With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction Of New Canopy, Dismantling Along With Buy Back Of Existing Canopy At Rajendra Nagar Service Station Under Patna Divisional Office Of Indian Oil Corporation Limited ,bihar State Office.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_BSO_182912_1Bid Award Id
ViewTender No
BSO/ENGG/LC-18/LT01Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Bidders_help_Document_for_Preferencial_ Bidding_20230207_v1
Special_Instructions_to_the_Bidders_20230207_version_1a
INSTRUCTIONS FOR DECLARATIONS
BOQ Items
... More
Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
7
2262
15837.57
... More
Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
50
770
38532
... More
i) Local Fine Sand within grading zone IV
1
1312
1312.05
... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
60
83
5037
... More
v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
10
169
1698.7
... More
Centering and shuttering including strutting, propping etc. and removal of form work for:
12
332
3989.76
... More
i) Foundations,footings,bases of column
500
108
54410
... More
iii) Columns, piers, abutment, pillars,posts & struts
8000
3
29600
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
-
-
-
... More
i) All kinds of Soil
50
162
8116
... More
Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
12
80
968.4
... More
Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
-
-
-
... More
i) Local Fine Sand within grading zone IV
35
1355
47430.6
... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
-
-
-
... More
v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
1.5
5586
8380.41
... More
Centering and shuttering including strutting, propping etc. and removal of form work for:
-
-
-
... More
i) Foundations,footings,bases of column
20
254
5085.2
... More
iii) Columns, piers, abutment, pillars,posts & struts
20
654
13098.2
... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
-
-
-
... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
8.5
6889
58559.9
... More
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
... More
i) Foundations,footings,bases of columns, etc. for mass concrete
20
254
5085.2
... More
v) Columns, Pillars, Piers, Abutments, Posts and Struts.
25
654
16372.75
... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
-
-
-
... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
850
74
63359
... More
Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
20
607
12154.8
... More
Preparation of fabrication drawings, bill of materials, getting approval from consultant/Client, including supply and factory fabrication of Pre-engineered steel structures such as columns, column bracings, sheeting posts, rafters, roof bracings, struts,roof purlins, side runners, sag angles, sag rods, chequered plates, stair cases, ladder, Anchor bolts (anchor bolts supply by Pre Engineered Beam vendor and fixing shall be carried out by civil contractor) etc and all other structural items as required in case of canopies at ROs. This includes surface prepartion by shot/grit/copper slag blasting to Swedish Standard SA 2½ for painting, supply and application of Painting for structural members as per specifications (Primer coat: Red Oxide Zinc Phosphate Primer (P3), DFT 60-70 µm (2 coats of 30-35 µm); Finish coat: Synthetic Enamel Paint (F6), DFT 40-50 µm (2 coats of 20-25 µm); Total DFT shall be minimum 100 µm) at site of approved colour, including loading, transportation, unloading, delivery at erection site, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and bolting/welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. (Payment shall be made based on approved fabrication drawings)
12500
114
1426750
... More
Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge.
-
-
-
... More
ii) Plain Sheet for Ridges (500 - 600mm).
40
371
14863.6
... More
iii) Plain sheet for Flashings/ Aprons (Upto 600 mm)
60
329
19740.6
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
-
-
-
... More
iii) 160 mm diameter
26
721
18761.86
... More
Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
252
1339
337548.96
... More
Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge.
252
923
232694.28
... More
Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet)
25
929
23246.5
... More
Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :
-
-
-
... More
v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate
32
518
16594.88
... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
-
-
-
... More
iii) 3 Core x 1.5 sq. mm. (copper)
200
102
20534
... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
350
136
47649
... More
CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
-
-
-
... More
vi) 3 Core x 1.5 sq. mm.
4
321
1287.04
... More
vii) 3 Core x 2.5 sq. mm
8
321
2574.08
... More
Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
-
-
-
... More
v) 25 x 3 mm GI strip
40
68
2758
... More
Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc.
-
-
-
... More
ii) Upto 32A DP MCB
6
517
3102.12
... More
Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 80 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff = 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
26
7267
188947.46