Northeast Frontier Railway Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Northeast Frontier Railway - NFR Tender

Works
Software and IT Solutions
Electronics Equipment
Telecommunication Services
Electrical and Electronics
Ireps
Opening Date16 Apr 2025
Closing Soon8 May 2025
Tender Amount₹ 2,64,03,724 
Notes
Download

AI Insights

Bid Capacity
... View More
The formula for bid capacity is: The arithmetic sum of individual “Bid capacity” of all the members shall be taken as JV’s “Bid capacity”.
Technical Capacity
... View More
The required prior work experience for the bidder includes having successfully completed or substantially completed one of the following categories of work: (i) Three similar works each costing not less than 30% of the advertised value of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of the tender, (iii) One similar work costing not less than 60% of the advertised value of the tender. For subcontractors, they shall have successfully completed at least one work similar to the work proposed for subcontract, costing not less than 35% value of work to be subletted, in the last 5 years. However, for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for.

Costs

Summary

Signal And Telecom Work For Construction Of One Goods Line Beside Line No. 03 With Direct Reception And Dispatch Facility At Jag

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PC based Work Station for Data input and configuration, simulation and functional testing, diagnostics and trouble shooting and commissioning of EI system.

1

171036

171036

... More
Supply and installation of earthing of Electronic Interlocking Equipment as per RDSO's 5 drawing along with supply of all required materials (with minimum 10 no of rods). Painting of earthing diagram as replica of the ground on backside wall of relay room as per the instruction of Site In- charge.

1

600574

600574

... More
Providing of suitable arrangement including safety for UFSBI block Instrument in SM's 1 Room. The table shall be Box Type with two compartment of good quality wood with min 15 mm thickness as per approved by supervisor In charge. Approximate measurement will be 750 mm (L) X 550 mm (Depth) X 800 mm (Height) (Number means per block panel)

2

40624

81248

... More
Supply of CAT-6 cable for data connection between UFSBI and HASSDAC to OFC room

-

-

2

... More
Wiring of UFSBI from Relay rack to UFSBI (each station means 2 no of UFSBI)

-

-

3

... More
Supply, installation, testing and commissioning of Automatic Fire detection and Alarm systems for Signalling and Telecom Installations as per RDSO's specification No. RDSO/SPN/217/2021 4 Version No.: 3.0 or latest. NOTE: Procurement of Automatic Fire Alarm System to be done from RDSO Approved Sources. Scope of work includes provision of remote monitoring of Automatic Fire Alarm system at locations approved by Engineer-in charge, issuance of OEM certificate, issuance of pre- commissioning check list jointly signed with division

-

-

853682

... More
Supply and installation of CO2 type fire extinguisher of capacity 4.5 Kg as per IS Standard having ISI mark

5

10441

52205

... More
Supply of Microcontroller based Universal Digital Earth Leakage Detector (Make: Anuvidyut Type 905D or similar) comprising of 12 -Channels for signalling circuits (AC and DC) with stand for installation and safety fuse board for ELD.

1

157374

157374

... More
Installation of Microcontroller based universal digital Earth Leakage Detector comprise of 12 channels including connection to data logger for fault generation

1

7282

7282

... More
Tag block 200 way / 160 way with PVC transparent covers as per (IRS (S) 77/06 (Rev.1) and Drg.no.SA-24751 and 52.

5

1956

9780

... More
Installation and wiring of Power supply arrangement including laddering and drawing of wires from IPS etc. as per TS (Ladder and necessary consumable to be supplied by the contractor).

1

47370

47370

... More
Relay, AC immunized, Plug-in type, Style QNA1 DC Neutral line 24V, 8F-8B contact, front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to Spec: BRS:931A ; IRS S 34 ; IRS S 23 ;IRS S 60-78

40

4710

188400

... More
Preparation of Signaling documents SIP, VDUD, and RCC in Auto CAD as per standard 11 format adopted in NFR. Softcopy in AutoCAD to be submitted with six print copies of each in PDF format or as per instruction of supervisor in charge for further approval from competent authority. The scope of work includes subsequent modification and revision in SIP, VDUD, RCC till commissioning of projects

1

59015

59015

... More
Preparation and supply of six set of all completion drawings including circuit diagrams and indoor and outdoor documents as per TS

1

53150

53150

... More
Non detoriating type of low voltage electric fuse 2A along with base for railway signalling as per specification IRS: S-78/2006 or latest

100

135

13500

... More
Non detoriating type of low voltage electric fuse of 6A along with base for railway signalling as per specification IRS: S-78/2006 or latest.

