Military Engineer Services Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date6 May 2024
Closing Date1 Jun 2024
Tender Amount₹ 47,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing of excavated material (soil) to a distance n.exc 50 meter and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified and as directed.

405

-

-

... More
Supply and laying new dry river sand laid in trenches 8 cm below the underground cable and 15cm above the cable and punned to 18 cm as cable cushioning and covering complete all as specified and as directed.

279.45

-

-

... More
Supply and laying brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable complete all as specified and directed by Engr-in-Charge.

16

-

-

... More
Relaying of bricks/PCC cover after cleaning, obtained from taking down of UG cable for protection of UG cable all as specified and directed by Engr-in-Charge.

8600

-

-

... More
Taking up old unserviceable LT cable of any size & type from the trenches or pipe including taking out brick/PCC cable protection and set-aside for reuse as directed by the Engr-in-Charge.

3550

-

-

... More
Supply and laying in trenches, fix on pole or passing through pipe and testing & commissioning of LT XLPE insulated, heavy duty PVC electric cable with aluminium conductor, 1100 volts grade, including aluminium cable lugs, gland etc of suitable size complete all as specified and as directed for following size of cable:- (a) Cross sectional area 150 Sqmm 3.5 core

400

-

-

... More
(b) Cross sectional area 120 Sqmm 3.5 core

800

-

-

... More
(c) Cross sectional area 50 Sqmm 3.5 core

700

-

-

... More
(d) Cross sectional area 35 Sqmm 3.5 core

650

-

-

... More
(e) Cross sectional area 16 Sqmm 4 core

450

-

-

... More
(f) Cross sectional area 10 Sqmm 2 core

550

-

-

... More
Supply and laying in replacement of GI pipe 80mm bore, light grade for cable protection complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply and laying in replacement of GI pipe 50mm bore, light grade for cable protection complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
M&L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note:- (i) Making good the disturbes surface & removal of surplus soil shall be deemed to be included in the unit rate. (ii) GI pipe will be measured and paid separately under relevant item of Schedule ‘A’.

68

-

-

... More
Supply and fixing LT Bus bar chamber Outdoor/wall mounted suitable for 415 V 3 phase 4 wire 50 Hz AC supply system busbar capacity 200A. The chamber should be powder coated paint for better environmental protection, made of CRCA sheet steel 3.15 mm, CPRI approved, lugs and glang of suitable size, fixing and connection etc. including provn of foundation of the panel. The foundation/platform should be 0.15m projection all around & 0.60m height above ground level and 0.30 m below ground level made with PCC Blocks in cm 1:6 including excavation and earth work. 75mm thick PCC(1:4:8) type D2 sub base over approved/rammed earth, PCC 1:2:4 type B1 with 20mm graded aggregate 10cm thick coping at top of the platform, plastering with 20mm thick in cm 1:4 on all around including top of platform and applying three coats of white wash etc complete including necessary form work all as directed by engineer-in-charge

4

-

-

... More
Supply and fixing LT Bus bar chamber Outdoor/wall mounted suitable for 415 V 3 phase 4 wire 50 Hz AC supply system busbar capacity 400A. The chamber should be powder coated paint for better environmental protection, made of CRCA sheet steel 3.15 mm, CPRI approved, lugs and glang of suitable size, fixing and connection etc. including provn of foundation of the panel. The foundation/platform should be 0.15m projection all around & 0.60m height above ground level and 0.30 m below ground level made with PCC Blocks in cm 1:6 including excavation and earth work. 75mm thick PCC(1:4:8) type D2 sub base over approved/rammed earth, PCC 1:2:4 type B1 with 20mm graded aggregate 10cm thick coping at top of the platform, plastering with 20mm thick in cm 1:4 on all around including top of platform and applying three coats of white wash etc complete including necessary form work all as directed by engineer-in-charge

3

-

-

... More
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Feeder Pillar board outdoor type of suitable size made out of MS sheet 3.15mm thick, Type tested conforming to IEC 61439, powder coated, rear and front operated door with locking arrangement, suitable aluminium busbar and fixed on 50x50x5 mm angle iron base suitable for pedestal mounting at least 0.60m above GL to accommodating & including the following complete all as directed.:- INCOMING :- (A) MCCB 250 Amps, 4 pole, 36 KA - 01 (incoming) OUTGOING :- (B) MCCB 160 Amps 4 pole, 25 KA - 01 Nos (outgoing) (C) MCCB 125 Amps 4 pole, 25 KA - 01 Nos (outgoing) (D) MCCB 100 Amps 4 pole, 25 KA - 01 Nos (outgoing) (E) MCCB 63 Amps 4 pole, 25 KA - 02 Nos (outgoing) (F) MCB 32 Amps, DP, 15 KA - 02 Nos (outgoing) (G) MCCB 16 Amps, DP, 15 KA - 01 Nos (outgoing) (H) Digital Multi-functional Meters for measuring current, voltage and frequency including CTs of suitable rating and class.

1

-

-

... More
M&L PCC 1:2:4 type B 1 (using 20mm graded stone aggregate) as in benching / copping around base of LT feeder pillar etc. including necessary form work complete all as directed.

2

-

-

... More
M&L for disconnecting the electric connection and dismantling of the existing old rusted LT panel board of any size depositing to MES store yard or otherwise including it's accessories complete all as directed by Engineer-in-Charge.

3

-

-

... More
Supply, installation, testing and commissioning of feeder pillar cubicle type suitable size weather proof outdoor type, CPRI approved, IP:55 protection, totally type tested, both side openable, factory made having canopy, dust and vermin proof fabricated from CRCA sheet 3.15mm thick including powder coated paint and suitable for 415 volt 3 phase 50 c/s mounted on pedestal/platform. The panel should mounting with & including following accessories with working space and wiring with copper wire of suitable size complete as required and as directed:- (a) Basic Automatic Transfer controller unit with integrated dual power supply suitable for 630 Amp rating motorised changeover - 01 (b) Motorised Changeover 630 Amps Rating, 4 pole -01 (c) MCCB 400 Amps, 4 pole 50 KA with LSIG Protection - 01 Nos (Incoming) (d) MCCB 320 Amps, 4 pole 36 KA with thermal magnetic release - 02 Nos (outgoing) (e) MCCB 200 Amps, 4 pole 36 KA with thermal magnetic release - 03 Nos (outgoing) (f) MCCB 125 Amps, 4 pole 36 KA with thermal magnetic release - 02 Nos (outgoing) (g) MCCB 100 Amps, 4 pole 36 KA with thermal magnetic release - 03 Nos (outgoing) PLATFORM: Platform for feeder pillar should be 0.15m projection all around & 0.50m height above ground level and 0.30 m below ground level with PCC Blocks built in cement mortar 1:6 including excavation and earth work. 75mm thick PCC(1:4:8) type D2 sub base over approved/rammed earth, PCC 1:2:4 type B1 with 20mm graded aggregate 10cm thick coping at top of the platform, plastering 20mm thick in cm 1:4 on all around including top of platform and applying three coats of white wash etc complete including necessary form work all as directed by engineer-in-charge

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.