Military Engineer Services Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Military Engineer Services - MES Tender

Works
Civil Works Others
Eprocure
Opening Date16 Jan 2025
Closing Date6 Feb 2025
Tender Amount₹ 29,45,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. exc 1.50m but not exceeding 3.00 m deep and getting out in SOFT/LOOSE soil complete, all as specified

0.67

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified.

24

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.

40.59

-

-

... More
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.

57.05

-

-

... More
Hardcore of broken bricks of gauge n exc 63mm, deposited, spred and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete, all as specified.

3.5

-

-

... More
PCC type B-2 (1:2:4), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.

6.5

-

-

... More
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.

0.8

-

-

... More
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.

11.9

-

-

... More
Cement concrete, type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in copings, bands, plinth course, benching and other similar works including use and waste of necessary formwork complete all as specified.

0.07

-

-

... More
Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in cills, steps, seicmic and other similar band, plinth courses, lacing courses , copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angle and throating complete all as specified.

0.3

-

-

... More
Reinforced cement concrete, nominal mix type B-1 (1:2:4) using 20 mm graded stone aggregates in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.

1.3

-

-

... More
Reinforced cement concrete, nominal mix type B-1 (1:2:4) using 20 mm graded stone aggregates as beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified.

0.8

-

-

... More
Reinforced cement concrete,nominal mix type B-1 (1:2:4) using 20 mm graded stone aggregates in columns, pillars, piers, posts and struts complete all as specified.

0.7

-

-

... More
Precast cement concrete type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in louvers and jallies, 25mm thick (measured solid) including all moulding but excluding frame set in cement mortar 1:4 etc complete all as specified

24

-

-

... More
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.

34.7

-

-

... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends, or edges of landings etc. and cutting chases for concealed water tubing, concealed conduit wiring, etc., and making good, cutting exceeding 10 cm girth but not exceeding 20 cm girth, in brick walls, complete all as specified.

36

-

-

... More
Cutting holes into or through brick wall built in cement mortar or cement lime mortar and stone walls built in lime mortar or wall of lime concrete not exc superficial area 150 Sq.cm complete all as specified.

50

-

-

... More
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified.

4

-

-

... More
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified.

5.3

-

-

... More
Use & waste of formwork to edges of concrete flats, treads, breaks in floor, window cill, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and side of RCC/PCC bands in wall, horizontal or sloping and similar work exc 5cm but n exc 10cm wide and making fair finished surface complete all as specified.

23

-

-

... More
Aluminium anodised barrel tower bolt of extruded section 150 mm long, ISI marked, complete all as specified.

3

-

-

... More
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 300 mm long, complete all as specified.

3

-

-

... More
Aluminium (Die cast) door closer hydraulically regulated designation No. 3 aluminium body universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg, ISI marked, complete all as specified.

3

-

-

... More
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks or steel wire staples, all as specified.

18.2

-

-

... More
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified.

100

-

-

... More
Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.

50

-

-

... More
Mild steel TMT bars 6-8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.

146

-

-

... More
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.

74

-

-

... More
Rolled Mild steel works in staging for water tank and the like including caps, bases, splice etc built up from two or more beam or channel sections or angle with plates including all lattice bars, stiffeners, gusset plate etc confirming to Fe-410-Gde E-250, quality- A, complete all as specified.

2315

-

-

... More
5mm thick mild steel plates (plan or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment complete confirming to Fe-410-Gde E-250, quality- A, complete all as specified.

360

-

-

... More
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 22.5cm but not exceeding 30 cm long, dia of neck 5 to 10 mm, complete all as specified.

0.5

-

-

... More
Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.

32

-

-

... More
Powder coated aluminium door shutters fixed type without sash bar including anodised alumnium alumnium glazing snap beading, rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.

8

-

-

... More
Powder coated aluminium window and ventilator shutters fixed type with or without sash bar including anodised alumnium glazing snap beading rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.

10.2

-

-

... More
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including 6 mm dia. GI hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and 40 mm long 12.5 mm dia expansion hold fasteners with and including 12 mm thick gypsum board in ceiling fixed with screw as per manufacturers instruction with level difference in two stages and pattern etc including cutting holes for fixing ceiling light if any complete.

45

-

-

... More
Anodised aluminium snap grid frame work with 20x25mm 'T' and 20x20mm 'L' section with grid size of 605x605mm including with necessary 3.15mm GI wire as in suspended etc complete all as specified.

113

-

-

... More
PVC insulation panels 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of aluminium / GI / MS as per direction of Engg-In-Charge. complete.

113

-

-

... More
100 mm thick Plain Cement Concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as sub base in flooring / hardstanding etc. complete all as specified. NOTE:- The rate included of necessary form work.

25

-

-

... More
100 mm thick Plain Cement Concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as sub base in flooring / hardstanding etc. complete all as specified. NOTE:- The rate included of necessary form work.

