Indian Oil Corporation Limited Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Indian Oil Corporation Limited - IOCL Tender

Works
Civil And Construction
Building Construction
Consultancy Services
Eprocure
Opening Date17 Apr 2025
Closing Date25 Apr 2025
Tender Amount₹ 98,67,164 
Notes
Download

Costs

Summary

Development Of B Site Ro Location - Within 2 Km From Nahar Chowk, Raukanpura Towards Digha(on Rukanpura -digha Road) Distt- Patnastate Bihar Under Patna Divisional Office Under Bihar State Office

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
i) Local Fine Sand within grading zone IV

50

1355

67758

... More
iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)

5

6059

30297.95

... More
ix) 1:4:8(1 Cement :4 Fine Sand : 8 Graded stone aggregate of 40mm)

5

4915

24576.25

... More
v) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20mm

15

7163

107448

... More
i) Foundations,footings,bases of column

30

254

7627.799999999999

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

8

6889

55115.2

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

10

254

2542.6

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

800

74

59632.00000000001

... More
ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH

10

5496

54962.200000000004

... More
Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks

150

607

91161

... More
iii) Granite of any colour and shade having Area of slab upto 0.50 sqm

32

3764

120462.4

... More
Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:

1650

90

149853

... More
i) Hot finished welded type tubes

1950

128

249677.99999999997

... More
ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

100

226

22695

... More
Providing Neat cement punning

100

56

5602

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution

30

123

3695.4

... More
vii) 40mm dia HDPE pipe for borewell upto a depth of 65m

500

118

59090

... More
Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.

250

2973

743377.5

... More
Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.

75

4134

310077.75

... More
i) 225 mm Height

98

2478

242907.7

... More
Providing contraction joints of 10 mm wide and 25mm deep groove cutting and filled with polysulphide sealant and primer of all complete and as per drawing, specification and direction of Engineer-in-charge.

196

605

118629

... More
ii) 600 mm Dia

5

69471

347359

... More
iii) 900 mm Dia

10

129786

1297862

... More
iii) 3 Core x 1.5 sq. mm. (copper)

250

102

25667.5

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

850

136

115718.99999999999

... More
v) 4 Core x 2.5 sq. mm Copper Cable FRLS

150

158

23712.000000000004

... More
vi) 3 Core x 1.5 sq. mm.

10

321

3217.6

... More
vii) 3 Core x 2.5 sq. mm

26

321

8365.76

... More
Supply & fixing of flame proof junction box (4 way entry) of BALIGA /CEAG-FCG/FLEXPRO/FEPL make including clamping arrangement, all complete as per specification and direction of Engineer In-charge.

3

1367

4101.6

... More
ii) 32 x 6 mm G.I.strip

200

138

27714

... More
iii) 50 x 6 mm G.I. Strip

60

205

12346.2

... More
v) 25 x 3 mm GI strip

50

68

3447.5

... More
Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job)

1

1502

1502.21

... More
iv) Current Capacity:50kA Primary Conductor(Inner pipe dia-40NB; Electrode Outer Pipe Dia-100NB Length of Concentric Pipes:3M

2

23540

47081.28

... More
i) Upto 32A SP MCB

2

185

370.08

... More
ii) Upto 32A DP MCB

13

517

6721.26

... More
iii) 6A to 32A DP MCB

13

517

6721.26

... More
iii) 500VA CVT

8

5738

45909.04

... More
iv) 5KVA stabilizer

5

13823

69118.95000000001

... More
Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.

15

2483

37246.5

... More
i) 450 X 300 X 250 mm

1

3066

3066.05

... More
iv) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/318. Manhole cover plates and frame to be paid separately .

4

576985

2307942.32

... More
iv) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/324. Manhole cover plates and frame to be paid separately .

1

998305

998305.49

... More
ii) S/L Threaded U/G HD MS Pipes of 80 mm dia with fittings,doping

50

1176

58836.5

... More
iii) S/L Threaded U/G HD MS Pipes of 50 mm dia with fittings,doping

75

754

56600.99999999999

... More
ii) Supply & installation of U type CS bend on vent pipe of 50 mm dia

2

783

1566.02

... More
iii) S/I Screwed type GM Ball Valve of 50 mm dia

26

3335

86731.32

... More
i) 2 product - 4 nozzle MPPs/MPDs

8

11604

92835.36

... More
iii) 15/20 KL Tank with fittings : 0 - 30 Km

4

7685

30743.2

... More
v) 50/70 KL Tanks with fittings : 0 - 30 Km

1

22170

22170.57

... More
ix) Mono/Duo pump/Air Comp/STP/All other pumps - (3 nos. up to 6 nos. pumps), 0-30 Km

1

6640

6640.53

... More
xiii) MPD/MPP pumps - (3 nos. up to 6 nos. pumps), 0-30 Km

2

7960

15920.24

... More
Removing the water carefully from U/G tank with SR pump, in such a way that there is no loss of product. The water has to be thrown away and the product to be put back into the tank etc. complete.

5

1145

5725.950000000001

... More
Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval.

3

6088

18266.79

... More
Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge

5

1547

7738.75



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.