50

238

11900

... More
Supply of Polymeric Positive Temperature Co-Efficient self-Restoring Type fuse (PPTC) 15 of 4/6 Amps capacity Fuse (for TF and TR circuit) should have an insulating coating of flame retardant epoxy to meet UL-94, V0 requirement working temperature range 40 Degree Celsius to 85 Degree Celsius and leads to be tin platted copper.

200

10

2000

... More
Supply of Polymeric Positive Temperature Co-Efficient self-Restoring Type fuse (PPTC) 16 Fuse (2-3 Amps) should have an insulating coating of flame retardant epoxy to meet UL-94, V0 requirement working temperature range 40 Degree Celsius to 85 Degree Celsius and leads to be tin platted copper.

200

10

2000

... More
16/0.2mm size tinned flexible single core indoor wire to IRS:S-76/89, PVC coated in different colours and to be supplied in coils of 100 meters. Material to be procured by RDSO approved firm with manufacturer test certificate

100

942

94200

... More
Supply of PVC Insulated Multicore copper conductor Indoor Cable 40 Core x 0.6 mm diameter as per Specification No. IRS:S-76/89 or latest

1000

152

152000

... More
Supply of PVC insulated unsheathed single core bright annealed bare copper conductor flexible cable for voltage grade up-to 1100V confirming to IS: 694/1990 or latest. (In the coil of 100 metres)

-

-

214468

... More
ARA terminal block 6 Way made of PBT/poly carbonate as per specification No. IRS:S 75/2006 (Rev.2) and drg No. 23756 or latest

100

375

37500

... More
Disconnect Terminal block for Four conductor with screw less Cage Clamp type/sliding 21 switch disconnect as per RDSO Specification No. RDSO/SPN/189/2004 version 3.0 (for each conductor size upto 2.5 sq. mm). Each Terminal block equipped with two markers on top and bottom, an end plate, 2 end clamps and adequate length din rails for fitting terminal blocks.

1500

206

309000

... More
Supply of Active lightning arrestor of Class A for building protection as per RDSO latest 22 guidelines, It shall work on Early Streamer Emission principle and shall be made of Stain less with a T of 60 micro second or less along with non-resettable type counter to count the number of lightning occurrences. The dimensions of the device shall be 590 mm x 120 mm or as directed by Engineer in charge.

1

107762

107762

... More
Supply of 25x3 mm Copper strip

-

-

23

... More
Installation of Class A device on the top of the building. The device shall be installed at a height of about 10 mtrs from the roof of the building using a GI mast. The device shall be connected to the earth pit using the copper tape of 25 x 3 mm exothermically welded to the Down Rod.

1

14440

14440

... More
Key locked rotary relay KLCR working on 24 V DC (AC Immunized)

-

-

25

... More
Supply and Installation of KLCR box for fixing of KLCR inside box, including supply of all materials like board, handle, hinges, Godrej type padlock, glass sheets, supporting brackets etc

5

4880

24400

... More
Supply of Fibre Distribution Management System (fibre Enclosure) for 24 fibres LIU loaded with 24* nos. Pigtails and Adapter as per RDSO Specification no RDSO/SPN/TC/37/2000 (Ver.3) Amdt.2

2

20666

41332

... More
Supply of OFC joint Enclosure as per TS

-

-

28

... More
Supply of Optical Pigtail cables each 20 mtrs long as per TS.

-

-

29

... More
Installation of OFC joint enclosure and splicing of optical fibre cable as per TS

5

7156

35780

... More
Supply of office chair Godrej Mid Back fabric Office Arm Chair or similar

-

-

31

... More
Supply of work station table -Godrej Enterprise Table Model No. ENT PR001 DX or similar

4

21698

86792

... More
Supply of Steel Almirah store wel plain full size of Godrej make.

-

-

33

... More
4.6 mtr Post with base, ladder. Ladder base, platform for CLS unit as per IRS specification No. IRS; S 6-81 and Drg. no. SA-23153 (Adv). S-2011/M or latest

2

23031

46062

... More
3.6 mtr Post with base, ladder. Ladder base, platform for CLS unit as per IRS specification No. IRS; S 6-81 and Drg. no. SA-23150 (Adv) S-2011/M or latest

11

21723

238953

... More
Colour light signal complete with 3 aspect unit FRP TYPE to Drg. no. IRS:S-26/64, SA 23002 A/M (Adv.) or latest without CLS transformers, lenses, lamps, lamp holders.

6

34527

207162

... More
Colour light signal 2 aspect unit FRP TYPE to Drg. no. IRS:S-26/64, SA 23003 A/M (Adv.) or with latest amendment without CLS transformers, lenses, lamps, lamp holders.

7

30609

214263

... More
FRP Direction type route indicator (2- Way), as per IRS: S-66/84 Amd. 1, SA 23401-6 (Adv.) or latest, complete with fixing arrangement, brackets, hoods and terminals but without lamps, lamp holders and lenses.

2

41402

82804

... More
FRP Calling-on signal unit complete with fixing clamps, terminals etc. as per as per RDSO drawing SA-24351 (Adv.) Alt-1 but without lamp, lamp holder and lens. Fixing arrangement shall be as per RDSO drawing SA-24352 (Adv)

2

9517

19034

... More
FRP Shunt Signal (Position light type) RDSO drg No. SA - 23840 (Adv.) with latest amendment for independent type complete with Signal unit, bracket, signal post of minimum 1 m length, surface base, terminals etc but without lenses, lamps and lamp holders.

3

21304

63912

... More
FRP Shunt Signal (Position light type) RDSO drg No. SA - 23840 (Adv.) with latest amendment for dependent type complete with Signal unit, bracket, terminals etc but without lenses, lamps and lamp holders.

6

15515

93090

... More
Offset bracket for colour light signal with fixing U clamps and nuts etc for Main Signal as per Drg No. SA 23080 Adv. or latest.

2

1834

3668

... More
Off set bracket for colour light signal with fixing U clamps and nuts etc for Shunt /Co- On

8

1924

15392

... More
Excavation, ramming, Casting Cement Concrete foundation for Colour Light Main Signal 11 Post in the ratio of 1:3:6 Aggregate not exceeding 3: 8 cm, as per IRSEM drg No. 19-D3, complete with contractor's material including cement, sand, aggregate, anchor bolts and nuts and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site.

13

8845

114985

... More
Excavation, ramming, Casting Cement Concrete foundation for Position Light Shunt 12 Signal Post in the ratio of 1:3:6 aggregate not exceeding 3: 8 cum, as per IRSEM drg. No. 19-D4, complete with contractor's material including cement, sand, aggregate, anchor bolts and nuts and curing of casted foundation, refilling and ramming of loose soil around foundation and disposal of loose dugged soil from site.

3

3433

10299

... More
Assembling, erection, installation, taking of cable inside unit through post, termination and wiring of CLS complete with all accessories of CLS unit, post, base, ladder, ladder guards, platform and MS supporting bracket in the middle of the ladder, hoods, pinnacles, offset brackets, Junction/stencil type route indicators (if any) - 1 way to 6 way, etc including fixing and wiring of LED units lamps with contractor's wiring material.

-

-

13

... More
Fabrication, supply and fixing of Retro-reflective P/ C/ A/ G marker disk of approved colours on signals, as per standard practice and technical specifications, with contractor's complete material including fixing clamps.

