Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date8 Dec 2023
Closing Date4 Jan 2024
Tender Amount₹ 46,25,000
Costs
EMD
₹ 92,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_631765_1Bid Award Id
ViewTender No
GE/CHD-70/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule A Notes, Schedule of Credit, Schedule B C D ,Special conditions, Particular specification and other connected documents.
BOQ Items
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 Sqm but n. exc 4.0sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified.
12
-
-
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots all as specified.
230
-
-
Demolitioin of cement conc in ground floors and pavings n.exc 15cms thickness (below or above GL).
18
-
-
Dismantiling timber scantling in fillets ,rail,posts,rafter ,purlins,etc under 40Sq.cm in section,Complete as per direcrtion of Engineer-In- Charge.
224
-
-
Dismantling wall and ceiling boards (fibre pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
80
-
-
Hardcore broken stone of gauge not exceeding 63mm deposited, spread & leveled in layers not exc 15cm thick watered, rolled and rammed to a true surface complete all as specified.
8
-
-
M&L for plain cement concrete (1:3:6), type C-1 using 20 mm graded stone aggregate as in Plinth protection,75mm thick finished even and fair, complete including necessary form work all as specified .
55
-
-
Forming contraction (dummy) joints 25 mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and as directed.
2
-
-
M&L for brick work with flyash bricks straight or curved on plan exc 6m mean radius built in CM (1:6) with old size bricks, complete all as specified and directed.
53
-
-
M&L for plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregate as in foundations, filling , mass concrete and sub base complete all as specified and as directed.
5
-
-
M&L for earth filling under floors incl spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all specified and as directed.
15
-
-
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all specified and as directed.
20
-
-
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all specified and as directed.
20
-
-
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all specified and as directed.
20
-
-
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all specified and as directed.
20
-
-
Excavating in trenches, (soft/loose soil) n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified.
124
-
-
Removal of excavated soil to a distance exc 250 metre and n.exc 500m depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified.
57
-
-
Returning and filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick using soft/disintegrated rock all specified and as directed.
67
-
-
M&L for RCC M-25 Design mix, using 20mm graded trap stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, the like, any thickness, above top of footing including attached pilaster and buttresses etc., complete all as specified and as directed.
17
-
-
M&L for RCC M-25 Design mix, using 20mm graded trap stone aggregate for concrete as in columns, pillars, piers, posts and struts etc.,complete all as specified and as directed.
9.64
-
-
M&L for RCC M-25 Design mix, using 20mm graded trap stone aggregate for concrete as in chhajjas, complete all as specified and as directed.
0.5
-
-
M&L for RCC M-25 Design mix, using 20mm graded stone aggregate for concrete as in slabs, floors, roofs, landings, balconies, canopies and shelves etc., complete all as specified and as directed
18.62
-
-
M&L for RCC M-25 Design mix, using 20mm graded trap stone aggregate for concrete as in beams, cantilevers, bressummers, lintels beyond 1.5m span etc., complete all as specified and as directed
11.27
-
-
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including attached pilaster and buttresses etc., complete all as specified and as directed.
84
-
-
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions of square or rectangular finished rough complete.
102
-
-
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces.
5
-
-
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slab, landings and similar work not exceeding 200mm thick, horizontal or sloping finished rough complete.
132
-
-
M&L for Formwork for sides & soffits of floor or roof beams including bressummers, lintels, cantilevers, shelves including soffits etc complete finished rough complete all as specified and directed.
88
-
-
S&F for TMT bars 10mm dia and over cut to length , bent to shape required including , cranking hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
6500
-
-
S&F for TMT bars 5mm dia and over upto and incl 10mm cut to length, bent to shape required including, cranking hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers, binders etc complete all as specified and directed.
2400
-
-
Material & labour for chequered cement concrete coloured tiles 20cm x 20cm x 25mm thick, with grey cement and pigment, jointed and pointed in neat cement slurry in floor laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
120
-
-
M&L 75 mm thick Cement concrete type D2,1:4:8 (40mm graded stone aggregate) as in sub base,path,floor, hardstanding complete as as specified and directed.
120
-
-
M&L for rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in cement mortar 1:4 (with WPC) including, complete all as specified. Note: WPC will be measured and paid separately.
160
-
-
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces ,in cement mortar1:4, (with WPC) in patches complete all as specified and as directed by Engr-in-Charge. Note: WPC will be measured and paid separately.
