Military Engineer Services Tender
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681638_1Tender No
GE/AF/BHT-40/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Mortice lock, brass body, 4 lever, 100 mm size, vertical type with two keys, complete all as specified.
3
-
-
Factory made WPC box type kitchen cabinet 450 mm deep (externaly) and height required at site fabricated by joining all four sides, middle shelf, backing with solvent cement and gypsum screws and having openble front shutter(s) complete.
12
-
-
Factory made WPC box type kitchen cabinet 600 mm deep (externaly) and height required at site fabricated by joining all four sides, middle shelf, backing with solvent cement and gypsum screws and having openble front shutter(s) complete.
12
-
-
NOTES APPLICABLE TO SERIAL ITEM NO. 5&6: (i) All parts of kitchen cabinet shall be made out of 18 mm thick WPC ply of make mentioned in Appendix 'B'.
(ii) Front Shutter(s) shall be bend at 90°. 5 mm thick PVC ply shall be provided on all internal sides of cabinet to rest the shutter and make it verman/insects proof. Each shutter shall have one 100 mm size stainless steel handle, one magnetic catcher and shall be make operational by providing suitable size stainless steel auto closing hinges openable at 110°. (iii) Front open edges of kitchen cabinet shall be covered with 0.5 mm thick bonding tape of maching shade using adhesive as recommended by manufacturers.
(iv) For measurement purpose elevation area shall be measured. (v) Contractor shall get the kitchen cabinet drawing aproved in writing from the EIC before placing order for fabrication.
(vi) 0.9mm thick lamination over all exposed surface coller & design as approved by GE.
(vii) 2 Nos suitable size channel for drawer.
-
-
-
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks or steel wire staples, all as specified.
3
-
-
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified.
120
-
-
Framed mild steel work as in framed work such as doors, gates or frame for cooler stand with gusset plates, rails, braces etc, drilled for fixing of sheeting or other covering of door etc, to be prepared for hanging or sliding etc including either hooks and hinges or steel hanging door fittings and hanging and fixing similar work conforming to Fe-290 Gde E-165 complete all as specified.
1700
-
-
Mild steel plain black sheet 1.6mm thick as in wall ladding, steel gates and similar work, cut to size , holes, punched including round headed screws clout nails or rivets and fixed to wood or steel framing with plain 40 mm laps joints with riveted or welded seams including bending or turning up, mitred angle etc as required complete all as specified.
26
-
-
4 mm dia galvanised steel wire, 75x50 mm mesh, made up into mattresses or cages, lapped, wired and laid in position etc. Complete all as specified.
40
-
-
Mild steel work plates ( plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment confirming to Fe-410 -Gde E-250, complete all as specified. quality-A complete all as specified
421
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified.
85
-
-
Powder coated aluminium door shutters with aluminum section weighing 0.55 Kg/m, anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges.
(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.
(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
4.2
-
-
Powder coated aluminium window and ventilator shutters side hung type with aluminum section weighing 0.55 Kg/m, anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye.
(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.
(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
4
-
-
Plain tinted sheet glass, 5-6 mm thick, ordinary quality fixed air tight with neoprene packing & almn glazing clips, for aluminium sections, complete all as specified.
2
-
-
Aluminium composite panel sheet 3-4 mm thick, of shade approved by GE, cut to shape and fixed in position as almn door shutter panels/partition, complete all as specified.
6
-
-
Powder coated GI snap grid frame work including suspenders/ level clip with size of grid 605 mm x 605 mm for false ceiling all as specified.
59
-
-
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs / trusses by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.
59
-
-
4 mm thick E board, multipurpose, decorative type, cut to size and fixed in grid frame work ceiling as panels, complete.
59
-
-
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
202
-
-
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified.
150
-
-
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform (including a hole of gas pipe) and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
17
-
-
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
20
-
-
Glazed ceramic coloured tiles not less than 7mm thick, area of each tile exc. 0.13 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified.
274
-
-
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified.
38
-
-
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified.
300
-
-
Coloured vitrified (double charged) ceramic tiles 8-9mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified.
105
-
-
Coloured vitrified (double charged) ceramic tiles 8-9mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc .0.38 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified.
9
-
-
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
120
-
-
Plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
8
-
-
Figured glass 4mm thick ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
1
-
-
Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -
(a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
145
-
-
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -
(a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
120
-
-
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.
85
-
-
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking up or down steel tubing and connections from existing location, complete all as specified of size: -
-
-
-
15mm bore
80
-
-
20mm bore
40
-
-
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No.6510 or equivalent make mentioned in Appndix 'B'.
37
-
-
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. 6518 or equivalent make mentioned in Appndix 'B'.
8
-
-
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No.6509 or equivalent make mentioned in Appndix 'B'.
49
-
-
Pillar cock, swan neck type, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete.
MAKE: PRAYAG Cat No. 6514 or equivalent make mentioned in Appndix 'B'
9
-
-
Brass towel rail 600 mm long, glossy finish, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete.
MAKE: PRAYAG Cat No. CPA-1 or equivalent make mentioned in Appndix 'B'.
9
-
-
150 mm size overhead ABS shower with cast copper alloy chromium plated arm 225 mm long with flange and fixed in position, IN REPAIRS, complete.
MAKE: PRAYAG Cat No. CPOH-4 or equivalent make mentioned in Appndix 'B'.
8
-
-
Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs,complete.
MAKE: PRAYAG Cat No. CPA-48 or equivalent make mentioned in Appendix 'B'.
8
-
-
Glass shelf 500x125 mm with brass brackets and fixed to wall with chromium plated brass screws and rawl plugs, complete. MAKE: PRAYAG Cat No. CPA-31 or equivalent make mentioned in Appendix 'B'.