4

699

2796

... More
Fabrication, Supply and fixing of Retro-reflective Signal number plates of approved type as per technical specifications (Contractor has to arrange all hardware and other requirement to fix the plate on signal at his own cost)

24

323

7752

... More
Supply and fixing of Universal Lock suitable for fixing on CLS units, MACLS calling on signal unit, route indicator unit and Position light type Shunt Signal units and sufficient No of Keys.

24

171

4104

... More
Ground connections complete set (threaded type) for 143 mm stroke, Rotary Locking Point Machine, suitable to the point layout of 60 Kg. / 52 Kg Rails as per yard layout for BG and as per TS

7

8416

58912

... More
Points gauge tie plate insulation complete set complete with nut bolts etc.

-

-

18

... More
Point machine ground connection insulation complete set including for P Bracket and L bracket insulation as per IRS: S: 40/84.

14

428

5992

... More
Point's William stretcher bar insulation complete set

-

-

20

... More
Fixing of Electrical Point Machine on the extended sleepers at points as per standard practice with contractor's long fixing bolts, nuts and as per approved drawing for the section of rails 21 used, fixing ground connections and insulations, wiring inside the point machine with contractor's wiring material, supply and fixing of GI bend pipe with flange for taking cable into point machine, termination of tail cable in point machine and junction boxes, adjusting opening of the switches and adjusting the point machine with crank handle including all smithy and fitting works required at site for complete installation of Electric point machine Installation as per technical specifications.

7

11270

78890

... More
Supply of Plug in Type, metal to Carbon, DC Neutral Track Relay, ACI, Style QTA2, 9 Ohm, 2F-1B Contact complete with plug-board, retaining clip and connectors conforming as per: BRS:939A & 966 (Appx F2) & IRS:S-23, S34 & 60

16

4432

70912

... More
Supply of Plug in Type, metal to Carbon, AC Immunized, DC Biased Track Relay, Style QBAT, 9 Ohm, 2F-2B Contact complete with plug-board, retaining clip and connectors conforming as per specification No. RDSO/SPN/84 ver 2; IRS:S-23, S34 & 60-78,

6

8141

48846

... More
Supply of Track feed battery charger (capacity 10 Amps) to work on 110V AC for charging 1/2/3/4 lead acid cell of 80 AH used in track circuit as per Specification IRS:S-89/2013 Rev 1.0 or latest

22

5500

121000

... More
Track feed resistance (15/30 ohm) PBT base as per Drg.No. SA 20161-66/M

-

-

25

... More
B Type Choke Coil for single rail track circuits on 25 KV 50 Hz AC electrified sections as per specification IRS: S-65/83 amend.3 or latest

44

4146

182424

... More
Supply of Low maintenance lead acid stationary secondary cell as per specification no. IRS: S-88/2004 Rev.1 or latest amendment, nominal 2V, each of 80 AH with hard rubber container for use of Railway Signalling and Telecommunication application

66

3107

205062

... More
Charging of Secondary cells 80AH with Contractor's own charging equipment including supply of Sulphuric acid conforming to IS:266-1977, distilled water conforming to IS:1069-1964, installation, supply and application of acid proof foam spray of approved type, on the terminals of charges batteries, all activities as per Technical specifications and according to standard adopted for initial charging and installation of charged batteries in battery room in groups as per instructions of Engineer at site including supply of 5 Nos. of Hydrometer and 5 Nos. of Hydrometer stand make of superior quality wood as per instruction of site supervisors

-

-

28

... More
Track lead junction box FRP type fitted with 2-way in box size 120 mm x 220 mm x 90mm x6mm thick as per TS and as per drawing RST-11509

60

2509

150540

... More
PVC insulated cable 3/16" as per IRS specification S 103-2004 made of copper alloy material tin plated non corrosive.

500

210

105000

... More
Channel bond pin single grove

-

-

31

... More
Installation and commissioning of DC track circuits including fixing of continuity bonds on rail joints and making rail connections of lead wires, installation and fixing of track lead junction 32 box on MS angle for track feed end, track relay end and BX Jumpers, connections to tail cable, termination of tail cables on TLJB terminals etc., insertion of insulated block joints and also fixing jumper cables as per insulation diagram/track bonding plan, charging and adjustment of track circuit. All activities as per standard practice and as per instruction of site-in charge.

