heat Shrink Sleeve suitable for LT cable of 240 to 400 Sqmm Industrial Grade with shrink ratio 2:1 Operating Temperature (°C): -40 to 125 complete all as specified and directed.
25
-
-
Material and labour for Heat Shrink Sleeve suitable for LT cable of 120 to 185 Sqmm Industrial Grade with shrink ratio 2:1 Operating Temperature (°C): -40 to 125 complete all as specified and directed.
25
-
-
Material and labour for Heat Shrink Sleeve suitable for HT cable of 95 to 240 Sqmm Industrial Grade with shrink ratio 2:1 Operating Temperature (°C): -40 to 125 complete all as specified and directed.
25
-
-
Material and labour for Heat Shrink Sleeve suitable for LT cable of 50 to 95 Sqmm Industrial Grade with shrink ratio 2:1 Operating Temperature (°C): -40 to 125 complete all as specified and directed.
25
-
-
Material and labour for Heat Shrink Sleeve suitable for LT cable of 10Sqmm to 35 Sqmm Industrial Grade with shrink ratio 2:1 Operating Temperature (°C): -40 to 125 complete all as specified and directed.
15
-
-
Supply and fixing 50 meter length, 10mm width, height 10mm not exceeding number of lamps 120 per meter with max wattage 6.5 / metre, IP 65 rating LED strip light for outdoor use warm light inclusive light fitting and driver, 230V, to be flexible design and customizable as per requirement complete all as specified. Make:- Philips/Wipro/Havells
6
-
-
Supply and fixing of online change over switch 630 Amps, four pole, 415 Volts, 50 Hz, Standard: IS: 13947 IEC 60947-3, including stailess steel enclosure and fixing with fastners/screws on wall including disconnecting of old Changeover switch with cables and reconnecting the cables in new changeover switch complete all as specified. Make: Havels Cat No. SKU: EL.CH.ON.1549454 or equivalent in Legrand/ABB/Schnider
1
-
-
Note:- Amount of credit of Rs. 218500.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%