Military Engineer Services Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 8,76,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR / REPLACEMENT OF INTERNAL WIRING AND CONNECTED WORKS AT CERTAIN MD ACCN IN DOMESTIC AREA AT AF STN PURNEA UNDER AGE (I) (AF) PURNEA
REPAIR / REPLACEMENT OF INTERNAL WIRING AND CONNECTED WORKS AT CERTAIN MD ACCN IN DOMESTIC AREA AT AF STN PURNEA UNDER AGE (I) (AF) PURNEA
REPAIR REPLACEMENT OF INTERNAL WIRING AND CONNECTED WORKS AT CERTAIN MD ACCN IN DOMESTIC AREA AT AF STN PURNEA UNDER AGE (I) (AF) PURNEA
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No.2 here- in-above but for one 5 pin socket outlet 6 Amps on independent board ,complete all as specified and as directed.

20

-

-

... More
All as per item No.2 here- in- above but for one 5 pin socket outlet 6 Amp on same board with other switches, complete all as specified and as directed.

20

-

-

... More
All as per item No.2 here- in- above but for One bell/buzzer point controlled by one push button same board with other switch or independent board, complete all as specified and as directed.

6

-

-

... More
All as per item No.2 here-in-above but for one 16 Amps socket outlet using by 4.0 sq mm copper conductor cable with 4.0 sq mm PVC insulated single core copper cable for earth continuity conductor, complete all as specified and as directed.

12

-

-

... More
All as per item No.2 here-in-above but for one 16 Amps socket outlet using by 2.5 sq mm copper conductor cable with 2.5 sq mm PVC insulated single core copper cable for earth continuity conductor, complete all as specified and as directed.

20

-

-

... More
Material and labour for point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.

30

-

-

... More
All as per item No.09 here-in-above but for One 3 pin 5 Amps socket out let points on independent board,complete all as specified and directed.

20

-

-

... More
All as per item No.09 here-in-above but for 5 Amp socket on same board with other switches.complete all as specified and directed.

12

-

-

... More
All as per item No.09 above here- in- above but for One bell/buzzer point controlled by one push button same board with other switch or independent board,complete all as specified and directed.

6

-

-

... More
Material and labour point wiring for one socket outlet on independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated Unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes,3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note :- (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.

20

-

-

... More
Supply and fixing sub-main wiring (Concealed type) for main DB's to Sub DB's with PVC insulated & unsheathed two run of 6 Sqmm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLS), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, including taking down existing one complete all as specified and as directed. including taking down old u/s wiring all as specified and directed. Note :- Two runs of 6.0 sq mm cable, one run of PVC conduit and one run of 6 sq mm copper wire shall be measured as one unit length.

40

-

-

... More
All as per item No. 14 here-in-above but for 2 runs of 10.0 sqmm and one run of 10 sqmm copper cable,complete all as specified and as directed.

30

-

-

... More
All as per item No. 14 here-in-above but for 2 runs of 4.0 sqmm and one run of 4.0 sqmm copper cable,complete all as specified and as directed.

40

-

-

... More
All as per item No. 14 here-in-above but for 2 runs of 2.5 sqmm and one run of 2.5 sqmm copper cable,complete all as specified and as directed.

30

-

-

... More
Supply and fixing sub main wiring in PVC casing & caping complete with 2 runs of 6.0 sq mm,single core,PVC insulated,unsheathed cable,1100 volts grade,multi stranded with copper conductor drawn through and including PVC conduit pipe and accessories fixed on surface of wall/floors /concealed etc. with one run of PVC insulated 6 sq mm copper conductor for earth continuity conductor including taking down old US wiring all as specified and directed. Note :- Two runs of 6.0 sqmm cable, one run of casing & caping and one run of 6 sqmm copper wire shall be measured as one unit length.

30

-

-

... More
All as per item No. 18 here-in-above but for 2 runs of 4.0 sqmm and one run of 4.0 sqmm copper cable,complete all as specified and as directed.

25

-

-

... More
All as per item No. 18 here-in-above but for 2 runs of 2.5 sqmm and one run of 2.5 sqmm copper cable,complete all as specified and as directed.

25

-

-

... More
S&F modular switch one way 6 Amps 1 module,complete all as specified and as directed.

80

-

-

... More
S&F Modular socket outlet,5 pin 6 Amps flush 2 module.complete all as specified and as directed.

40

-

-

... More
S&F modular socket outlet combination multipurpose 6A/16A - 2/3 pin combined 2 module flush type universal complete all as specified and as directed.