10

-

-

... More
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified.

60

-

-

... More
Glass dividing strips 3mm thick and 38mm wide inserted in position confirm to design complete all as specified.

12

-

-

... More
Glazed ceramic coloured tiles 6- 8mm thick (square/ rectangular) area of each tile exc. 0.16 sq.m but n. exc. 0.20 sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry & pointed with polymer based grout of matching shade, laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified.

20

-

-

... More
Coloured vitrified (Light shade) ceramic tiles 9-10mm thick (square/ rectangular) area of each tile n. exc. 0.36 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified.

3

-

-

... More
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.

28

-

-

... More
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), complete all as specified.

75.7

-

-

... More
Three coats of white washing on new undecorated wall surfaces, including preparation of surfaces, complete all as specified.

10

-

-

... More
Two coats of cement base paint on new plastered wall surfaces, including preparation of surfaces, complete all as specified.

42.7

-

-

... More
Two coats of interior acrylic distemper/oil bound distemper on new plastered wall surfaces, including preparation of surfaces with 3mm thick wall care putty, complete all as specified.

20

-

-

... More
Two coats of interior acrylic distemper/oil bound distemper on new prepare / plastered ceiling surfaces, including preparation of surfaces with 3mm thick wall care putty, complete all as specified.

45

-

-

... More
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.

80

-

-

... More
Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.

18

-

-

... More
1000 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP complete all as specified. (v) Nipple 20mm (Minimum weight 20mm-45gms,)

5

-

-

... More
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors,complete all as specified of size: -

-

-

-

... More
15mm bore

40

-

-

... More
20mm bore

120

-

-

... More
Vitreous China wash down water closet pan (One piece) Rimless bowl With cistern For coupled WC With UF Soft Close Slim seat cover, hinges, conversion Bend, Dual Flush cistern fitting, fixing accessories and accessories set, size: 360x7305x740 mm, S Trap- 300 mm (With conversion bend) complete all as specified. MAKE OF EWC: Jaquar Cat No. SLS-WHT-6851S300UF or equivalent make mentioned in Appendix 'B

1

-

-

... More
High density polythene (HDPE) pipes having bore of 15mm of pressure rating 6 kgf/sq.cm complete all as specified.

10

-

-

... More
uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, laid in trenches, under floors or fixed to walls as SWR pipes, complete all as specified.

20

-

-

... More
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, complete all as specified.

4

-

-

... More
Reinforced concrete pipes 450 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.

10.2

-

-

... More
150mm thick (Consisting of each layer 75mm thick compacted thickness) WBM, with (granite, trape or basalt) coarse aggregate of grading 2 (60 to 40mm size) of first layer and grading 3 (50mm to 20mm) of second layer spread rolled and consolidated to gradient and chamber required by using 8 to 10 Tonne power roller complete all as specified.

16.97

-

-

... More
Cement concrete work 250 mm thick in pavement / hard-standing of flexural strength 45 kg / Sq.cm in field using 400 kg of cement per cubic metre including necessary from work and bull nosing, rounding off edges finish by brooming / belting etc. laid in single layer complete all as specified.

33

-

-

... More
Forming contraction joint 30mm deep x10mm wide including provision of 10 mm dia polyurethene foam closed cell backup rod and sealed with sealing compound Grade 'B' complete all as specified.

6

-

-

... More
E/M WORKS

-

-

-

... More
Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal modular boxes made out of 1.2mm thick MS sheet concealed in wall modular metal flush box & including modular cover plate with frame having necessary cutting for fixing switches/ sockets comprising the following: -

-

-

-

... More
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.

31

-

-

... More
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.

4

-

-

... More
One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.

6

-

-

... More
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.

6

-

-

... More
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4).

-

-

-

... More
Switch modular type single pole one way, 6 Amp, complete all as specified.

40

-

-

... More
Switch modular type single pole one way, 16 Amp,complete all as specified.

1

-

-

... More
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified.

10

-

-

... More
Switch socket combination 6 pin 6/16 Amp 3 Module complete all as specified.

6

-

-

... More
Bell/buzzer push, modular type, single pole one way, 6 Amp complete all as specified.

1

-

-

... More
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.

29

-

-

... More
Electric buzzer AC 230 volt, single pole,multi music type complete, all as specified.

1

-

-

... More
Modular box metal body with all necessary fiiting the following no ways: -

-

-

-

... More
One way

2

-

-

... More
Two way

1

-

-

... More
Three way

12

-

-

... More
Four Way

2

-

-

... More
Six way

4

-

-

... More
Eight way

3

-

-

... More
Modular white cover plate & frame with all necessary fiiting the following no ways: -

-

-

-

... More
One way

2

-

-

... More
Two way

1

-

-

... More
Three way

12

-

-

... More
Four Way

2

-

-

... More
Six way

4

-

-

... More
Eight way

3

-

-

... More
Blanking plate to cover switch, MCB, DB's etc complete all as specified..