-

-

179922

... More
Supply and installations of wooden plank of size 305 mm (width) x approximately 25 34 mm (thickness), made from Sal wood or similar good quality commercial hard wood duly painted on all the surfaces, with two coats of acid proof paint for Battery racks in Battery room, at Location huts and locations, complete with contractor's material as per Technical specifications.

40

301

12040

... More
Apparatus cases Full made of 10 SWG sheets with miniature E Type Locks of same wards as that available on existing location box of station with keys as per RDSO Drg. No. S-11500 with latest amendments.

10

25662

256620

... More
Excavation, ramming, Casting Cement Concrete foundation for Apparatus cases/Location boxes (Full) in the ratio of 1:3:6 Aggregate not exceeding 3: 8 cm, as per approved 36 drawing with contractor's material including cement, sand, stones, anchor bolts and nuts and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site. It includes installation of apparatus cases on CC foundation on grouted bolts, including filling the space enclosed below the location box

15

10999

164985

... More
Supply and Installation of Hylum sheet (Size 1200 mm X 1200 mm) for termination of main/tail cable including supply of terminal board as per TS

15

3150

47250

... More
Termination of signalling cable/wire for Apparatus case (Full)as per TS

-

-

38

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6, aggregate not 39 exceeding 3 : 8 cm including excavation, raming, curing and plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate and curing of casted foundation, refilling and ramming of loose soil around foundation and disposal of loose dugged soil from site.

5

7249

36245

... More
Supply of Earth electrode for outdoor equipment as per TS. GI pipe shall consist of spike at one end and a lug at the other for connecting the earth lead wire.

30

2208

66240

... More
Installation of Earth Electrode including supply of MS flat (with peripheral earthing of apparatus case) for signalling equipment as apparatus cases, signal, relay rack etc.

30

3121

93630

... More
Supply, installation of glass fronted key box/crank handle lock up box .NOTE: Boxes should be of teak wood or good quality of 20-25 mm thickness as directed by site in charge.

-

-

42

... More
Installation, wiring, testing and commissioning of High availability Digital Axle Counter 43 for the block section / at station including its associated all indoor equipment indication panel, monitoring console / interface computer and wiring the same to integrate with the relay circuits as per the instruction of Railway engineer at site.

1

36994

36994

... More
A set of complete earthing system, maintenance free tripod type complete as per 44 RDSO/SPN/197/2008 with welded connecting rod and extension, copper cable for connection, Chemical Earthing with ultra-efficient Gel having earth impedance < 1 ohm for filling around earth electrode for BPAC euipment

2

62809

125618

... More
Installation, carrying out necessary digging work for fixing earth electrode in ground, Commissioning of complete earthing system, consisting of Copper rod/strip, extension, cable 45 connections, filling around earth electrode Chemical Earthing with ultra-efficient Gel having earth impedance < 1 ohm, all work of earthing as per standard practice and connecting it to equipment to be earthed, supply and providing copper earth lead wires multi strand lead wires, exothermic bonding with contractor's material all connections between earth electrodes and earthing, one end to earth electorde and the other end of the wire to equipment as per site requirements

2

7081

14162

... More
Excavation of trench 1.0 Meter deep and 0.3 Meter wide trenches in all type of soils 46 except rocky area including clearing of roots of trees and bushes and temporary obstruction and refilling of the trench by the excavated soil and ramming after laying of the required quantity of cables as per instruction of site in charge.

4000

71

284000

... More
Excavation of trench 1.0 Meter deep and 0.3 Meter wide trenches in rocky and ballast 47 filled soil, including clearing of roots of trees and bushes and temporary obstruction and refilling of the trench by the excavated soil and ramming after laying of the required quantity of cables as per instruction of site in charge.

400

526

210400

... More
Laying of Signal and Telecom Cable of different sizes as per cable route plan in the already dug trench with or without DWC pipe

35000

7

245000

... More
Supply and fixing of GI pipes/DWC pipes of all sizes and diameters/ troughing on culverts, bridges & any other loc. etc. complete with contractor's material including clamps, nuts and bolts and other fixing arrangements as directed by Engineer in charge.

60

1051

63060

... More
All works of excavation of cable trench 1.0 Meter deep, 0.3 Meter wide on pucca 50 platform/on Road for road crossing and restoration of the platform/Road surface to original condition with contractor's material, after laying of GI/DWC pipes and then re-filling the trench as per Technical Specifications.

200

668

133600

... More
Excavation of trench to a depth of 1 Mtr. for track crossing of cables, laying of 51 DWC/RCC/GI pipes with collar/coupler, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. NOTE: During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of the 1m trench shall be fron the bottom of the sleeper for track crossing.

50

333

16650

... More
Manual Boring at the depth of 1m across the track/road as per technical specification. DWC/HDPE pipe will be supplied by Railway.

250

354

88500

... More
Transportation of HDT machine with accessories including handling of store materials, preparation of site and boring for placing of different sizes of signalling cable together at 53 bridges/Culvert/Track/Pucca road crossing /Yard area /station area, boring trench shall be minimum 3 meters below the river bed below the river bed and minimum 1.5 meter below surface in other patches/track/road/pucca platform. It includes Pulling of Signalling cables by HDT machine (For 100 mm bore)

1000

1302

1302000

... More
Taking the all types of cables inside station relay rooms, location boxes and junction boxes etc and sealing of cable entry pit as per technical specifications, complete with contractor's material.

1

19794

19794

... More
Thermo shrinking jointing kit for jointing underground jelly filled Quad cable 4/6 Quad as per IRS: TC 77/2012 (Rev. 3.0) with Amdt. 3 or latest.

-

-

55

... More
Installation of Thermo shrinking jointing kit for jointing underground jelly filled Quad cable including testing & commissioning of Quad link.

10

1817

18170

... More
Supply of HDPE/DWC pipe outer diameter 90 mm, inner diameter 76 mm with sockets/couplers and T joints where required

100

250

25000

... More
Supply of HDPE/DWC pipe outer diameter 180 mm, inner diameter 152 mm with sockets/couplers and T joints where required

150

587

88050

... More
Supply and erection of Cable Termination Rack, Termination of cables, Frame, scaffolding/ladder/angle, oven baked and Powder Coated with Biscuit matt colour, corrosive resistant and final finish with Siemens Grey (Sigma) enamelled paint, complete as per approved drawing with 59 insulators, grouting bolts, tripods, rack fittings. ladder arrangement, hylam sheet board of 10mm thickness covering complete rack, all necessary fittings, supports, insulators, string rods to support cable, and other accessories etc as per Drawing and Tech Specs. and erection with scaffolding arrangement, fixing of tag block and all types of terminals on cable termination racks as per technical specification, in Relay Room and Location Huts. CTRs to be supplied of material same as Relay Racks

7

31504

220528

... More
Supply and installation of Stop Boards or calling on legend board, BSLB or other boards 60 as per approved drawing with reflective Strips/reflective paper, making necessary foundation as per instruction complete with contractor' material including angle for erection, supply and painting the board & post as per approved colour scheme complete installation

2

7608

15216

... More
Supply and installation of Goods Warning Board as per IRSEM Drg.No.12-D1 with 61 reflective Strips/reflective paper, making necessary foundation as per instruction complete with contractor' material including angle for erection, supply and painting the board and post as per approved colour scheme complete installation

2

11977

23954

... More
Supply of paints, primers, varnish and other painting material, complete painting and varnishing, lettering, numbering of all signalling gears, including signal posts and fittings, apparatus 62 cases, point machines, junction boxes, signal machine, rail post, other gears etc. complete at a station/mid-section gates/huts, letter writing on terminal Nos. apparatus cases, point machine, Signal Nos. and other details as per S.E.M., instructions of Engineer at site and as per technical specifications.

1

72292

72292

... More
Dismantling of released materials and transportation along with surplus materials up to consignee's Go down by truck including loading and unloading as per instruction by consignee.

1

23497

23497



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.