32

-

-

... More
S&F modular switch one way 16 Amps 1 module complete all as specified and as directed.

32

-

-

... More
S&F modular ceiling fan regulator,electronic type,step type 5 variable speed AC, 230 volts complete all as specified and as directed.

10

-

-

... More
S&F modular bell push flush type 6 Amps,complete all as specified and as directed.

6

-

-

... More
S&F ceiling rose , 3 pin PVC /Polycarboante isolated body, complete all as specified and as dtrected.

60

-

-

... More
S&F call bell ding dong AC 230 volts, single pole, complete all as specified and as directed.

10

-

-

... More
Supply and fixing modular white cover plate with frame ,1 module.complete all as specified and as directed .

4

-

-

... More
Supply and fixing modular white cover plate with frame ,2 module.complete all as specified and as directed .

12

-

-

... More
Supply and fixing modular white cover plate with frame ,3 module.complete all as specified and as directed .

60

-

-

... More
Supply and fixing modular white cover plate with frame ,4 module.complete all as specified and as directed .

15

-

-

... More
Supply and fixing modular white cover plate with frame ,6 module.complete all as specified and as directed .

18

-

-

... More
Supply and fixing modular white cover plate with frame ,8 module.complete all as specified and as directed .

10

-

-

... More
Labour only (Electricians) for attending day to day complain related to bldg. wiring like repair/replacment of switches, light, fan, gyser, MCBs, DBs etc. for all domestic and technical area and rectifying same per day till the period of contract as specified & directed by Engr-in-Charge. i). Contractor has to obtain job card and maintain daily servicability record register and submit the same at the end of week as per APPX 'A' Attached all as directed by Engr-in- Charge. ii).Cost of T&P such as drill and consumables like screw, nails, anchor bolt etc. required deemed to be included in the rate. iii). All other major items will be paid seperately under relevent items. iv). Maximum 4 complains in single Location to be considered one job only. v). Non compliance of complain after 16 working hrs may incur penalty at rate of Rs 500 per day.

100

-

-

... More
Supply only modular switch one way 6 Amps as per existing make,model & type,complete all as specified and as directed.

20

-

-

... More
Supply only Modular socket outlet,5 pin 6 Amps flush type as per existing make,model & type,complete all as specified and as directed.

20

-

-

... More
Supply only modular socket outlet cobination multipurpose 6/16A flush type universal all as per existing make,model & type,complete all as specified and as directed.

10

-

-

... More
Supply only modular switch one way 16 Amps one moduler with indicator all as per existing make,model & type,complete all as specified and as directed.

20

-

-

... More
Supply only modular ceiling fan regulator,electronic type,step type 5 variable speed AC, 230 volts all as per existing make,model & type,complete all as specified and as directed.

20

-

-

... More
Supply only PVC insulated single core FRLS copper Cable 1.5 sqmm,complete all as specified and as directed.

90

-

-

... More
Supply only PVC insulated single core FRLS copper Cable 2.5 sqmm,complete all as specified and as directed.

60

-

-

... More
Supply only switch socket combination 2 in 1 3 pin 6 and 16 Amp flush type with PVC Box universal,complete all as specified and as directed.

30

-

-

... More
Supply only switch socket combination 2 in 1, 6 Amp flush type with PVC Box universal,complete all as specified and as directed.

30

-

-

... More
S&F building secuirity light 25 watt endura citylite platinum new generation energy saving & environmental friendly long life versatile presuure die-cast aluminium IP 65/66 roadway luminaire with high power LED source with acrylic cover.complete all as directed by Engineer-in-Charge.

8

-

-

... More
S&F street light bracket made out of GI pipe light grade 40 mm dia 1.5 mtr long bent to required shape as directed and fixed to pole complete with two coats of aluminium paint over a coat of red oxide primer incl clamps and nut, bolts and washersm, complete all as specified and as directed .

8

-

-

... More
Supply and fix LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed ..

22

-

-

... More
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed by Engineer-in-Charge.

4

-

-

... More
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact,complete all as directed by Engineer-in-Charge.

3

-

-

... More
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 16 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as directed.

2

-

-

... More
Supply and fixed in repairs epoxy powder coated sheet metal enclosure VTPN DB 16 Way double door with Incoming MCCB 250 A, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as directed.

1

-

-

... More
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).

20

-

-

... More
Supply and fixed in repairs MCB SPN 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).