16
-
-
Vitreous China squatting pan 'orissa' pattern, size 580 X440mm white, integral foot rests, including 'P' or 'S' trap and saintary connection socket to fit WC outlet including connection to trap , to flusing pipe, anti syphonage pipe etc complete including making good to floor, IN REPLACEMENT, complete all as specified.
8
-
-
Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including stainless steel body Jet spray (L-bend) with 1.50 metre long braded tube tube, soft close ISI marked PVC seat & cover and uPVC 'S trap, IN REPLACEMENT,, complete all as specified
1
-
-
Vitreous China half stall Urinal pot, white, size 345 x 320 x 560 mm, with & including cast copper alloy, half or full threaded chromium plated waste coupling suitable for & including 32 mm size PVC waste/discharge pipe, rag bolts, IN REPAIRS, complete.
3
-
-
Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPAIRS, complete all as specified.
9
-
-
PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, IN REPLACEMENT, complete.
9
-
-
Health faucet with 1 metre SS tube & wall hook including making connection complete. MAKE : PRAYAG Cat No. CPHF-9 or equivalent make mentioned in Appendix 'B'.
1
-
-
Flush cock (lever type) 25 mm size for urinals complete. MAKE : PRAYAG Cat No. CPA-34 or equivalent make mentioned in Appendix 'B'.
3
-
-
Looking mirror 600 x 600 mm, selected quality glass 5.5 mm thick, mounted on PVC ply not less than 4 mm thick, and provision of PVC frame alround fixed with chromium plated brass screws and rawl plugs, IN REPAIRS, complete.
9
-
-
PVC connections with PTMT nuts, 450 mm long, IN REPAIRS, complete all as specified.
37
-
-
Stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 940mm x 460mm x 203mm with bowl size 405mm x 354mm x 203mm IN REPLACEMENT complete all as specified
MAKE: PRAYAG Cat No. PSS-5 or equivalent make mentioned in Appndix 'B'.
8
-
-
Stainless Steel kitchen plate rack of sheet thickness not less than 0.61 mm overall size 786 x 914 x 254 mm, fixed on walls wth PVC plugs and SS screws, IN REPAIRS, complete.
MAKE: PRAYAG Cat No. PSP-6 or equivalent make mentioned in Appndix 'B'.
8
-
-
uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified.
45
-
-
uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified.
45
-
-
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, IN REPAIRS, complete all as specified.
18
-
-
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, IN REPAIRS, complete all as specified.
18
-
-
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified,
26
-
-
uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified.
8
-
-
E/M WORKS
-
-
-
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame & cover plate suitable (for fixing modular switch/sockets) comprising the following: -
-
-
-
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
222
-
-
One Socket outlet, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
48
-
-
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
48
-
-
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
48
-
-
NOTES FOR SERIAL ITEM NOS 63: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed.
(c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
(d) Cutting chase to wall wherever required including in the rates.
-
-
-
Bell push switch modular type single pole one way, 6 Amp, complete all as specified.
12
-
-
Switch modular type single pole one way, 6 Amp, 1 Module, complete all as specified.
306
-
-
Switch modular type single pole one way, 16 Amp, 1 Module, complete all as specified.
48
-
-
Socket outlet modular type multipurpose having provision for 2&3 pin, 6 Amp, complete all as specified.
96
-
-
Socket outlet modular type multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, complete all as specified.
48
-
-
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
150
-
-
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
40
-
-
Electric buzzer AC 230 volt, single pole, Ding Dong type complete, all as specified.
12
-
-
Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified.
32
-
-
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
-
-
-
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
224
-
-
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
495
-
-
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
-
-
-
Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
719
-
-
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
72
-
-
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40-63 Amp complete all as specified.
12
-
-
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
-
-
-
SPN, 8 way with 100 Amp rated bus bar, 240 V, double door type.
12
-
-
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type.
6
-
-
Environment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser for glarefree light, 6000K, including making connections, complete.
MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
20
-
-
Surface mounted environment friendly with eye soft technology & glarefree diffuser LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete.
MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
66
-
-
Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
16
-
-
Wall mounted environment friendly with eye soft technology & glarefree diffuser LED 10 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete.
MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCSS or equivalent in makes mentioned in Appendix 'B' here-in-after.
28
-
-
LED 9/10 W bulb and connecting up from ceiling rose complete.
40
-
-
Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified. MAKE: Havells Cat No. FHEHDSPDB120 or equivalent in makes mentioned in Appendix 'B' here-in-after.
18
-
-
Ceiling fan 1200 mm sweep, 230 V with blades & down rod, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated, brushless direct current motor (BLDC) and connecting up from ceiling rose or connector to fan, complete all as specified.
MAKE: Havells Cat No. FHCEK5SWHT48 or equivalent in makes mentioned in Appendix 'B' here-in-after.
32
-
-
Electric water heater storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 litre, BEE 5 star rating complete with all accessories such as safety valve, thermostate, NRV, steel PVC connector for hot water etc complete all as specified. MAKE: Havells Cat No. GHWAFATWB025 or equivalent in makes mentioned in Appendix 'B' here-in-after.
10
-
-
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead by means of GI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I.
Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt.
14
-
-
DISMANTLING/DEMOLITION WORKS
-
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified.
4
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified.
2
-
-
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
353
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified.
168
-
-
Dismantling stone slab and tiles of any description or thickness in floor,apron bedded and pointed in any mortar etc complete all as specified.
1.68
-
-
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.d
4.5
-
-
Dismantling structural steel works or of any description / type including doors, gates etc complete all as specified.
20
-
-
Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified.
59
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
77
-
-
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
366
-
-
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
719
-
-
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.
18
-
-
Taking down carefully light fitting of any description, complete all as specified.
170
-
-
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
-
-
-