160
-
-
M&L for rendering 15 mm thick on brick work or concrete surfaces, in cement mortar 1:6, complete all as specified and as directed.
348
-
-
M&L for rendering 5 mm thick cement plaster in CM (1:3) on ceiling surfaces, complete all as specified and directed.
150
-
-
Supply only liquid integral water proofing compound all as specified and as directed.
10
-
-
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces in camouflaging pattern or in any other pattern , Complete all as specified and as directed.
235
-
-
Material & Labour for preparation of new plastered surfaces of walls and applying two coats of oil bond distemper over a coat of primer complete all as specified.
348
-
-
Material & Labour for preparation of new plastered surfaces of ceiling and applying three coat of white wash,complete all as specified.
150
-
-
M&L for preparation of new steel and iron surfaces of any description, not otherwise described two coats of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed.
60
-
-
S&F 4mm sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 sqm in each pane complete all as specified and directed.
4
-
-
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and and average width of aperture not more than 1.40mm fixed with stainless steel wire staples.
4
-
-
M&L for preparation and cleaning surfaces of cement concrete incl flashing and junction of parapets etc and applying APP based polymeric memberane min wt 3 Kg/Sqm and min 3 mm thick reinforced with non woven fabric with torch application over and including a coat of oil base bituminous primer and finally applying two coats of bitumenous aluminum paint @ 0.20 kg per sqm over APP membrane, complete all specified and directed.
85
-
-
M&L for Kota stone slab 20-25 mm as in floors etc laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade the slab including rubbing and polishing complete with and incl 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
200
-
-
M&L for kota slab 20-25 mm thick in risers of steps, skirting dado and pillar laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade the slab including rubbing and polishing complete with and incl backing coat 10mm thick in CM 1:4 complete all as specified and as directed.
12
-
-
M&L Glazed ceramic coloured,,tiles 300x200x7mm thick in vertical surfaces such as skirting,dados and risers to steps over and including 10mm thick in CM (1:4) complete all as specified and directed.
50
-
-
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
38
-
-
M & L Cement concrete type B -0, 1:2:4 (12.5mm graded stone aggregate) 25 mm thick, complete all as specified and directed.
200
-
-
M&L Cement concrete in surface channels and drains in cement concrete 1:3:6 type C2 (40mm graded stone aggregate) complete all as specified and directed.
2
-
-
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
5
-
-
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed.
170
-
-
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, valleys, gutters etc. fixed with self tapping screws complete all as specified and as directed.
30
-
-
S&F Fe-410-W(Gde E-250)quality B rolled mild steel in roof, as in posts trusses(Framed)trusses, purlin, crane gantries, as in posts, rails and framing(beam, tee, angle, channel or flat section)including distance pieces , cleats etc, complete all as specified and as directed.
1700
-
-
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; fascia gutter , framed balusters; walk ways; railings; and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
150
-
-
M& L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along externalwall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface ofthe sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified.
35
-
-
Providing and fixing False ceiling at all heights with fully perforated 12mm thick micro tegular edged or 10 mm thick square edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595mm X 595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476(part-4) -1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @120 gms per sqm incuding both sides) comprising of main-T runners of size 15mm X 32mm of length 3000 mm, Cross-T of size 15mm X 32mm of length 1200 mm and secondary intermediate cross T of size 15mm X 32mm of length 600mm to form grid module of size 600mm X 600mm, suspended from ceiling using galvanised mild steel items (galvanising @80 gms/sqm) I.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85X25X2mm. Galvanised iron perimeter wall angle of size 24mmX24mmX0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per direction of the Engineer-In-Charge.
80
-
-
Providing and fixing anodised aluminium work for door windows, ventilators, casement/sliding shutters and partitions with extruded built up standard tabular and other sections of approval make fixed with rawl plugs and screws or with fixing clips or with expansion hold fastner incl neceesary filling up of gaps at junctions at top bottom & sides with required PVC neoprene belt etc. Aluminium section shall be smooth rust free straight mitred and jointed mechanically where ever required including cleats angles, aluminium snap beading for glazing/panelling, CP brass/stainless steel screw incl providing hinges/pivot and making provision for fixing of fittings where ever required. (Note:- The rate is inclusive of rollers, Maruti locks/star locks, robber beading, rubber seal etc for sliding/casement shutters required for satisfactory operations of window/ventilators/doors or as directed by Engineer-in-Charge. 2. panel fillings other than aluminium filling and necessary fittings shall be measured and paid for seoparately under respective items.)
225
-
-
S&F Pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. including making good to existing surface jamb/floor complete in all respect including demolished flooring /tiles making jambs, giving existing type of surface finish etc so as to mach the existing surface, as specified
50
-
-
Supply and fix 35mm thick factory made plain framed, panelled shutters (two panels), with lock rail and panels of 9mm thick BWP commercial ply or of venered particle board 12mm thick with commercial veneering on both faces with rails and style of 2nd class hard wood. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
18
-
-
Supply and fix 2nd class hard wood factory made glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in clause 8.24 (a) of SSR Part-I; supplied and fitted to chowkhats complete all as specified and directed.
19
-
-
S&F stainless steel Butt hinge 100mm size,complete all as specified and directed.
42
-
-
S&F 150mm size, Stainless Steel, D type with back plate, handle and fixed with screws complete all as specified.
28
-
-
S&F aluminium anodised barrel tower bolts of extruded section 150 mm long,complete all as specified and directed.
13
-
-
S&F 300mm Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
7
-
-
M&L for preparing new wooden surface of any description over 10cm width or girth and painting with two coats of synthatic enamel paint over a coat of pink primer complete all as specified.
12
-
-
S&F 20-25mm mm dia curtain rod made of aluminium Pipe with decorative lining coating,including brackets and decorative balls / caps at both ends of rod with comp fittings complete all as specified and directed.
15
-
-
S & F Door strip (snake guard strip) minimum 18mm wide aluminium body and nylon brushes minimum 22mm wide alongwith screw fixing complete all as specified and directed.
7
-
-
S&F 110MM PVC SWR Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
6
-
-
S&F 110MM PVC SWR Bends any radius complete all as specified and as directed
4
-
-
M&L stone walling built in CM 1:6 of random rubble uncoursed, well bonded, solidly hearted built in retaining walls, abutment and sililar work complete all as specified and directed.
12
-
-
M&L stone walling built in CM 1:6 of random rubble uncoursed, well bonded, solidly hearted built in retaining walls, abutment and sililar work but except(old stone received) complete all as specified and directed.
20
-
-
M&L raised pointing(CM 1:4) to random or polygonal rubble, un coursed or brought upto courses complete all as specified and directed.
3
-
-
M&L providing for PCC 1:2:4 Type B0 using 12.5mm aggrgate as in coping, apex stone, complete all as specified and directed.
1.73
-
-
Demolition of Mud phuska, sand, tiles in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) throw outside as per Direction of Engr-In-Charge.
15
-
-
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including ,fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed.
69
-
-
Taking down MCB DB/AC Box/Meter box of any size and disposal under schedule of credit and making good disturbed surfaces all as specified and directed.
2
-
-
Taking down old unserviceable light fittings any type and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface all as directed.
27
-
-
M&L for point wiring using approved colour coding as per IS ( for Phase and neutral) with copper conductor 1.5 sqmm ( Cross sectional area) single core multistranded FRLS ,PVC insulated and unsheathed cable 1100 volts grade,conforming to IS drawn and including PVC concealed coduit with fittings ISI marked ,terminated in modular switch boxes incl 1.5 sqmm (cross sectional area ) single core ,multistranded ,FRLS PVC insulated and sheathed cable as earth continuity conductor connected to earth dolly for one light point control by one way switch complete all as specified and directed.Note: 1.colour code of wiring should be ( for phase ,red,neutral ,black & earth wire green) 2.Modular switch sockets fan regulators shall be measured and paid separately under respective items deemed to be included in the quoted rates.
42
-
-
- Ditto - all as per item No - 82 above but for one 3 pin 5 amp socket on same board all as directed.
10
-
-
- Ditto - all as per item No - 82 above but for one 3 pin 5 amp socket on indipendant board all as directed.
6
-
-
- Ditto - as per item No: 82 here in before but with 4 sqmm copper conductor for 15 amp socket with 2.5 sqmm earth continuity conductor.
11
-
-
Taking out /dismantling unsv Sub main wiring and S & F Sub main wiring with PVC insulated, FRLS cable 2 single core 6 Sq mm 1100 V grade with stranded copper conductor on and incl PVC rigid non metalic conduit (ISI marked) in concealed incl all specials like joint, elbow , Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4 sq mm for earth continuityconductor complete all as directed by Enginer-in-charge .