3

-

-

... More
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.

2

-

-

... More
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -

-

-

-

... More
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable

50

-

-

... More
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable

80

-

-

... More
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"

-

-

-

... More
Rigid non metallic, PVC concealed conduit, not less than 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.

130

-

-

... More
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -

-

-

-

... More
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.

2

-

-

... More
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type and including MCB TPN 40-63 Amp, 10 kA, 'C' curve type

1

-

-

... More
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.

2

-

-

... More
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified.

24

-

-

... More
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40-63 Amp, complete all as specified.

2

-

-

... More
LED lights fitting 1x 20w, 220V,AC decorative box type with driver, including holder suitable for carrying 4ft LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, IN REPLACEMENT, complete all as specified.

6

-

-

... More
LED lights fitting mirror type with high out put diffuser 2 feet, 10 watt 200 V AC decorative box type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, IN REPLACEMENT, complete all as specified.

1

-

-

... More
LED bulb 9 watt with base B-22 (cool day light), 230 V AC, IN REPLACEMENT, complete all as specified.

2

-

-

... More
Decorative wall light fixture with 9 watt LED lamp in a durable plastic body & designer mesh in gold finish including connection with all necessary accessories 230 V AC, IN REPLACEMENT, complete all as specified.

6

-

-

... More
Ceiling interral surface mounting decorative ultra slim liner LED lighting fixture of 12 watt with extruded polycorbonate environmental friendly energy efficient and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, IN REPLACEMENT, complete all as specified. MAKE:- Bajaj Cat part No. BRDCSL12WLEDWH or equivalent make mentioned in Appendix 'B'.

6

-

-

... More
Non-intergral flexible 75 watt LED strip light, IP 65 protection, with high brightness for inddor/outdoor applications, strip can be cut at marked intervals to suit desired length including strip case of required size for casing the strip alongwith all necessary accessories, IN REPLACEMENT, complete all as specified. MAKE:- Bajaj Cat part No. BPLS75WLEDSTRIPIP65AM or equivalent make mentioned in Appendix 'B'.

2

-

-

... More
75 watt LED strip driver for LED 75 watt light , IP 65 protection complete all as specified.

2

-

-

... More
Exhaust fan steel body of size 300mm sweep with louvers, 900 RPM 230 volts single phase AC supply complete with bolt, nuts and washer and including PVC insulated and overall sheathed flexible 3 core 0.5 Sq.mm copper conductor cable from ceiling rose to exhaust fan for giving connection complete all as specified.

1

-

-

... More
Exhaust fan plastic body of size 250mm sweep with louvers, 1200 RPM 230 volts single phase AC supply complete with bolt, nuts and washer and including PVC insulated and overall sheathed flexible 3 core 0.5 Sq.mm copper conductor cable from ceiling rose to exhaust fan for giving connection complete all as specified.

2

-

-

... More
Steel tubes ‘medium grade’, ISI marked, galvanized with all fittings, laid in trenches and connections, complete all as specified, of size as under: -

-

-

-

... More
25mm bore

80

-

-

... More
40mm bore

45

-

-

... More
50 mm bore

80

-

-

... More
Gun metal globe/gate valve, with ron wheel head, ISI marked , screwed both ends for GI tubes, complete all as specified of size: -

-

-

-

... More
25mm bore

4

-

-

... More
40mm bore

3

-

-

... More
50 mm bore

2

-

-

... More
Cutting the existing CI/DI/GI pipes 200mm bore in position for inserting new pipe attachment/ tees or for making new branches etc. with joint & jointing material, without taking down of existing pipe including necessary excavation & earth work complete all as specified

3

-

-

... More
Cutting of road, hard standing made of concrete oe premix carpet, WBM, soling and morrum filling including excavation for laying of cable pipe all as directed and making good the road / hard standing by using all old / new materials and with PCC (1:2:4) etc required to match with the existing surface complete all as specified

12

-

-

... More
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead by means of GI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. (iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt.

2

-

-

... More
PVC insulated, PVC sheathed industrial HV round multicore flexible cable with copper conductor 1.5 Sq.mm 3 core as required for connection of ceiling fan complete all as specified.

35

-

-

... More
Powder coated mild steel down rods suitable for hanging of existing ceiling fan of any sweep complete all as specified.

29

-

-

... More
Taking down carefully existing ceiling fan of any sweep and any make from the site after disconnecting from ceiling rose for carrying out necessary provn work and Re-fixing the same location or other location, complete all as specified.

21

-

-

... More
Demolition and Dismantling work

-

-

-

... More
Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, including stacking at directed location, complete all as specified.

6

-

-

... More
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified

1.5

-

-

... More
Dismantling wall and ceiling boards with snap grid (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified.

45

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified

1.5

-

-

... More
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.

47

-

-

... More
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.

130

-

-

... More
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.

3

-

-

... More
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.