16

-

-

... More
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).

1

-

-

... More
S&F lamp holder, PVC/polycarbonenate type with cord grip cap suitable for batten fittings ,complete all as specified and as directed.

25

-

-

... More
S&F modular switch flush type single pole two way 6 amps complete all as specified and as dtrected.

5

-

-

... More
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as specified and as dtrected. (Note:- spare wherever required to be replaced shall be deemed included in the unit rates of this item).

60

-

-

... More
Dismantling of exhaust / wall mounted/ table fan of any size from its location including disconnecting wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor 2.5 mfd locking nut, screw, split pin, washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing nd making electric connection complete all as specified and directed. (Note:- spare wherever required to be replaced shall be deemed included in the unit rates of this item).

20

-

-

... More
Taking down ceiling fan/exhust fan/wall mounted/pedestal fan any size from its location including disconnecting from ceiling rose, after removing carefully false celing wherever necessary and removing blades, rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat vernishing and refixing the same in original position including greasing of moving parts and replacement of capacitor 2.5 MFD and testing complete all as specified and directed.

30

-

-

... More
S&F in repair plastic ventilation exhaust fan 200/250 mm sweep with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with twin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed. Note:- Cost of cutting and making hole for fixing exhaust fan shall be deemed to included in quoated rates. MAKE:-HAVELLS / USHA / ORIENT / BAJAJ.

5

-

-

... More
S&F in repairs 0.5 sqmm two core copper conductor flexible unsheathed multistranded for electric connection of fan to ceiling rose including necessary connection complete all as specified and directed.

20

-

-

... More
S&F in repair MS clamp made out of 25 mm x 6 mm thick flat iron, including nuts and bolts, washers and "S" hook made out of 25 mm dia MS round bar, complete all as specified and directed.

2

-

-

... More
S&F in repair MS down rod for ceiling fan made out of 20mm dia MS tube 1mm thick wall thickness including drilling holes as required complete all as specified and directed.

2

-

-

... More
Taking down geyser of 50/35/25 ltrs capacity from its position after disconnecting connection , opening of geyser to take out inner tank , soldering at two to three places to stop leakage and also scraping , brushing down old paint with emery paper and apply two coats of white paint using spray machine spray painting and including writing of MES No by black paint, complete all as specified and as directed.

10

-

-

... More
Dismantling of unserviceable air release valve and Supply & fix air release valve suitable for 15mm GI pipe complete all as specified and as directed.

2

-

-

... More
Dismantling of unserviceable vaccum release valve from geyser and Supply & fix new vaccum release valve matching to exist one, complete all as specified and as directed.

4

-

-

... More
Dismantling of existing unserviceable apparatus plate and Supply & fix new copper apparatur plate match to the existing one with rubber gasket suitable for 50 ltrs geyser, complete all as specified and as directed.

2

-

-

... More
All as per item No 67 here-in-above but for 25/35 ltrs capacity.complete all as specified and as directed.

2

-

-

... More
S&F in repair glass wool suitable for geyser, complete all as specified and as directed.

10

-

-

... More
Dismantling of existing unserviceable heating element from geyser and Supply & fix new heating element of 1.5 kw 230 volt at including testing and complete connection all as specified and as directed.

15

-

-

... More
All as per item No 70 here-in-above but of 2.0 kw 230 volt element.complete all as specified and as directed.

8

-

-

... More
Dismantling of existing unserviceable thermostat of geyser and Supply & fix new thermostat matching to exist one including all connection,testing etc. complete all as specified and as directed.

8

-

-

... More
Dismantling of existing unserviceable plug top and Supply & fix 15 amp plug top complete with all connection, complete all as specified and as directed.

10

-

-

... More
Dismantling of exist unserviceable bottom cover of geyser with plate and Supply & fix new bottom cover with plate matching to exist one for 25/50 ltrs capacity, complete all as specified and as directed.

5

-

-

... More
Taking down geyser of 25 ltrs to 35 ltrs capacity from its position after disconnecting of existing water connection for taking out the unserviceable inner tank by opening the geyser and Supply & fix new inner tank and refixing in position after assembling and testing, complete all as specified and as directed.

2

-

-

... More
All as per item No 75 here-in-above but of capacity 50 ltrs.complete all as specified and as directed.

2

-

-

... More
Supply & fix in repair PVC Connection pipe 15 mm dia 60 cm long heavy duty with two Nos brass chromium plated union,complete all as specified and as directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.