20
-
-
S&F of Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified and directed.
58
-
-
S&F of Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and directed.
16
-
-
S&F of Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified and directed.
11
-
-
S&F of Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed.
11
-
-
S&F of Modular Fan step Regulator electronic, 120 watts, 2 Module complete all as specified and directed.
7
-
-
S&F of Modular blanking plate suitable for 1 Module complete all as specified and directed.
4
-
-
S&F of Modular white cover plate incl Modular base frame & powder coated Modular sheet metal concealed box for 12/8 module complete all as specified and directed.
6
-
-
All as per Item No-93 above but 6/4 module complete all as specified and directed.
6
-
-
All as per Item No-93 above but 3 module complete all as specified and directed.
18
-
-
All as per Item No-93 above but 2 module complete all as specified and directed.
2
-
-
M&L ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
24
-
-
Supply and fix of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
8
-
-
Supply and fixing of 25 watt LED batten with opal diffuser ,IP20, battery backup upto 4 hrs.Fitting should have inbuilt 2 No's of Li-on battery of 2600mA each.Housing of fixture should be of extruded aluminium Efficacy of fixture 100LPW,PF0.9,THD30% complete all as specified and directed.
12
-
-
Supply and fixing of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. complete all as specified and directed.
3
-
-
Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as directed.
2
-
-
S&F of isolator DP 63 amp 230 Volt complete all as specified and directed.
2
-
-
S&F of isolator SP, 6-40 Amps, 230 Volts complete all as specified and directed.
14
-
-
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
12
-
-
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one
coat after cleaning all dust etc complete all as specified and directed by Engr-in-Charge.
7
-
-
Material and labour for road / path way any type (Concrete) cutting , including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed.
12
-
-
M&L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engr-in-Charge
1360
-
-
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
13
-
-
Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 part-1 of size 63 mm outer dia and 50 mm inner dia all as directed.
24
-
-
Supply, laying , jointing ,testing and commisioning LT underground cable 1100 volts grade XLPE insulated and steel strip or wire armoured heavy duty with multistranded aluminium conductor 25 Sqm 2 core size including taking out unserviceable complete all as specified and directed. Note:- (i) Excavation and earth work cable protection and sand cushioning shall be measured and paid seperately .
80
-
-
Supply and laying of GI tubing, medium grade, 40 mm bore dia as cable protection fixed on walls/poles/laid in trenches complete including dismantling corroded GI pipe all as specified and as directed.
6
-
-
Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth lead wire and protection pipe beyond 7.5m shall be measured and paid separately.
1
-
-
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm, 2 core making all incoming and out going connections through the lugs/thimbles complete all as specified and directed . Note :- Excavation & earth work shall be measured & paid separately under respective item of this schedule
150
-
-
Supply & install steel tublar pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 including making the holes on the pole (bottom and top) suitable size for drawing of aluminium wire 6 sqmm twin core for connection of security light fitting from junction box to light fittings including of one primer coat, one under coat and one finishing coat of silver paint all as specified and directed. NOTE : (i) Earth work and PCC work will be measured and paid separately under respective item of the schedule.
6
-
-
Supply and fix of security light fitting bracket made up of 25/32 mm dia medium grade pipe of length 0.9 mtr with bending in shape by hot or cold method with 2 nos 50x4 mm MS flate clamps with nut bolts and washer etc all as directed.
6
-
-
Meterial and labour for cement concrete in foundations for pole coping or any other work type B1 1:2:4 with 20mm graded crushed stone aggregate all as directed
0.25
-
-
Meterial and labour for cement concrete in foundations for pole or any other work type C2 1:3:6 with 40 mm graded crushed stone aggregate all as directed
3
-
-
Meterial and labour for cement concrete in foundations for pole or any other work type D2 1:4:8 with 40 mm graded crushed stone aggregate all as directed.
0.3
-
-
Supply and fixing LED Security light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and suitable for 25/32mm mounting GI Pipe bracket complete all as specified and directed.
6
-
-
Supply and fix of Junction box made out of thermo plastic material of size 240x130x110 mm with provision of single phase cable connector incomming and out going with MCB SP 6-32 amps for security light fitting/PTL IP 65 protection totally enclosed weather proof with cable entry along with GI clamps nut bolts & washer fixed on pole all as directed.
6
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section in service connections complete all as directed.
40
-
-
Evaluation Notes How It Works ?
Potential Partner