Military Engineer Services Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 May 2023
Closing Date26 Jun 2023
Tender Amount₹ 12,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 1 above but DG set of cap 62.5 KVA make Kirloskar installed at pump house No 3, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at pump house No 2, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 40 KVA Make Sonilika installed at Tropo perimeter SS No 2, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at ATC sub station (Alt), complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 40 KVA Make Sonilika installed at OTES, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at ATC S/S, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 25 KVA Make Cummins Jakson Installed at Main Guard room, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 25 KVA Make Cummins Jakson Installed at Sub Guard room, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 15 KVA Make Cummins Jakson Installed at Sub stn No 2 (Tropo), complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
All as per item No 1 above but DG set of cap 15 KVA Make Cummins Jakson Installed at 10 ASC, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Inspection, maintenance and servicing of DG set 75 KVA installed at AF Net site 1 including Alternator, excluding AMF panels connected to DG sets for routine check up of the engine for the smooth functioning and carrying out the complete B -check as per Manufacturer's instructions including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc, all as specified and directed by Engr-in-Charge. Note for item No. 13 to 24: Engine oil & Coolant oil will be measured and paid separately.

3

-

-

... More
All as per item No 13 above but DG set of cap 75 KVA installed at AF Net Site 2, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 62.5 KVA installed at pump house No 3, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 40 KVA installed at Pump House No 2, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 40 KVA installed at Tropo perimeter SS No 2, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 40 KVA installed at ATC sub station (Alt), complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 40 KVA installed at OTES, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 40 KVA installed at ATC S/S, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 25 KVA Installed at Main Guard room, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 25 KVA Installed at Sub Guard room, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 15 KVA Installed at Sub stn No 2 (Tropo), complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 13 above but DG set of cap 15 KVA Installed at 10 ASC, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply only engine oil SAE 20W-40W, complete all as specified and directed. (Make - Valvoline, Servo, Shell, Castrol)

250

-

-

... More
Supply only radiator coolant, complete all as specified and directed. (Make - Valvoline, Servo, Shell, Castrol)

60

-

-

... More
Servicing & Maintenance of AMF panels pertains to 75 KVA DG SET installed at AF Net site 1 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts, cleaning & servicing all contact points etc complete all as specified and directed by Engr-in-Charge. Note: Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

3

-

-

... More
All as per item No 27 above but DG set of cap 75 KVA installed at AF Net Site 2, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 62.5 KVA installed at pump house No 3, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No. 27 above but DG set of cap 40 KVA installed at Pump House No. 2, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 40 KVA installed at Tropo perimeter SS No 2, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 40 KVA installed at ATC sub station (Alt), complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 40 KVA installed at OTES, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 40 KVA installed at ATC S/S, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 25 KVA Installed at Main Guard room, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 25 KVA Installed at Sub Guard room, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 15 KVA Installed at Sub stn No 2 (Tropo), complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item No 27 above but DG set of cap 15 KVA Installed at 10 ASC, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Removing the self starter 12 Volt DC from the engine of 15 to 75 KVA DG sets and taking to work shop for rewinding of armature/field including replacement of brush and bush and refixing the same to the engine and testing, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply only 12 V DC stopping solenoid suitable for 15 to 75 KVA DG sets, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only Water Temp gauge with adapter, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only oil temp gauge with adapter, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only Oil pressure guage with pipe, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only AC / DC Timer, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only PLA Relay with Base, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only Volt meter DC, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only Ammeter DC, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply and fixing maintenance free Battery 12 Volts 80AH, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply and fixing maintenance free Battery 12 Volts 100AH, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply only Selector switch 3 way 4 pole, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Supply only Volt meter selector switch, complete all as specified and directed by Engr-in-Charge. (Spares for executing the Sl item Nos. 27 to 38)

4

-

-

... More
Taking out unserviceable power contactor and Supply and fixing power contactor suitable for AMF panel up 40 to 75 KVA, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 62.5 to 75 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 40 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 15 to 25 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
S & F dynamo fan belt set suitable for DG Set 62.5 to 75 KVA, complete all as specified and directed by Engr-in-Charge. Make : Kirloskar

6

-

-

... More
S & F dynamo fan belt set suitable for for DG Set 15 to 40 KVA, complete all as specified and directed by Engr-in-Charge. Make : Kirloskar

6

-

-

... More
S & F water pump suitable for 62.5 to 75 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S & F water pump suitable for 40 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F water hose pipe set with clamps suitable for 62.5 - 75 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S & F water hose pipe set with clamps suitable for 40 KVA DG Set, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
S&F Relay suitable for Kirloskar Make DG Set 62.5-75 KVA (existing type & voltage -24/12 Volts) in AMF panel and making connections including testing, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
S & F Relay suitable for Kirloskar Make DG Set 40 KVA (existing type & voltage - 240 Volts AC) in AMF panel and making connections including testing, complete all as specified and directed by Engr-in-Charge. Make: L&T, Siemens, Legrand, Havells

4

-

-

... More
S & F Auxiliary contact suitable for Kirloskar Make DG Set 62.5-75 KVA (Existing type) with logic units, complete all as specified and directed by Engr-in-Charge. Make: L&T/Legrand/ Havells/Siemens

4

-

-

... More
S & F Main contactor four pole, 220 Volt suitable for 75 KVA DG set of existing model, complete all as specified and directed by Engr-in-Charge. Make- L&T, Havells, Legrand, Siemens

2

-

-

... More
S & F SMPS unit suitable for DG Set 62.5 - 75 KVA DG Set for battery charging including making connections and testing etc, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F in replacement of unsv MCB DB 220 volts 12 way double door, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Material, Labour and checking for fire alarm system incl rectification of loop, smoke detector, hooter, mother board and MCP and if necessary armoured wire of 1.5 sqmm 2 core need to be supplied, complete all as specified and directed by Engr-in-Charge.

7

-

-

... More
Supply and fixing of ON load change over switch having current rating 200 Amps, 415 volts, 50 Hz, 4 pole with steel sheet encls conforming to IS :13947 (part-3), IEC : 60947-3, complete all as specified and directed.

3

-

-

... More
Dismantling of upper portion of Diesel Engine 75 KVA ,Water cooled, Turbo charged 1500 RPM vertical type installed at AF stn Bihta and Top over hauling and repair / servicing of engine including taking out radiator, fuel pump, hydraulic governors, lube oil pumps, water pump, turbo charger etc, assembling of engine after replacement of UNSV defective parts, complete all as specified and directed. Note:- Cost of defective parts shall be deemed included in quoted rate.

2

-

-

... More
M & L for grinding, cutting of cylinder heads including inserting of new valves (Exhaust and inlet) valve shafts guide, called valve spring etc, complete all as specified and directed. Note:-Cost of Spares as required included in quoted rate.

5

-

-

... More
Repair and overhauling and calibration of fuel pump complete with replacement of worn out parts such as bearings, plunger, impellar and oil seal etc including calibration of injector and refixing fuel injector pump and injector including testing, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and fix on wall 'DO AND DON'T chart for electric installation and made out of plastic based paper with glass cover and aluminium frame of size 0.80 mtrsx1.00 mtrs including two numbers clamp for hanging arrangements with instructions written in language in Hindi or English, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Supply and fixing automatic voltage regulator (AVR) for DG set of capacity 62.50 to 75 KVA, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing automatic voltage regulator (AVR) for DG set of capacity upto 40 KVA, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing AMF panel of capacity upto 40 KVA DG set, complete all as specified and directed by Engr -in-Charge.

2

-

-

... More
M&L for complete dismantling and servicing of existing unsv solar water heater and collector panel of capacity 100 LPD of any Make with electric back up system after disconnecting the existing water supply/water connection from any height of the building/ ground, including stripping out the hot water vessel by taking out, outer cover, insulating materials etc and continuous brazing /welding of the inner container where required for arresting leakages including replacemnt of defective/worn out spare parts etc and re-assembling the system connecting the water/ electrial connections complete and testing upto the satisfaction of Engr-in-Charge, complete all as specified and directed.

2

-

-

... More
~ditto~ all as per Ser item No 76 above but for solar water heater of capacity 200/300 LPD, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Repair and maintenance of EOT crane 0.5 / 2.5 Ton installed at Radar by checking all mechnical and electrical equipment/system for normal working and testing with the load if provided by user including greasing, oiling and replacing minor spares and consumbles, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Supply and fix breaker motor coil for the EOT crane 0.5 to 2.5 Ton, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing of conventional fire alarm panel of 16 zones which consists of display board and provn of autodials as approved by the GE, complete all as specified and directed by Engr-in-charge.

4

-

-

... More
Supply and fixing of battery 12V 08 AH for fire alarm panel of 16 zones, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Supply and fixing LED luminaries (120 Lumen/watt) 600 mm x 600 mm, 30 watt (LCTLRNE-30-FO-CDL) suitable for 230 volts, 50 HZ AC supply recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size from ceiling rose incl taking down old one, complete all as specified and directed by Engr-in-charge.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.