Military Engineer Services Tender
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Costs
EMD
₹ 19,980Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677375_1Bid Award Id
ViewTender No
GE/AF/BHT-38/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Clean dry sand (locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete, all as specified.
NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
18
-
-
Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
2600
-
-
GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc including taking down existing pipe, complete all as specified of following size: -
-
-
-
50mm bore
12
-
-
80mm bore
12
-
-
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including taking down existing cable, complete all as specified of sectional area: -
-
-
-
35 Sq.mm, 3.5 core
200
-
-
70 Sq.mm, 3.5 core
105
-
-
95 Sq.mm,3.5 core
100
-
-
120 Sq.mm,3.5 core
120
-
-
NOTE: Excavation and earth work, sand cushioning, protection cover & GI pipe shall be measured and paid for separately.
-
-
-
Cable joining kit (Indoor/Outdoor Heat Shrinkable type) for 1100 V (Earthed) grade cable complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable including taking down unserviceable termination complete, all as specified of following sizes: -
-
-
-
25-50 Sq. mm, 3.5 core
2
-
-
70-120 Sq. mm, 3.5 core
4
-
-
185-300 Sq. mm, 3.5 core
2
-
-
Cable joining kit (straight through heat shrinkable) for 1100 V (Earthed) grade cable complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable including taking down unserviceable termination complete, all as specified of following sizes: -
-
-
-
25-50 Sq. mm, 3.5 core
2
-
-
70-120 Sq. mm, 3.5 core
4
-
-
185-300 Sq. mm, 3.5 core
2
-
-
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32x6 mm as earthing lead by means of GI or steel bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I.
Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt.
2
-
-
MCCB with adjustable thermal magnetic release, ICS=ICU=100%, 4 Pole, 415 volts, AC, with over load and short circuit protection and rupturing capacity complete all as specified of following size, IN REPLACEMENT: -
-
-
-
100 Amp, rupturing capacity 16 kA.
2
-
-
160 Amp, rupturing capacity 36 kA.
1
-
-
250 Amp, rupturing capacity 36 kA.
1
-
-
400 Amp, rupturing capacity 36 kA.
1
-
-
630 Amp, rupturing capacity 50 kA.
1
-
-
Disconnecting & taking down water storage geyser for repair etc. from existing location and refixing & reconnecting the same on orginal or new location after repair complete, of the following capacities:-
-
-
-
25 litre
70
-
-
50 litre
15
-
-
NOTE: Repair / Replacement of unserviceable spare parts/ items and painiting as specified will be measured & paid for under serial item No. 14.00 to 14.20 here-in-below as required & where directed.
-
-
-
Dismantling/ taking out of inner storage hot water tank , geyser assembly, heating element , glass wool etc from in side the geyser of capacity 25/50 litre and including remove blockage / depositing the scale, silt, sludge, dirty particles material from the inside of the storage heating system through method of descaling with chemical acid or manually mechanically system and after washing in side of the storage heating tank, geyser assembly, heating element, thermostat system including tighting, adjustment, servicing and also rectification the leakage problem of hot tank through hot & cold welding / brazing (gas or electric welding) work system for steel tank / copper tank complete and after repair re-assembly and proper filling the glass wool and replacement of defected items in side around the tank complete.
NOTE: Repair / Replacement of unserviceable spare parts/ items and painting will be measured & paid for under serial item No. 14.00 to 14.20 here-in-below as required & where directed.
60
-
-
Replacement of the unserviceable articles/parts of water storage geyser as required & where directed as under: -
-
-
-
Heating element of copper / brass alloy round , triangular, round with threaded type shape / alongwith 'O' ring washer as per existing size sample / model for rating 1.5 kW complete.
88
-
-
Heating element of copper / brass alloy round , triangular, round with threaded type shape / alongwith 'O' ring washer as per existing size sample / model for rating 2 kW complete.
30
-
-
Inner cold and hot water circulating apparatus unit assembly (Geysers assembly) alongwith replacement of defected nuts and bolts and rubber check washer, split gas pin system complete, for geyser capacity 25 Litre
9
-
-
Inner cold and hot water circulating apparatus unit assembly (Geysers assembly) alongwith replacement of defected nuts and bolts and rubber check washer, split gas pin system complete, for geyser capacity 50 Litre
9
-
-
Gun metal vertical type non return valve of size 15 mm bore complete.
15
-
-
Hot water inner tank made out of heavy duty stainless steel sheet metal body system alongwith nuts and bolts and rubber joint washers for storatge type geyser capacity 25 Litre complete.
15
-
-
Hot water inner tank made out of heavy duty stainless steel sheet metal body system alongwith nuts and bolts and rubber joint washers for storage type geyser capacity 50 Litre complete.
15
-
-
Adjustable setting type thermostat made out of copper / brass alloy metal for storage type geyser capacity 25 Litre complete
16
-
-
Adjustable setting type thermostat made out of copper / brass alloy metal for storage type geyser capacity 50 Litre complete
55
-
-
Capilary setting type thermostat made out of copper / brass alloy metal for storage type geyser capacity 25 Litre complete
30
-
-
Air safety valve for storage geyser of capacity 25 ltr to 50 Litre complete
15
-
-
Insulating material i.e. glass wool for filling inside area in between of geyser outer body and hot water tank system including dismantling of geyser for capacity 25 to 35 Litre complete
15
-
-
Insulating material i.e. glass wool for filling inside area in between of geyser outer body and hot water tank system including dismantling of geyser for capacity 50 Litre complete
15
-
-
Mild steel outer cover top plate duly spray painted with super enamel paint over a coat of red oxide primer complete for 25 to 35 Litre capacity storage geyser.
