Public Works Building And NH Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 88,148Document Cost
₹ 900Tender Fee
Refer Documents
Summary
Construction Of Classroom Building At Iti Majuli Under Esdi Scheme, Majuli, Assam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PWBNH_34974_1Tender No
LBCNL/2023-24/Majuli/M-03/1131Tender Authority
Public Works Building And NH Department ViewPurchaser Address
-Website
http://https://pwdbnh.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
132.8
-
-
CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level : 4.1.2 1: 1 ½:3 (1 Cement: 1 ½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natursal sources)
10.29
-
-
Providing and laying damp-proof course 50 mm thick with concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) :4 graded stone aggregate 20 mm nominal size)
44.21
-
-
Making plinths protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size, wall remmed and consolidated and grouted with fine sand , including necessary excavation, levelling & dressing & finishing the top smooth
45.3
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size )
28.6
-
-
Excavating , supplying and filling of local earth ( including rayalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
1985.8
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources.
32.6
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, coloumns, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources.
8.9
-
-
Reinforced cement concrete work in beanms, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain wwndow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size.
10.2
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of coloumns, etc. for mass concrete
75.8
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.3 SUSpended floors, roofs, landings, blconies and access platform
32.6
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
54.7
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Colums, Pillars, Piers, Abutments, Post and Struts
65.7
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : 6.1.1 Cement mortar 1:3 (1 cement : 4 coarse sand)
33.5
-
-
Half brick mansonry with common burnt clay F.P.S (non modlar) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 ( 1 cement : 3 coarse sand)
276.13
-
-
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener cnsisting of mix 1:2 ( 1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This include cost of cement slurry, but excluding the cost of nosing o steps etc.. complete
125.6
-
-
Steel work in build up tubular (round, square or rectagular hollow tubes etc.) trusses etc. including cutting, hoistin, fixing I position and applying a primig coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes.
2518.5
-
-
Provding corrugated G.S sheet roofing incluing vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet wwshers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and inluding cutting to size and shape wherver required. 0.80 mm thick with coating not less than 275 gm/m2
154.05
-
-
Providing ridges or hips of width 60 cm overall width plain G.S Sheet fixed with polymer coteed J or L hooks, bolts and nuts 8 mm dia G.I limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m2
24.96
-
-
Cement plaster skirting uup to 30 cm height, with cement mortar 1:3 ( 1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 thick
34.45
-
-
Provinding and fixing ISI marked flush door shutters conforming to IS ; 2202 ( Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
12.6
-
-
Providing and fixing M.S Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
234.7
-
-
Providing and fixing IS : 12817 marked stainless steel butt hinges ( heavy weight) with stainless steel screws etc complete : 9.71.1 125x64x2.50 mm
18
-
-
Provding and fixing alluminium sliding door nbolts, ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 9.96.1 300x16 mm
6
-
-
Provding and fixing glazing in aluminium door, window, ventilator shutters and partitions ec. With EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in charge. (cost of aluminium snap beading shall be paid in basic item): 21.3.3 With float glass panes of 8mm thickness (weight not less than 20 kg/sqm)
43.7
-
-
Brick Soling : Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna san, with commo burnt clay non modular bricks.
154.7
-
-
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manfacturer, in all colours and shade, laid on 20 mm thcik cement mortar 1:4 ( 1 cement : 4 coarse sand ) jointing with grey cement slurry @3.3 kg/sqm including grounting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size 11.41A.1.1 Size of Tile 600 x 600 mm
157.6
-
-
15 mm cement plaster on the rough side of single or half brick wall o fmix : 13.2.1 1:4 (1 cement : 4 fine sand)
143.7
-
-
12 mm cement plaster : 13.1.1 1:4 (1 cement : 4 fine sand)
121.4
-
-
Providing and fixing pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges , jamb, bea and if required angle threshold of mild steel angle of section 50x25 mm or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed togetjher by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar gaurds, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Fixing with adjustable lugs with split end tail to each jamb
15.6
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not les than grade AC 10 as per IS : 1868) transparent or dyed to require colour or shade, with necessary screws etc. complete : 300x 10 mm
18
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not les than grade AC 10 as per IS : 1868) transparent or dyed to require colour or shade, with necessary screws etc. complete : 125 mm
12
-
-
PLASTER OF PARIS & WALL PUTTY Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, ober the plastered wall surface to prepare the surface even and smooth complete.
287.6
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : water thinnable cement primer
287.6
-
-
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives. 13.48A. 1 New work (Two or more coats applied @1.43 litre/10 sqm. Over and including priming oat of exterior primer applied @0.90 litre/10 sqm
287.8
-
-
Providing and fixing false ceiling at all height including proviidng and fixing of frame work made of special sections, power pressed from M.S. sheets and galvaniszed with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required lenghth with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45 x 15 x 0,90 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm , at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter chanel with the hlep of dry walls screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish
112.7
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. ThermoMechanically treated bars of grade Fe-500D or more.
2150.6
-
-
Float glass panes of nomina thickness 5 mm (weight not less than 112.50 kg?sqm) sqm 515.00
42.4
-
-
Silicon gasket in Kg (Above 50 g/m)
10
-
-
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. 1.1.1 Group A
12
-
-
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. 1.1.2 Group B
12
-
-
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. 1.1.3 Group C
13
-
-
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfce/ recessed steel conduit as required 1.7.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
120
-
-
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfce/ recessed steel conduit as required 1.7.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
70
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.4 2 + 12 way, Double door
3
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 volts, ka"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commisioning etc as reuired. 2.10.1 Single Pole
15
-
-
Supply and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 5/6 amps switch
22
-
-
Supply and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 3 pin 5/6 amp socket outlet
4
-
-
Supply and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 6 pin 15/16 amp socket outlet
4
-
-
Earthing with copper earth plate 600 mm x 600 mmx 3 mm thick including acccesories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
1
-
-
Supplying and laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as require. ( jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
10
-
-
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing as required
8
-
-
Providing an fixing 25 mm x 5mm G.I strip on surface or in recess for connections etc as required.
5
-
-
Ceiling light as per directed by department Phillips/jaguar/Bajaj or equivalent as approved by the department
20
-
-
CeilingFan (orient/USHA/bajaj/Havells or equivalent) as approved by department
12
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of receesed conduit as required 1.21.2. 25 mm
20
-
-
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including acccesories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
1
-
-
Supplying and laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
16.5
-
-
A. supply,installation, testing & commissioning of 9 Kg BG cartage type portable Fire Extinguisher Finish Fire make or equivalent as approved by the deptt.
3
-
-
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing as required
16.24
-
-