5
-
-
Mild steel outer cover top plate duly spray painted with super enamel paint over a coat of red oxide primer complete for 50 Litre capacity storage geyser.
3
-
-
Mild steel outer bottom cover plate duly spray painted with super enamel paint over a coat of red oxide primer complete for 25 Litre capacity storage geyser.
5
-
-
Mild steel outer bottom cover plate duly spray painted with super enamel paint over a coat of red oxide primer complete for 50 Litre capacity storage geyser.
5
-
-
Mild steel outer body cover duly spray painted with super enamel paint over a coat of red oxide primer complete for 25 Litre capacity storage geyser.
5
-
-
Mild steel outer body cover duly spray painted with super enamel paint over a coat of red oxide primer complete for 50 Litre capacity storage geyser.
5
-
-
Indicating lamp Red /Green round & square shape display for geyser on / off indicating system complete all as specified.
30
-
-
NOTE FOR SERIAL ITEM 14.01 TO 14.20: The size/make/ model/nomenclature above mentioned new items shall be as per existing item or as directed by Engineer-in-Charge.
-
-
-
Spray painting to external body of storage geyser of capacity 25/50 litre including clamps with first quality synthetic enamel paint of white shade, at site or in store including filling cavities with filler materials and preparation of steel surfaces including marking MES No. with black paint on each geyser complete.
5
-
-
Heavy duty PVC braided PVC connection pipe of size 15 mm dia and 450 mm long alongwith two nos of brass nut and nylon washer IN REPLACEMENT complete all as specified.
30
-
-
Heavy duty steel wire braided chromium plated stainless steel metal body connection pipe of size 15 mm bore and 600 mm long alongwith two nos of brass nut and nylon washer IN REPLACEMENT complete all as specified.
25
-
-
Angle valve suitable for 15 mm bore made out of cast copper alloy chromium plated iron pipe connection, IN REPLACEMENT, complete all as specified.
8
-
-
Flexible type PVC bedded copper cable of size 2.5 sq.mm 3 core (40/00.0076 type size) 1100 volt grade cable with PVC insulated PVC sheathed with multi stranded copper conductor IN REPLACEMENT, complete all as specified
90
-
-
MS sheet metal enclosure assembly with having SPN enclosure and 2/3 pin top plug & earth socket of rating voltage 220 volt AC IN REPLACEMENT, complete all as specified.
5
-
-
Heavy duty MS fasteners of suitable of size 10 mm dia not exceeding up to 100 mm long along with nut, bolt & washer etc including drilling holes grouting on wall for hanging geyser. and making good the disturbed surfaces to the entire satisfaction of Engineer in Charge, IN REPLACEMENT complete.
36
-
-
Sub main wiring system with having two run of PVC insulated wire of size 2.5 sq.mm FRLSH multistrand copper conductor cable 1100 volts grade drawn into including providing one run of 2.5 Sq.mm FRLSH multistrand copper conductor cable as continuous earth wire for connecting to common earth including taking down existing wiring all as specified.
90
-
-
Sub main wiring system with having two run of PVC insulated wire of size 4 sq.mm FRLSH multistrand copper conductor cable 1100 volts grade drawn into including providing one run of 4 Sq.mm FRLSH multistrand copper conductor cable as continuous earth wire for connecting to common earth including taking down existing wiring all as specified
90
-
-
Rigid non metallic heavy duty PVC conduit medium grade not less than 20 mm dia ISI marked alongwith all conduit fittings and fixing accessories duly fixed on wall / surface / roof mounting system with the help of saddle with base clamps IN REPLACEMENT complete all as specified.
180
-
-
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp and making electrical connection, IN REPLACEMENT complete all as specified. .
25
-
-
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40 Amp and making electrical connection, IN REPLACEMENT complete all as specified.
25
-
-
PVC insulated body three pin plug top of rating capacity 15/16 Amp and making electrical connection IN REPLACEMENT complete all as specified.
20
-
-
Switch piano flush button single pole one way 16 Amp, 240 volts IN REPLACEMENT complete all as specified.
20
-
-
Cutting and trimming trees branch any girth and any size touching to overhead lines and cleaning the distance 2.0 mtrs length both sids of OH line with a span of 50 mtrs (approx) each disposing the same clearing the site upto the satisfaction level and all as directed by Engr-in-charge.
Note : All tools, plants and machinary equipment and manning required are quoted in the rates.
28
-
-
Cutting anxious green growth/ vegetation growth for cleaning out the area around transformer/ installations and four pole structure yards at ground level by cutting out roots, unwanted plant bushes and removal of the same by surface excavation not exceeding 15 cm deep complete.
350
-
-
Note : Amount of credit for retrieved materials is mentioned in Sch 'A' of tender documents in pdf form which will be deducted while acceptance of tender offline.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements